Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Endoscopy ; 2024 May 23.
Article in English | MEDLINE | ID: mdl-38782021

ABSTRACT

OBJECTIVE: Endoscopic ultrasound(EUS) guided drainage of walled off necrosis(WON) with either plastic stents or metal stents is the mainstay of WON management. This is a single center randomized controlled study evaluating the efficacy of bi-flanged metal stent(BFMS) and plastic stents for WON drainage. DESIGN: Patients with symptomatic WON amenable for EUS guided drainage were randomized to either BFMS or plastic stents. Primary outcome was reintervention free clinical success at 4 weeks. Secondary outcomes were overall clinical success(complete resolution of symptoms and significant reduction in size of WON (<50% of original size and <5 cm largest diameter size at 4-week follow-up)), number of re-interventions, adverse events, hospital stay for first admission and medium term outcomes at 6 months (recurrence, disconnected pancreatic duct, chronic pancreatitis and new onset diabetes mellitus). RESULTS: 92 patients were randomized - 46 in each arm. The reintervention free clinical success was significantly higher in BFMS group(67.4% vs 43.5%; P: 0.021; ITT analysis). Overall clinical success at one month was similar in both groups. There were significantly lower number of reinterventions (median 0(IQR 0-1) vs 1(0-2) P:0.028)and hospital stay duration in BFMS group(7.04 ± 3.36 days vs 9.09 ± 5.53 days; P:0.035). There was no difference in procedure-related adverse events, mortality and medium-term outcomes. CONCLUSIONS: The BFMS provides higher reintervention free clinical success at 4 weeks with shorter hospital stay without increased risk of adverse events compared to plastic stents for EUS-guided drainage of WON. Medium term outcomes are however similar in both BFMS, and plastics stents.

2.
Endoscopy ; 54(9): 861-868, 2022 09.
Article in English | MEDLINE | ID: mdl-35180798

ABSTRACT

BACKGROUND: Disconnected pancreatic duct (DPD) after development of walled-off necrosis (WON) predisposes to recurrent (peri)pancreatic fluid collection (PFC). In this randomized controlled trial, we compared plastic stents with no plastic stent after removal of a large-caliber metal stent (LCMS) on incidence of recurrent PFCs in DPD. METHODS : Consecutive patients with WON who underwent endoscopic ultrasound (EUS)-guided drainage with LCMS between September 2017 and March 2020 were screened for eligibility. At LCMS removal (4 weeks after drainage), patients with DPD were randomized to plastic stent or no stent groups. The primary outcome was incidence of recurrent PFC at 3 months. Secondary outcomes were technical success of plastic stent deployment, adverse events, stent migration, and recurrence of PFC at 6 and 12 months. RESULTS: 236 patients with WON underwent EUS-guided drainage using LCMS, and 104 (males 94, median age 34 years (interquartile range [IQR] 26-44.7) with DPD were randomized into stenting (n = 52) and no-stenting (n = 52) groups. Plastic stent deployment was successful in 88.5 %. Migration occurred in 19.2 % at median follow-up of 8 months (IQR 2.5-12). Recurrent PFCs occurred in six patients at 3 months (stent n = 3, no stent n = 3). There was no significant difference in PFC recurrence between the two groups at 3, 6, and 12 months. Reintervention was required in seven patients with recurrent PFCs, with no significant difference between the two groups. CONCLUSION: In patients with WON and DPD, deployment of plastic stents after LCMS removal did not reduce recurrence of PFC.


Subject(s)
Pancreatic Diseases , Adult , Drainage/methods , Endosonography/methods , Humans , Male , Metals , Necrosis/etiology , Pancreatic Diseases/complications , Pancreatic Ducts/surgery , Retrospective Studies , Stents/adverse effects , Treatment Outcome
3.
Endosc Int Open ; 11(2): E172-E178, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36845273

ABSTRACT

Background and study aims Percutaneous liver biopsy is traditionally done on the right lobe of the liver. Endoscopic ultrasound-guided liver biopsy (EUS-LB) can be performed on either the left or right lobe or as a combined bi-lobar biopsy. Earlier studies did not compare the benefit of bi-lobar biopsies to single-lobe biopsy for reaching a tissue diagnosis. The current study compared the degree of agreement of pathological diagnosis between the left lobe of the liver compared to right-lobe and with bi-lobar biopsy. Patients and methods Fifty patients fulfilling the inclusion criteria were enrolled in the study. EUS-LB with a 22G core needle was performed separately on both the liver lobes. Three pathologists, who were blinded to the site of biopsy independently reviewed the liver biopsies. Sample adequacy, safety, and concordance of pathological diagnosis between left- and right-lobe biopsy of the liver were analyzed. Results The pathological diagnosis was made in 96 % of patients. Specimen lengths from the left lobe and the right lobe were 2.31 ±â€Š0.57 cm and 2.28 ±â€Š0.69 cm, respectively ( P  = 0.476). The respective number of portal tracts were 11.84 ±â€Š6.71 versus 9.58 ±â€Š7.14; P  = 0.106. Diagnosis between the two lobes showed substantial (κ = 0.830) concordance. Left-lobe (κ value 0.878) and right-lobe (κ = 0.903) biopsies showed no difference when compared with bi-lobar biopsies. Adverse events were observed in two patients, both of whom had biopsies of the right lobe. Conclusions EUS-guided left-lobe liver biopsy is safer than right-lobe biopsy with similar diagnostic yield.

SELECTION OF CITATIONS
SEARCH DETAIL