Magn Reson Med ; 91(1): 19-27, 2024 01.
Article in English | MEDLINE | ID: mdl-37772616

ABSTRACT

PURPOSE: To develop prospective motion correction for single-voxel MRS in the human cervical spinal cord. METHODS: A motion MR navigator was implemented using reduced field-of-view 2D-selective RF excitation together with EPI readout. A short-echo semi-LASER sequence (TE = 30 ms) was updated to incorporate this real-time image-based motion navigator, as well as real-time shim and frequency navigators. Five healthy participants were studied at 3 T with a 64-channel head-neck receive coil. Single-voxel MRS data were measured in a voxel located at the C3-5 vertebrae level. The motion navigator was used to correct for translations in the X-Y plane and was validated by assessing spectral quality with and without prospective correction in the presence of subject motion. RESULTS: Without prospective correction, motion resulted in severe lipid contamination in the MR spectra. With prospective correction, the quality of spinal cord MR spectra in the presence of motion was similar to that obtained in the absence of motion, with comparable spectral signal-to-noise ratio and linewidth and no significant lipid contamination. CONCLUSION: Prospective motion and B0 correction allow acquisition of good-quality MR spectra in the human cervical spinal cord in the presence of motion. This new technique should facilitate reliable acquisition of spinal cord MR spectra in both research and clinical settings.


Subject(s)
Cervical Cord , Humans , Cervical Cord/diagnostic imaging , Prospective Studies , Motion , Spinal Cord , Lipids , Artifacts , Brain , Magnetic Resonance Imaging
2.
Magn Reson Med ; 91(4): 1301-1313, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38084392

ABSTRACT

PURPOSE: To develop a fast high-resolution image-based motion correction method using spiral navigators with multislice-to-volume registration. METHODS: A semi-LASER sequence was modified to include a multislice spiral navigator for prospective motion correction (∼305 ms including acquisition, processing, and feedback) as well as shim and frequency navigators for prospective shim and frequency correction (∼100 ms for each). MR spectra were obtained in the prefrontal cortex in five healthy subjects at 3 T with and without prospective motion and shim correction. The effect of key navigator parameters (number of slices, image resolution, and excitation flip angle) on registration accuracy was assessed using simulations. RESULTS: Without prospective motion and shim correction, spectral quality degraded significantly in the presence of voluntary motion. In contrast, with prospective motion and shim correction, spectral quality was improved (metabolite linewidth = 6.7 ± 0.6 Hz, SNR= 67 ± 9) and in good agreement with baseline data without motion (metabolite linewidth = 6.9 ± 0.9 Hz, SNR = 73 ± 9). In addition, there was no significant difference in metabolites concentrations measured without motion and with prospective motion and shim correction in the presence of motion. Simulations showed that the registration precision was comparable when using three navigator slices with 3 mm resolution and when using the entire volume (all slices) with 8 mm resolution. CONCLUSION: The proposed motion correction scheme allows fast and precise prospective motion and shim correction for single-voxel spectroscopy at 3 T. With 3 mm resolution, only a few navigator slices are necessary to achieve excellent motion correction performance.


Subject(s)
Artifacts , Brain , Humans , Brain/diagnostic imaging , Brain/metabolism , Prospective Studies , Motion , Spectrum Analysis , Magnetic Resonance Imaging
3.
Magn Reson Med ; 92(4): 1338-1347, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38704666

