ABSTRACT
Background Coronary CT angiography is a first-line test in coronary artery disease but is limited by severe calcifications. Photon-counting-detector (PCD) CT improves spatial resolution. Purpose To investigate the effect of improved spatial resolution on coronary stenosis assessment and reclassification. Materials and Methods Coronary stenoses were evaluated prospectively in a vessel phantom (in vitro) containing two stenoses (25%, 50%), and retrospectively in patients (in vivo) who underwent ultrahigh-spatial-resolution cardiac PCD CT (from July 2022 to April 2023). Images were reconstructed at standard resolution (section thickness, 0.6 mm; increment, 0.4 mm; Bv44 kernel), high spatial resolution (section thickness, 0.4 mm; increment, 0.2 mm; Bv44 kernel), and ultrahigh spatial resolution (section thickness, 0.2; increment, 0.1 mm; Bv64 kernel). Percentages of diameter stenosis (DS) were compared between reconstructions. In vitro values were compared with the manufacturer specifications of the phantom and patient results were assessed regarding effects on Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification. Results The in vivo sample included 114 patients (mean age, 68 years ± 9 [SD]; 71 male patients). In vitro percentage DS measurements were more accurate with increasing spatial resolution for both 25% and 50% stenoses (mean bias for standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 10.1%, 8.0%, and 2.3%; P < .001). In vivo results confirmed decreasing median percentage DS with increasing spatial resolution for calcified stenoses (n = 161) (standard resolution, high spatial resolution, and ultrahigh spatial resolution, respectively: 41.5% [IQR, 27.3%-58.2%], 34.8% [IQR, 23.7%-55.1%], and 26.7% [IQR, 18.6%-44.3%]; P < .001), whereas noncalcified (n = 13) and mixed plaques (n = 19) did not show evidence of a difference (P ≥ .88). Ultrahigh-spatial-resolution reconstructions led to reclassification of 62 of 114 (54.4%) patients to lower CAD-RADS category than that assigned using standard resolution. Conclusion In vivo and in vitro coronary stenosis assessment improved for calcified stenoses by using ultrahigh-spatial-resolution PCD CT reconstructions, leading to lower percentage DS compared with standard resolution and clinically relevant rates of reclassification. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by McCollough in this issue.
Subject(s)
Coronary Artery Disease , Coronary Stenosis , Humans , Male , Aged , Coronary Artery Disease/diagnostic imaging , Constriction, Pathologic , Computed Tomography Angiography , Retrospective Studies , Coronary Stenosis/diagnostic imaging , Tomography, X-Ray Computed , Coronary AngiographyABSTRACT
BACKGROUND: Diagnosing myocarditis relies on multimodal data, including cardiovascular magnetic resonance (CMR), clinical symptoms, and blood values. The correct interpretation and integration of CMR findings require radiological expertise and knowledge. We aimed to investigate the performance of Generative Pre-trained Transformer 4 (GPT-4), a large language model, for report-based medical decision-making in the context of cardiac MRI for suspected myocarditis. METHODS: This retrospective study includes CMR reports from 396 patients with suspected myocarditis and eight centers, respectively. CMR reports and patient data including blood values, age, and further clinical information were provided to GPT-4 and radiologists with 1 (resident 1), 2 (resident 2), and 4 years (resident 3) of experience in CMR and knowledge of the 2018 Lake Louise Criteria. The final impression of the report regarding the radiological assessment of whether myocarditis is present or not was not provided. The performance of Generative pre-trained transformer 4 (GPT-4) and the human readers were compared to a consensus reading (two board-certified radiologists with 8 and 10 years of experience in CMR). Sensitivity, specificity, and accuracy were calculated. RESULTS: GPT-4 yielded an accuracy of 83%, sensitivity of 90%, and specificity of 78%, which was comparable to the physician with 1 year of experience (R1: 86%, 90%, 84%, p = 0.14) and lower than that of more experienced physicians (R2: 89%, 86%, 91%, p = 0.007 and R3: 91%, 85%, 96%, p < 0.001). GPT-4 and human readers showed a higher diagnostic performance when results from T1- and T2-mapping sequences were part of the reports, for residents 1 and 3 with statistical significance (p = 0.004 and p = 0.02, respectively). CONCLUSION: GPT-4 yielded good accuracy for diagnosing myocarditis based on CMR reports in a large dataset from multiple centers and therefore holds the potential to serve as a diagnostic decision-supporting tool in this capacity, particularly for less experienced physicians. Further studies are required to explore the full potential and elucidate educational aspects of the integration of large language models in medical decision-making.
