Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Malar J ; 20(1): 110, 2021 Feb 25.
Article in English | MEDLINE | ID: mdl-33632222

ABSTRACT

BACKGROUND: Manual microscopy remains a widely-used tool for malaria diagnosis and clinical studies, but it has inconsistent quality in the field due to variability in training and field practices. Automated diagnostic systems based on machine learning hold promise to improve quality and reproducibility of field microscopy. The World Health Organization (WHO) has designed a 55-slide set (WHO 55) for their External Competence Assessment of Malaria Microscopists (ECAMM) programme, which can also serve as a valuable benchmark for automated systems. The performance of a fully-automated malaria diagnostic system, EasyScan GO, on a WHO 55 slide set was evaluated. METHODS: The WHO 55 slide set is designed to evaluate microscopist competence in three areas of malaria diagnosis using Giemsa-stained blood films, focused on crucial field needs: malaria parasite detection, malaria parasite species identification (ID), and malaria parasite quantitation. The EasyScan GO is a fully-automated system that combines scanning of Giemsa-stained blood films with assessment algorithms to deliver malaria diagnoses. This system was tested on a WHO 55 slide set. RESULTS: The EasyScan GO achieved 94.3 % detection accuracy, 82.9 % species ID accuracy, and 50 % quantitation accuracy, corresponding to WHO microscopy competence Levels 1, 2, and 1, respectively. This is, to our knowledge, the best performance of a fully-automated system on a WHO 55 set. CONCLUSIONS: EasyScan GO's expert ratings in detection and quantitation on the WHO 55 slide set point towards its potential value in drug efficacy use-cases, as well as in some case management situations with less stringent species ID needs. Improved runtime may enable use in general case management settings.


Subject(s)
Diagnostic Tests, Routine/methods , Malaria, Falciparum/diagnosis , Microscopy/instrumentation , Plasmodium falciparum/isolation & purification , Automation, Laboratory , Diagnostic Tests, Routine/instrumentation , Humans , Malaria/diagnosis , Plasmodium/isolation & purification , Reproducibility of Results , World Health Organization
2.
Malar J ; 17(1): 339, 2018 Sep 25.
Article in English | MEDLINE | ID: mdl-30253764

ABSTRACT

BACKGROUND: Microscopic examination of Giemsa-stained blood films remains a major form of diagnosis in malaria case management, and is a reference standard for research. However, as with other visualization-based diagnoses, accuracy depends on individual technician performance, making standardization difficult and reliability poor. Automated image recognition based on machine-learning, utilizing convolutional neural networks, offers potential to overcome these drawbacks. A prototype digital microscope device employing an algorithm based on machine-learning, the Autoscope, was assessed for its potential in malaria microscopy. Autoscope was tested in the Iquitos region of Peru in 2016 at two peripheral health facilities, with routine microscopy and PCR as reference standards. The main outcome measures include sensitivity and specificity of diagnosis of malaria from Giemsa-stained blood films, using PCR as reference. METHODS: A cross-sectional, observational trial was conducted at two peripheral primary health facilities in Peru. 700 participants were enrolled with the criteria: (1) age between 5 and 75 years, (2) history of fever in the last 3 days or elevated temperature on admission, (3) informed consent. The main outcome measures included sensitivity and specificity of diagnosis of malaria from Giemsa-stained blood films, using PCR as reference. RESULTS: At the San Juan clinic, sensitivity of Autoscope for diagnosing malaria was 72% (95% CI 64-80%), and specificity was 85% (95% CI 79-90%). Microscopy performance was similar to Autoscope, with sensitivity 68% (95% CI 59-76%) and specificity 100% (95% CI 98-100%). At San Juan, 85% of prepared slides had a minimum of 600 WBCs imaged, thus meeting Autoscope's design assumptions. At the second clinic, Santa Clara, the sensitivity of Autoscope was 52% (95% CI 44-60%) and specificity was 70% (95% CI 64-76%). Microscopy performance at Santa Clara was 42% (95% CI 34-51) and specificity was 97% (95% CI 94-99). Only 39% of slides from Santa Clara met Autoscope's design assumptions regarding WBCs imaged. CONCLUSIONS: Autoscope's diagnostic performance was on par with routine microscopy when slides had adequate blood volume to meet its design assumptions, as represented by results from the San Juan clinic. Autoscope's diagnostic performance was poorer than routine microscopy on slides from the Santa Clara clinic, which generated slides with lower blood volumes. Results of the study reflect both the potential for artificial intelligence to perform tasks currently conducted by highly-trained experts, and the challenges of replicating the adaptiveness of human thought processes.