ABSTRACT

PURPOSE: Localized shimming in single-voxel MRS often results in large B0 inhomogeneity outside the volume-of-interest. This causes unacceptable degradation in motion navigator images. Switching back and forth between whole-brain shim and localized shim is possible for linear shims, but not for higher-order shims. Here we propose motion navigators largely insensitive to B0 inhomogeneity for prospective motion-corrected MRS with localized higher-order shimming. METHODS: A recent fast high-resolution motion navigator based on spiral-in/out k-space trajectories and multislice-to-volume registration was modified by splitting the readout into multiple shot interleaves which shortened the echo time and reduced the effect of B0 inhomogeneity. The performance of motion correction was assessed in healthy subjects in the prefrontal cortex using a sLASER sequence at 3T (N = 5) and 7T (N = 5). RESULTS: With multiple spatial interleaves, excellent quality navigator images were acquired in the whole brain in spite of large B0 inhomogeneity outside the MRS voxel. The total duration of the navigator in sLASER remained relatively short even with multiple shots (3T: 10 spatial interleaves 94 ms per slice; 7T: 15 spatial interleaves 103 ms per slice). Prospective motion correction using the multi-shot navigators yielded comparable spectral quality (water linewidth and metabolite SNR) with and without subject motion. CONCLUSION: B0-insensitive motion navigators enable prospective motion correction for MRS with all first- and second-order shims adjusted in the MRS voxel, providing optimal spectral linewidth.


Subject(s)
Algorithms , Motion , Humans , Magnetic Resonance Spectroscopy/methods , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Image Processing, Computer-Assisted/methods , Artifacts , Male , Adult , Female , Reproducibility of Results , Prefrontal Cortex/diagnostic imaging , Sensitivity and Specificity
4.
Mov Disord ; 38(1): 45-56, 2023 01.
Article in English | MEDLINE | ID: mdl-36308733

ABSTRACT

BACKGROUND: Spinal cord damage is a hallmark of Friedreich's ataxia (FRDA), but its progression and clinical correlates remain unclear. OBJECTIVE: The objective of this study was to perform a characterization of cervical spinal cord structural damage in a large multisite FRDA cohort. METHODS: We performed a cross-sectional analysis of cervical spinal cord (C1-C4) cross-sectional area (CSA) and eccentricity using magnetic resonance imaging data from eight sites within the ENIGMA-Ataxia initiative, including 256 individuals with FRDA and 223 age- and sex-matched control subjects. Correlations and subgroup analyses within the FRDA cohort were undertaken based on disease duration, ataxia severity, and onset age. RESULTS: Individuals with FRDA, relative to control subjects, had significantly reduced CSA at all examined levels, with large effect sizes (d > 2.1) and significant correlations with disease severity (r < -0.4). Similarly, we found significantly increased eccentricity (d > 1.2), but without significant clinical correlations. Subgroup analyses showed that CSA and eccentricity are abnormal at all disease stages. However, although CSA appears to decrease progressively, eccentricity remains stable over time. CONCLUSIONS: Previous research has shown that increased eccentricity reflects dorsal column (DC) damage, while decreased CSA reflects either DC or corticospinal tract (CST) damage, or both. Hence our data support the hypothesis that damage to the DC and damage to CST follow distinct courses in FRDA: developmental abnormalities likely define the DC, while CST alterations may be both developmental and degenerative. These results provide new insights about FRDA pathogenesis and indicate that CSA of the cervical spinal cord should be investigated further as a potential biomarker of disease progression. © 2022 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.


Subject(s)
Friedreich Ataxia , Movement Disorders , Humans , Friedreich Ataxia/complications , Friedreich Ataxia/pathology , Ataxia , Magnetic Resonance Imaging/methods , Pyramidal Tracts
5.
Cerebellum ; 2023 Jun 06.
Article in English | MEDLINE | ID: mdl-37280482

ABSTRACT

With many viable strategies in the therapeutic pipeline, upcoming clinical trials in hereditary and sporadic degenerative ataxias will benefit from non-invasive MRI biomarkers for patient stratification and the evaluation of therapies. The MRI Biomarkers Working Group of the Ataxia Global Initiative therefore devised guidelines to facilitate harmonized MRI data acquisition in clinical research and trials in ataxias. Recommendations are provided for a basic structural MRI protocol that can be used for clinical care and for an advanced multi-modal MRI protocol relevant for research and trial settings. The advanced protocol consists of modalities with demonstrated utility for tracking brain changes in degenerative ataxias and includes structural MRI, magnetic resonance spectroscopy, diffusion MRI, quantitative susceptibility mapping, and resting-state functional MRI. Acceptable ranges of acquisition parameters are provided to accommodate diverse scanner hardware in research and clinical contexts while maintaining a minimum standard of data quality. Important technical considerations in setting up an advanced multi-modal protocol are outlined, including the order of pulse sequences, and example software packages commonly used for data analysis are provided. Outcome measures most relevant for ataxias are highlighted with use cases from recent ataxia literature. Finally, to facilitate access to the recommendations by the ataxia clinical and research community, examples of datasets collected with the recommended parameters are provided and platform-specific protocols are shared via the Open Science Framework.