ABSTRACT
BACKGROUND. Calcium blooming causes stenosis overestimation on coronary CTA. OBJECTIVE. The purpose of this article was to evaluate the impact of virtual monoenergetic imaging (VMI) reconstruction level on coronary artery stenosis quantification using photon-counting detector (PCD) CT. METHODS. A phantom containing two custom-made vessels (representing 25% and 50% stenosis) underwent PCD CT acquisitions without and with simulated cardiac motion. A retrospective analysis was performed of 33 patients (seven women, 26 men; mean age, 71.3 ± 9.0 [SD] years; 64 coronary artery stenoses) who underwent coronary CTA by PCD CT followed by invasive coronary angiography (ICA). Scans were reconstructed at nine VMI energy levels (40-140 keV). Percentage diameter stenosis (PDS) was measured, and bias was determined from the ground-truth stenosis percentage in the phantom and ICA-derived quantitative coronary angiography measurements in patients. Extent of blooming artifact was measured in the phantom and in calcified and mixed plaques in patients. RESULTS. In the phantom, PDS decreased for 25% stenosis from 59.9% (40 keV) to 13.4% (140 keV) and for 50% stenosis from 81.6% (40 keV) to 42.3% (140 keV). PDS showed lowest bias for 25% stenosis at 90 keV (bias, 1.4%) and for 50% stenosis at 100 keV (bias, -0.4%). Blooming artifacts decreased for 25% stenosis from 61.5% (40 keV) to 35.4% (140 keV) and for 50% stenosis from 82.7% (40 keV) to 52.1% (140 keV). In patients, PDS for calcified plaque decreased from 70.8% (40 keV) to 57.3% (140 keV), for mixed plaque decreased from 69.8% (40 keV) to 56.3% (140 keV), and for noncalcified plaque was 46.6% at 40 keV and 54.6% at 140 keV. PDS showed lowest bias for calcified plaque at 100 keV (bias, 17.2%), for mixed plaque at 140 keV (bias, 5.0%), and for noncalcified plaque at 40 keV (bias, -0.5%). Blooming artifacts decreased for calcified plaque from 78.4% (40 keV) to 48.6% (140 keV) and for mixed plaque from 73.1% (40 keV) to 44.7% (140 keV). CONCLUSION. For calcified and mixed plaque, stenosis severity measurements and blooming artifacts decreased at increasing VMI reconstruction levels. CLINICAL IMPACT. PCD CT with VMI reconstruction helps overcome current limitations in stenosis quantification on coronary CTA.
Subject(s)
Coronary Stenosis , Plaque, Atherosclerotic , Male , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Computed Tomography Angiography/methods , Retrospective Studies , Constriction, Pathologic , Tomography, X-Ray Computed/methods , Coronary Stenosis/diagnostic imagingABSTRACT
BACKGROUND: Four-dimensional (4D) flow MRI allows for the quantification of complex flow patterns; however, its clinical use is limited by its inherently long acquisition time. Compressed sensing (CS) is an acceleration technique that provides substantial reduction in acquisition time. PURPOSE: To compare intracardiac flow measurements between conventional and CS-based highly accelerated 4D flow acquisitions. STUDY TYPE: Prospective. SUBJECTS: Fifty healthy volunteers (28.0 ± 7.1 years, 24 males). FIELD STRENGTH/SEQUENCE: Whole heart time-resolved 3D gradient echo with three-directional velocity encoding (4D flow) with conventional parallel imaging (factor 3) as well as CS (factor 7.7) acceleration at 3 T. ASSESSMENT: 4D flow MRI data were postprocessed by applying a valve tracking algorithm. Acquisition times, flow volumes (mL/cycle) and diastolic function parameters (ratio of early to late diastolic left ventricular peak velocities [E/A] and ratio of early mitral inflow velocity to mitral annular early diastolic velocity [E/e']) were quantified by two readers. STATISTICAL TESTS: Paired-samples t-test and Wilcoxon rank sum test to compare measurements. Pearson correlation coefficient (r), Bland-Altman-analysis (BA) and intraclass correlation coefficient (ICC) to evaluate agreement between techniques and readers. A P value < 0.05 was considered statistically significant. RESULTS: A significant improvement in acquisition time was observed using CS vs. conventional accelerated acquisition (6.7 ± 1.3 vs. 12.0 ± 1.3 min). Net forward flow measurements for all valves showed good correlation (r > 0.81) and agreement (ICCs > 0.89) between conventional and CS acceleration, with 3.3%-8.3% underestimation by the CS technique. Evaluation of diastolic function showed 3.2%-17.6% error: E/A 2.2 [1.9-2.4] (conventional) vs. 2.3 [2.0-2.6] (CS), BA bias 0.08 [-0.81-0.96], ICC 0.82; and E/e' 4.6 [3.9-5.4] (conventional) vs. 3.8 [3.4-4.3] (CS), BA bias -0.90 [-2.31-0.50], ICC 0.89. DATA CONCLUSION: Analysis of intracardiac flow patterns and evaluation of diastolic function using a highly accelerated 4D flow sequence prototype is feasible, but it shows underestimation of flow measurements by approximately 10%. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.
Subject(s)
Imaging, Three-Dimensional , Magnetic Resonance Imaging , Male , Humans , Prospective Studies , Blood Flow Velocity , Imaging, Three-Dimensional/methods , Mitral Valve/diagnostic imaging , Reproducibility of ResultsABSTRACT
OBJECTIVES: Cardiac involvement in Anderson-Fabry disease (AFD) results in myocardial lipid depositions. An early diagnosis can maximize therapeutic benefit. Thus, this study aims to investigate the potential of cardiac MRI (CMR) based parameters of left atrial (LA) function and strain to detect early stages of AFD. METHODS: Patients (n = 58, age 40 (29-51) years, 31 female) with genetically proven AFD had undergone CMR including left ventricular (LV) volumetry, mass index (LVMi), T1, and late gadolinium enhancement, complemented by LA and LV strain measurements and atrial emptying fractions. Patients were stratified into three disease phases and compared to age and sex-matched healthy controls (HC, n = 58, age 41 [26-56] years, 31 female). RESULTS: A total of 19 early-, 20 intermediate-, and 19 advanced-phase patients were included. LV and LA reservoir strain was significantly impaired in all AFD phases, including early disease (both p < 0.001). In contrast, LA volumetry, T1, and LVMi showed no significant differences between the early phase and HC (p > 0.05). In the intermediate phase, LVMi and T1 demonstrated significant differences. In advanced phase, all parameters except active emptying fractions differed significantly from HC. ROC curve analyses of early disease phases revealed superior diagnostic confidence for the LA reservoir strain (AUC 0.88, sensitivity 89%, specificity 75%) over the LV strain (AUC 0.82). CONCLUSIONS: LA reservoir strain showed impairment in early AFD and significantly correlated with disease severity. The novel approach performed better in identifying early disease than the established approach using LVMi and T1. Further studies are needed to evaluate whether these results justify earlier initiation of therapy and help minimize cardiac complications. KEY POINTS: ⢠Parameters of left atrial function and deformation showed impairments in the early stages of Anderson-Fabry disease and correlated significantly with the severity of Anderson-Fabry disease. ⢠Left atrial reservoir strain performed superior to ventricular strain in detecting early myocardial involvement in Anderson-Fabry disease and improved diagnostic accuracies of approaches already using ventricular strain. ⢠Further studies are needed to evaluate whether earlier initiation of enzyme replacement therapy based on these results can help minimize cardiac complications from Anderson-Fabry disease.
