Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 69
Filter
Add more filters

Publication year range
1.
Radiology ; 299(3): 559-567, 2021 06.
Article in English | MEDLINE | ID: mdl-33825509

ABSTRACT

Background Interval cancer rates can be used to evaluate whether screening with digital breast tomosynthesis (DBT) contributes to a screening benefit. Purpose To compare interval cancer rates and tumor characteristics in DBT screening to those in a contemporary population screened with digital mammography (DM). Materials and Methods The prospective population-based Malmö Breast Tomosynthesis Screening Trial (MBTST) was designed to compare one-view DBT to two-view DM in breast cancer detection. The interval cancer rates and cancer characteristics in the MBTST were compared with an age-matched contemporary control group, screened with two-view DM at the same center. Conditional logistic regression was used for data analysis. Results There were 14 848 women who were screened with DBT and DM in the MBTST between January 2010 and February 2015. The trial women were matched with two women of the same age and screening occasion at DM screening during the same period. Matches for 13 369 trial women (mean age, 56 years ± 10 [standard deviation]) were found with 26 738 women in the control group (mean age, 56 years ± 10). The interval cancer rate in the MBTST was 1.6 per 1000 screened women (21 of 13 369; 95% CI: 1.0, 2.4) compared with 2.8 per 1000 screened women in the control group (76 of 26 738 [95% CI: 2.2, 3.6]; conditional odds ratio, 0.6 [95% CI: 0.3, 0.9]; P = .02). The invasive interval cancers in the MBTST and in the control group showed in general high Ki-67 (63% [12 of 19] and 75% [54 of 72]), and low proportions of luminal A-like subtype (26% [five of 19] and 17% [12 of 72]), respectively. Conclusion The reduced interval cancer rate after screening with digital breast tomosynthesis compared with a contemporary age-matched control group screened with digital mammography might translate into screening benefits. Interval cancers in the trial generally had nonfavorable characteristics. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Mann in this issue.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/epidemiology , Mammography/methods , Mass Screening/methods , Adult , Aged , Breast Neoplasms/pathology , Early Detection of Cancer , Female , Humans , Middle Aged , Prospective Studies , Sweden/epidemiology
2.
J Magn Reson Imaging ; 53(3): 807-817, 2021 03.
Article in English | MEDLINE | ID: mdl-33067849

ABSTRACT

BACKGROUND: Diffusion-weighted imaging (DWI) has shown promise to screen for breast cancer without a contrast injection, but image distortion and low spatial resolution limit standard single-shot DWI. Multishot DWI methods address these limitations but introduce shot-to-shot phase variations requiring correction during reconstruction. PURPOSE: To investigate the performance of two multishot DWI reconstruction methods, multiplexed sensitivity encoding (MUSE) and shot locally low-rank (shot-LLR), compared to single-shot DWI in the breast. STUDY TYPE: Prospective. POPULATION: A total of 45 women who consented to have multishot DWI added to a clinically indicated breast MRI. FIELD STRENGTH/SEQUENCES: Single-shot DWI reconstructed by parallel imaging, multishot DWI with four or eight shots reconstructed by MUSE and shot-LLR, 3D T2 -weighted imaging, and contrast-enhanced MRI at 3T. ASSESSMENT: Three blinded observers scored images for 1) general image quality (perceived signal-to-noise ratio [SNR], ghosting, distortion), 2) lesion features (discernment and morphology), and 3) perceived resolution. Apparent diffusion coefficient (ADC) of the lesion was also measured and compared between methods. STATISTICAL TESTS: Image quality features and perceived resolution were assessed with a mixed-effects logistic regression. Agreement among observers was estimated with a Krippendorf's alpha using linear weighting. Lesion feature ratings were visualized using histograms, and correlation coefficients of lesion ADC between different methods were calculated. RESULTS: MUSE and shot-LLR images were rated to have significantly better perceived resolution (P < 0.001), higher SNR (P < 0.005), and a lower level of distortion (P < 0.05) with respect to single-shot DWI. Shot-LLR showed reduced ghosting artifacts with respect to both MUSE (P < 0.001) and single-shot DWI (P < 0.001). Eight-shot DWI had improved perceived SNR and perceived resolution with respect to four-shot DWI (P < 0.005). DATA CONCLUSION: Multishot DWI enables increased resolution and improved image quality with respect to single-shot DWI in the breast. Shot-LLR reconstructs multishot DWI with minimal ghosting artifacts. The improvement of multishot DWI in image quality increases with an increased number of shots. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Subject(s)
Diffusion Magnetic Resonance Imaging , Echo-Planar Imaging , Artifacts , Female , Humans , Magnetic Resonance Imaging , Prospective Studies , Reproducibility of Results
3.
Eur Radiol ; 31(7): 5335-5343, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33475774

