ABSTRACT
Epicardial formation is necessary for normal myocardial morphogenesis. Here, we show that differentiating hiPSC-derived lateral plate mesoderm with BMP4, RA and VEGF (BVR) can generate a premature form of epicardial cells (termed pre-epicardial cells, PECs) expressing WT1, TBX18, SEMA3D, and SCX within 7 days. BVR stimulation after Wnt inhibition of LPM demonstrates co-differentiation and spatial organization of PECs and cardiomyocytes (CMs) in a single 2D culture. Co-culture consolidates CMs into dense aggregates, which then form a connected beating syncytium with enhanced contractility and calcium handling; while PECs become more mature with significant upregulation of UPK1B, ITGA4, and ALDH1A2 expressions. Our study also demonstrates that PECs secrete IGF2 and stimulate CM proliferation in co-culture. Three-dimensional PEC-CM spheroid co-cultures form outer smooth muscle cell layers on cardiac micro-tissues with organized internal luminal structures. These characteristics suggest PECs could play a key role in enhancing tissue organization within engineered cardiac constructs in vitro.
Subject(s)
Cell Aggregation/physiology , Coculture Techniques , Myocytes, Cardiac/physiology , Aldehyde Dehydrogenase 1 Family/metabolism , Basic Helix-Loop-Helix Transcription Factors , Bone Morphogenetic Protein 4 , Calcium/metabolism , Cell Differentiation , Genes, Wilms Tumor , Humans , Induced Pluripotent Stem Cells , Insulin-Like Growth Factor II/metabolism , Mesoderm , Myocytes, Smooth Muscle , Retinal Dehydrogenase/metabolism , Semaphorins , Stem Cells , T-Box Domain Proteins/metabolismABSTRACT
Stem cell therapy has the potential to regenerate cardiac function after myocardial infarction. In this study, we sought to examine if fibrin microthread technology could be leveraged to develop a contractile fiber from human pluripotent stem cell derived cardiomyocytes (hPS-CM). hPS-CM seeded onto fibrin microthreads were able to adhere to the microthread and began to contract seven days after initial seeding. A digital speckle tracking algorithm was applied to high speed video data (>60 fps) to determine contraction behaviour including beat frequency, average and maximum contractile strain, and the principal angle of contraction of hPS-CM contracting on the microthreads over 21 days. At day 7, cells seeded on tissue culture plastic beat at 0.83 ± 0.25 beats/sec with an average contractile strain of 4.23±0.23%, which was significantly different from a beat frequency of 1.11 ± 0.45 beats/sec and an average contractile strain of 3.08±0.19% at day 21 (n = 18, p < 0.05). hPS-CM seeded on microthreads beat at 0.84 ± 0.15 beats/sec with an average contractile strain of 3.56±0.22%, which significantly increased to 1.03 ± 0.19 beats/sec and 4.47±0.29%, respectively, at 21 days (n = 18, p < 0.05). At day 7, 27% of the cells had a principle angle of contraction within 20 degrees of the microthread, whereas at day 21, 65% of hPS-CM were contracting within 20 degrees of the microthread (n = 17). Utilizing high speed calcium transient data (>300 fps) of Fluo-4AM loaded hPS-CM seeded microthreads, conduction velocities significantly increased from 3.69 ± 1.76 cm/s at day 7 to 24.26 ± 8.42 cm/s at day 21 (n = 5-6, p < 0.05). hPS-CM seeded microthreads exhibited positive expression for connexin 43, a gap junction protein, between cells. These data suggest that the fibrin microthread is a suitable scaffold for hPS-CM attachment and contraction. In addition, extended culture allows cells to contract in the direction of the thread, suggesting alignment of the cells in the microthread direction.