6.
Magn Reson Med ; 87(6): 2613-2620, 2022 06.
Article in English | MEDLINE | ID: mdl-35092085

ABSTRACT

PURPOSE: Advanced MRS protocols improve data quality and reproducibility relative to vendor-provided protocols; however, they are challenging to incorporate into the clinical workflow and require local MRS expertise for successful implementation. Here, we developed an automated advanced MRS acquisition protocol at 3T to facilitate acquisition of high-quality spectroscopic data without local MRS expertise. METHODS: First, a B0 shimming protocol was selected for automation by comparing 3 widely used B0 algorithms (2 vendor protocols and FAST(EST)MAP). Next, voxel-based B0 and B1 calibrations were incorporated into the consensus-recommended semi-LASER sequence and combined with an automated VOI prescription tool, a recently developed method for automated voxel prescription. The efficiency of collecting single-voxel data from a clinical cohort (N = 40) with the automated protocol (calibration time and fraction of usable datasets) was compared with the nonautomated semi-LASER protocol (N = 35) whereby all prescan calibrations were executed manually in the academic hospital setting with rotating MR technologists in the neuroradiology unit. RESULTS: A multi-iteration FAST(EST)MAP protocol resulted in narrower water linewidths than vendor's B0 shim protocols for data acquired from 6 brain locations (p < 1e-5) and was selected for automation. The automated B0 and B1 calibrations resulted in a time saving of ~4.5 minutes per voxel relative to the same advanced protocol executed manually. All spectra acquired with the automated protocol were usable, whereas only 86% of those collected with the manual protocol were usable and spectral quality was more variable. CONCLUSION: The plug-and-play advanced MRS protocol allows automated acquisition of high-quality MRS data with high success rate and consistency on a clinical 3T platform.


Subject(s)
Brain , Magnetic Resonance Imaging , Algorithms , Brain/diagnostic imaging , Humans , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy/methods , Reproducibility of Results
7.
Ann Neurol ; 90(4): 570-583, 2021 10.
Article in English | MEDLINE | ID: mdl-34435700

ABSTRACT

OBJECTIVE: Friedreich ataxia (FRDA) is an inherited neurological disease defined by progressive movement incoordination. We undertook a comprehensive characterization of the spatial profile and progressive evolution of structural brain abnormalities in people with FRDA. METHODS: A coordinated international analysis of regional brain volume using magnetic resonance imaging data charted the whole-brain profile, interindividual variability, and temporal staging of structural brain differences in 248 individuals with FRDA and 262 healthy controls. RESULTS: The brainstem, dentate nucleus region, and superior and inferior cerebellar peduncles showed the greatest reductions in volume relative to controls (Cohen d = 1.5-2.6). Cerebellar gray matter alterations were most pronounced in lobules I-VI (d = 0.8), whereas cerebral differences occurred most prominently in precentral gyri (d = 0.6) and corticospinal tracts (d = 1.4). Earlier onset age predicted less volume in the motor cerebellum (rmax  = 0.35) and peduncles (rmax  = 0.36). Disease duration and severity correlated with volume deficits in the dentate nucleus region, brainstem, and superior/inferior cerebellar peduncles (rmax  = -0.49); subgrouping showed these to be robust and early features of FRDA, and strong candidates for further biomarker validation. Cerebral white matter abnormalities, particularly in corticospinal pathways, emerge as intermediate disease features. Cerebellar and cerebral gray matter loss, principally targeting motor and sensory systems, preferentially manifests later in the disease course. INTERPRETATION: FRDA is defined by an evolving spatial profile of neuroanatomical changes beyond primary pathology in the cerebellum and spinal cord, in line with its progressive clinical course. The design, interpretation, and generalization of research studies and clinical trials must consider neuroanatomical staging and associated interindividual variability in brain measures. ANN NEUROL 2021;90:570-583.