Subject(s)
Atrial Fibrillation , Fabry Disease , Heart Diseases , Humans , Female , Adult , Fabry Disease/diagnostic imaging , Fabry Disease/complications , Contrast Media , Gadolinium , Heart Atria/diagnostic imaging , Heart Diseases/complicationsABSTRACT
BACKGROUND: MRI T2 mapping has been proven to be sensitive to the level of blood oxygenation. We hypothesized that impaired exercise capacity in chronic heart failure is associated with a greater difference between right (RV) to left ventricular (LV) blood pool T2 relaxation times due to a higher level of peripheral blood desaturation, compared to patients with preserved exercise capacity and to healthy controls. METHODS: Patients with chronic heart failure (n = 70) who had undergone both cardiac MRI (CMR) and a 6-min walk test (6MWT) were retrospectively identified. Propensity score matched healthy individuals (n = 35) served as control group. CMR analyses included cine acquisitions and T2 mapping to obtain blood pool T2 relaxation times of the RV and LV. Following common practice, age- and gender-adjusted nominal distances and respective percentiles were calculated for the 6MWT. The relationship between the RV/LV T2 blood pool ratio and the results from 6MWT were evaluated by Spearman's correlation coefficients and regression analyses. Inter-group differences were assessed by independent t-tests and univariate analysis of variance. RESULTS: The RV/LV T2 ratio moderately correlated with the percentiles of nominal distances in the 6MWT (r = 0.66) while ejection fraction, end-diastolic and end-systolic volumes showed no correlation (r = 0.09, 0.07 and - 0.01, respectively). In addition, there were significant differences in the RV/LV T2 ratio between patients with and without significant post-exercise dyspnea (p = 0.001). Regression analyses showed that RV/LV T2 ratio was an independent predictor of the distance walked and the presence of post-exercise dyspnea (p < 0.001). CONCLUSION: The proposed RV/LV T2 ratio, obtained by two simple measurements on a routinely acquired four-chamber T2 map, was superior to established parameters of cardiac function to predict exercise capacity and the presence of post-exercise dyspnea in patients with chronic heart failure.
Subject(s)
Heart Failure , Ventricular Dysfunction, Left , Humans , Retrospective Studies , Exercise Tolerance , Predictive Value of Tests , Magnetic Resonance Imaging , Heart Failure/diagnostic imaging , Stroke Volume , Ventricular Function, Left , Ventricular Function, RightABSTRACT
PURPOSE: Kidney volume is important in the management of renal diseases. Unfortunately, the currently available, semi-automated kidney volume determination is time-consuming and prone to errors. Recent advances in its automation are promising but mostly require contrast-enhanced computed tomography (CT) scans. This study aimed at establishing an automated estimation of kidney volume in non-contrast, low-dose CT scans of patients with suspected urolithiasis. METHODS: The kidney segmentation process was automated with 2D Convolutional Neural Network (CNN) models trained on manually segmented 2D transverse images extracted from low-dose, unenhanced CT scans of 210 patients. The models' segmentation accuracy was assessed using Dice Similarity Coefficient (DSC), for the overlap with manually-generated masks on a set of images not used in the training. Next, the models were applied to 22 previously unseen cases to segment kidney regions. The volume of each kidney was calculated from the product of voxel number and their volume in each segmented mask. Kidney volume results were then validated against results semi-automatically obtained by radiologists. RESULTS: The CNN-enabled kidney volume estimation took a mean of 32 s for both kidneys in a CT scan with an average of 1026 slices. The DSC was 0.91 and 0.86 and for left and right kidneys, respectively. Inter-rater variability had consistencies of ICC = 0.89 (right), 0.92 (left), and absolute agreements of ICC = 0.89 (right), 0.93 (left) between the CNN-enabled and semi-automated volume estimations. CONCLUSION: In our work, we demonstrated that CNN-enabled kidney volume estimation is feasible and highly reproducible in low-dose, non-enhanced CT scans. Automatic segmentation can thereby quantitatively enhance radiological reports.