ABSTRACT
Differentiation of human pluripotent stem cells into cardiomyocytes (hPS-CMs) holds promise for myocardial regeneration therapies, drug discovery, and models of cardiac disease. Potential cardiotoxicities may affect hPS-CM mechanical contraction independent of calcium signaling. Herein, a method using an image capture system is described to measure hPS-CM contractility and intracellular calcium concurrently, with high spatial and temporal resolution. The image capture system rapidly alternates between brightfield and epifluorescent illumination of contracting cells. Mechanical contraction is quantified by a speckle tracking algorithm applied to brightfield image pairs, whereas calcium transients are measured by a fluorescent calcium reporter. This technique captured changes in contractile strain, calcium transients, and beat frequency of hPS-CMs over 21 days in culture, as well as acute responses to isoproterenol and Cytochalasin D. The technique described above can be applied without the need to alter the culture platform, allowing for determination of hPS-CM behavior over weeks in culture for drug discovery and myocardial regeneration applications.
Subject(s)
Calcium/metabolism , Myocardial Contraction , Myocytes, Cardiac/metabolism , Optics and Photonics/methods , Pluripotent Stem Cells/cytology , Aniline Compounds/metabolism , Biomechanical Phenomena/drug effects , Fluorescence , Humans , Isoproterenol/pharmacology , Myocardial Contraction/drug effects , Myocytes, Cardiac/cytology , Myocytes, Cardiac/drug effects , Pluripotent Stem Cells/drug effects , Time Factors , Xanthenes/metabolismABSTRACT
The ability to modulate the mechanical properties, and cell alignment within a cardiac patch without hindering cell functionality may have significant impact on developing therapies for treating myocardial infarctions. We developed fibrin-based composite layers comprising aligned microthreads distributed uniformly throughout a hydrogel. Increasing the microthread volume fraction (â¼5%, 11% and 22%) significantly increased the moduli of the scaffolds (20.6 ± 8.1, 46.4 ± 23.0, and 97.5 ± 49.3 kPa, respectively), p < 0.05. Analyses of cell-mediated contractile strains and frequencies showed no significant differences among composite layers and fibrin hydrogel controls, suggesting that microthread-based composite layers exhibit similar active functional properties. Cell orientation in composite layers suggests an increase in nuclear alignment within 100 µm of fibrin microthreads and suggests that microthreads influence the alignment in adjacent areas. In this study, we developed composite layers with tunable, mechanical patch properties that improve cell alignment and support cell functionality.
ABSTRACT
Current cardiac cell therapies cannot effectively target and retain cells in a specific area of the heart. Cell-seeded biological sutures were previously developed to overcome this limitation, demonstrating targeted delivery with > 60% cell retention. In this study, both cell-seeded and non-seeded fibrin-based biological sutures were implanted into normal functioning rat hearts to determine the effects on mechanical function and fibrotic response. Human mesenchymal stem cells (hMSCs) were used based on previous work and established cardioprotective effects. Non-seeded or hMSC-seeded sutures were implanted into healthy athymic rat hearts. Before cell seeding, hMSCs were passively loaded with quantum dot nanoparticles. One week after implantation, regional stroke work index and systolic area of contraction (SAC) were evaluated on the epicardial surface above the suture. Cell delivery and retention were confirmed by quantum dot tracking, and the fibrotic tissue area was evaluated. Non-seeded biological sutures decreased SAC near the suture from 0.20 ± 0.01 measured in sham hearts to 0.08 ± 0.02, whereas hMSC-seeded biological sutures dampened the decrease in SAC (0.15 ± 0.02). Non-seeded sutures also displayed a small amount of fibrosis around the sutures (1.0 ± 0.1 mm2 ). Sutures seeded with hMSCs displayed a significant reduction in fibrosis (0.5 ± 0.1 mm2 , p < 0.001), with quantum dot-labelled hMSCs found along the suture track. These results show that the addition of hMSCs attenuates the fibrotic response observed with non-seeded sutures, leading to improved regional mechanics of the implantation region. Copyright © 2014 John Wiley & Sons, Ltd.
