Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 66
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Curr Cardiol Rep ; 25(5): 401-409, 2023 05.
Article in English | MEDLINE | ID: mdl-37010802

ABSTRACT

PURPOSE OF REVIEW: Coronary artery disease (CAD) is estimated to account for over 60% of heart failure (HF) patients and is associated with worse outcomes than a non-ischemic etiology. In patients with ischemic HF, myocardial revascularization has multiple mechanisms of action based on the concept that blood flow restoration of viable but underperfused myocardium might reverse the hibernation of the left ventricle and prevent future spontaneous myocardial infarction, which could potentially improve patients' outcomes. Here, we aim to elaborate on indications, timing, type, and impact of completeness of revascularization in patients with heart failure with reduced ejection fraction (HFrEF) and ischemic etiology. RECENT FINDINGS: For decades, coronary artery bypass graft surgery has been the pilar of revascularization in patents with multivessel CAD and reduced EF. Recent development in the interventional field led to overall increase of percutaneous coronary intervention (PCI) adoption in treatment of ischemic HFrEF. However, recently published randomized study demonstrated no added benefit of PCI over optimal medical therapy in patients with severe ischemic cardiomyopathy challenging the beneficial role of revascularization in this setting. Since the decision on revascularization in ischemic cardiomyopathy frequently cannot be made based strictly on guidelines, tailored treatment strategy should be mandated with the essential role of multidisciplinary approach. These decisions should be based on capability to achieve complete revascularization, with the consideration that in certain situations it may not be accomplished.


Subject(s)
Cardiomyopathies , Coronary Artery Disease , Heart Failure , Myocardial Ischemia , Percutaneous Coronary Intervention , Humans , Stroke Volume/physiology , Heart Failure/complications , Heart Failure/surgery , Ventricular Function, Left , Coronary Artery Disease/complications , Coronary Artery Disease/surgery , Myocardial Ischemia/complications , Myocardial Ischemia/surgery , Cardiomyopathies/complications , Treatment Outcome
2.
Catheter Cardiovasc Interv ; 98(5): 914-922, 2021 11 01.
Article in English | MEDLINE | ID: mdl-32946190

ABSTRACT

OBJECTIVE: This study aimed to evaluate the pharmacokinetic profile and tissue effects of everolimus delivered into arterial wall using biodegradable nanospheres. BACKGROUND: Delivery of everolimus into the arterial wall is challenging due to its low-lipophilic profile. METHODS: A pharmacokinetic study included 28 porcine coronary arterial segments initially injured with balloon angioplasty followed by the local delivery of everolimus encapsulated in nanospheres (EEN) via injection through a microporous delivery catheter. The animals were sacrificed at 1 hour, 1,7,28, and 90-day follow-up. In the tissue effects study 16 coronary bare metal stent (BMS) were implanted following EEN delivery, 15 BMS following nanospheres delivery without the drug (reference group) and 16 implanted BMS served as a control. Angiographic and histology follow-up was scheduled at 28 and 90-day. RESULTS: The study showed high-everolimus concentrations in arterial tissue early after nanoparticles delivery followed by its gradual decrease to 1.15 ± 0.40 ng/mg at 90 days. Histology analysis showed favorable biocompatibility and healing profile with comparable area stenosis between groups at both time-points. CONCLUSIONS: The present study demonstrates for the first time the safety, biocompatibility, and long-term retention of everolimus in arterial tissue after single local delivery of biodegradable nanospheres.


Subject(s)
Coronary Restenosis , Drug-Eluting Stents , Nanospheres , Animals , Coronary Angiography , Everolimus , Prosthesis Design , Sirolimus , Stents , Swine , Treatment Outcome
3.
Circulation ; 137(2): 166-183, 2018 01 09.
Article in English | MEDLINE | ID: mdl-29030347

ABSTRACT

BACKGROUND: Extracellular matrix (ECM) remodeling contributes to in-stent restenosis and thrombosis. Despite its important clinical implications, little is known about ECM changes post-stent implantation. METHODS: Bare-metal and drug-eluting stents were implanted in pig coronary arteries with an overstretch under optical coherence tomography guidance. Stented segments were harvested 1, 3, 7, 14, and 28 days post-stenting for proteomics analysis of the media and neointima. RESULTS: A total of 151 ECM and ECM-associated proteins were identified by mass spectrometry. After stent implantation, proteins involved in regulating calcification were upregulated in the neointima of drug-eluting stents. The earliest changes in the media were proteins involved in inflammation and thrombosis, followed by changes in regulatory ECM proteins. By day 28, basement membrane proteins were reduced in drug-eluting stents in comparison with bare-metal stents. In contrast, the large aggregating proteoglycan aggrecan was increased. Aggrecanases of the ADAMTS (a disintegrin and metalloproteinase with thrombospondin motifs) family contribute to the catabolism of vascular proteoglycans. An increase in ADAMTS-specific aggrecan fragments was accompanied by a notable shift from ADAMTS1 and ADAMTS5 to ADAMTS4 gene expression after stent implantation. Immunostaining in human stented coronary arteries confirmed the presence of aggrecan and aggrecan fragments, in particular, at the contacts of the stent struts with the artery. Further investigation of aggrecan presence in the human vasculature revealed that aggrecan and aggrecan cleavage were more abundant in human arteries than in human veins. In addition, aggrecan synthesis was induced on grafting a vein into the arterial circulation, suggesting an important role for aggrecan in vascular plasticity. Finally, lack of ADAMTS-5 activity in mice resulted in an accumulation of aggrecan and a dilation of the thoracic aorta, confirming that aggrecanase activity regulates aggrecan abundance in the arterial wall and contributes to vascular remodeling. CONCLUSIONS: Significant differences were identified by proteomics in the ECM of coronary arteries after bare-metal and drug-eluting stent implantation, most notably an upregulation of aggrecan, a major ECM component of cartilaginous tissues that confers resistance to compression. The accumulation of aggrecan coincided with a shift in ADAMTS gene expression. This study provides the first evidence implicating aggrecan and aggrecanases in the vascular injury response after stenting.


