Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
RNA ; 21(3): 347-59, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25605962

ABSTRACT

Splicing factor proline- and glutamine-rich (SFPQ) also commonly known as polypyrimidine tract-binding protein-associated-splicing factor (PSF) and its binding partner non-POU domain-containing octamer-binding protein (NONO/p54nrb), are highly abundant, multifunctional nuclear proteins. However, the exact role of this complex is yet to be determined. Following purification of the endogeneous SFPQ/NONO complex, mass spectrometry analysis identified a wide range of interacting proteins, including those involved in RNA processing, RNA splicing, and transcriptional regulation, consistent with a multifunctional role for SFPQ/NONO. In addition, we have identified several sites of arginine methylation in SFPQ/PSF using mass spectrometry and found that several arginines in the N-terminal domain of SFPQ/PSF are asymmetrically dimethylated. Furthermore, we find that the protein arginine N-methyltransferase, PRMT1, catalyzes this methylation in vitro and that this is antagonized by citrullination of SFPQ. Arginine methylation and citrullination of SFPQ/PSF does not affect complex formation with NONO. However, arginine methylation was shown to increase the association with mRNA in mRNP complexes in mammalian cells. Finally we show that the biochemical properties of the endogenous complex from cell lysates are significantly influenced by the ionic strength during purification. At low ionic strength, the SFPQ/NONO complex forms large heterogeneous protein assemblies or aggregates, preventing the purification of the SFPQ/NONO complex. The ability of the SFPQ/NONO complex to form varying protein assemblies, in conjunction with the effect of post-translational modifications of SFPQ modulating mRNA binding, suggests key roles affecting mRNP dynamics within the cell.


Subject(s)
Nuclear Matrix-Associated Proteins/genetics , Octamer Transcription Factors/genetics , RNA Splicing/genetics , RNA, Messenger/genetics , RNA-Binding Proteins/genetics , Transcription, Genetic , Animals , Arginine/genetics , Arginine/metabolism , DNA-Binding Proteins , Gene Expression Regulation , HeLa Cells , Humans , Methylation , Multiprotein Complexes/chemistry , Multiprotein Complexes/genetics , Nuclear Matrix-Associated Proteins/chemistry , Octamer Transcription Factors/chemistry , PTB-Associated Splicing Factor , Protein Processing, Post-Translational , Protein-Arginine N-Methyltransferases/genetics , RNA-Binding Proteins/chemistry , Repressor Proteins/genetics , Ribonucleoproteins/genetics
2.
Anal Biochem ; 393(1): 8-22, 2009 Oct 01.
Article in English | MEDLINE | ID: mdl-19524544

ABSTRACT

Amadori peptides were enriched using boronate affinity tips and measured by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS). As demonstrated by electrochemical measurements, the tips show the highest binding efficiency for glucose at pH 8.2 employing ammonium chloride/ammonia buffer with ionic strength of 150 mM, exceeding taurine buffer at the same concentration. The bound constituents were released by sorbitol and formic acid. It was also demonstrated that elution with sorbitol at 1.2 M is superior to acidic media. Comparison of results was based on the numbers of detected peptides and their glycated sites. Using sorbitol for elution requires desalting prior to analysis. Therefore, three different sorbents were tested: fullerene-derivatized silica, ZipTip (C18), and C18 silica. Fullerene-derivatized silica and ZipTip showed the same performance regarding the numbers of glycated peptides, and sites were better than C18 silica. The elaborated off-line method was compared with liquid chromatography-tandem mass spectrometry (LC-MS/MS) measurements, by which considerable less modified peptides were detected. Affinity tips used under optimized conditions were tested for the analysis of human serum albumin (HSA) from sera of healthy and diabetic individuals. A peptide with a mass of 1783.9 Da could be detected only in samples of diabetic patients and, therefore, could be a very interesting biomarker candidate.


Subject(s)
Chromatography, Affinity/methods , Glycopeptides/chemistry , Glycopeptides/isolation & purification , Glycoproteins/chemistry , Peptides/isolation & purification , Boronic Acids/chemistry , Chromatography, Affinity/instrumentation , Humans , Molecular Structure , Peptides/chemistry , Ribonuclease, Pancreatic/analysis , Serum Albumin/analysis
3.
Proteomics ; 8(21): 4593-602, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18837466