Subject(s)
Neural Networks, Computer , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Radionuclide Imaging , Kidney/diagnostic imaging , Automation , Image Processing, Computer-Assisted/methodsABSTRACT
BACKGROUND: Left-to-right (L-R) shunts are characterized by a pathological connection between high- and low-pressure systems, leading to a mixing of oxygen-rich blood with low oxygenated blood. They are typically diagnosed by phase-contrast cardiac magnetic resonance imaging (MRI) which requires extensive planning. T2 is sensitive to blood oxygenation and may be able to detect oxygenation differences between the left (LV) and right ventricles (RV) caused by L-R shunts. PURPOSE: To test the feasibility of routine T2 mapping to detect L-R shunts. STUDY TYPE: Retrospective. POPULATION: Patients with known L-R shunts (N = 27), patients with RV disease without L-R shunts (N = 21), and healthy volunteers (HV; N = 52). FIELD STRENGTH/SEQUENCE: 1.5 and 3 T/balanced steady-state free-precession (bSSFP) sequence (cine imaging), T2-prepared bSSFP sequence (T2 mapping), and velocity sensitized gradient echo sequence (phase-contrast MRI). ASSESSMENT: Aortic (Qs) and pulmonary (Qp) flow was measured by phase-contrast imaging, and the Qp/Qs ratio was calculated as a measure of shunt severity. T2 maps were used to measure T2 in the RV and LV and the RV/LV T2 ratio was calculated. Cine imaging was used to calculate RV end-diastolic volume index (RV-EDVi). STATISTICAL TESTS: Wilcoxon test, paired t-tests, Spearmen correlation coefficient, receiver operating curve (ROC) analysis. Significance level P < 0.05. RESULTS: The Qp/Qs and T2 ratios in L-R shunt patients (1.84 ± 0.84 and 0.89 ± 0.07) were significantly higher compared to those in patients with RV disease (1.01 ± 0.03 and 0.72 ± 0.10) and in HV (1.04 ± 0.04 and 0.71 ± 0.09). A T2 ratio of >0.78 showed a sensitivity, specificity, and negative predictive value of 100%, 73.9%, and 100%, respectively, for the detection of L-R shunts. The T2 ratio was strongly correlated with the severity of the shunt (r = 0.83). DATA CONCLUSION: RV/LV T2 ratio is an imaging biomarker that may be able to detect or rule-out L-R shunts. Such a diagnostic tool may prevent unnecessary phase-contrast acquisitions in cases with RV dilatation of unknown etiology. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.
Subject(s)
Heart Ventricles , Magnetic Resonance Imaging , Aorta , Heart Ventricles/diagnostic imaging , Humans , Retrospective StudiesABSTRACT
OBJECTIVES: To compare volumetric and functional parameters of the atria derived from highly accelerated compressed sensing (CS)-based cine sequences in comparison to conventional (Conv) cine imaging. METHODS: CS and Conv cine sequences were acquired in 101 subjects (82 healthy volunteers (HV) and 19 patients with heart failure with reduced ejection fraction (HFrEF)) using a 3T MR scanner in this single-center study. Time-volume analysis of the left (LA) and right atria (RA) were performed in both sequences to evaluate atrial volumes and function (total, passive, and active emptying fraction). Inter-sequence and inter- and intra-reader agreement were analyzed using correlation, intraclass correlation (ICC), and Bland-Altman analysis. RESULTS: CS-based cine imaging led to a 69% reduction of acquisition time. There was significant difference in atrial parameters between CS and Conv cine, e.g., LA minimal volume (LAVmin) (Conv 24.0 ml (16.7-32.7), CS 25.7 ml (19.2-35.2), p < 0.0001) or passive emptying fraction (PEF) (Conv 53.9% (46.7-58.4), CS 49.0% (42.0-54.1), p < 0.0001). However, there was high correlation between the techniques, yielding good to excellent ICC (0.76-0.99) and small mean of differences in Bland-Altman analysis (e.g. LAVmin - 2.0 ml, PEF 3.3%). Measurements showed high inter- (ICC > 0.958) and intra-rater (ICC > 0.934) agreement for both techniques. CS-based parameters (PEF AUC = 0.965, LAVmin AUC = 0.864) showed equivalent diagnostic ability compared to Conv cine imaging (PEF AUC = 0.989, LAVmin AUC = 0.859) to differentiate between HV and HFrEF. CONCLUSION: Atrial volumetric and functional evaluation using CS cine imaging is feasible with relevant reduction of acquisition time, therefore strengthening the role of CS in clinical CMR for atrial imaging. KEY POINTS: ⢠Reliable assessment of atrial volumes and function based on compressed sensing cine imaging is feasible. ⢠Compressed sensing reduces scan time and has the potential to overcome obstacles of conventional cine imaging. ⢠No significant differences for subjective image quality, inter- and intra-rater agreement, and ability to differentiate healthy volunteers and heart failure patients were detected between conventional and compressed sensing cine imaging.
Subject(s)
Heart Failure , Acceleration , Heart Atria/diagnostic imaging , Humans , Image Interpretation, Computer-Assisted , Magnetic Resonance Imaging, Cine , Reproducibility of Results , Stroke VolumeABSTRACT
Structured reporting (SR) not only offers advantages regarding report quality but, as an IT-based method, also the opportunity to aggregate and analyze large, highly structured datasets (data mining). In this study, a data mining algorithm was used to calculate epidemiological data and in-hospital prevalence statistics of pulmonary embolism (PE) by analyzing structured CT reports.All structured reports for PE CT scans from the last 5 years (n = 2790) were extracted from the SR database and analyzed. The prevalence of PE was calculated for the entire cohort and stratified by referral type and clinical referrer. Distributions of the manifestation of PEs (central, lobar, segmental, subsegmental, as well as left-sided, right-sided, bilateral) were calculated, and the occurrence of right heart strain was correlated with the manifestation.The prevalence of PE in the entire cohort was 24% (n = 678). The median age of PE patients was 71 years (IQR 58-80), and the sex distribution was 1.2/1 (M/F). Outpatients showed a lower prevalence of 23% compared to patients from regular wards (27%) and intensive care units (30%). Surgically referred patients had a higher prevalence than patients from internal medicine (34% vs. 22%). Patients with central and bilateral PEs had a significantly higher occurrence of right heart strain compared to patients with peripheral and unilateral embolisms.Data mining of structured reports is a simple method for obtaining prevalence statistics, epidemiological data, and the distribution of disease characteristics, as demonstrated by the PE use case. The generated data can be helpful for multiple purposes, such as for internal clinical quality assurance and scientific analyses. To benefit from this, consistent use of SR is required and is therefore recommended. · SR-based data mining allows simple epidemiologic analyses for PE.. · The prevalence of PE differs between outpatients and inpatients.. · Central and bilateral PEs have an increased risk of right heart strain.. · Jorg T, Halfmann MC, Graafen D et al. Structured reporting for efficient epidemiological and in-hospital prevalence analysis of pulmonary embolisms. Fortschr Röntgenstr 2024; DOI 10.1055/a-2301-3349.