Subject(s)
ADAMTS Proteins/metabolism , Aggrecans , Coronary Vessels/surgery , Endopeptidases/metabolism , Extracellular Matrix/enzymology , Percutaneous Coronary Intervention/instrumentation , Proteomics/methods , Stents , Vascular Remodeling , ADAMTS Proteins/genetics , ADAMTS5 Protein/genetics , ADAMTS5 Protein/metabolism , Animals , Chromatography, High Pressure Liquid , Coronary Vessels/enzymology , Coronary Vessels/physiopathology , Drug-Eluting Stents , Endopeptidases/genetics , Female , Humans , Male , Metals , Mice, Knockout , Models, Animal , Neointima , Prosthesis Design , Signal Transduction , Sus scrofa , Tandem Mass Spectrometry , Time Factors
4.
Catheter Cardiovasc Interv ; 93(7): E362-E368, 2019 06 01.
Article in English | MEDLINE | ID: mdl-30298545

ABSTRACT

OBJECTIVES: We sought to determine the 1-year clinical follow-up in patients treated with the thin strut (71 µm) bioabsorbable polymer-coated sirolimus-eluting stent (BP-SES) vs durable coating everolimus eluting stent (DP-EES) in daily clinical routine. BACKGROUND: Presence of durable polymers may be associated with late/very late stent thrombosis occurrence and the need for prolonged dual antiplatelet therapy. Bioabsorbable polymers may facilitate stent healing, thus enhancing clinical safety. METHODS: Interventional Cardiology Network Registry is a prospective, multicenter, observational registry of 21,400 consecutive patients treated with PCI since 2010. We analyzed 4,670 patients treated with either a BP-SES (ALEX, Balton, Poland) or DP-EES (XIENCE, Abbott, USA) with available 1-year clinical follow-up using propensity-score matching. Outcomes included target vessel revascularization (TVR) as efficacy outcome and all cause death, myocardial infarction (MI), and definite/probable stent thrombosis as safety outcomes. RESULTS: After propensity score matching, 1,649 patients treated with BP-SES and 1,649 patients treated with DP-EES were selected. Procedural and clinical characteristics were similar between both groups. There was no significant difference between tested groups in in-hospital mortality. One-year follow-up demonstrated comparable efficacy outcome, TVR (BP-SES 5.9% vs DP-EES 4.6% P = 0.45), as well as comparable safety outcomes, all cause death, MI and definite/probable stent thrombosis. CONCLUSIONS: In this multicenter registry, the BP-SES thin strut biodegradable polymer-coated sirolimus-eluting stent demonstrated comparable clinical outcomes at 1-year after implantation to the DP-EES. These data support the relative safety and efficacy of DP-SES in a broad range of patients undergoing percutaneous coronary intervention.


Subject(s)
Absorbable Implants , Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Polymers , Sirolimus/administration & dosage , Aged , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/mortality , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Everolimus/administration & dosage , Female , Humans , Male , Middle Aged , Poland , Propensity Score , Prosthesis Design , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Sirolimus/adverse effects , Time Factors , Treatment Outcome
5.
Catheter Cardiovasc Interv ; 92(3): E246-E253, 2018 09 01.
Article in English | MEDLINE | ID: mdl-29243353