ABSTRACT

OBJECTIVES: To study how radiologists' perceived ability to interpret digital mammography (DM) images is affected by decreases in image quality. METHODS: One view from 45 DM cases (including 30 cancers) was degraded to six levels each of two acquisition-related issues (lower spatial resolution and increased quantum noise) and three post-processing-related issues (lower and higher contrast and increased correlated noise) seen during clinical evaluation of DM systems. The images were shown to fifteen breast screening radiologists from five countries. Aware of lesion location, the radiologists selected the most-degraded mammogram (indexed from 1 (reference) to 7 (most degraded)) they still felt was acceptable for interpretation. The median selected index, per degradation type, was calculated separately for calcification and soft tissue (including normal) cases. Using the two-sided, non-parametric Mann-Whitney test, the median indices for each case and degradation type were compared. RESULTS: Radiologists were not tolerant to increases (medians: 1.5 (calcifications) and 2 (soft tissue)) or decreases (median: 2, for both types) in contrast, but were more tolerant to correlated noise (median: 3, for both types). Increases in quantum noise were tolerated more for calcifications than for soft tissue cases (medians: 3 vs. 4, p = 0.02). Spatial resolution losses were considered less acceptable for calcification detection than for soft tissue cases (medians: 3.5 vs. 5, p = 0.001). CONCLUSIONS: Perceived ability of radiologists for image interpretation in DM was affected not only by image acquisition-related issues but also by image post-processing issues, and some of those issues affected calcification cases more than soft tissue cases. KEY POINTS: • Lower spatial resolution and increased quantum noise affected the radiologists' perceived ability to interpret calcification cases more than soft tissue lesion or normal cases. • Post-acquisition image processing-related effects, not only image acquisition-related effects, also impact the perceived ability of radiologists to interpret images and detect lesions. • In addition to current practices, post-acquisition image processing-related effects need to also be considered during the testing and evaluation of digital mammography systems.


Subject(s)
Breast Neoplasms , Calcinosis , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Calcinosis/diagnostic imaging , Female , Humans , Mammography , Radiographic Image Enhancement , Radiologists
4.
Breast Cancer Res Treat ; 169(3): 437-446, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29423901

ABSTRACT

PURPOSE: Premenopausal physiologic steroid levels change cyclically, in contrast to steady state low levels seen in postmenopausal patients. The purpose of this study was to evaluate whether 18F-fluorodeoxyglucose (18F-FDG) uptake in breast cancer is influenced by physiological hormonal fluctuations. METHODS: A total of 160 primary invasive breast cancers from 155 females (54 premenopausal, 101 postmenopausal) who underwent 18F-FDG positron emission tomography/computed tomography before therapy were retrospectively analyzed. The maximal standardized uptake values (SUVmax) of tumors were compared with menstrual phases and menopausal status according to the following subgroups: 'luminal A-like,' 'luminal B-like,' and 'non-luminal.' Additionally, the effect of estradiol (E2) on 18F-FDG uptake in breast cancer cells was evaluated in vitro. RESULTS: Among premenopausal patients, SUVmax during the periovulatory-luteal phase was significantly higher than that during the follicular phase in luminal A-like tumors (n = 25, p = 0.004), while it did not differ between the follicular phase and the periovulatory-luteal phase in luminal B-like (n = 24) and non-luminal tumors (n = 7). Multiple regression analysis showed menstrual phase, tumor size, and Ki-67 index are independent predictors for SUVmax in premenopausal luminal A-like tumors. There were no significant differences in SUVmax between pre- and postmenopausal patients in any of the subgroups. In in vitro studies, uptake in estrogen receptor-positive cells was significantly augmented when E2 concentration was increased from 0.01 to ≥ 1 nM. CONCLUSIONS: Our data suggest that 18F-FDG uptake may be impacted by physiological hormonal fluctuations during menstrual cycle in luminal A-like cancers, and that E2 could be partly responsible for these events.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/metabolism , Fluorodeoxyglucose F18/metabolism , Hormones/metabolism , Positron-Emission Tomography , Adult , Aged , Biomarkers , Breast Neoplasms/pathology , Cell Line, Tumor , Female , Humans , Menstrual Cycle , Middle Aged , Positron Emission Tomography Computed Tomography , Postmenopause , Premenopause , Risk Factors
5.
AJR Am J Roentgenol ; 210(4): 807-815, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29412019