Subject(s)
Diagnostic Tests, Routine/methods , Malaria, Falciparum/diagnosis , Malaria, Vivax/diagnosis , Microscopy/methods , Adolescent , Adult , Aged , Child , Child, Preschool , Cross-Sectional Studies , Diagnostic Tests, Routine/instrumentation , Humans , Microscopy/instrumentation , Middle Aged , Peru , Plasmodium falciparum/isolation & purification , Plasmodium vivax/isolation & purification , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity , Young Adult
3.
J Natl Cancer Inst ; 111(9): 923-932, 2019 09 01.
Article in English | MEDLINE | ID: mdl-30629194

ABSTRACT

BACKGROUND: Human papillomavirus vaccination and cervical screening are lacking in most lower resource settings, where approximately 80% of more than 500 000 cancer cases occur annually. Visual inspection of the cervix following acetic acid application is practical but not reproducible or accurate. The objective of this study was to develop a "deep learning"-based visual evaluation algorithm that automatically recognizes cervical precancer/cancer. METHODS: A population-based longitudinal cohort of 9406 women ages 18-94 years in Guanacaste, Costa Rica was followed for 7 years (1993-2000), incorporating multiple cervical screening methods and histopathologic confirmation of precancers. Tumor registry linkage identified cancers up to 18 years. Archived, digitized cervical images from screening, taken with a fixed-focus camera ("cervicography"), were used for training/validation of the deep learning-based algorithm. The resultant image prediction score (0-1) could be categorized to balance sensitivity and specificity for detection of precancer/cancer. All statistical tests were two-sided. RESULTS: Automated visual evaluation of enrollment cervigrams identified cumulative precancer/cancer cases with greater accuracy (area under the curve [AUC] = 0.91, 95% confidence interval [CI] = 0.89 to 0.93) than original cervigram interpretation (AUC = 0.69, 95% CI = 0.63 to 0.74; P < .001) or conventional cytology (AUC = 0.71, 95% CI = 0.65 to 0.77; P < .001). A single visual screening round restricted to women at the prime screening ages of 25-49 years could identify 127 (55.7%) of 228 precancers (cervical intraepithelial neoplasia 2/cervical intraepithelial neoplasia 3/adenocarcinoma in situ [AIS]) diagnosed cumulatively in the entire adult population (ages 18-94 years) while referring 11.0% for management. CONCLUSIONS: The results support consideration of automated visual evaluation of cervical images from contemporary digital cameras. If achieved, this might permit dissemination of effective point-of-care cervical screening.


Subject(s)
Cervix Uteri/diagnostic imaging , Deep Learning , Image Processing, Computer-Assisted , Uterine Cervical Neoplasms/diagnostic imaging , Uterine Cervical Neoplasms/epidemiology , Adult , Aged , Aged, 80 and over , Algorithms , Area Under Curve , Case-Control Studies , Cervix Uteri/pathology , Colposcopy , Early Detection of Cancer , Female , Humans , Image Processing, Computer-Assisted/methods , Mass Screening , Middle Aged , Population Surveillance , Sensitivity and Specificity , Severity of Illness Index , Uterine Cervical Neoplasms/pathology , Young Adult , Uterine Cervical Dysplasia/diagnostic imaging , Uterine Cervical Dysplasia/epidemiology , Uterine Cervical Dysplasia/pathology
SELECTION OF CITATIONS
SEARCH DETAIL