Subject(s)
Heart/physiology , Mesenchymal Stem Cell Transplantation/methods , Mesenchymal Stem Cells/cytology , Sutures , Animals , Cell Differentiation , Cell Survival , Cell Transplantation , Fibrin/pharmacology , Fibrosis , Humans , Male , Quantum Dots , Rats , Rats, Nude , Stress, Mechanical , Tissue Engineering , Tissue ScaffoldsABSTRACT
Despite significant advances in the fabrication of bioengineered scaffolds for tissue engineering, delivery of nutrients in complex engineered human tissues remains a challenge. By taking advantage of the similarities in the vascular structure of plant and animal tissues, we developed decellularized plant tissue as a prevascularized scaffold for tissue engineering applications. Perfusion-based decellularization was modified for different plant species, providing different geometries of scaffolding. After decellularization, plant scaffolds remained patent and able to transport microparticles. Plant scaffolds were recellularized with human endothelial cells that colonized the inner surfaces of plant vasculature. Human mesenchymal stem cells and human pluripotent stem cell derived cardiomyocytes adhered to the outer surfaces of plant scaffolds. Cardiomyocytes demonstrated contractile function and calcium handling capabilities over the course of 21 days. These data demonstrate the potential of decellularized plants as scaffolds for tissue engineering, which could ultimately provide a cost-efficient, "green" technology for regenerating large volume vascularized tissue mass.
Subject(s)
Perfusion/methods , Plant Leaves/chemistry , Plant Vascular Bundle/chemistry , Stem Cells/cytology , Stem Cells/physiology , Tissue Engineering/instrumentation , Tissue Scaffolds , Batch Cell Culture Techniques/instrumentation , Cell-Free System/chemistry , Cells, Cultured , Equipment Design , Extracellular Matrix/chemistry , Humans , Petroselinum/chemistry , Spinacia oleracea/chemistry , Tissue Engineering/methodsABSTRACT
Stem cell therapy has the potential to improve cardiac function after myocardial infarction (MI); however, existing methods to deliver cells to the myocardium, including intramyocardial injection, suffer from low engraftment rates. In this study, we used a rat model of acute MI to assess the effects of human mesenchymal stem cell (hMSC)-seeded fibrin biological sutures on cardiac function at 1 week after implant. Biological sutures were seeded with quantum dot (Qdot)-loaded hMSCs for 24 h before implantation. At 1 week postinfarct, the heart was imaged to assess mechanical function in the infarct region. Regional parameters assessed were regional stroke work (RSW) and systolic area of contraction (SAC) and global parameters derived from the pressure waveform. MI (n = 6) significantly decreased RSW (0.026 ± 0.011) and SAC (0.022 ± 0.015) when compared with sham operation (RSW: 0.141 ± 0.009; SAC: 0.166 ± 0.005, n = 6) (p < 0.05). The delivery of unseeded biological sutures to the infarcted hearts did not change regional mechanical function compared with the infarcted hearts (RSW: 0.032 ± 0.004, SAC: 0.037 ± 0.008, n = 6). The delivery of hMSC-seeded sutures exerted a trend toward increase of regional mechanical function compared with the infarcted heart (RSW: 0.057 ± 0.011; SAC: 0.051 ± 0.014, n = 6). Global function showed no significant differences between any group (p > 0.05); however, there was a trend toward improved function with the addition of either unseeded or seeded biological suture. Histology demonstrated that Qdot-loaded hMSCs remained present in the infarcted myocardium after 1 week. Analysis of serial sections of Masson's trichrome staining revealed that the greatest infarct size was in the infarct group (7.0% ± 2.2%), where unseeded (3.8% ± 0.6%) and hMSC-seeded (3.7% ± 0.8%) suture groups maintained similar infarct sizes. Furthermore, the remaining suture area was significantly decreased in the unseeded group compared with that in the hMSC-seeded group (p < 0.05). This study demonstrated that hMSC-seeded biological sutures are a method to deliver cells to the infarcted myocardium and have treatment potential.