Subject(s)
Brain/pathology , Friedreich Ataxia/diagnostic imaging , Image Processing, Computer-Assisted , Adult , Age of Onset , Brain/anatomy & histology , Disease Progression , Female , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , Pyramidal Tracts/pathology , Young Adult
8.
NMR Biomed ; 34(5): e4199, 2021 05.
Article in English | MEDLINE | ID: mdl-31658398

ABSTRACT

γ-aminobutyric acid (GABA) was the first molecule that was edited with MEGA-PRESS. GABA edited spectroscopy is challenged by limited selectivity of editing pulses. Coediting of resonances from macromolecules (MM) is the greatest single limitation of GABA edited spectroscopy. In this contribution, relative signal contributions from GABA, MM and homocarnosine to the total MEGA-PRESS edited signal at ~3 ppm, i.e., GABA+, are simulated at 3 tesla using several acquisition schemes. The base scheme is modeled after those currently supplied by vendors: it uses typical pulse shapes and lengths, it minimizes the first echo time (TE), and the delay between the editing pulses is kept at TE/2. Edited spectra are simulated for imperfect acquisition parameters such as incorrect frequency, larger chemical shift displacement, incorrect transmit B1 -field calibration for localization and editing pulses, and longer TE. An alternative timing scheme and longer editing pulses are also considered. Additional simulations are performed for symmetric editing around the MM frequency to suppress the MM signal. The relative influences of these acquisition parameters on the constituents of GABA+ are examined from the perspective of modern experimental designs for investigating brain GABA concentration differences in healthy and diseased humans. Other factors that influence signal contributions, such as T1 and T2 relaxation times are also considered.


Subject(s)
Magnetic Resonance Spectroscopy , gamma-Aminobutyric Acid/analysis , Carnosine/analogs & derivatives , Carnosine/analysis , Computer Simulation , Humans , Macromolecular Substances/analysis
9.
NMR Biomed ; : e4325, 2020 Aug 26.
Article in English | MEDLINE | ID: mdl-33565219

ABSTRACT

In vivo MRS is a non-invasive measurement technique used not only in humans, but also in animal models using high-field magnets. MRS enables the measurement of metabolite concentrations as well as metabolic rates and their modifications in healthy animals and disease models. Such data open the way to a deeper understanding of the underlying biochemistry, related disturbances and mechanisms taking place during or prior to symptoms and tissue changes. In this work, we focus on the main preclinical 1H, 31P and 13C MRS approaches to study brain metabolism in rodent models, with the aim of providing general experts' consensus recommendations (animal models, anesthesia, data acquisition protocols). An overview of the main practical differences in preclinical compared with clinical MRS studies is presented, as well as the additional biochemical information that can be obtained in animal models in terms of metabolite concentrations and metabolic flux measurements. The properties of high-field preclinical MRS and the technical limitations are also described.

10.
Magn Reson Med ; 82(6): 1984-1992, 2019 12.
Article in English | MEDLINE | ID: mdl-31297889

ABSTRACT

PURPOSE: To demonstrate feasibility and performance of prospective motion and B0 shim correction for MRS in human brain at 7T. METHODS: Prospective motion correction using an optical camera and linear B0 shim correction using FASTMAP-like navigators were implemented into a semi-LASER sequence. The effect of motion on spectral quality was assessed without and with prospective correction in prefrontal cortex in 11 subjects. RESULTS: Without prospective motion and shim correction, motion resulted in considerable degradation of MR spectra (broader linewidth, lower signal-to-noise ratio, degraded water suppression). With prospective motion and shim correction, spectral quality remained excellent despite motion. Prospective motion correction alone was not sufficient to prevent degradation of spectral quality. CONCLUSION: Prospective motion and B0 shim correction is feasible at 7T and should help improve the robustness of MRS, particularly in motion-prone populations.