ABSTRACT

OBJECTIVE: The purpose of this project was to achieve sustained improvement in mammographic breast positioning in our department. MATERIALS AND METHODS: Between June 2013 and December 2016, we conducted a team-based performance improvement initiative with the goal of improving mammographic positioning. The team of technologists and radiologists established quantitative measures of positioning performance based on American College of Radiology (ACR) criteria, audited at least 35 mammograms per week for positioning quality, displayed performance in dashboards, provided technologists with positioning training, developed a supportive environment fostering technologist and radiologist communication surrounding mammographic positioning, and employed a mammography positioning coach to develop, improve, and maintain technologist positioning performance. Statistical significance in changes in the percentage of mammograms passing the ACR criteria were evaluated using a two-proportion z test. RESULTS: A baseline mammogram audit performed in June 2013 showed that 67% (82/122) met ACR passing criteria for positioning. Performance improved to 80% (588/739; p < 0.01) after positioning training and technologist and radiologist agreement on positioning criteria. With individual technologist feedback, positioning further improved, with 91% of mammograms passing ACR criteria (p < 0.01). Seven months later, performance temporarily decreased to 80% but improved to 89% with implementation of a positioning coach. The overall mean performance of 91% has been sustained for 23 months. The program cost approximately $30,000 to develop, $42,000 to launch, and $25,000 per year to maintain. Almost all costs were related to personnel time. CONCLUSION: Dedicated performance improvement methods may achieve significant and sustained improvement in mammographic breast positioning, which may better enable facilities to pass the recently instated Enhancing Quality Using the Inspection Program portion of a practice's annual Mammography Quality Standards Act inspections.


Subject(s)
Breast Neoplasms/diagnostic imaging , Mammography/standards , Mass Screening/standards , Patient Positioning , Quality Improvement , Radiology/education , Academic Medical Centers , Female , Humans , Inservice Training
6.
Radiology ; 285(2): 401-413, 2017 11.
Article in English | MEDLINE | ID: mdl-28708462

ABSTRACT

Purpose To identify the molecular basis of quantitative imaging characteristics of tumor-adjacent parenchyma at dynamic contrast material-enhanced magnetic resonance (MR) imaging and to evaluate their prognostic value in breast cancer. Materials and Methods In this institutional review board-approved, HIPAA-compliant study, 10 quantitative imaging features depicting tumor-adjacent parenchymal enhancement patterns were extracted and screened for prognostic features in a discovery cohort of 60 patients. By using data from The Cancer Genome Atlas (TCGA), a radiogenomic map for the tumor-adjacent parenchymal tissue was created and molecular pathways associated with prognostic parenchymal imaging features were identified. Furthermore, a multigene signature of the parenchymal imaging feature was built in a training cohort (n = 126), and its prognostic relevance was evaluated in two independent cohorts (n = 879 and 159). Results One image feature measuring heterogeneity (ie, information measure of correlation) was significantly associated with prognosis (false-discovery rate < 0.1), and at a cutoff of 0.57 stratified patients into two groups with different recurrence-free survival rates (log-rank P = .024). The tumor necrosis factor signaling pathway was identified as the top enriched pathway (hypergeometric P < .0001) among genes associated with the image feature. A 73-gene signature based on the tumor profiles in TCGA achieved good association with the tumor-adjacent parenchymal image feature (R2 = 0.873), which stratified patients into groups regarding recurrence-free survival (log-rank P = .029) and overall survival (log-rank P = .042) in an independent TCGA cohort. The prognostic value was confirmed in another independent cohort (Gene Expression Omnibus GSE 1456), with log-rank P = .00058 for recurrence-free survival and log-rank P = .0026 for overall survival. Conclusion Heterogeneous enhancement patterns of tumor-adjacent parenchyma at MR imaging are associated with the tumor necrosis signaling pathway and poor survival in breast cancer. © RSNA, 2017 Online supplemental material is available for this article.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/mortality , Image Interpretation, Computer-Assisted , Magnetic Resonance Imaging , Parenchymal Tissue/diagnostic imaging , Adult , Aged , Biomarkers, Tumor/analysis , Biomarkers, Tumor/genetics , Biomarkers, Tumor/metabolism , Breast Neoplasms/chemistry , Breast Neoplasms/genetics , Female , Gene Expression Profiling , Genomics , Humans , Kaplan-Meier Estimate , Middle Aged , Molecular Imaging , Parenchymal Tissue/chemistry , Prognosis , Signal Transduction
7.
J Magn Reson Imaging ; 46(4): 1017-1027, 2017 10.
Article in English | MEDLINE | ID: mdl-28177554