ABSTRACT

OBJECTIVES: In this first-in-human study, we prospectively studied the vascular compatibility and mechanical performance of a novel bare ultra-high molecular weight amorphous PLLA bioresorbable scaffold (BRS, FORTITUDE®, Amaranth Medical, Mountain View, California) up to two years after implantation using multimodality imaging techniques. BACKGROUND: The vascular biocompatibility of polymers used in BRS has not been fully characterized in the absence of anti-proliferative drugs. METHODS: A total of 10 patients undergoing single scaffold implantation were included in the final analysis and were followed up using optical coherence tomography (OCT) at 2-years. All devices were implanted under angiographic and intravascular ultrasound (IVUS) guidance. Angiographic and IVUS follow up was performed at 6 months. Additionally, angiography and OCT imaging were performed at 2-years. RESULTS: At 6 months, mean intra-scaffold angiographic MLD slightly decreased from baseline procedural values. However, at 2 years, mean angiographic MLD increased (post procedure; 2.9 [2.7, 3.1] mm vs. 6 months; 2.1 [1.6, 2.5] vs. 2 years; 2.4 [2.1, 2.6], P = .001). Also, angiographic percent diameter stenosis decreased and late lumen gain increased between 6 months and 2 years follow up. Mean neointimal hyperplasia volume assessed by IVUS at 6 months was 26% [15.2, 29.3]. At 2 years OCT follow up neointimal hyperplasia volume was 24.2% [19.4, 28.9]. No presence of neoatherosclerosis was identified in any of the analyzed cases. CONCLUSION: At 2 years, this novel PLLA-based BRS induced expansive vascular remodeling from 6 to 24 months, a biological phenomenon that appears to be independent of the presence of anti-proliferative drugs.


Subject(s)
Absorbable Implants , Coronary Angiography , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Percutaneous Coronary Intervention/instrumentation , Polyesters/chemistry , Tomography, Optical Coherence , Ultrasonography, Interventional , Vascular Remodeling , Aged , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/pathology , Coronary Artery Disease/physiopathology , Coronary Vessels/pathology , Coronary Vessels/physiopathology , Feasibility Studies , Female , Humans , Hyperplasia , Male , Middle Aged , Molecular Weight , Multimodal Imaging , Neointima , Percutaneous Coronary Intervention/adverse effects , Predictive Value of Tests , Prospective Studies , Prosthesis Design , Time Factors , Treatment Outcome
6.
Catheter Cardiovasc Interv ; 91(3): 378-386, 2018 02 15.
Article in English | MEDLINE | ID: mdl-28471065

ABSTRACT

OBJECTIVES: The aim of the study was to evaluate the biomechanical properties and healing pattern of novel sirolimus-eluting, ultrahigh molecular weight amorphous poly-L-lactic acid bioresorbable scaffolds (S-BRS) that have been postdilated by 0.55 and 0.8 mm beyond the nominal diameters within the pressure-diameter compliance chart range. BACKGROUND: Due to the inherent limitations of bioabsorbable polymeric materials, overexpansion/upsizing may be very limited for some BRS such as the benchmark Absorb BVS. The unique biomechanical properties of the novel S-BRS may allow it to be safely upsized. METHODS AND RESULTS: 12 coronary arteries of 4 healthy Yucatan mini-swine underwent implantation of a novel S-BRS. Upsizing by postdilation was performed up to 0.55mm (PLUS 0.55, n = 6) or 0.8 mm (PLUS 0.8, n = 6) in a manner maintaining consistent 1:1.1 stent-to-artery, thus ensuring not only the overexpansion of the scaffold but consistent level of arterial injury. Optical coherence tomography (OCT) follow-up was performed at 28 and 90-days follow-up. There was no statistical difference between the tested groups in terms of acute recoil. OCT analysis after 28 days showed numerically lower levels of neointimal formation in PLUS 0.8 compared to PLUS 0.55 group. These results were sustained at 90-days follow-up. There was no difference in late recoil between studied groups. No scaffold discontinuation, deformation or overlapping of the struts were observed. CONCLUSIONS: Overexpansion up to 0.8 mm of novel, high strength S-BRS is not associated with worse angiographic outcomes, neointimal formation or biomechanical issues such as scaffold discontinuation, deformation or overlapping of the struts, neither acutely nor chronically. © 2017 Wiley Periodicals, Inc.


Subject(s)
Absorbable Implants , Angioplasty, Balloon, Coronary/instrumentation , Coronary Vessels/surgery , Polyesters/chemistry , Tomography, Optical Coherence , Angioplasty, Balloon, Coronary/adverse effects , Animals , Coronary Angiography , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Materials Testing , Models, Animal , Molecular Weight , Predictive Value of Tests , Prosthesis Design , Swine , Swine, Miniature , Time Factors , Ultrasonography, Interventional
7.
Circ J ; 80(8): 1804-11, 2016 Jul 25.
Article in English | MEDLINE | ID: mdl-27334029

ABSTRACT

BACKGROUND: The OCTOPUS registry prospectively evaluates the procedural and long-term outcomes of saphenous vein graft (SVG) PCI. The current study assessed the morphology of de novo lesions and in-stent restenosis (ISR) in patients undergoing PCI of SVG. METHODS AND RESULTS: Optical coherence tomography (OCT) of SVG lesions in consecutive patients presenting with stable CAD and ACS was carried out. Thirty-nine patients (32 de novo and 10 ISR lesions) were included in the registry. ISR occurred in 5 BMS and 5 DES. There were no differences in the presence of plaque rupture and thrombus between de novo lesions and ISR. Lipid-rich tissue was identified in both de novo lesions and in ISR (75% vs. 50%, P=0.071) with a higher prevalence in BMS than in DES (23% vs. 7.5%; P=0.048). Calcific de novo lesions were detected in older grafts as compared with non-calcific atheromas (159±57 vs. 90±62 months after CABG, P=0.001). Heterogeneous neointima was found only in ISR (70% vs. 0, P<0.001) and was observed with similar frequency in both BMS and DES (24% vs. 30%, P=0.657). ISR was detected earlier in DES than BMS (median, 50 months; IQR, 18-96 months vs. 27 months; IQR, 13-29 months, P<0.001). CONCLUSIONS: OCT-based characteristics of de novo and ISR lesions in SVG were similar except for heterogeneous tissue, which was observed only in ISR. (Circ J 2016; 80: 1804-1811).