ABSTRACT
OBJECTIVES: Artificial intelligence (AI) has tremendous potential to help radiologists in daily clinical routine. However, a seamless, standardized, and time-efficient way of integrating AI into the radiology workflow is often lacking. This constrains the full potential of this technology. To address this, we developed a new reporting pipeline that enables automated pre-population of structured reports with results provided by AI tools. METHODS: Findings from a commercially available AI tool for chest X-ray pathology detection were sent to an IHE-MRRT-compliant structured reporting (SR) platform as DICOM SR elements and used to automatically pre-populate a chest X-ray SR template. Pre-populated AI results could be validated, altered, or deleted by radiologists accessing the SR template. We assessed the performance of this newly developed AI to SR pipeline by comparing reporting times and subjective report quality to reports created as free-text and conventional structured reports. RESULTS: Chest X-ray reports with the new pipeline could be created in significantly less time than free-text reports and conventional structured reports (mean reporting times: 66.8 s vs. 85.6 s and 85.8 s, respectively; both p < 0.001). Reports created with the pipeline were rated significantly higher quality on a 5-point Likert scale than free-text reports (p < 0.001). CONCLUSION: The AI to SR pipeline offers a standardized, time-efficient way to integrate AI-generated findings into the reporting workflow as parts of structured reports and has the potential to improve clinical AI integration and further increase synergy between AI and SR in the future. CRITICAL RELEVANCE STATEMENT: With the AI-to-structured reporting pipeline, chest X-ray reports can be created in a standardized, time-efficient, and high-quality manner. The pipeline has the potential to improve AI integration into daily clinical routine, which may facilitate utilization of the benefits of AI to the fullest. KEY POINTS: ⢠A pipeline was developed for automated transfer of AI results into structured reports. ⢠Pipeline chest X-ray reporting is faster than free-text or conventional structured reports. ⢠Report quality was also rated higher for reports created with the pipeline. ⢠The pipeline offers efficient, standardized AI integration into the clinical workflow.
ABSTRACT
PURPOSE: Studies have shown the incremental value of strain imaging in various cardiac diseases. However, reproducibility and generalizability has remained an issue of concern. To overcome this, simplified algorithms such as rapid atrioventricular strains have been proposed. This multicenter study aimed to assess the reproducibility of rapid strains in a real-world setting and identify potential predictors for higher interobserver variation. METHODS: A total of 4 sites retrospectively identified 80 patients and 80 healthy controls who had undergone cardiac magnetic resonance imaging (CMR) at their respective centers using locally available scanners with respective field strengths and imaging protocols. Strain and volumetric parameters were measured at each site and then independently re-evaluated by a blinded core lab. Intraclass correlation coefficients (ICC) and Bland-Altman plots were used to assess inter-observer agreement. In addition, backward multiple linear regression analysis was performed to identify predictors for higher inter-observer variation. RESULTS: There was excellent agreement between sites in feature-tracking and rapid strain values (ICC ≥ 0.96). Bland-Altman plots showed no significant bias. Bi-atrial feature-tracking and rapid strains showed equally excellent agreement (ICC ≥ 0.96) but broader limits of agreement (≤18.0 % vs. ≤3.5 %). Regression analysis showed that higher field strength and lower temporal resolution (>30 ms) independently predicted reduced interobserver agreement for bi-atrial strain parameters (ß = 0.38, p = 0.02 for field strength and ß = 0.34, p = 0.02 for temporal resolution). CONCLUSION: Simplified rapid left ventricular and bi-atrial strain parameters can be reliably applied in a real-world multicenter setting. Due to the results of the regression analysis, a minimum temporal resolution of 30 ms is recommended when assessing atrial deformation.
Subject(s)
Magnetic Resonance Imaging, Cine , Magnetic Resonance Imaging , Humans , Retrospective Studies , Reproducibility of Results , Magnetic Resonance Imaging, Cine/methods , Heart Atria , Observer Variation , Ventricular Function, LeftABSTRACT
BACKGROUND: Cardiac magnetic resonance imaging protocols have been adapted to fit the needs for faster, more efficient acquisitions, resulting in the development of highly accelerated, compressed sensing-based (CS) sequences. The aim of this study was to evaluate intersoftware and interacquisition differences for postprocessing software applied to both CS and conventional cine sequences. MATERIALS AND METHODS: A total of 106 individuals (66 healthy volunteers, 40 patients with dilated cardiomyopathy, 51% female, 38±17 y) underwent cardiac magnetic resonance at 3T with retrospectively gated conventional cine and CS sequences. Postprocessing was performed using 2 commercially available software solutions and 1 research prototype from 3 different developers. The agreement of clinical and feature-tracking strain parameters between software solutions and acquisition types was assessed by Bland-Altmann analyses and intraclass correlation coefficients. Differences between softwares and acquisitions were assessed using Kruskal-Wallis analysis of variances. In addition, receiver operating characteristic curve-derived cutoffs were used to evaluate whether sequence-specific cutoffs influence disease classification. RESULTS: There were significant intersoftware ( P <0.002 for all except LV end-diastolic volume per body surface area) and interacquisition differences ( P <0.02 for all except end-diastolic volume per body surface area from Neosoft, left ventricular mass per body surface area from cvi42 and TrufiStrain and global circumferential strain from Neosoft). However, the intraclass correlation coefficients between acquisitions were strong-to-excellent for all parameters (all ≥0.81). In comparing individual softwares to a pooled mean, Bland-Altmann analyses revealed smaller magnitudes of bias for cine acquisition than for CS acquisition. In addition, the application of conventional cutoffs to CS measurements did not result in the false reclassification of patients. CONCLUSION: Significantly lower magnitudes of strain and volumetric parameters were observed in retrospectively gated CS acquisitions, despite strong-to-excellent agreement amongst software solutions and acquisition types. It remains important to be aware of the acquisition type in the context of follow-up examinations, where different cutoffs might lead to misclassifications.