ABSTRACT

PURPOSE: To determine whether dynamic contrast enhancement magnetic resonance imaging (DCE-MRI) characteristics of the breast tumor and background parenchyma can distinguish molecular subtypes (ie, luminal A/B or basal) of breast cancer. MATERIALS AND METHODS: In all, 84 patients from one institution and 126 patients from The Cancer Genome Atlas (TCGA) were used for discovery and external validation, respectively. Thirty-five quantitative image features were extracted from DCE-MRI (1.5 or 3T) including morphology, texture, and volumetric features, which capture both tumor and background parenchymal enhancement (BPE) characteristics. Multiple testing was corrected using the Benjamini-Hochberg method to control the false-discovery rate (FDR). Sparse logistic regression models were built using the discovery cohort to distinguish each of the three studied molecular subtypes versus the rest, and the models were evaluated in the validation cohort. RESULTS: On univariate analysis in discovery and validation cohorts, two features characterizing tumor and two characterizing BPE were statistically significant in separating luminal A versus nonluminal A cancers; two features characterizing tumor were statistically significant for separating luminal B; one feature characterizing tumor and one characterizing BPE reached statistical significance for distinguishing basal (Wilcoxon P < 0.05, FDR < 0.25). In discovery and validation cohorts, multivariate logistic regression models achieved an area under the receiver operator characteristic curve (AUC) of 0.71 and 0.73 for luminal A cancer, 0.67 and 0.69 for luminal B cancer, and 0.66 and 0.79 for basal cancer, respectively. CONCLUSION: DCE-MRI characteristics of breast cancer and BPE may potentially be used to distinguish among molecular subtypes of breast cancer. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2017;46:1017-1027.


Subject(s)
Breast Neoplasms/diagnostic imaging , Contrast Media , Image Enhancement/methods , Magnetic Resonance Imaging/methods , Adult , Aged , Aged, 80 and over , Breast/diagnostic imaging , Diagnosis, Differential , Female , Humans , Middle Aged , Phenotype , Reproducibility of Results
8.
Breast J ; 22(4): 390-6, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27061012

ABSTRACT

Resection of biopsy-proven involved axillary lymph nodes (iALNs) is important to reduce the false-negative rates of sentinel lymph node (SLN) biopsy after neo-adjuvant chemotherapy (NAC) in patients with initially node-positive breast cancer. Preoperative wire localization for iALNs marked with clips placed during biopsy is a technique that may help the removal of iALNs after NAC. However, ultrasound (US)-guided localization is often difficult because the clips cannot always be reliably visible on US. Computed tomography (CT)-guided wire localization can be used; however, to date there have been no reports on CT-guided wire localization for iALNs. The aim of this study was to describe a series of patients who received CT-guided wire localization for iALN removal after NAC and to evaluate the feasibility of this technique. We retrospectively analyzed five women with initially node-positive breast cancer (age, 41-52 years) who were scheduled for SLN biopsy after NAC and received preoperative CT-guided wire localization for iALNs. CT visualized all the clips that were not identified on post-NAC US. The wire tip was deployed beyond or at the target, with the shortest distance between the wire and the index clip ranging from 0 to 2.5 mm. The total procedure time was 21-38 minutes with good patient tolerance and no complications. In four of five cases, CT wire localization aided in identification and resection of iALNs that were not identified with lymphatic mapping. Residual nodal disease was confirmed in two cases: both had residual disease in wire-localized lymph nodes in addition to SLNs. Although further studies with more cases are required, our results suggest that CT-guided wire localization for iALNs is a feasible technique that facilitates identification and removal of the iALNs as part of SLN biopsy after NAC in situations where US localization is unsuccessful.


