Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Pediatr Crit Care Med ; 18(5): 469-476, 2017 May.
Article in English | MEDLINE | ID: mdl-28338520

ABSTRACT

OBJECTIVES: Pediatric early warning systems using expert-derived vital sign parameters demonstrate limited sensitivity and specificity in identifying deterioration. We hypothesized that modified tools using data-driven vital sign parameters would improve the performance of a validated tool. DESIGN: Retrospective case control. SETTING: Quaternary-care children's hospital. PATIENTS: Hospitalized, noncritically ill patients less than 18 years old. Cases were defined as patients who experienced an emergent transfer to an ICU or out-of-ICU cardiac arrest. Controls were patients who never required intensive care. Cases and controls were split into training and testing groups. INTERVENTIONS: The Bedside Pediatric Early Warning System was modified by integrating data-driven heart rate and respiratory rate parameters (modified Bedside Pediatric Early Warning System 1 and 2). Modified Bedside Pediatric Early Warning System 1 used the 10th and 90th percentiles as normal parameters, whereas modified Bedside Pediatric Early Warning System 2 used fifth and 95th percentiles. MEASUREMENTS AND MAIN RESULTS: The training set consisted of 358 case events and 1,830 controls; the testing set had 331 case events and 1,215 controls. In the sensitivity analysis, 207 of the 331 testing set cases (62.5%) were predicted by the original tool versus 206 (62.2%; p = 0.54) with modified Bedside Pediatric Early Warning System 1 and 191 (57.7%; p < 0.001) with modified Bedside Pediatric Early Warning System 2. For specificity, 1,005 of the 1,215 testing set control patients (82.7%) were identified by original Bedside Pediatric Early Warning System versus 1,013 (83.1%; p = 0.54) with modified Bedside Pediatric Early Warning System 1 and 1,055 (86.8%; p < 0.001) with modified Bedside Pediatric Early Warning System 2. There was no net gain in sensitivity and specificity using either of the modified Bedside Pediatric Early Warning System tools. CONCLUSIONS: Integration of data-driven vital sign parameters into a validated pediatric early warning system did not significantly impact sensitivity or specificity, and all the tools showed lower than desired sensitivity and specificity at a single cutoff point. Future work is needed to develop an objective tool that can more accurately predict pediatric decompensation.


Subject(s)
Clinical Deterioration , Intensive Care Units, Pediatric , Patient Transfer , Vital Signs , Adolescent , Case-Control Studies , Child , Child, Preschool , Critical Care , Critical Illness , Female , Humans , Infant , Infant, Newborn , Male , Point-of-Care Testing , Retrospective Studies , Sensitivity and Specificity
2.
Am J Perinatol ; 34(10): 990-995, 2017 08.
Article in English | MEDLINE | ID: mdl-28376547

ABSTRACT

Objective This historical cohort study investigated how a shift toward a more conservative approach of awaiting spontaneous closure of the patent ductus arteriosus (PDA) in preterm infants has affected neonatal outcomes and resource utilization. Methods We retrospectively studied very low birth weight infants diagnosed with a PDA by echocardiogram (ECHO) in 2006-2008 (era 1), when medical or surgical PDA management was emphasized, to those born in 2010-2012 (era 2) when conservative PDA management was encouraged. Multiple regression analyses adjusted for gestational age were performed to assess differences in clinical outcomes and resource utilization between eras. Results More infants in era 2 (35/89, 39%) compared with era 1 (22/120, 18%) had conservative PDA management (p < 0.01). Despite no difference in surgical ligation rate, infants in era 2 had ligation later (median 24 vs. 8 days, p < 0.0001). There was no difference in clinical outcomes between eras, while number of ECHOs per patient was the only resource measure that increased in era 2 (median 3 vs. 2 ECHOs, p = 0.003). Conclusion In an era of more conservative PDA management, no increase in adverse clinical outcomes or significant change in resource utilization was found. Conservative PDA management may be a safe alternative for preterm infants.


Subject(s)
Conservative Treatment , Disease Management , Ductus Arteriosus, Patent/therapy , Health Resources/statistics & numerical data , Watchful Waiting , Birth Weight , Cardiovascular Agents/therapeutic use , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/surgery , Echocardiography , Female , Gestational Age , Humans , Indomethacin/therapeutic use , Infant, Newborn , Infant, Premature , Infant, Very Low Birth Weight , Ligation , Male , Retrospective Studies , Treatment Outcome
3.
J Inherit Metab Dis ; 39(6): 821-829, 2016 11.
Article in English | MEDLINE | ID: mdl-27488560