Subject(s)
Image Interpretation, Computer-Assisted , Magnetic Resonance Imaging, Cine , Humans , Female , Male , Retrospective Studies , Magnetic Resonance Imaging, Cine/methods , Image Interpretation, Computer-Assisted/methods , Reproducibility of Results , Heart Ventricles , Ventricular Function, LeftABSTRACT
PURPOSE: To assess the impact of different quantum iterative reconstruction (QIR) levels on objective and subjective image quality of ultra-high resolution (UHR) coronary CT angiography (CCTA) images and to determine the effect of strength levels on stenosis quantification using photon-counting detector (PCD)-CT. METHOD: A dynamic vessel phantom containing two calcified lesions (25 % and 50 % stenosis) was scanned at heart rates of 60, 80 and 100 beats per minute with a PCD-CT system. In vivo CCTA examinations were performed in 102 patients. All scans were acquired in UHR mode (slice thickness0.2 mm) and reconstructed with four different QIR levels (1-4) using a sharp vascular kernel (Bv64). Image noise, signal-to-noise ratio (SNR), sharpness, and percent diameter stenosis (PDS) were quantified in the phantom, while noise, SNR, contrast-to-noise ratio (CNR), sharpness, and subjective quality metrics (noise, sharpness, overall image quality) were assessed in patient scans. RESULTS: Increasing QIR levels resulted in significantly lower objective image noise (in vitro and in vivo: both p < 0.001), higher SNR (both p < 0.001) and CNR (both p < 0.001). Sharpness and PDS values did not differ significantly among QIRs (all pairwise p > 0.008). Subjective noise of in vivo images significantly decreased with increasing QIR levels, resulting in significantly higher image quality scores at increasing QIR levels (all pairwise p < 0.001). Qualitative sharpness, on the other hand, did not differ across different levels of QIR (p = 0.15). CONCLUSIONS: The QIR algorithm may enhance the image quality of CCTA datasets without compromising image sharpness or accurate stenosis measurements, with the most prominent benefits at the highest strength level.
Subject(s)
Computed Tomography Angiography , Coronary Angiography , Coronary Stenosis , Phantoms, Imaging , Photons , Signal-To-Noise Ratio , Humans , Computed Tomography Angiography/methods , Male , Female , Coronary Angiography/methods , Coronary Stenosis/diagnostic imaging , Middle Aged , Aged , Radiographic Image Interpretation, Computer-Assisted/methods , Reproducibility of Results , AlgorithmsABSTRACT
Preliminary work has shown that portal hypertension plays a key role for the prognosis in patients with hepatocellular carcinoma (HCC) undergoing transarterial chemoembolization (TACE). Specifically, the presence of ascites appears to be a strong negative predictor for these patients. However, it remains unclear whether different ascites volumes influence prognosis. Therefore, the aim of this work was to investigate the influence of different ascites volumes on survival for patients with HCC undergoing TACE. A total of 327 treatment-naïve patients with HCC undergoing initial TACE at our tertiary care center between 2010 and 2020 were included. In patients with ascites, the fluid was segmented, and the volume quantified by slice-wise addition using contrast-enhanced CT imaging. Median overall survival (OS) was calculated and univariate and multivariate Cox regression analysis has been performed. Ascites was present in 102 (31.9%) patients. Ascites volume as continuous variable was significantly associated with an increased hazard ratio in univariate analysis (p < 0.001) and remained an independent predictor of impaired median OS in multivariate analysis (p < 0.001). Median OS without ascites was 17.1 months, and therefore significantly longer than in patients with ascites (6.4 months, p < 0.001). When subdivided into groups of low and high ascites volume in relation to the median ascites volume, patients with low ascites volume had a significantly longer median OS (8.6 vs 3.6 months, p < 0.001). Ascites in patients with HCC undergoing TACE is strongly associated with a poor prognosis. Our results show that not only the presence but also the amount of ascites is highly relevant. Therefore, true ascites volume as opportunistic quantitative biomarker is likely to impact clinical decision-making once automated solutions become available.
Subject(s)
Ascites , Carcinoma, Hepatocellular , Chemoembolization, Therapeutic , Liver Neoplasms , Humans , Carcinoma, Hepatocellular/therapy , Carcinoma, Hepatocellular/mortality , Carcinoma, Hepatocellular/complications , Carcinoma, Hepatocellular/pathology , Liver Neoplasms/therapy , Liver Neoplasms/mortality , Liver Neoplasms/pathology , Liver Neoplasms/complications , Chemoembolization, Therapeutic/methods , Ascites/therapy , Ascites/mortality , Ascites/etiology , Male , Female , Middle Aged , Aged , Prognosis , Retrospective Studies , Tomography, X-Ray ComputedABSTRACT
BACKGROUND: Lower extremity peripheral artery disease frequently presents with calcifications which reduces the accuracy of computed tomography (CT) angiography, especially below-the-knee. Photon-counting detector (PCD)-CT offers improved spatial resolution and less calcium blooming. We aimed to identify the optimal reconstruction parameters for PCD-CT angiography of the lower legs. METHODS: Tubes with different diameters (1-5 mm) were filled with different iodine concentrations and scanned in a water container. Images were reconstructed with 0.4 mm isotropic resolution using a quantitative kernel at all available sharpness levels (Qr36 to Qr76) and using different levels of quantum iterative reconstruction (QIR-2-4). Noise and image sharpness were determined for all reconstructions. Additionally, CT angiograms of 20 patients, reconstructed with a medium (Qr44), sharp (Qr60), and ultrasharp (Qr72) kernel at QIR-2-4, were evaluated by three readers assessing noise, delineation of plaques and vessel walls, and overall quality. RESULTS: In the phantom study, increased kernel sharpness led to higher image noise (e.g., 16, 38, 77 HU for Qr44, Qr60, Qr72, and QIR-3). Image sharpness increased with increasing kernel sharpness, reaching a plateau at the medium-high level 60. Higher QIR levels decreased image noise (e.g., 51, 38, 25 HU at QIR-2-4 and Qr60) without reducing vessel sharpness. The qualitative in vivo results confirmed these findings: the sharp kernel (Qr60) with the highest QIR yielded the best overall quality. CONCLUSION: The combination of a sharpness level optimized reconstruction kernel (Qr60) and the highest QIR level yield the best image quality for PCD-CT angiography of the lower legs when reconstructed at 0.4-mm resolution. RELEVANCE STATEMENT: Using high-resolution PCD-CT angiography with optimized reconstruction parameters might improve diagnostic accuracy and confidence in peripheral artery disease of the lower legs. KEY POINTS: Effective exploitation of the potential of PCD-CT angiography requires optimized reconstruction parameters. Too soft or too sharp reconstruction kernels reduce image quality. The highest level of quantum iterative reconstruction provides the best image quality.
Subject(s)
Computed Tomography Angiography , Phantoms, Imaging , Photons , Computed Tomography Angiography/methods , Humans , Peripheral Arterial Disease/diagnostic imaging , Lower Extremity/diagnostic imaging , Lower Extremity/blood supply , Male , Leg/diagnostic imaging , Leg/blood supply , Female , Aged , Middle AgedABSTRACT
Purpose To investigate the impact of plaque size and density on virtual noncontrast (VNC)-based coronary artery calcium scoring (CACS) using photon-counting detector CT and to provide safety net reconstructions for improved detection of subtle plaques in patients whose VNC-based CACS would otherwise be erroneously zero when compared with true noncontrast (TNC)-based CACS. Materials and Methods In this prospective study, CACS was evaluated in a phantom containing calcifications with different diameters (5, 3, and 1 mm) and densities (800, 400, and 200 mg/cm3) and in participants who underwent TNC and contrast-enhanced cardiac photon-counting detector CT (July 2021-March 2022). VNC images were reconstructed at different virtual monoenergetic imaging (55-80 keV) and quantum iterative reconstruction (QIR) levels (QIR,1-4). TNC scans at 70 keV with QIR off served as the reference standard. In vitro CACS was analyzed using standard settings (3.0-mm sections, kernel Qr36, 130-HU threshold). Calcification detectability and CACS of small and low-density plaques were also evaluated using 1.0-mm sections, kernel Qr44, and 120- or 110-HU thresholds. Safety net reconstructions were defined based on background Agatston scores and evaluated in vivo in TNC plaques initially nondetectable using standard VNC reconstructions. Results The in vivo cohort included 63 participants (57.8 years ± 15.5 [SD]; 37 [59%] male, 26 [41%] female). Correlation and agreement between standard CACSVNC and CACSTNC were higher in large- and medium-sized and high- and medium-density than in low-density plaques (in vitro: intraclass correlation coefficient [ICC] ≥ 0.90; r > 0.9 vs ICC = 0.20-0.48; r = 0.5-0.6). Small plaques were not detectable using standard VNC reconstructions. Calcification detectability was highest using 1.0-mm sections, kernel Qr44, 120- and 110-HU thresholds, and QIR level of 2 or less VNC reconstructions. Compared with standard VNC, using safety net reconstructions (55 keV, QIR 2, 110-HU threshold) for in vivo subtle plaque detection led to higher detection (increased by 89% [50 of 56]) and improved correlation and agreement of CACSVNC with CACSTNC (in vivo: ICC = 0.51-0.61; r = 0.6). Conclusion Compared with TNC-based calcium scoring, VNC-based calcium scoring was limited for small and low-density plaques but improved using safety net reconstructions, which may be particularly useful in patients with low calcium scores who would otherwise be treated based on potentially false-negative results. Keywords: Coronary Artery Calcium CT, Photon-Counting Detector CT, Virtual Noncontrast, Plaque Size, Plaque Density Supplemental material is available for this article. © RSNA, 2024.