Subject(s)
Breast Neoplasms/drug therapy , Breast Neoplasms/pathology , Lymph Nodes/diagnostic imaging , Sentinel Lymph Node Biopsy/methods , Tomography, X-Ray Computed/methods , Adult , Axilla/diagnostic imaging , Axilla/pathology , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Female , Humans , Lymph Nodes/pathology , Middle Aged , Neoadjuvant Therapy/methods , Preoperative Care/instrumentation , Preoperative Care/methods , Retrospective Studies , Sentinel Lymph Node Biopsy/instrumentation
9.
Breast J ; 22(5): 493-500, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27296462

ABSTRACT

Breast density notification laws, passed in 19 states as of October 2014, mandate that patients be informed of their breast density. The purpose of this study is to assess the impact of this legislation on radiology practices, including performance of breast cancer risk assessment and supplemental screening studies. A 20-question anonymous web-based survey was emailed to radiologists in the Society of Breast Imaging between August 2013 and March 2014. Statistical analysis was performed using Fisher's exact test. Around 121 radiologists from 110 facilities in 34 USA states and 1 Canadian site responded. About 50% (55/110) of facilities had breast density legislation, 36% of facilities (39/109) performed breast cancer risk assessment (one facility did not respond). Risk assessment was performed as a new task in response to density legislation in 40% (6/15) of facilities in states with notification laws. However, there was no significant difference in performing risk assessment between facilities in states with a law and those without (p < 0.831). In anticipation of breast density legislation, 33% (16/48), 6% (3/48), and 6% (3/48) of facilities in states with laws implemented handheld whole breast ultrasound (WBUS), automated WBUS, and tomosynthesis, respectively. The ratio of facilities offering handheld WBUS was significantly higher in states with a law than in states without (p < 0.001). In response to breast density legislation, more than 33% of facilities are offering supplemental screening with WBUS and tomosynthesis, and many are performing formal risk assessment for determining patient management.


Subject(s)
Breast Density , Breast Neoplasms/diagnostic imaging , Radiology/legislation & jurisprudence , Canada , Female , Humans , Magnetic Resonance Imaging/statistics & numerical data , Mammography/statistics & numerical data , Radiology/methods , Risk Assessment , Surveys and Questionnaires , Ultrasonography, Mammary/statistics & numerical data , United States
10.
J Magn Reson Imaging ; 41(3): 616-23, 2015 Mar.
Article in English | MEDLINE | ID: mdl-24585455

ABSTRACT

PURPOSE: To investigate the diagnostic accuracy and clinical usefulness of the rim sign in breast lesions observed in diffusion-weighted magnetic resonance imaging (DWI). MATERIALS AND METHODS: The magnetic resonance imaging (MRI) findings of 98 pathologically confirmed lesions (62 malignant and 36 benign) in 84 patients were included. Five breast radiologists were asked to independently review the breast MRI results, to grade the degree of high peripheral signal, the "rim sign," in the DWI, and to confirm the mean apparent diffusion coefficient (ADCmean ) values. We analyzed the diagnostic accuracy and compared the consensus (when ≥ 4 of 5 independent reviewers agreed) results of the rim sign with the ADCmean values. Additionally, we evaluated the correlation between the dynamic contrast-enhanced (DCE)-MRI morphologic appearance and DWI rim sign. RESULTS: According to the consensus results, the rim sign in DWI was observed on 59.7% of malignant lesions and 19.4% of benign lesions. The sensitivity, specificity, and area under the curve (AUC) value for the rim sign in DWI were 59.7%, 80.6%, and 0.701, respectively. The sensitivity, specificity, and AUC value for the ADCmean value (criteria ≤ 1.46 × 10(-3) mm(2) /sec) were 82.3%, 63.9%, and 0.731, respectively. Based on consensus, no correlation was observed between the DCE-MRI and DWI rim signs. CONCLUSION: In DWI, a high-signal rim is a valuable morphological feature for improving specificity in DWI.