ABSTRACT

Hawkinsinuria is a rare disorder of tyrosine metabolism that can manifest with metabolic acidosis and growth arrest around the time of weaning off breast milk, typically followed by spontaneous resolution of symptoms around 1 year of age. The urinary metabolites hawkinsin, quinolacetic acid, and pyroglutamic acid can aid in identifying this condition, although their relationship to the clinical manifestations is not known. Herein we describe clinical and laboratory findings in two fraternal twins with hawkinsinuria who presented with failure to thrive and metabolic acidosis. Close clinical follow-up and laboratory testing revealed previously unrecognized hypoglycemia, hypophosphatemia, combined hyperlipidemia, and anemia, along with the characteristic urinary metabolites, including massive pyroglutamic aciduria. Treatment with N-acetyl-L-cysteine (NAC) restored normal growth and normalized or improved most biochemical parameters. The dramatic response to NAC therapy supports the idea that glutathione depletion plays a key role in the pathogenesis of hawkinsinuria.


Subject(s)
Acetylcysteine/therapeutic use , Mixed Function Oxygenases/deficiency , Tyrosinemias/drug therapy , Acidosis/pathology , Amino Acid Metabolism, Inborn Errors/drug therapy , Amino Acid Metabolism, Inborn Errors/pathology , Female , Glutathione Synthase/deficiency , Humans , Infant, Newborn , Male , Phenotype , Twins , Tyrosinemias/pathology
4.
J Hosp Med ; 13(6): 396-398, 2018 06 01.
Article in English | MEDLINE | ID: mdl-29694462

ABSTRACT

Alarm fatigue has been linked to patient morbidity and mortality in hospitals due to delayed or absent responses to monitor alarms. We sought to describe alarm rates at 5 freestanding children's hospitals during a single day and the types of alarms and proportions of patients monitored by using a point-prevalence, cross-sectional study design. We collected audible alarms on all inpatient units and calculated overall alarm rates and rates by alarm type per monitored patient per day. We found a total of 147,213 alarms during the study period, with 3-fold variation in alarm rates across hospitals among similar unit types. Across hospitals, onequarter of monitored beds were responsible for 71%, 61%, and 63% of alarms in medical-surgical, neonatal intensive care, and pediatric intensive care units, respectively. Future work focused on addressing nonactionable alarms in patients with the highest alarm counts may decrease alarm rates.


Subject(s)
Clinical Alarms/statistics & numerical data , Hospitals, Pediatric , Monitoring, Physiologic/statistics & numerical data , Child , Clinical Alarms/adverse effects , Cross-Sectional Studies , Humans , Intensive Care Units, Pediatric/statistics & numerical data
5.
Pediatrics ; 140(2)2017 Aug.
Article in English | MEDLINE | ID: mdl-28687637

ABSTRACT

OBJECTIVES: To implement data-driven vital sign parameters to reduce bedside monitor alarm burden. METHODS: Single-center, quality-improvement initiative with historical controls assessing the impact of age-based, inpatient-derived heart rate (HR) and respiratory rate (RR) parameters on a 20-bed acute care ward that serves primarily pediatric cardiology patients. The primary outcome was the number of alarms per monitored bed day (MBD) with the aim to decrease the alarms per MBD. Balancing measures included the frequency of missed rapid response team activations, acute respiratory code events, and cardiorespiratory arrest events in the unit with the new vital sign parameters. RESULTS: The median number of all cardiorespiratory monitor alarms per MBD decreased by 21% from 52 (baseline period) to 41 (postintervention period) (P < .001). This included a 17% decrease in the median HR alarms (9-7.5 per MBD) and a 53% drop in RR alarms (16.8-8.0 per MBD). There were 57 rapid response team activations, 8 acute respiratory code events, and no cardiorespiratory arrest events after the implementation of the new parameters. An evaluation of HRs and RRs recorded at the time of the event revealed that all patients with HRs and/or RRs out of range per former default parameters would also be out of range with the new parameters. CONCLUSIONS: Implementation of data-driven HR and iteratively derived RR parameters safely decreased the total alarm frequency by 21% in a pediatric acute care unit.


Subject(s)
Clinical Alarms , Heart Arrest/nursing , Heart Diseases/nursing , Patient Admission , Quality Improvement/organization & administration , Signal Processing, Computer-Assisted , Vital Signs , Adolescent , Burnout, Professional/nursing , Burnout, Professional/prevention & control , Cardiology Service, Hospital/organization & administration , Child , Child, Preschool , Female , Health Plan Implementation , Heart Rate , Humans , Infant , Male , Patient Safety , Respiratory Rate
6.
Pediatr Clin North Am ; 63(2): 251-68, 2016 Apr.
Article in English | MEDLINE | ID: mdl-27017033

ABSTRACT

Initially described more than 50 years ago, electronic health records (EHRs) are now becoming ubiquitous throughout pediatric health care settings. The confluence of increased EHR implementation and the exponential growth of digital data within them, the development of clinical informatics tools and techniques, and the growing workforce of experienced EHR users presents new opportunities to use EHRs to augment clinical discovery and improve pediatric patient care. This article reviews the basic concepts surrounding EHR-enabled research and clinical discovery, including the types and fidelity of EHR data elements, EHR data validation/corroboration, and the steps involved in analytical interrogation.


