Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Journal subject
Publication year range
1.
Appl Opt ; 58(14): 3775-3783, 2019 May 10.
Article in English | MEDLINE | ID: mdl-31158190

ABSTRACT

In this study, we report on the three-dimensional (3D) characterization of a spray in terms of its droplet Sauter mean diameter (SMD) using the laser-induced fluorescence (LIF)/Mie ratio technique. The spray structure is analyzed for a multi-hole direct-injection spark ignition (DISI) injector. A calibration curve to convert the LIF/Mie ratio to droplet diameter is deduced using LIF/Mie imaging and analysis of single droplets generated by a droplet generator. The DISI spray investigated here is optically sectioned by means of two-phase structured laser illumination planar imaging to suppress the intensity of multiple light scattering from LIF and Mie images prior to their ratio. A series of calibrated LIF/Mie ratio images of spray is then recorded at several depths along the z direction following the light sheet scanning of the spray. The droplet SMD ranges from less than 5 µm up to a maximum of 50 µm in single-shot images. The averaged SMD results (1-30 µm) obtained by using the calibration curve from the droplet generator are compared with measurement results from phase-Doppler anemometry. Finally, a 3D map is reconstructed from the successive 2D layers generated from spray scanning. The resulting 3D representation of the droplet SMD shows a non-symmetric spray structure produced by the studied multi-hole injector, which cannot be resolved by analyzing only one central plane.

2.
Opt Express ; 26(24): 31750-31766, 2018 Nov 26.
Article in English | MEDLINE | ID: mdl-30650756

ABSTRACT

Planar droplet sizing (PDS) is a technique relying on the assumption that laser-induced fluorescence (LIF) and Mie scattering optical signals from spherical droplets depend on their volume and surface area, respectively. In this article, we verify the validity of this assumption by experimentally analyzing the light intensity of the LIF and Mie optical signals from micrometric droplets as a function of their diameter. The size of the droplets is controlled using a new flow-focusing monodisperse droplet generator capable of producing droplets of the desired size in the range of 21 µm to 60 µm. Ethanol droplets doped with eosin dye and excited at 532 nm are considered in this study, and the individual droplets were imaged simultaneously at microscopic and macroscopic scale. The effects of laser power, dye concentration, and temperature variation are systematically studied as a function of LIF/Mie ratio in the whole range of droplet sizes. Finally, a calibration curve at tracer concentration of 0.5 vol% is deduced and used to extract the droplet Sauter mean diameter (SMD) from instantaneous images of a transient ethanol spray. This droplet size mapping is done using structured laser illumination planar imaging (SLIPI), in order to suppress the artifacts induced by multiple light scattering.

SELECTION OF CITATIONS
SEARCH DETAIL