Subject(s)
Brain/diagnostic imaging , Image Processing, Computer-Assisted/methods , Magnetic Resonance Spectroscopy , Motion , Adult , Aged , Algorithms , Artifacts , Female , Healthy Volunteers , Humans , Male , Middle Aged , Optics and Photonics , Prefrontal Cortex/diagnostic imaging , Signal-To-Noise Ratio
12.
NMR Biomed ; 31(12): e4012, 2018 12.
Article in English | MEDLINE | ID: mdl-30276897

ABSTRACT

Carbon-13 NMR spectroscopy (13 C MRS) offers the unique capability to measure brain metabolic rates in vivo. Hyperpolarized 13 C reduces the time required to assess brain metabolism from hours to minutes when compared with conventional 13 C MRS. This study investigates metabolism of hyperpolarized [1-13 C]pyruvate and [2-13 C]pyruvate in the rat brain in vivo under various anesthetics: pentobarbital, isoflurane, α-chloralose, and morphine. The apparent metabolic rate from pyruvate to lactate modeled using time courses obtained after injection of hyperpolarized [1-13 C]pyruvate was significantly greater for isoflurane than for all other anesthetic conditions, and significantly greater for morphine than for α-chloralose. The apparent metabolic rate from pyruvate to bicarbonate was significantly greater for morphine than for all other anesthetic conditions, and significantly lower for pentobarbital than for α-chloralose. Results show that relative TCA cycle rates determined from hyperpolarized 13 C data are consistent with rates previously measured using conventional 13 C MRS under similar anesthetic conditions, and that using morphine for sedation greatly improves detection of downstream metabolic products compared with other anesthetics.


Subject(s)
Anesthesia , Brain/metabolism , Carbon Isotopes/chemistry , Pyruvic Acid/metabolism , Animals , Kinetics , Male , Rats, Sprague-Dawley
13.
NMR Biomed ; 31(3)2018 03.
Article in English | MEDLINE | ID: mdl-29315899

ABSTRACT

The striatum is a well-known region affected in Huntington disease (HD). However, other regions, including the visual cortex, are implicated. We have identified previously an abnormal energy response in the visual cortex of patients at an early stage of HD using 31 P magnetic resonance spectroscopy (31 P MRS). We therefore sought to further characterize these metabolic alterations with 1 H MRS using a well-validated semi-localized by adiabatic selective refocusing (semi-LASER) sequence that allows the measurement of an expanded number of neurometabolites. Ten early affected patients [Unified Huntington Disease Rating Scale (UHDRS), total motor score = 13.6 ± 10.8] and 10 healthy volunteers of similar age and body mass index (BMI) were recruited for the study. We performed 1 H MRS in the striatum - the region that is primarily affected in HD - and the visual cortex. The protocol allowed a reliable quantification of 10 metabolites in the visual cortex and eight in the striatum, compared with three to five metabolites in previous 1 H MRS studies performed in HD. We identified higher total creatine (p < 0.05) in the visual cortex and lower glutamate (p < 0.001) and total creatine (p < 0.05) in the striatum of patients with HD compared with controls. Less abundant neurometabolites [glutamine, γ-aminobutyric acid (GABA), glutathione, aspartate] showed similar concentrations in both groups. The protocol allowed the measurement of several additional metabolites compared with standard vendor protocols. Our study points to early changes in metabolites involved in energy metabolism in the visual cortex and striatum of patients with HD. Decreased striatal glutamate could reflect early neuronal dysfunction or impaired glutamatergic neurotransmission.