Subject(s)
Breast Neoplasms/diagnosis , Diffusion Magnetic Resonance Imaging , Image Interpretation, Computer-Assisted/methods , Adult , Aged , Breast/pathology , Contrast Media , Female , Gadolinium , Humans , Image Enhancement , Middle Aged , Observer Variation , Reproducibility of Results , Sensitivity and Specificity , Young Adult
11.
J Magn Reson Imaging ; 42(6): 1656-65, 2015 Dec.
Article in English | MEDLINE | ID: mdl-25914178

ABSTRACT

PURPOSE: To compare the diagnostic value of conventional, bilateral diffusion-weighted imaging (DWI) and high-resolution targeted DWI of known breast lesions. MATERIALS AND METHODS: Twenty-one consecutive patients with known breast cancer or suspicious breast lesions were scanned with the conventional bilateral DWI technique, a high-resolution, reduced field of view (rFOV) DWI technique, and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) (3.0 T). We compared bilateral DWI and rFOV DWI quantitatively by measuring the lesions' apparent diffusion coefficient (ADC) values. For qualitative comparison, three dedicated breast radiologists scored image quality and performed lesion interpretation. RESULTS: In a phantom, ADC values were in good agreement with the reference values. Twenty-one patients (30 lesions: 14 invasive carcinomas, 10 benign lesions [of which 5 cysts], 3 high-risk, and 3 in situ carcinomas) were included. Cysts and high-risk lesions were excluded from the quantitative analysis. Quantitatively, both bilateral and rFOV DWI measured lower ADC values in invasive tumors than other lesions. In vivo, rFOV DWI gave lower ADC values than bilateral DWI (1.11 × 10(-3) mm(2) /s vs. 1.24 × 10(-3) mm(2) /s, P = 0.002). Regions of interest (ROIs) were comparable in size between the two techniques (2.90 vs. 2.13 cm(2) , P = 0.721). Qualitatively, all three radiologists scored sharpness of rFOV DWI images as significantly higher than bilateral DWI (P ≤ 0.002). Receiver operating characteristic (ROC) curve analysis showed a higher area under the curve (AUC) in BI-RADS classification for rFOV DWI compared to bilateral DWI (0.71 to 0.93 vs. 0.61 to 0.76, respectively). CONCLUSION: Tumor morphology can be assessed in more detail with high-resolution DWI (rFOV) than with standard bilateral DWI by providing significantly sharper images.


Subject(s)
Algorithms , Breast Neoplasms/pathology , Breast/pathology , Diffusion Magnetic Resonance Imaging/methods , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Adult , Aged , Cell Size , Diffusion Magnetic Resonance Imaging/instrumentation , Female , Humans , Middle Aged , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity
12.
Breast J ; 26(9): 1838-1840, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32304610
13.
J Magn Reson Imaging ; 39(2): 332-8, 2014 Feb.
Article in English | MEDLINE | ID: mdl-23596017

ABSTRACT

PURPOSE: To evaluate the performance of 2D versus 3D T2-weighted spin echo imaging in the breast. MATERIALS AND METHODS: 2D and 3D T2-weighted images were acquired in 25 patients as part of a clinically indicated breast magnetic resonance imaging (MRI) exam. Lesion-to-fibroglandular tissue signal ratio was measured in 16 identified lesions. Clarity of lesion morphology was assessed through a blinded review by three radiologists. Instances demonstrating the potential diagnostic contribution of 3D versus 2D T2-weighted imaging in the breast were noted through unblinded review by a fourth radiologist. RESULTS: The lesion-to-fibroglandular tissue signal ratio was well correlated between 2D and 3D T2-weighted images (R(2) = 0.93). Clarity of lesion morphology was significantly better with 3D T2-weighted imaging for all observers based on a McNemar test (P ≤ 0.02, P ≤ 0.01, P ≤ 0.03). Instances indicating the potential diagnostic contribution of 3D T2-weighted imaging included improved depiction of signal intensity and improved alignment between DCE and T2-weighted findings. CONCLUSION: In this pilot study, 3D T2-weighted imaging provided comparable contrast and improved depiction of lesion morphology in the breast in comparison to 2D T2-weighted imaging. Based on these results further investigation to determine the diagnostic impact of 3D T2-weighted imaging in breast MRI is warranted.