Subject(s)
Graft Occlusion, Vascular , Percutaneous Coronary Intervention , Saphenous Vein/diagnostic imaging , Stents , Tomography, Optical Coherence , Aged , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Female , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/surgery , Humans , Male , Middle Aged , Plaque, Atherosclerotic/diagnostic imaging , Plaque, Atherosclerotic/surgery , Prospective Studies , Transplants
8.
J Interv Cardiol ; 28(4): 348-57, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26224390

ABSTRACT

BACKGROUND: There is limited comparative clinical data regarding the safety and efficacy profile of paclitaxel delivery via balloon versus stent-polymer matrix. In this study, we aimed to compare the clinical and angiographic results of two different methods of paclitaxel delivery among patients undergoing percutaneous coronary intervention (PCI) for single de novo coronary lesions. METHODS: A total of 202 patients undergoing PCI due to symptomatic heart disease and at least one significant coronary artery lesion were prospectively enrolled in a multicenter non-inferiority trial. Eligible patients were randomized to a revascularization with either a paclitaxel eluting stent (PES = Coroflex Please, B.Braun) or a bare metal stent (BMS) followed by a paclitaxel coated balloon (PCB) dilation (BMS = Coroflex + PCB = Sequent Please, B.Braun). Clinical follow-up was obtained at 9 months in all patients, whereas angiographic in a subset of 94 (46.5%) patients. RESULTS: The baseline characteristics were well balanced between groups. At 9 months, the primary endpoint of in-stent late lumen loss in BMS + PCB was comparable and non-inferior to PES (0.21 ± 0.5 vs. 0.30 ± 0.7 mm, respectively. P(non-inf) < 0.05). At 9 months, the incidence of MACE (7.0 vs. 6.9%, HR = 1, 95%CI: 0.3-2.8; P = 0.99), comprising the occurrence of myocardial infarction (4.9 vs. 3.0%, HR = 1.62, 95%CI: 0.4-6.5; P = 0.32), target lesion revascularization (6.9 vs. 5.0%, HR = 1.42, 95%CI: 0.4-4.4; p = 0.54) and stent thrombosis (4.9 vs. 3.0%, HR = 2.01, 95%CI: 0.5-7.4; P = 0.74) was comparable between BMS + PCB and PES, respectively. In the BMS + PCB group, thrombosis tended to occur within 30 days (3.9 vs. 1.0%; P = 0.38). CONCLUSIONS: Paclitaxel delivery via drug coated balloon or polymer-stent matrix achieved comparable angiographic and clinical results among patients with de novo coronary lesions. BMS + PCB revascularization was associated with a higher rate of stent thrombosis when compared to newer generation drug eluting stents, therefore, should be recommended as a bail-out for PCB alone angioplasty.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Coronary Stenosis/therapy , Paclitaxel/administration & dosage , Stents , Coronary Angiography , Coronary Artery Disease/therapy , Coronary Thrombosis/epidemiology , Female , Humans , Male , Middle Aged , Myocardial Infarction/epidemiology , Prospective Studies
9.
BMC Bioinformatics ; 15: 54, 2014 Feb 24.
Article in English | MEDLINE | ID: mdl-24564523

ABSTRACT

BACKGROUND: Amyloids are proteins capable of forming fibrils whose intramolecular contact sites assume densely packed zipper pattern. Their oligomers can underlie serious diseases, e.g. Alzheimer's and Parkinson's diseases. Recent studies show that short segments of aminoacids can be responsible for amyloidogenic properties of a protein. A few hundreds of such peptides have been experimentally found but experimental testing of all candidates is currently not feasible. Here we propose an original machine learning method for classification of aminoacid sequences, based on discovering a segment with a discriminative pattern of site-specific co-occurrences between sequence elements. The pattern is based on the positions of residues with correlated occurrence over a sliding window of a specified length. The algorithm first recognizes the most relevant training segment in each positive training instance. Then the classification is based on maximal distances between co-occurrence matrix of the relevant segments in positive training sequences and the matrix from negative training segments. The method was applied for studying sequences of aminoacids with regard to their amyloidogenic properties. RESULTS: Our method was first trained on available datasets of hexapeptides with the amyloidogenic classification, using 5 or 6-residue sliding windows. Depending on the choice of training and testing datasets, the area under ROC curve obtained the value up to 0.80 for experimental, and 0.95 for computationally generated (with 3D profile method) datasets. Importantly, the results on 5-residue segments were not significantly worse, although the classification required that algorithm first recognized the most relevant training segments. The dataset of long sequences, such as sup35 prion and a few other amyloid proteins, were applied to test the method and gave encouraging results. Our web tool FISH Amyloid was trained on all available experimental data 4-10 residues long, offers prediction of amyloidogenic segments in protein sequences. CONCLUSIONS: We proposed a new original classification method which recognizes co-occurrence patterns in sequences. The method reveals characteristic classification pattern of the data and finds the segments where its scoring is the strongest, also in long training sequences. Applied to the problem of amyloidogenic segments recognition, it showed a good potential for classification problems in bioinformatics.


Subject(s)
Amino Acids/chemistry , Amyloid/chemistry , Computational Biology/methods , Peptides/chemistry , Sequence Analysis, Protein/methods , Algorithms , Amino Acid Sequence , Artificial Intelligence , ROC Curve
10.
Catheter Cardiovasc Interv ; 83(2): 325-33, 2014 Feb.
Article in English | MEDLINE | ID: mdl-23703720

ABSTRACT

BACKGROUND: New paclitaxel coated balloons (PCB) developments have been proposed to maintain therapeutic levels of drug in the tissue while decreasing particle release. In this series of studies, we evaluated the pharmacokinetic profile and biological effects after paclitaxel delivery via novel microcrystalline PCB coating (mcPCB, Pax®, Balton) in porcine iliofemoral arteries. METHODS: Ten domestic swine were enrolled yielding 24 iliofemoral segments for evaluation. In the pharmacokinetic study, nine mcPCBs were dilated for 60 sec and animals sacrificed after 1 hr, 3 and 7 days. Studied segments were harvested and tissue paclitaxel concentration was analyzed utilizing HPLC. In the biological response evaluation, self-expandable stents were implanted followed by post dilation with either mcPCB (n = 10) or POBA (n = 5). After 28 days, angiography was performed, animals were sacrificed and stented segments harvested for histopathological evaluation. RESULTS: The 1-hr, 3 and 7 days vessel paclitaxel concentrations were 152.9 ± 154.5, 36.5 ± 49.5, and 0.9 ± 0.7 ng/mg respectively. In the biological response study, stents in the mcPCB group presented lower angiographic measures of neointimal hyperplasia as expressed by late loss when compared to POBA (-0.43 ± 0.9 vs. 0.23 ± 1.2; P = 0.24) at 28 days. In the histopathological evaluation, percent area of stenosis (%AS) was reduced by 42% in the mcPCB group (P < 0.05). The healing process in mcPCB group was comparable to POBA with regard to fibrin deposition (0.7 vs. 0.7; P = ns), neointimal maturity (1.97 vs. 1.93; P = ns), inflammation score (0.92 vs. 1; P = ns) and endothelialization score (1.77 vs. 1.73; P = ns). The mcPCB group did however display a greater tendency of medial cell loss and mineralization (60% vs. 0; P = 0.08). CONCLUSIONS: Delivery of paclitaxel via a novel mcPCB resulted in low long-term tissue retention of paclitaxel. However, this technological approach displayed reduced neointimal proliferation and favorable healing profile.


Subject(s)
Angioplasty, Balloon/instrumentation , Cardiovascular Agents/administration & dosage , Cardiovascular Agents/pharmacokinetics , Coated Materials, Biocompatible , Drug-Eluting Stents , Femoral Artery/drug effects , Iliac Artery/drug effects , Paclitaxel/administration & dosage , Paclitaxel/pharmacokinetics , Animals , Cardiovascular Agents/chemistry , Cell Proliferation/drug effects , Chromatography, High Pressure Liquid , Crystallization , Female , Femoral Artery/diagnostic imaging , Femoral Artery/metabolism , Femoral Artery/pathology , Hyperplasia , Iliac Artery/diagnostic imaging , Iliac Artery/metabolism , Iliac Artery/pathology , Male , Materials Testing , Models, Animal , Neointima , Paclitaxel/chemistry , Prosthesis Design , Radiography , Sus scrofa , Wound Healing/drug effects
11.
J Clin Med ; 13(6)2024 Mar 17.
Article in English | MEDLINE | ID: mdl-38541955

ABSTRACT

Dual antiplatelet therapy (DAPT) is mandatory after percutaneous coronary intervention (PCI) with drug-eluting stent (DES) implantation, but optimal DAPT duration remains a topic of intense discussion. The shorter regimen of DAPT might be especially beneficial for high-bleeding-risk (HBR) patients. Novel stent platforms have been designed with innovations that should facilitate vessel healing following stent implantation and enable short DAPT. This review aimed to summarize evidence of the neointimal coverage of short-term stents and their implications for DAPT duration. Results from histological and optical coherence tomography (OCT) studies confirm the significant role of uncovered struts after the implantation of a stent in patients presenting with late stent thrombosis. Several studies have shown favorable vessel healing at one month (with 83.2% of covered struts, on average) and three months following stent implantation (with 93.3% of covered struts, on average). Solely HBR patient trials have proven that one month of DAPT can be applicable and safe in this population. Three-month DAPT was tested in a more diverse population and remains effective and safe in comparison to a longer DAPT regimen. That evidence proves that short-term DAPT might be applicable, especially for HBR patients.

12.
J Clin Med ; 13(11)2024 May 25.
Article in English | MEDLINE | ID: mdl-38892807

ABSTRACT

Atherosclerosis is the predominant underlying etiopathology of coronary artery disease. Changes in plaque phenotype from stable to high risk may spur future major adverse cardiac events (MACE). Different pharmacological therapies have been implemented to mitigate this risk. Over the last two decades, intravascular imaging modalities have emerged in clinical studies to clarify how these therapies may affect the composition and burden of coronary plaques. Lipid-lowering agents, such as statins, ezetimibe, and proprotein convertase subtilisin/kexin type 9 inhibitors, were shown not only to reduce low-density lipoprotein levels and MACE but also to directly affect features of coronary plaque vulnerability. Studies have demonstrated that lipid-lowering therapy reduces the percentage of atheroma volume and number of macrophages and increases fibrous cap thickness. Future studies should answer the question of whether pharmacological plaque stabilization may be sufficient to mitigate the risk of MACE for selected groups of patients with atherosclerotic coronary disease.

13.
Biomimetics (Basel) ; 8(1)2023 Feb 09.
Article in English | MEDLINE | ID: mdl-36810403

ABSTRACT

Drug-eluting stents (DES) demonstrated superior efficacy when compared to bare metal stents and plain-old balloon angioplasty and are nowadays used in almost all percutaneous revascularization procedures. The design of the stent platforms is constantly improving to maximize its efficacy and safety. Constant development of DES includes adoption of new materials used for scaffold production, new design types, improved overexpansion abilities, new polymers coating and, finally, improved antiproliferative agents. Especially nowadays, with the immense number of available DES platforms, it is crucial to understand how different aspects of stents impact the effect of their implantation, as subtle differences between various stent platforms could impact the most important issue-clinical outcomes. This review discusses the current status of coronary stents and the impact of stent material, strut design and coating techniques on cardiovascular outcomes.

14.
J Cardiovasc Dev Dis ; 10(9)2023 Sep 18.
Article in English | MEDLINE | ID: mdl-37754828

ABSTRACT

Robots are defined as programmable machines that can perform specified tasks. Medical robots are emerging solutions in the field of cardiology leveraging recent technological innovations of control systems, sensors, actuators, and imaging modalities. Robotic platforms are successfully applied for percutaneous coronary intervention, invasive cardiac electrophysiology procedures as well as surgical operations including minimally invasive aortic and mitral valve repair, coronary artery bypass procedures, and structural heart diseases. Furthermore, machines are used as staff-assisting tools to support nurses with repetitive clinical duties i.e., food delivery. High precision and resolution allow for excellent maneuverability, enabling the performance of medical procedures in challenging anatomies that are difficult or impossible using conventional approaches. Moreover, robot-assisted techniques protect operators from occupational hazards, reducing exposure to ionizing radiation, and limiting risk of orthopedic injuries. Novel automatic systems provide advantages for patients, ensuring device stability with optimized utilization of fluoroscopy. The acceptance of robotic technology among healthcare providers as well as patients paves the way for widespread clinical application in the field of cardiovascular medicine. However, incorporation of robotic systems is associated with some disadvantages including high costs of installation and expensive disposable instrumentations, the need for large operating room space, and the necessity of dedicated training for operators due to the challenging learning curve of robotic-assisted interventional systems.

15.
Pol Arch Intern Med ; 133(9)2023 09 29.
Article in English | MEDLINE | ID: mdl-36877007

ABSTRACT

INTRODUCTION: Smoking is a well­established risk factor for cardiovascular diseases. However, in patients with ST­segment elevation myocardial infarction (STEMI), smoking has been associated with better clinical outcomes; this phenomenon became known as the "smoker's paradox." OBJECTIVES: The aim of this study was to evaluate the association between smoking and clinical outcomes in STEMI patients treated with primary percutaneous coronary intervention (PCI), using 3 large national registries. PATIENTS AND METHODS: We retrospectively analyzed the data of 82 235 hospitalized STEMI patients treated with primary PCI. Among the analyzed population, 30 966 patients (37.96%) were smokers, and 51 269 (62.36%) were nonsmokers. We evaluated the baseline characteristics, pharmacotherapy, clinical outcomes, and readmission causes in a 36­month follow­up. RESULTS: The smokers were significantly younger (median [interquartile range] age, 58 [52-64] vs 68 [59-77] years; P <0.001) than the nonsmokers, and there were more men in this group. The patients who smoked were less likely to have traditional risk factors, as compared with the nonsmokers. In the unadjusted analysis, in­hospital and 36­month mortality and rehospitalization rates were lower in the smokers group. However, after adjustment for baseline characteristics that differed between the 2 groups, the multivariable analysis showed that tobacco use was one of the independent risk factors for 36­month mortality (hazard ratio, 1.11; 95% CI, 1.06-1.18; P <0.001). CONCLUSIONS: In the present large­scale, registry­based analysis, the observed lower 36­month crude rates of adverse events among the smokers, as compared with the nonsmokers, might be partially explained by a significantly lower burden of traditional risk factors and younger age of the smokers. After accounting for age and other baseline differences, smoking was found to be one of the independent risk factors for 36­month mortality.


Subject(s)
Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Male , Humans , Middle Aged , ST Elevation Myocardial Infarction/surgery , Retrospective Studies , Smoking/adverse effects , Smoking/epidemiology , Risk Factors , Treatment Outcome
16.
Eur Heart J Cardiovasc Imaging ; 24(5): 687-693, 2023 04 24.
Article in English | MEDLINE | ID: mdl-36342269

ABSTRACT

AIMS: To study if any qualitative or quantitative optical coherence tomography (OCT) variables in combination with thin cap fibroatheroma (TCFA) patients could improve the identification of lesions at risk for future major adverse cardiac events (MACEs). METHODS AND RESULTS: From the combined optical coherence tomography morphologic and fractional flow reserve hemodynamic assessment of non- culprit lesions to better predict adverse event outcomes in diabetes mellitus patients: COMBINE (OCT-FFR) trial database (NCT02989740), we performed a detailed assessment OCT qualitative and quantitative variables in TCFA carrying diabetes mellitus (DM) patients with vs. without MACE during follow-up. MACEs were defined as a composite of cardiac death, target vessel myocardial infarction, clinically driven target lesion revascularization, and hospitalization for unstable angina. From the 390 fractional flow reserve (FFR)-negative DM patients, 98 (25.2%) had ≥1 OCT-detected TCFA, of which 13 (13.3%) had MACE and 85 (86.7%) were event-free (non-MACE). The baseline characteristics were similar between both groups; however, a smaller minimal lumen area (MLA) and lower mean FFR value were observed in MACE group (1.80 vs. 2.50 mm2, P = 0.01, and 0.85 vs. 0.89, P = 0.02, respectively). Prevalence of healed plaque (HP) was higher in the MACE group (53.85 vs. 21.18%, P = 0.01). TCFA were predominantly located proximal to the MLA. TCFA area was smaller in the MACE group, while no difference was observed regarding the lesion area. CONCLUSION: Within TCFA carrying patients, a smaller MLA, lower FFR values, and TCFA location adjacent to a HP were associated with future MACE. Carpet-like measured lesion area surface was similar, while the TCFA area was smaller in the MACE arm, and predominantly located proximal to the MLA.


Subject(s)
Coronary Artery Disease , Fractional Flow Reserve, Myocardial , Myocardial Infarction , Plaque, Atherosclerotic , Humans , Plaque, Atherosclerotic/pathology , Tomography, Optical Coherence/methods , Angina, Unstable , Coronary Vessels/pathology , Coronary Artery Disease/pathology , Predictive Value of Tests , Coronary Angiography
17.
EuroIntervention ; 18(13): e1099-e1107, 2023 Feb 06.
Article in English | MEDLINE | ID: mdl-36170036

ABSTRACT

BACKGROUND: The long-term prognostic implications of fractional flow reserve (FFR)-negative lesions hosting vulnerable plaques remain unsettled. AIMS: The aim of this study was to evaluate the association of non-ischaemic lesions hosting optical coherence tomography (OCT)-detected thin-cap fibroatheromas (TCFA) with first and recurrent cardiovascular events during follow-up up to 5 years in a diabetes mellitus (DM) patient population. METHODS: COMBINE OCT-FFR is a prospective, international, double-blind, natural history study. Patients with DM and with ≥1 FFR-negative lesion were classified into 2 groups based on the presence or absence of ≥1 TCFA lesion. The primary endpoint (PE) is a composite of cardiac mortality, target vessel-related myocardial infarction (TV-MI), clinically driven target lesion revascularisation (TLR), or unstable angina (UA) requiring hospitalisation during follow-up up to 5 years. RESULTS: Among 390 DM patients (age 67.5±9 years; 37% female) with ≥1 FFR-negative lesion, 292 (74.9%) were TCFA-negative while 98 (25.1%) were TCFA-positive. The PE occurred more frequently in TCFA-positive than in TCFA-negative patients (21.4% vs 8.2%, hazard ratio [HR] 2.89, 95% confidence interval [CI]: 1.61-5.20; p<0.001; 6.42 vs 2.46 events per 100 patient-years, rate ratio [RR] 2.61, 95% CI: 1.38-4.90; p=0.002). Furthermore, when TV-MI, TLR, and UA were treated as recurrent components of the PE, TCFA-positive patients experienced a higher risk of recurrent events (HR 2.89, 95% CI; 1.74-4.80; p<0.001; 13.45 vs 2.87 events per 100 patient-years, RR 4.69, 95% CI: 2.86-7.83; p<0.001). A multivariable analysis identified the presence of TCFA as an independent predictor of the PE (HR 2.76, 95% CI: 1.53-4.97; p<0.001). CONCLUSIONS: OCT-detected TCFA-positive lesions, although not ischaemia-generating, are associated with an increased risk of adverse events during long-term follow-up. CLINICALTRIALS: gov: NCT02989740.