Subject(s)
Huntington Disease/diagnostic imaging , Huntington Disease/metabolism , Metabolome , Proton Magnetic Resonance Spectroscopy , Adult , Female , Humans , Male , Middle Aged , Neostriatum/diagnostic imaging , Neostriatum/metabolism , Visual Cortex/diagnostic imaging , Visual Cortex/metabolism
15.
J Biol Chem ; 291(10): 5157-71, 2016 Mar 04.
Article in English | MEDLINE | ID: mdl-26703469

ABSTRACT

A network model for the determination of tumor metabolic fluxes from (13)C NMR kinetic isotopomer data has been developed and validated with perfused human DB-1 melanoma cells carrying the BRAF V600E mutation, which promotes oxidative metabolism. The model generated in the bonded cumomer formalism describes key pathways of tumor intermediary metabolism and yields dynamic curves for positional isotopic enrichment and spin-spin multiplets. Cells attached to microcarrier beads were perfused with 26 mm [1,6-(13)C2]glucose under normoxic conditions at 37 °C and monitored by (13)C NMR spectroscopy. Excellent agreement between model-predicted and experimentally measured values of the rates of oxygen and glucose consumption, lactate production, and glutamate pool size validated the model. ATP production by glycolytic and oxidative metabolism were compared under hyperglycemic normoxic conditions; 51% of the energy came from oxidative phosphorylation and 49% came from glycolysis. Even though the rate of glutamine uptake was ∼ 50% of the tricarboxylic acid cycle flux, the rate of ATP production from glutamine was essentially zero (no glutaminolysis). De novo fatty acid production was ∼ 6% of the tricarboxylic acid cycle flux. The oxidative pentose phosphate pathway flux was 3.6% of glycolysis, and three non-oxidative pentose phosphate pathway exchange fluxes were calculated. Mass spectrometry was then used to compare fluxes through various pathways under hyperglycemic (26 mm) and euglycemic (5 mm) conditions. Under euglycemic conditions glutamine uptake doubled, but ATP production from glutamine did not significantly change. A new parameter measuring the Warburg effect (the ratio of lactate production flux to pyruvate influx through the mitochondrial pyruvate carrier) was calculated to be 21, close to upper limit of oxidative metabolism.


Subject(s)
Melanoma/metabolism , Oxidative Phosphorylation , Adenosine Triphosphate/metabolism , Carbon-13 Magnetic Resonance Spectroscopy , Cell Line, Tumor , Citric Acid Cycle , Glucose/metabolism , Glutamine/metabolism , Humans , Models, Theoretical , Mutation, Missense , Oxygen/metabolism , Proto-Oncogene Proteins B-raf/genetics
16.
J Magn Reson Imaging ; 45(3): 681-691, 2017 03.
Article in English | MEDLINE | ID: mdl-27402249

ABSTRACT

PURPOSE: To evaluate the feasibility of using a clinical magnetic resonance (MR) system and MR spectroscopy (MRS) to measure glucose concentration changes in the human hypothalamus, a structure central to whole-body glucose regulation. SUBJECTS AND METHODS: A time series of MR spectra (semi-LASER, TE = 28 msec), localized to the bilateral hypothalamus (∼1.6 ml) were obtained at 3T in six healthy subjects at baseline (euglycemia) and during a ∼65-70-minute-long hyperglycemic clamp in 11-minute blocks with interleaved T1 FLASH images to retrospectively assess head motion, and track changes in cerebrospinal fluid (CSF) partial volume. The LCModel was used to quantify the sum of glucose and taurine concentrations, [Glc+Tau], along with their associated Cramér-Rao lower bounds (CRLB). RESULTS: Spectral quality allowed quantification of [Glc+Tau] (sum reported due to high negative correlation between these metabolites) with CRLB <25% in 35/36 timepoints during hyperglycemia. Increased [Glc+Tau] was observed with hyperglycemia in all subjects, but most reliably in those with plasma glucose targets ≥300 mg/dl. For these subjects, [Glc+Tau]baseline (n = 4) was 1.5 (±0.3, SD) mM, and increased to 4.5 (±1.1) mM (n = 16) for timepoints acquired ≥25 minutes after onset of the clamp, with 15/16 timepoints having no overlap of 95% confidence intervals (CIs) between baseline and hyperglycemia. Preliminary analysis revealed a linear (1:5) relationship between hypothalamus-blood glucose concentrations. CONCLUSION: It is feasible to measure glucose concentration changes in the human hypothalamus using a standard 3T scanner and a short-echo semi-LASER sequence by utilizing retrospective motion tracking, CSF correction, predetermined quality acceptance criteria, and hyperglycemic blood glucose levels ≥300 mg/dl. LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017;45:681-691.


Subject(s)
Glucose/metabolism , Hyperglycemia/diagnostic imaging , Hyperglycemia/metabolism , Hypothalamus/diagnostic imaging , Hypothalamus/metabolism , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy/methods , Adult , Feasibility Studies , Female , Glucose Clamp Technique , Humans , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Male , Molecular Imaging/methods , Reproducibility of Results , Sensitivity and Specificity , Tissue Distribution
17.
Magn Reson Med ; 73(1): 13-20, 2015 Jan.
Article in English | MEDLINE | ID: mdl-24436256

ABSTRACT

PURPOSE: To investigate the effect of Carr-Purcell (CP) pulse trains on transverse relaxation times, T2, of tissue water and metabolites (both noncoupled and J-coupled spins) in the rat brain at 9.4 Tesla (T) using LASER, CP-LASER, and T2ρ-LASER sequences. METHODS: Proton NMR spectra were measured in rat brain in vivo at 9.4T. Spectra were acquired at multiple echo times ranging from 18 to 402 ms. All spectra were analyzed using LCModel with simulated basis sets. Signals of metabolites as a function of echo time were fitted using a mono-exponential function to determine their T2 relaxation times. RESULTS: Measured T2 s for tissue water and all metabolites were significantly longer with CP-LASER and T2ρ-LASER compared with LASER. The T2 increased by a factor of ∼ 1.3 for noncoupled and weakly coupled spins (e.g., N-acetylaspartate and total creatine) and by a factor of ∼ 2 (e.g., glutamine and taurine) to ∼ 4 (e.g., glutamate and myo-inositol) for strongly coupled spins. CONCLUSION: Application of a CP pulse train results in a larger increase in T2 relaxation times for strongly coupled spins than for noncoupled (singlet) and weakly coupled spins. This needs to be taken into account when correcting for T2 relaxation in CP-like sequences such as LASER.


Subject(s)
Brain/metabolism , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy/methods , Molecular Imaging/methods , Algorithms , Animals , Brain/anatomy & histology , Male , Rats , Rats, Sprague-Dawley , Reproducibility of Results , Sensitivity and Specificity , Signal Processing, Computer-Assisted , Tissue Distribution
18.
Magn Reson Med ; 73(5): 1718-25, 2015 May.
Article in English | MEDLINE | ID: mdl-24948590

ABSTRACT

PURPOSE: To determine whether neurochemical concentrations obtained at two MRI sites using clinical 3T scanners can be pooled when a highly optimized, nonvendor short-echo, single-voxel proton MRS pulse sequence is used in conjunction with identical calibration and quantification procedures. METHODS: A modified semi-LASER sequence (TE = 28 ms) was used to acquire spectra from two brain regions (cerebellar vermis and pons) on two Siemens 3T scanners using the same B0 and B1 calibration protocols from two different cohorts of healthy volunteers (N = 24-33 per site) matched for age and body mass index. Spectra were quantified with LCModel using water scaling. RESULTS: The spectral quality was very consistent between the two sites and allowed reliable quantification of at least 13 metabolites in the vermis and pons compared with 3-5 metabolites in prior multisite magnetic resonance spectroscopy trials using vendor-provided sequences. The neurochemical profiles were nearly identical at the two sites and showed the feasibility to detect interindividual differences in the healthy brain. CONCLUSION: Highly reproducible neurochemical profiles can be obtained on different clinical 3T scanners at different sites, provided that the same, optimized acquisition and analysis techniques are used. This will allow pooling of multisite data in clinical studies, which is particularly critical for rare neurological diseases.


Subject(s)
Cerebellar Vermis/physiology , Energy Metabolism/physiology , Image Interpretation, Computer-Assisted/methods , Pons/physiology , Proton Magnetic Resonance Spectroscopy/methods , Adult , Aged , Female , Humans , Male , Middle Aged , Reference Values , Sensitivity and Specificity
19.
NMR Biomed ; 28(6): 633-41, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25871439

ABSTRACT

Quantification of (31)P NMR spectra is commonly performed using line-fitting techniques with prior knowledge. Currently available time- and frequency-domain analysis software includes AMARES (in jMRUI) and CFIT respectively. Another popular frequency-domain approach is LCModel, which has been successfully used to fit both (1)H and (13)C in vivo NMR spectra. To the best of our knowledge LCModel has not been used to fit (31)P spectra. This study demonstrates the feasibility of using LCModel to quantify in vivo (31)P MR spectra, provided that adequate prior knowledge and LCModel control parameters are used. Both single-voxel and MRSI data are presented, and similar results are obtained with LCModel and with AMARES. This provides a new method for automated, operator-independent analysis of (31)P NMR spectra.


Subject(s)
Algorithms , Brain/metabolism , Magnetic Resonance Spectroscopy/methods , Models, Biological , Phosphorus Compounds/metabolism , Phosphorus Isotopes/pharmacokinetics , Animals , Computer Simulation , Humans , Magnetic Resonance Imaging/methods , Mice , Models, Chemical , Reproducibility of Results , Sensitivity and Specificity
20.
Mov Disord ; 30(5): 662-70, 2015 Apr 15.
Article in English | MEDLINE | ID: mdl-25773989

ABSTRACT

Spinocerebellar ataxias (SCAs) belong to polyglutamine repeat disorders and are characterized by a predominant atrophy of the cerebellum and the pons. Proton magnetic resonance spectroscopy ((1) H MRS) using an optimized semiadiabatic localization by adiabatic selective refocusing (semi-LASER) protocol was performed at 3 T to determine metabolite concentrations in the cerebellar vermis and pons of a cohort of patients with SCA1 (n=16), SCA2 (n=12), SCA3 (n=21), and SCA7 (n=12) and healthy controls (n=33). Compared with controls, patients displayed lower total N-acetylaspartate and, to a lesser extent, lower glutamate, reflecting neuronal loss/dysfunction, whereas the glial marker, myoinositol (myo-Ins), was elevated. Patients also showed higher total creatine as reported in Huntington's disease, another polyglutamine repeat disorder. A strong correlation was found between the Scale for the Assessment and Rating of Ataxia and the neurometabolites in both affected regions of patients. Principal component analyses confirmed that neuronal metabolites (total N-acetylaspartate and glutamate) were inversely correlated in the vermis and the pons to glial (myo-Ins) and energetic (total creatine) metabolites, as well as to disease severity (motor scales). Neurochemical plots with selected metabolites also allowed the separation of SCA2 and SCA3 from controls. The neurometabolic profiles detected in patients underlie cell-specific changes in neuronal and astrocytic compartments that cannot be assessed by other neuroimaging modalities. The inverse correlation between metabolites from these two compartments suggests a metabolic attempt to compensate for neuronal damage in SCAs. Because these biomarkers reflect dynamic aspects of cellular metabolism, they are good candidates for proof-of-concept therapeutic trials. © 2015 International Parkinson and Movement Disorder Society.


Subject(s)
Aspartic Acid/analogs & derivatives , Glutamic Acid/metabolism , Magnetic Resonance Spectroscopy , Spinocerebellar Ataxias/classification , Spinocerebellar Ataxias/metabolism , Adult , Aspartic Acid/metabolism , Ataxins/genetics , Ataxins/metabolism , Cohort Studies , Female , Humans , Machado-Joseph Disease , Male , Middle Aged , Principal Component Analysis , Protons , Spinocerebellar Ataxias/genetics , Statistics as Topic
SELECTION OF CITATIONS