Subject(s)
Coronary Artery Disease , Phantoms, Imaging , Plaque, Atherosclerotic , Humans , Male , Female , Prospective Studies , Plaque, Atherosclerotic/diagnostic imaging , Plaque, Atherosclerotic/pathology , Middle Aged , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/pathology , Aged , Photons , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Vascular Calcification/diagnostic imaging , Vascular Calcification/pathology , Tomography, X-Ray Computed/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Coronary Angiography/methods , Contrast MediaABSTRACT
BACKGROUND: A recent simulation study proposed that stenosis measurements on coronary computed tomography (CT) angiography are influenced by the improved spatial resolution of photon-counting detector (PCD)-CT. The aim of the current study was to evaluate the impact of ultrahigh-spatial-resolution (UHR) on coronary stenosis measurements and Coronary Artery Disease Reporting and Data System (CAD-RADS) reclassification rates in patients undergoing coronary CT angiography on both PCD-CT and energy-integrating detector (EID)-CT and to compare measurements against quantitative coronary angiography. METHODS: Patients with coronary calcification on EID-CT (collimation, 192×0.6 mm) were prospectively enrolled for a research coronary CT angiography with UHR PCD-CT (collimation, 120×0.2 mm) within 30 days (between April 1, 2023 and January 31, 2024). PCD-CT was acquired with the same or lower CT dose index and equivalent contrast media volume as EID-CT. Percentage diameter stenosis (PDS) for calcified, partially calcified, and noncalcified lesions were compared between scanners. Patient-level reclassification rates for CAD-RADS were evaluated. The accuracy of PDS measurements was validated against quantitative coronary angiography in patients who underwent invasive coronary angiography. RESULTS: In total, PDS of 278 plaques were quantified in 49 patients (calcified, 202; partially calcified, 51; noncalcified, 25). PCD-CT-based PDS values were lower than EID-CT measurements for calcified (45.1±20.7 versus 54.6±19.2%; P<0.001) and partially calcified plaques (44.3±19.6 versus 54.9±20.0%; P<0.001), without significant differences for noncalcified lesions (39.1±15.2 versus 39.0±16.0%; P=0.98). The reduction in stenosis degrees led to a 49.0% (24/49) reclassification rate to a lower CAD-RADS with PCD-CT. In a subset of 12 patients with 56 lesions, UHR-based PDS values showed higher agreement with quantitative coronary angiography (mean difference, 7.3%; limits of agreement, -10.7%/25.2%) than EID-CT measurements (mean difference, 17.4%; limits of agreement, -6.9%/41.7%). CONCLUSIONS: Compared with conventional EID-CT, UHR PCD-CT results in lower PDS values and more accurate stenosis measurements in coronary plaques with calcified components and leads to a substantial Coronary Artery Disease Reporting and Data System reclassification rate in 49.0% of patients.
Subject(s)
Computed Tomography Angiography , Coronary Angiography , Coronary Stenosis , Humans , Coronary Stenosis/diagnostic imaging , Male , Female , Coronary Angiography/methods , Computed Tomography Angiography/methods , Prospective Studies , Middle Aged , Aged , Reproducibility of Results , Predictive Value of Tests , Coronary Vessels/diagnostic imaging , Photons , Severity of Illness Index , Vascular Calcification/diagnostic imagingABSTRACT
PURPOSE: To evaluate the feasibility of CT angiography-derived fractional flow reserve (CT-FFR) calculations on ultrahigh-resolution (UHR) photon-counting detector (PCD)-CT series and to intra-individually compare the results with energy-integrating (EID)-CT measurements. METHOD: Prospective patients with calcified plaques detected on EID-CT between April 1st, 2023 and January 31st, 2024 were recruited for a UHR CCTA on PCD-CT within 30 days. PCD-CT was performed using the same or a lower CT dose index and an equivalent volume of contrast media. An on-site machine learning algorithm was used to obtain CT-FFR values on a per-vessel and per-patient basis. For all analyses, CT-FFR values ≤ 0.80 were deemed to be hemodynamically significant. RESULTS: A total of 34 patients (age: 67.3 ± 6.6 years, 7 women [20.6 %]) were included. Excellent inter-scanner agreement was noted for CT-FFR values in the per-vessel (ICC: 0.93 [0.90-0.95]) and per-patient (ICC: 0.94 [0.88-0.97]) analysis. PCD-CT-derived CT-FFR values proved to be higher compared to EID-CT values on both vessel (0.58 ± 0.23 vs. 0.55 ± 0.23, p < 0.001) and patient levels (0.73 ± 0.23 vs. 0.70 ± 0.22, p < 0.001). Two patients (5.9 %) with hemodynamically significant lesions on EID-CT were reclassified as non-significant on PCD-CT. All remaining participants were classified into the same category with both scanner systems. CONCLUSIONS: While UHR CT-FFR values demonstrate excellent agreement with EID-CT measurements, PCD-CT produces higher CT-FFR values that could contribute to a reclassification of hemodynamic significance.
ABSTRACT
BACKGROUND: Advanced imaging techniques play a pivotal role in oncology. A large variety of computed tomography (CT) scanners, scan protocols, and acquisition techniques have led to a wide range in image quality and radiation exposure. This study aims at implementing verifiable oncological imaging by quality assurance and optimization (i-Violin) through harmonizing image quality and radiation dose across Europe. METHODS: The 2year multicenter implementation study outlined here will focus on CT imaging of lung, stomach, and colorectal cancer and include imaging for four radiological indications: diagnosis, radiation therapy planning, staging, and follow-up. Therefore, 480 anonymized CT data sets of patients will be collected by the associated university hospitals and uploaded to a repository. Radiologists will determine key abdominopelvic structures for image quality assessment by consensus and subsequently adapt a previously developed lung CT tool for the objective evaluation of image quality. The quality metrics will be evaluated for their correlation with perceived image quality and the standardized optimization strategy will be disseminated across Europe. RESULTS: The results of the outlined study will be used to obtain European reference data, to build teaching programs for the developed tools, and to create a culture of optimization in oncological CT imaging. CONCLUSION: The study protocol and rationale for iViolin, a European approach for standardization and harmonization of image quality and optimization of CT procedures in oncological imaging, is presented. Future results will be disseminated across all EU member states, and iViolin is thus expected to have a sustained impact on CT imaging for cancer patients across Europe.