ABSTRACT

The potential of an organic monolith with incorporated titanium dioxide (TiO(2)) and zirconium dioxide (ZrO(2)) nanoparticles was evaluated for the selective enrichment of phosphorylated peptides from tryptic digests. A pipette tip was fitted with a monolith based on divinylbenzene (DVB) of highly porous structure, which allows sample to pass through the monolithic bed. The enrichment of phosphopeptides was enhanced by increasing the pipetting cycles during the sample preparation and a higher recovery could be achieved with adequate buffer systems. A complete automated process was developed for enrichment of phosphopeptides leading to high reproducibility and resulting in a robust method designed to minimize analytical variance while providing high sensitivity at high sample throughput. The effect of particle size on the selectivity of phosphopeptides was investigated by comparative studies with nano- and microscale TiO(2) and ZrO(2) powders. Eleven phosphopeptides from alpha-casein digest could be recovered by an optimized mixture of microscale TiO(2)/ZrO(2) particles, whereas nine additional phosphopeptides could be retained by the same mixture of nano-structured material. When compared to conventional immobilized metal-ion affinity chromatography and commercial phosphorylation-enrichment kits, higher selectivity was observed in case of self fabricated tips. About 20 phosphopeptides could be retained from alpha-casein and five from beta-casein digests by using TiO(2) and ZrO(2) based extraction tips. Further selectivity for phosphopeptides was demonstrated by enriching a digest of in vitro phosphorylated extracellular signal regulated kinase 1 (ERK1). Two phosphorylated peptides of ERK1 could be identified by MALDI-MS/MS measurements and a following MASCOT database search.


Subject(s)
Phosphopeptides/analysis , Proteins/metabolism , Styrenes , Titanium , Zirconium , Animals , Glutathione Transferase/genetics , Indicators and Reagents , Mitogen-Activated Protein Kinase 1/analysis , Mitogen-Activated Protein Kinase 1/genetics , Mitogen-Activated Protein Kinase 3/analysis , Mitogen-Activated Protein Kinase 3/genetics , Nanoparticles , Peptide Fragments/analysis , Phosphorylation , Porosity , Powders , Rats , Recombinant Fusion Proteins/analysis , Recombinant Fusion Proteins/genetics , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization , Tandem Mass Spectrometry , Trypsin
4.
Article in English | MEDLINE | ID: mdl-26899450

ABSTRACT

N-glycosylation profiling of glycoprotein biotherapeutics is an essential step in each phase of product development in the biopharmaceutical industry. For example, during clone selection, hundreds of clones should be analyzed quickly from limited amounts of samples. On the other hand, identification of disease related glycosylation alterations can serve as early indicators (glycobiomarkers) for various pathological conditions in the biomedical field. Therefore, there is a growing demand for rapid and easy to automate sample preparation methods for N-glycosylation analysis. In this paper, we report on the design and implementation of immobilized recombinant glutathione-S-transferase (GST) tagged PNGase F enzyme microcolumns for rapid and efficient removal of N-linked carbohydrates from glycoproteins. Digestion speed and efficiency were compared to conventional in-solution based protocols. The use of PNGase F functionalized microcolumns resulted in efficient N-glycan removal in 10min from all major N-linked glycoprotein types of: (i) neutral (IgG), (ii) highly sialylated (fetuin), and (iii) high mannose (ribonuclease B) carbohydrate containing glycoprotein standards. The approach can be readily applied to automated sample preparation systems, such as liquid handling robots.


Subject(s)
Electrophoresis, Capillary/methods , Enzymes, Immobilized/chemistry , Escherichia coli/enzymology , Glycoproteins/chemistry , Peptide-N4-(N-acetyl-beta-glucosaminyl) Asparagine Amidase/chemistry , Polysaccharides/isolation & purification , Animals , Fetuins/chemistry , Immunoglobulin G/chemistry , Recombinant Fusion Proteins/chemistry , Ribonucleases/chemistry
5.
J Chromatogr Sci ; 48(7): 525-32, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20819275

ABSTRACT

This year marks the 30th anniversary of the publication of Non-Suppressed Ion Chromatography, which is a method for the rapid separation of anions with on-line conductimetric detection. In this method, the separation column is connected directly to the conductimetric detector. This single-column method is a simpler technique than the original suppressed ion chromatography method, which requires a large suppressor column to reduce the background conductance. In the new method, the background signal is reduced to a manageable level simply by using an ion-exchange separation column of low exchange capacity that lowers the eluent concentration needed for separation. The eluent ion used for separation is chosen based on having large, bulky structure, which lowers the equivalent conductance and facilitates detection of the sample anions. This is a personal account of the initial discovery and early development of non-suppressed ion chromatography. The circumstances for the discovery are recounted by the two authors. Methods are described for determination of anions, cations with indirect detection, and techniques for increasing detection sensitivity. A fundamental equation for the prediction of ion chromatography detector response is given, and the development of several types of detection schemes for ion chromatography is discussed. Finally, the impact of non-suppressed ion chromatography is discussed together with comments on the discovery process.