Subject(s)
Biomedical Research , Electronic Health Records , Medical Informatics , Child , Humans
7.
J Hosp Med ; 11(2): 136-44, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26663904

ABSTRACT

BACKGROUND: Alarm fatigue from frequent nonactionable physiologic monitor alarms is frequently named as a threat to patient safety. PURPOSE: To critically examine the available literature relevant to alarm fatigue. DATA SOURCES: Articles published in English, Spanish, or French between January 1980 and April 2015 indexed in PubMed, Cumulative Index to Nursing and Allied Health Literature, Scopus, Cochrane Library, Google Scholar, and ClinicalTrials.gov. STUDY SELECTION: Articles focused on hospital physiologic monitor alarms addressing any of the following: (1) the proportion of alarms that are actionable, (2) the relationship between alarm exposure and nurse response time, and (3) the effectiveness of interventions in reducing alarm frequency. DATA EXTRACTION: We extracted data on setting, collection methods, proportion of alarms determined to be actionable, nurse response time, and associations between interventions and alarm rates. DATA SYNTHESIS: Our search produced 24 observational studies focused on alarm characteristics and response time and 8 studies evaluating interventions. Actionable alarm proportion ranged from <1% to 36% across a range of hospital settings. Two studies showed relationships between high alarm exposure and longer nurse response time. Most intervention studies included multiple components implemented simultaneously. Although studies varied widely, and many had high risk of bias, promising but still unproven interventions include widening alarm parameters, instituting alarm delays, and using disposable electrocardiographic wires or frequently changed electrocardiographic electrodes. CONCLUSIONS: Physiologic monitor alarms are commonly nonactionable, and evidence supporting the concept of alarm fatigue is emerging. Several interventions have the potential to reduce alarms safely, but more rigorously designed studies with attention to possible unintended consequences are needed.


Subject(s)
Clinical Alarms , Monitoring, Physiologic/methods , Patient Safety , Clinical Alarms/adverse effects , Clinical Alarms/statistics & numerical data , Electrocardiography/methods , Hospitals , Humans , Nursing Staff, Hospital , Time Factors
8.
J Hosp Med ; 11(12): 817-823, 2016 12.
Article in English | MEDLINE | ID: mdl-27411896

ABSTRACT

INTRODUCTION: Modification of alarm limits is one approach to mitigating alarm fatigue. We aimed to create and validate heart rate (HR) and respiratory rate (RR) percentiles for hospitalized children, and analyze the safety of replacing current vital sign reference ranges with proposed data-driven, age-stratified 5th and 95th percentile values. METHODS: In this retrospective cross-sectional study, nurse-charted HR and RR data from a training set of 7202 hospitalized children were used to develop percentile tables. We compared 5th and 95th percentile values with currently accepted reference ranges in a validation set of 2287 patients. We analyzed 148 rapid response team (RRT) and cardiorespiratory arrest (CRA) events over a 12-month period, using HR and RR values in the 12 hours prior to the event, to determine the proportion of patients with out-of-range vitals based upon reference versus data-driven limits. RESULTS: There were 24,045 (55.6%) fewer out-of-range measurements using data-driven vital sign limits. Overall, 144/148 RRT and CRA patients had out-of-range HR or RR values preceding the event using current limits, and 138/148 were abnormal using data-driven limits. Chart review of RRT and CRA patients with abnormal HR and RR per current limits considered normal by data-driven limits revealed that clinical status change was identified by other vital sign abnormalities or clinical context. CONCLUSIONS: A large proportion of vital signs in hospitalized children are outside presently used norms. Safety evaluation of data-driven limits suggests they are as safe as those currently used. Implementation of these parameters in physiologic monitors may mitigate alarm fatigue. Journal of Hospital Medicine 2015;11:817-823. © 2015 Society of Hospital Medicine.


Subject(s)
Child, Hospitalized , Clinical Alarms/standards , Safety Management/methods , Vital Signs , Adolescent , Child , Child, Preschool , Cross-Sectional Studies , Heart Arrest/prevention & control , Heart Rate , Hospital Rapid Response Team , Humans , Infant , Infant, Newborn , Pediatrics , Reference Values , Respiratory Rate , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL