1.
Med Phys ; 46(11): 5216-5226, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31442300

ABSTRACT

PURPOSE: Accurate, patient-specific radiation dosimetry for CT scanning is critical to optimize radiation doses and balance dose against image quality. While Monte Carlo (MC) simulation is often used to estimate doses from CT, comparison of estimates to experimentally measured values is lacking for advanced CT scanners incorporating novel design features. We aimed to compare radiation dose estimates from MC simulation to doses measured in physical anthropomorphic phantoms using metal-oxide semiconductor field-effect transistors (MOSFETs) in a 256-slice CT scanner. METHODS: Fifty MOSFETs were placed in organs within tissue-equivalent anthropomorphic adult and pediatric radiographic phantoms, which were scanned using a variety of chest, cardiac, abdomen, brain, and whole-body protocols on a 256-slice system. MC computations were performed on voxelized CT reconstructions of the phantoms using a highly parallel MC tool developed specifically for diagnostic X-ray energies and rapid computation. Doses were compared between MC estimates and physical measurements. RESULTS: The average ratio of MOSFET to MC dose in the in-field region was close to 1 (range, 0.96-1.12; mean ± SD, 1.01 ± 0.04), indicating outstanding agreement between measured and simulated doses. The difference between measured and simulated doses tended to increase with distance from the in-field region. The error in the MC simulations due to the limited number of simulated photons was less than 1%. The errors in the MOSFET dose determinations in the in-field region for a single scan were mainly due to the calibration method and were typically about 6% (8% if the error in the reading of the ionization chamber that was used for the MOSFET calibration was included). CONCLUSIONS: Radiation dose estimation using a highly parallelized MC method is strongly correlated with experimental measurements in physical adult and infant anthropomorphic phantoms for a wide range of scans performed on a 256-slice CT scanner. Incorporation into CT scanners of radiation-dose distribution estimation, employing the scanner's reconstructed images of the patient, may offer the potential for accurate patient-specific CT dosimetry.


Subject(s)
Metals/chemistry , Monte Carlo Method , Oxides , Phantoms, Imaging , Radiation Dosage , Tomography, X-Ray Computed/instrumentation , Transistors, Electronic , Adult , Calibration , Humans , Radiometry , Whole Body Imaging
2.
Med Phys ; 44(12): 6589-6602, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28940306

ABSTRACT

PURPOSE: Metal-oxide-semiconductor field-effect transistors (MOSFETs) serve as a helpful tool for organ radiation dosimetry and their use has grown in computed tomography (CT). While different approaches have been used for MOSFET calibration, those using the commonly available 100 mm pencil ionization chamber have not incorporated measurements performed throughout its length, and moreover, no previous work has rigorously evaluated the multiple sources of error involved in MOSFET calibration. In this paper, we propose a new MOSFET calibration approach to translate MOSFET voltage measurements into absorbed dose from CT, based on serial measurements performed throughout the length of a 100-mm ionization chamber, and perform an analysis of the errors of MOSFET voltage measurements and four sources of error in calibration. METHODS: MOSFET calibration was performed at two sites, to determine single calibration factors for tube potentials of 80, 100, and 120 kVp, using a 100-mm-long pencil ion chamber and a cylindrical computed tomography dose index (CTDI) phantom of 32 cm diameter. The dose profile along the 100-mm ion chamber axis was sampled in 5 mm intervals by nine MOSFETs in the nine holes of the CTDI phantom. Variance of the absorbed dose was modeled as a sum of the MOSFET voltage measurement variance and the calibration factor variance, the latter being comprised of three main subcomponents: ionization chamber reading variance, MOSFET-to-MOSFET variation and a contribution related to the fact that the average calibration factor of a few MOSFETs was used as an estimate for the average value of all MOSFETs. MOSFET voltage measurement error was estimated based on sets of repeated measurements. The calibration factor overall voltage measurement error was calculated from the above analysis. RESULTS: Calibration factors determined were close to those reported in the literature and by the manufacturer (~3 mV/mGy), ranging from 2.87 to 3.13 mV/mGy. The error σV of a MOSFET voltage measurement was shown to be proportional to the square root of the voltage V: σV=cV where c = 0.11 mV. A main contributor to the error in the calibration factor was the ionization chamber reading error with 5% error. The usage of a single calibration factor for all MOSFETs introduced an additional error of about 5-7%, depending on the number of MOSFETs that were used to determine the single calibration factor. The expected overall error in a high-dose region (~30 mGy) was estimated to be about 8%, compared to 6% when an individual MOSFET calibration was performed. For a low-dose region (~3 mGy), these values were 13% and 12%. CONCLUSIONS: A MOSFET calibration method was developed using a 100-mm pencil ion chamber and a CTDI phantom, accompanied by an absorbed dose error analysis reflecting multiple sources of measurement error. When using a single calibration factor, per tube potential, for different MOSFETs, only a small error was introduced into absorbed dose determinations, thus supporting the use of a single calibration factor for experiments involving many MOSFETs, such as those required to accurately estimate radiation effective dose.


Subject(s)
Metals/chemistry , Oxides/chemistry , Radiometry/instrumentation , Tomography, X-Ray Computed/instrumentation , Transistors, Electronic , Calibration , Research Design