6.
Anal Biochem ; 350(1): 128-37, 2006 Mar 01.
Article in English | MEDLINE | ID: mdl-16448620

ABSTRACT

This article describes a novel technique whereby fully functional proteins or multiprotein complexes are efficiently extracted from biological samples to chemically derivatized walls of fused-silica open-tube capillary columns. Proteins are eluted with very high yields into elution volumes that are smaller in volume than the internal volume of the open-tube capillary column itself, thereby achieving 100-fold increases in target protein concentrations from starting samples of less than 1 ml. The open-tube capillary columns are designed for single use; combined with the physical and chemical characteristics of the open-tube capillary column, this provides exceptional purity to the eluted proteins. Affinity-based open-tube capillary columns are demonstrated here to purify, enrich, and maintain functionality for a monomeric and dimeric enzyme, a low-abundance HeLa nuclear complex, and a light-harvesting octadecameric membrane protein complex. The design of the open-tube capillary column allows for facile direction of the processed protein sample to any number of final detection techniques and is capable of generating final protein concentrations required for many structural biology experiments. The open-tube capillary columns are also characterized by exceptional ease of use. Current designs allow for up to 10 open-tube capillary columns to be applied simultaneously with no fundamental impediments to even greater parallel operation.


Subject(s)
Chemical Fractionation/instrumentation , Chemical Fractionation/methods , Chromatography, Affinity/instrumentation , Multiprotein Complexes/isolation & purification , Bacterial Proteins/isolation & purification , Chromatography, Affinity/methods , DNA-Binding Proteins , Glutathione Transferase/isolation & purification , HeLa Cells , Heterogeneous-Nuclear Ribonucleoproteins/isolation & purification , Humans , Light-Harvesting Protein Complexes/isolation & purification , Microchemistry/instrumentation , Nuclear Matrix-Associated Proteins/isolation & purification , Octamer Transcription Factors/isolation & purification , Polypyrimidine Tract-Binding Protein/isolation & purification , RNA-Binding Proteins/isolation & purification , Rhodobacter sphaeroides/chemistry
7.
Rapid Commun Mass Spectrom ; 20(19): 2954-60, 2006.
Article in English | MEDLINE | ID: mdl-16953521

ABSTRACT

The development of support materials in mass fingerprinting is an important task required for diagnostic markers in conjunction with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). The material-based approach, which we introduced as material-enhanced laser desorption/ionization (MELDI), focuses not only on different functionalities, but also emphasizes the morphology, i.e. porosity or particle size of the carrier material. As a result, it provides a quick and sensitive platform for effective binding of peptides and proteins out of different biofluids, e.g. serum, spinal fluid, urine or cell lysates, and to subsequently analyze them with MALDI-TOF MS. This approach includes a built-in desalting step for serum protein profiling and is sensitive enough to detect proteins and peptides down to 100 fmol/microL. Here we co-polymerized glycidyl methacrylate (GMA) with divinylbenzene (DVB) using thermal polymerization to yield a GMA/DVB polymer for further modifications. Different affinities have been created, such as immobilized metal ion affinity (IDA-Cu2+), reversed-phase (RP) and anion-exchanger (AX) chromatography. The diverse derivatizations and the dispersity of the particles created by different chemical synthetic approaches were confirmed by characteristic infrared (IR) peaks. The polymerization carried out by non-stirring yielded an average pore radius of 6.1 microm (macro-pores) that enhanced the binding capacity enormously by offering enlarged surface areas. Moreover, atomic absorption spectrometry (AAS) provided the metal content loaded on iminodiacetic acid (IDA) in the case of poly(GMA/DVB)-IDA-Cu2+. To summarize, the optimized MELDI approach is sensitive in its performance, extremely fast and can be adapted to robotic systems for routine analysis, allowing sample preparation in less than 5 min in contrast to the conventional surface-enhanced laser desorption/ionization (SELDI) methods.


Subject(s)
Blood Proteins/chemistry , Cell Extracts/chemistry , Peptide Mapping/methods , Peptides/blood , Polymethacrylic Acids/chemistry , Polyvinyls/chemistry , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Carcinoma, Hepatocellular/chemistry , Carcinoma, Hepatocellular/pathology , Cell Line, Tumor , Humans , Liver Neoplasms/chemistry , Liver Neoplasms/pathology , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL