Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Clin Infect Dis ; 46(11): 1710-6, 2008 Jun 01.
Article in English | MEDLINE | ID: mdl-18444789

ABSTRACT

BACKGROUND: The purpose of the study was to evaluate the performance and feasibility of tuberculosis diagnosis by sputum microscopy after bleach sedimentation, compared with by conventional direct smear microscopy, in a setting of high prevalence of HIV. METHODS: In a community-based study in Kenya (a population in which 50% of individuals with tuberculosis are infected with HIV), individuals with suspected pulmonary tuberculosis submitted 3 sputum specimens during 2 consecutive days, which were examined by blind evaluation. Ziehl-Neelsen-stained smears were made of fresh specimens and of specimens that were processed with 3.5% household bleach followed by overnight sedimentation. Two different cutoffs for acid-fast bacilli (AFB) per 100 high-power fields (HPF) were used to define a positive smear: >10 AFB/100 HPF and 1 AFB/100 HPF. Four smear-positive case definitions, based on 1 or 2 positive smears with the 1 AFB or 10 AFB cutoff, were used. RESULTS: Of 1879 specimens from 644 patients, 363 (19.3%) and 460 (24.5%) were positive by bleach sedimentation microscopy, compared with 301 (16.0%) and 374 (19.9%) by direct smear microscopy, with use of the 10 AFB/100 HPF (P < .001) and 1 AFB/100 HPF (P < .001) cutoffs, respectively. Regardless of the case definition used, bleach sedimentation microscopy detected significantly more positive cases than did direct smear microscopy: 26.7% (172 of 644) versus 21.7% (140 of 644), respectively, with the case definition of 1 positive smear and the 1 AFB/100 HPF cutoff (P < .001), and 21.4% (138 of 644) versus 18.6% (120 of 644), respectively, with the case definition of 1 positive smear and the 10 AFB/100 HPF cutoff (P < .001). Inter- and intrareader reproducibility were favorable, with kappa coefficients of 0.83 and 0.91, respectively. Bleach sedimentation was relatively inexpensive and was not time consuming. CONCLUSIONS: Bleach sedimentation microscopy is an effective, simple method to improve the yield of smear microscopy in a setting of high prevalence of HIV. Further evaluation of this method, under operational conditions, is urgently needed to determine its potential as a tool for tuberculosis control.


Subject(s)
Bacteriological Techniques , HIV Infections/complications , HIV Infections/epidemiology , Specimen Handling/methods , Sputum/microbiology , Tuberculosis, Pulmonary/diagnosis , Tuberculosis, Pulmonary/microbiology , Centrifugation , Humans , Microscopy , Prevalence , Sodium Hypochlorite
2.
PLoS One ; 6(5): e20175, 2011.
Article in English | MEDLINE | ID: mdl-21655284

ABSTRACT

BACKGROUND: Sputum microscopy is the only diagnostic for tuberculosis (TB) available at peripheral levels of health service in resource-poor countries. Its sensitivity is reduced in high HIV-prevalence settings. Sodium hypochlorite (NaOCl) specimen sedimentation prior microscopy and light-emitting diode (LED)-fluorescence microscopy (FM) can individually improve performance of microscopy. This study aimed to evaluate the performance of combined LED-FM and NaOCl sputum sedimentation for TB detection at peripheral level of health services. METHODS: A prospective study was conducted in an urban health clinic in Nairobi, Kenya. Three sputum specimens were collected over 2 days from consecutive TB suspects. Smears were prepared and stained with auramine O and Ziehl-Neelsen (ZN) methods. Bleach (3.5%) was added to the remaining specimen before overnight sedimentation at room temperature. Auramine O staining was performed on smears of sediment. A 4(th) specimen was collected for TB culture. Auramine smears were read under the same microscope as used for ZN smears, but equipped with the LED FluoLED™ fluorescence illuminator. RESULTS: 497 patients were included, and 1394 specimens collected. The yield of positive specimen was significantly increased after NaOCl sedimentation (24.9%) compared to direct LED-FM (20.6%) and direct ZN (20.3%). In detecting smear-positive patients, sensitivity was 78.5% for LED-FM after NaOCl sedimentation compared to 73.2% and 72.0% for direct LED-FM (P = 0.06) and direct ZN (P = 0.06), respectively. Specificity was 87.8% for LED-FM after NaOCl sedimentation compared to 96.7% and 95.9% for direct LED-FM (P<0.01) and direct ZN (P<0.01), respectively. Inter-reading agreement (kappa = 0.7) and technicians' acceptability were good. CONCLUSION: NaOCl sedimentation did not improve the performance of LED-FM in the diagnosis of pulmonary TB at peripheral health service level.


Subject(s)
Microscopy, Fluorescence/methods , Specimen Handling/methods , Tuberculosis/diagnosis , Adult , Female , Humans , Male , Middle Aged , Prospective Studies , Sodium Hypochlorite , Young Adult
3.
PLoS One ; 6(2): e17214, 2011 Feb 18.
Article in English | MEDLINE | ID: mdl-21364757

ABSTRACT

BACKGROUND: Sputum microscopy is the only tuberculosis (TB) diagnostic available at peripheral levels of care in resource limited countries. Its sensitivity is low, particularly in high HIV prevalence settings. Fluorescence microscopy (FM) can improve performance of microscopy and with the new light emitting diode (LED) technologies could be appropriate for peripheral settings. The study aimed to compare the performance of LED-FM versus Ziehl-Neelsen (ZN) microscopy and to assess feasibility of LED-FM at a low level of care in a high HIV prevalence country. METHODS: A prospective study was conducted in an urban health clinic in Nairobi, Kenya. Three sputum specimens were collected over 2 days from suspected TB patients. Each sample was processed with Auramine O and ZN methods and a 4(th) specimen was collected for TB culture reference standard. Auramine smears were read using the same microscope, equipped with the FluoLED™ fluorescence illuminator. Inter-reader agreement, reading time and technicians' acceptability assessed feasibility. RESULTS: 497 patients were included and 1394 specimens were collected. The detection yields of LED-FM and ZN microscopy were 20.3% and 20.6% (p = 0.64), respectively. Sensitivity was 73.2% for LED-FM and 72% for ZN microscopy, p = 0.32. It was 96.7% and 95.9% for specificity, p = 0.53. Inter-reader agreement was high (kappa = 0.9). Mean reading time was three times faster than ZN microscopy with very good acceptance by technicians. CONCLUSIONS: Although it did not increase sensitivity, the faster reading time combined with very good acceptance and ease of use supports the introduction of LED-FM at the peripheral laboratory level of high TB and HIV burden countries.


Subject(s)
Tuberculosis/diagnosis , Adolescent , Adult , Algorithms , Efficiency , Feasibility Studies , Female , Hospitals, Satellite , Humans , Kenya , Lasers, Semiconductor , Light , Male , Microscopy, Fluorescence/instrumentation , Microscopy, Fluorescence/methods , Middle Aged , Models, Biological , Mycobacterium tuberculosis/isolation & purification , Sensitivity and Specificity , Sputum/chemistry , Sputum/microbiology , Tuberculosis/epidemiology , Tuberculosis/microbiology , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL