Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters

Database
Country/Region as subject
Language
Publication year range
1.
Phys Rev Lett ; 103(14): 140601, 2009 Oct 02.
Article in English | MEDLINE | ID: mdl-19905555

ABSTRACT

We report on residual-gas damping of the motion of a macroscopic test mass enclosed in a nearby housing in the molecular flow regime. The damping coefficient, and thus the associated thermal force noise, is found to increase significantly when the distance between the test mass and surrounding walls is smaller than the test mass itself. The effect has been investigated with two torsion pendulums of different geometry and has been modeled in a numerical simulation whose predictions are in good agreement with the measurements. Relevant to a wide variety of small-force experiments, the residual-gas force noise power for the test masses in the LISA gravitational wave observatory is roughly a factor 15 larger than in an infinite gas volume, though still compatible with the target acceleration noise of 3 fm s(-2) Hz(-1/2) at the foreseen pressure below 10(-6) Pa.

2.
Rev Sci Instrum ; 88(7): 073901, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28764504

ABSTRACT

Brownian thermal noise generated by mechanical losses in thin film coatings limits the sensitivity of gravitational wave detectors, as well as several high precision metrology experiments. Improving the sensitivity of the next generation of gravitational wave detectors will require optical coatings with significantly reduced mechanical losses. In this paper, we describe a system that we developed to measure the mechanical loss angle of thin film coatings deposited on fused silica substrates. The novelty of this system resides in the capability of parallel measurement of up to four samples and the ability to simultaneously probe all the resonant modes of each sample. This high throughput measurement system allows the exploration of a large number of deposition and material parameters, which can be tuned to achieve low loss coatings.

3.
Rev Sci Instrum ; 86(8): 084501, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26329213

ABSTRACT

It has been reported that treating music wire (high carbon steel wire) by cooling to cryogenic temperatures can enhance its mechanical properties with particular reference to those properties important for musical performance. We use such wire for suspending many of the optics in Advanced LIGO, the upgrade to LIGO­the Laser Interferometric Gravitational-Wave Observatory. Two properties that particularly interest us are mechanical loss and breaking strength. A decrease in mechanical loss would directly reduce the thermal noise associated with the suspension, thus enhancing the noise performance of mirror suspensions within the detector. An increase in strength could allow thinner wire to be safely used, which would enhance the dilution factor of the suspension, again leading to lower suspension thermal noise. In this article, we describe the results of an investigation into some of the mechanical properties of music wire, comparing untreated wire with the same wire which has been cryogenically treated. For the samples we studied, we conclude that there is no significant difference in the properties of interest for application in gravitational wave detectors.

4.
Rev Sci Instrum ; 82(4): 044502, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21529026

ABSTRACT

Detection of gravitational waves from astrophysical sources remains one of the most challenging problems faced by experimental physicists. A significant limit to the sensitivity of future long-baseline interferometric gravitational wave detectors is thermal displacement noise of the test mass mirrors and their suspensions. Suspension thermal noise results from mechanical dissipation in the fused silica suspension fibers suspending the test mass mirrors and is therefore an important noise source at operating frequencies between ∼10 and 30 Hz. This dissipation occurs due to a combination of thermoelastic damping, surface and bulk losses. Its effects can be reduced by optimizing the thermoelastic and surface loss, and these parameters are a function of the cross sectional dimensions of the fiber along its length. This paper presents a new apparatus capable of high resolution measurements of the cross sectional dimensions of suspension fibers of both rectangular and circular cross section, suitable for use in advanced detector mirror suspensions.

5.
Rev Sci Instrum ; 82(1): 011301, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21280809

ABSTRACT

In 2000 the first mirror suspensions to use a quasi-monolithic final stage were installed at the GEO600 detector site outside Hannover, pioneering the use of fused silica suspension fibers in long baseline interferometric detectors to reduce suspension thermal noise. Since that time, development of the production methods of fused silica fibers has continued. We present here a review of a novel CO(2) laser-based fiber pulling machine developed for the production of fused silica suspensions for the next generation of interferometric gravitational wave detectors and for use in experiments requiring low thermal noise suspensions. We discuss tolerances, strengths, and thermal noise performance requirements for the next generation of gravitational wave detectors. Measurements made on fibers produced using this machine show a 0.8% variation in vertical stiffness and 0.05% tolerance on length, with average strengths exceeding 4 GPa, and mechanical dissipation which meets the requirements for Advanced LIGO thermal noise performance.

6.
NATNEWS ; 22(5): 23-6, 1985 May.
Article in English | MEDLINE | ID: mdl-3848663
SELECTION OF CITATIONS
SEARCH DETAIL