Subject(s)
Algorithms , Breast Neoplasms/pathology , Diffusion Magnetic Resonance Imaging/methods , Echo-Planar Imaging/methods , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Female , Humans , Image Enhancement/methods , Observer Variation , Pilot Projects , Reproducibility of Results , Sensitivity and Specificity , Spin Labels
15.
J Breast Imaging ; 6(2): 203-216, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38262628

ABSTRACT

Breast surgery is the cornerstone of treatment for early breast cancer. Historically, mastectomy and conventional breast-conserving surgery (BCS) were the main surgical techniques for treatment. Now, oncoplastic breast surgery (OBS), introduced in the 1990s, allows for a combination of BCS and reconstructive surgery to excise the cancer while preserving or enhancing the contour of the breast, leading to improved aesthetic results. Although imaging after conventional lumpectomy demonstrates typical postsurgical changes with known evolution patterns over time, OBS procedures show postsurgical changes/fat necrosis in locations other than the lumpectomy site. The purpose of this article is to familiarize radiologists with various types of surgical techniques for removal of breast cancer and to distinguish benign postoperative imaging findings from suspicious findings that warrant further work-up.


Subject(s)
Breast Neoplasms , Mammaplasty , Humans , Female , Mastectomy , Mastectomy, Segmental/adverse effects , Breast Neoplasms/diagnostic imaging , Breast/diagnostic imaging , Mammaplasty/adverse effects
16.
Radiology ; 269(3): 887-92, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24023072

ABSTRACT

In anticipation of breast density notification legislation in the state of California, which would require notification of women with heterogeneously and extremely dense breast tissue, a working group of breast imagers and breast cancer risk specialists was formed to provide a common response framework. The California Breast Density Information Group identified key elements and implications of the law, researching scientific evidence needed to develop a robust response. In particular, issues of risk associated with dense breast tissue, masking of cancers by dense tissue on mammograms, and the efficacy, benefits, and harms of supplementary screening tests were studied and consensus reached. National guidelines and peer-reviewed published literature were used to recommend that women with dense breast tissue at screening mammography follow supplemental screening guidelines based on breast cancer risk assessment. The goal of developing educational materials for referring clinicians and patients was reached with the construction of an easily accessible Web site that contains information about breast density, breast cancer risk assessment, and supplementary imaging. This multi-institutional, multidisciplinary approach may be useful for organizations to frame responses as similar legislation is passed across the United States. Online supplemental material is available for this article.


Subject(s)
Breast Neoplasms/pathology , Breast/pathology , Disease Notification/legislation & jurisprudence , Breast Neoplasms/diagnostic imaging , California , Female , Humans , Mammography , Mass Screening , Pregnancy , Risk
17.
J Breast Imaging ; 5(6): 675-684, 2023 Nov 30.
Article in English | MEDLINE | ID: mdl-38141238

ABSTRACT

OBJECTIVE: To evaluate the ability of a long-term technologist coaching program to sustain gains in mammography quality made by a previously implemented quality improvement (QI) initiative. METHODS: Mammography quality metrics from July 2014 to June 2020 were reviewed. Numbers of screening mammograms performed/audited, monthly average mammogram overall quality pass rates, changes in facilities/staffing, and technical recall rates were evaluated. Performance metrics at baseline (July 2013), during the improvement (July 2014 to January 2015), postimprovement (February 2015 to August 2015), and sustained coaching periods (after initiation of the technologist coaching model, from September 2015 to June 2020) were compared. RESULTS: During the postimprovement and sustained coaching periods, 93% (501/541) and 90% (8902/9929) of audited mammograms, respectively, met overall passing criteria, achieving or exceeding the QI goal of 90%, and results for both periods were significantly higher than that during the improvement period (74%, 1098/1489), at P < 0.0001 and P < 0.0001, respectively. The technical recall rates during the improvement and postimprovement periods were 2.6% (85/3321) and 1.7% (54/3236), respectively; the rate during the sustained coaching period was significantly lower than these, at 1.2% (489/40 440) (P < 0.0001 and P = 0.0232, respectively). Sustained quality passing rates and lower technical recall rates were observed despite statistically significantly increases in screening volumes. CONCLUSION: A technologist coaching program resulted in sustained high mammographic quality for almost 5 years.


Subject(s)
Mentoring , Mammography , Quality Improvement , Benchmarking , Early Detection of Cancer
18.
J Breast Imaging ; 4(4): 371-377, 2022 Jul 29.
Article in English | MEDLINE | ID: mdl-38416983

ABSTRACT

OBJECTIVE: To evaluate breast density notification legislation (BDNL) on breast imaging practice patterns, risk assessment, and supplemental screening. METHODS: A 20-question anonymous web-based survey was administered to practicing Society of Breast Imaging radiologists in the U.S. between February and April 2021 regarding breast cancer risk assessment, supplemental screening, and density measurements. Results were compared between facilities with and without BDNL using the two-sided Fisher's exact test. RESULTS: One hundred and ninety-seven radiologists from 41 U.S. states, with (187/197, 95%) or without (10/197, 5%) BDNL, responded. Fifty-seven percent (113/197) performed breast cancer risk assessment, and 93% (183/197) offered supplemental screening for women with dense breasts. Between facilities with or without BDNL, there was no significant difference in whether risk assessment was (P = 0.19) or was not performed (P = 0.20). There was no significant difference in supplemental screening types (P > 0.05) between BDNL and non-BDNL facilities. Thirty-five percent (69/197) of facilities offered no supplemental screening studies, and 25% (49/197) had no future plans to offer supplemental screening. A statistically significant greater proportion of non-BDNL facilities offered no supplemental screening (P < 0.03) and had no plans to offer supplemental screening compared to BDNL facilities (P < 0.02). CONCLUSION: Facilities in BDNL states often offer supplemental screening compared to facilities in non-BDNL states. Compared to BDNL facilities, a statistically significant proportion of non-BDNL facilities had no supplemental screening nor plans for implementation. Our data suggest that upcoming federal BDNL will impact how supplemental screening is addressed in currently non-BDNL states.

20.
Br J Radiol ; 94(1118): 20201166, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33332980

ABSTRACT

OBJECTIVE: To compare positive predictive values (PPVs) of clumped vs non-clumped (homogenous and heterogeneous) internal enhancement on MRI detected linear non-mass enhancement (NME) on MRI-guided vacuum-assisted breast biopsy (MRI-VABB). METHODS: With IRB (Institutional Review Board) approval, we retrospectively reviewed 598 lesions undergoing MRI-VABB from January 2015 to April 2018 that showed linear NME. We reviewed the electronic medical records for MRI-VABB pathology, any subsequent surgery and clinical follow-up. The X2 test was performed for univariate analysis. RESULTS: There were 120/598 (20%) linear NME MRI-VABB lesions with clumped (52/120, 43%) vs non-clumped (68/120, 57%) internal enhancement, average size 1.8 cm (range 0.6-7.6 cm). On MRI-VABB, cancer was identified in 22/120 (18%) lesions, ductal carcinoma in situ (DCIS) was found in 18/22 (82%) and invasive cancer in 4 (18%). 3/31 (10%) high-risk lesions upgraded to DCIS at surgery, for a total of 25/120 (21%) malignancies. Malignancy was found in 12/52 (23%) clumped lesions and in 13/68 (19%) of non-clumped lesions that showed heterogeneous (5/13, 38%) or homogenous (8/13, 62%) internal enhancement. The PPV of linear NME with clumped internal enhancement (23.1%) was not significantly different from the PPV of non-clumped linear NME (19.1%) (p = 0.597). The PPV of linear NME lesions <1 cm (33.3%) was not significantly different from the PPV of lesions ≥1 cm (18.6%) (p = 0.157). CONCLUSIONS: Linear NME showed malignancy in 21% of our series. Linear NME with clumped or non-clumped internal enhancement patterns, regardless of lesion size, might need to undergo MRI-VABB in appropriate populations. ADVANCES IN KNOWLEDGE: Evaluation of linear NME lesions on breast MRI focuses especially on internal enhancement pattern.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Magnetic Resonance Imaging/methods , Adult , Aged , Aged, 80 and over , Breast/diagnostic imaging , Breast/pathology , Female , Humans , Image-Guided Biopsy , Middle Aged , Retrospective Studies , Vacuum
SELECTION OF CITATIONS
SEARCH DETAIL