Subject(s)
Coronary Artery Disease , Diabetes Mellitus , Fractional Flow Reserve, Myocardial , Myocardial Infarction , Plaque, Atherosclerotic , Humans , Female , Middle Aged , Aged , Male , Plaque, Atherosclerotic/diagnostic imaging , Plaque, Atherosclerotic/pathology , Prospective Studies , Myocardial Infarction/therapy , Prognosis , Angina, Unstable , Tomography, Optical Coherence/methods , Coronary Artery Disease/therapy , Predictive Value of Tests , Coronary Angiography/methods
18.
Article in English | MEDLINE | ID: mdl-35055800

ABSTRACT

In creating a positive climate in sport for children and youth, the role of adults is of key importance as their behavior and attitudes determine the experiences and multilateral development of young players. Relatively recently, the importance of the referee in creating a supportive sporting environment has begun to be emphasized. This concerns, in particular, team sports in which the referees interact with players many times and influence the course of the game. The aim of the study was to evaluate the quality of the referee-players' interactions during youth floorball matches in terms of building a positive climate and responsiveness to the players' needs. Another aim of the study was to examine whether the referee's qualifications and players' gender affect the quality of their interactions with the players. The study was conducted among 21 referees officiating matches for girls and boys aged 12-18. Naturalistic and structured observation methods were used in the study. The observation was conducted using a wireless intercom that allows listening to verbal messages directed to the players. Furthermore, the referee's work was recorded using a camera. The results of the statistical tests did not show any significant differences in the assessment of referees between the groups distinguished in terms of the referees' license and players' gender in both examined dimensions. The observations showed that the average rating of building a positive climate by referees during a sporting event measured on a seven-point scale was 'poor' (2.81 pts). The referees were assessed significantly higher on the second dimension (responsiveness to the players' needs), although an overall rating of 3.81 pts means a medium level of interaction quality. The results indicate areas in which referees can improve. They lead to the following conclusions: (i) the contents of training for floorball referees should include problems of pedagogy and developmental psychology; (ii) referees should be equipped with appropriate competencies for building a positive climate during matches and monitoring the players' needs; (iii) referees appointed to officiate children and youth games should be characterized by appropriate predispositions.


Subject(s)
Soccer , Sports , Youth Sports , Adolescent , Adult , Child , Female , Humans , Male
19.
Materials (Basel) ; 15(18)2022 Sep 19.
Article in English | MEDLINE | ID: mdl-36143810

ABSTRACT

Material as well as process variations in the composites industry are reasons to develop methods for in-line monitoring, which would increase reproducibility of the manufacturing process and the final composite products. Fiber Bragg Gratings (FBGs) have shown to be useful for monitoring liquid-composite molding processes, e.g., in terms of online gel point detection. Existing works however, focus on in-plane strain measurements while out-of-plane residual strain prevails. In order to measure out-of-plane strain, FBG inscribed in highly birefringent fiber (HB FBG) can be used. The purpose of this research is the cure stage detection with (a) FBG inscribed in single mode and (b) FBG inscribed in highly-birefringent side-hole fiber in comparison to the reference gel point detected with an in-mold DC sensor. Results reveal that the curing process is better traceable with HB FBG than with regular FBG. Thus, the use of HB FBG can be a good method for the gel point estimation in the RTM process.

20.
J Clin Med ; 11(24)2022 Dec 17.
Article in English | MEDLINE | ID: mdl-36556108

ABSTRACT

BACKGROUND: Scientific statements recommend multimodality imaging in myocardial infarction with non-obstructive coronary arteries (MINOCA) to define the underlying cause. AIM: We evaluated the diagnostic yield of intravascular optical coherence tomography (OCT) and cardiac magnetic resonance (CMR) in the MINOCA setting. METHODS: In this prospective, single center, observational pilot study, we enrolled patients with MINOCA without previous coronary interventions. All patients underwent three vessel OCT, followed by CMR. Imaging results were combined to determine the mechanism of MINOCA, when possible. RESULTS: We enrolled 10 patients in this pilot study. Women constituted 50% of the analyzed population. The mean age of patients was 52 years. ST-segment elevation was found in 30% of patients. A possible culprit lesion was identified by OCT in 70% of participants, most commonly plaque rupture or erosion. An ischemic pattern of CMR abnormalities was identified in 70% of participants. Myocarditis and Tako-Tsubo were identified in 30%. A cause of MINOCA was identified in all patients using multimodality imaging, while using OCT alone identification occurred in only 70% of patients. CONCLUSION: In this pilot study, multimodality imaging with OCT and CMR identified potential mechanisms in all patients with a diagnosis of MINOCA, and it has the potential to guide medical therapy for secondary prevention.

SELECTION OF CITATIONS
SEARCH DETAIL