1.
J Cardiovasc Electrophysiol ; 35(1): 44-57, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37927196

ABSTRACT

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly used during left atrial appendage occlusion (LAAO) as an alternative to transesophageal echocardiography (TEE). The objective of this study is to evaluate the impact of ICE versus TEE guidance during LAAO on procedural characteristics and acute outcomes, as well the presence of peri-device leaks and residual septal defects during follow-up. METHODS: All studies comparing ICE-guided versus TEE-guided LAAO were identified. The primary outcomes were procedural efficacy and occurrence of procedure-related complications. Secondary outcomes included lab efficiency (defined as a reduction in in-room time), procedural time, fluoroscopy time, and presence of peri-device leaks and residual interatrial septal defects (IASD) during follow-up. RESULTS: Twelve studies (n = 5637) were included. There were no differences in procedural success (98.3% vs. 97.8%; OR 0.73, 95% CI 0.42-1.27, p = .27; I2 = 0%) or adverse events (4.5% vs. 4.4%; OR 0.81 95% CI 0.56-1.16, p = .25; I2 = 0%) between the ICE-guided and TEE-guided groups. ICE guidance reduced in in-room time (mean-weighted 28.6-min reduction in in-room time) without differences in procedural time or fluoroscopy time. There were no differences in peri-device leak (OR 0.93, 95% CI 0.68-1.27, p = 0.64); however, an increased prevalence of residual IASD was observed with ICE-guided versus TEE-guided LAAO (46.3% vs. 34.2%; OR 2.23, 95% CI 1.05-4.75, p = 0.04). CONCLUSION: ICE guidance is associated with similar procedural efficacy and safety, but could result in improved lab efficiency (as established by a significant reduction in in-room time). No differences in the rate of periprocedural leaks were found. A higher prevalence of residual interatrial septal defects was observed with ICE guidance.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Echocardiography, Transesophageal , Treatment Outcome
2.
J Cardiovasc Electrophysiol ; 35(8): 1645-1655, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38924224

ABSTRACT

INTRODUCTION: Training in clinical cardiac electrophysiology (CCEP) involves the development of catheter handling skills to safely deliver effective treatment. Objective data from analysis of ablation data for evaluating trainee of CCEP procedures has not previously been possible. Using the artificial intelligence cloud-based system (CARTONET), we assessed the impact of trainee progress through ablation procedural quality. METHODS: Lesion- and procedure-level data from all de novo atrial fibrillation (AF) and cavotricuspid isthmus (CTI) ablations involving first-year (Y1) or second-year (Y2) fellows across a full year of fellowship was curated within Cartonet. Lesions were automatically assigned to anatomic locations. RESULTS: Lesion characteristics, including contact force, catheter stability, impedance drop, ablation index value, and interlesion time/distance were similar over each training year. Anatomic location and supervising operator significantly affected catheter stability. The proportion of lesion sets delivered independently and of lesions delivered by the trainee increased steadily from the first quartile of Y1 to the last quartile of Y2. Trainee perception of difficult regions did not correspond to objective measures. CONCLUSION: Objective ablation data from Cartonet showed that the progression of trainees through CCEP training does not impact lesion-level measures of treatment efficacy (i.e., catheter stability, impedance drop). Data demonstrates increasing independence over a training fellowship. Analyses like these could be useful to inform individualized training programs and to track trainee's progress. It may also be a useful quality assurance tool for ensuring ongoing consistency of treatment delivered within training institutions.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Clinical Competence , Education, Medical, Graduate , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Learning Curve , Electrophysiologic Techniques, Cardiac , Artificial Intelligence , Time Factors , Treatment Outcome , Fellowships and Scholarships , Cardiologists/education , Cardiac Electrophysiology/education , Cardiac Catheters
3.
Eur Heart J ; 42(38): 3932-3944, 2021 10 07.
Article in English | MEDLINE | ID: mdl-34491319

ABSTRACT

AIMS: Risk stratification algorithms for sudden cardiac death (SCD) in hypertrophic cardiomyopathy (HCM) and regional differences in clinical practice have evolved over time. We sought to compare primary prevention implantable cardioverter defibrillator (ICD) implantation rates and associated clinical outcomes in US vs. non-US tertiary HCM centres within the international Sarcomeric Human Cardiomyopathy Registry. METHODS AND RESULTS: We included patients with HCM enrolled from eight US sites (n = 2650) and five non-US (n = 2660) sites and used multivariable Cox-proportional hazards models to compare outcomes between sites. Primary prevention ICD implantation rates in US sites were two-fold higher than non-US sites (hazard ratio (HR) 2.27 [1.89-2.74]), including in individuals deemed at high 5-year SCD risk (≥6%) based on the HCM risk-SCD score (HR 3.27 [1.76-6.05]). US ICD recipients also had fewer traditional SCD risk factors. Among ICD recipients, rates of appropriate ICD therapy were significantly lower in US vs. non-US sites (HR 0.52 [0.28-0.97]). No significant difference was identified in the incidence of SCD/resuscitated cardiac arrest among non-recipients of ICDs in US vs. non-US sites (HR 1.21 [0.74-1.97]). CONCLUSION: Primary prevention ICDs are implanted more frequently in patients with HCM in US vs. non-US sites across the spectrum of SCD risk. There was a lower rate of appropriate ICD therapy in US sites, consistent with a lower-risk population, and no significant difference in SCD in US vs. non-US patients who did not receive an ICD. Further studies are needed to understand what drives malignant arrhythmias, optimize ICD allocation, and examine the impact of different ICD utilization strategies on long-term outcomes in HCM.


Subject(s)
Cardiomyopathy, Hypertrophic , Defibrillators, Implantable , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/therapy , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Humans , Primary Prevention , Risk Assessment , Risk Factors
4.
Circulation ; 141(4): 301-312, 2020 01 28.
Article in English | MEDLINE | ID: mdl-31735076

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is the most common clinical arrhythmia and is associated with heart failure, stroke, and increased mortality. The myocardial substrate for AF is poorly understood because of limited access to primary human tissue and mechanistic questions around existing in vitro or in vivo models. METHODS: Using an MYH6:mCherry knock-in reporter line, we developed a protocol to generate and highly purify human pluripotent stem cell-derived cardiomyocytes displaying physiological and molecular characteristics of atrial cells. We modeled human MYL4 mutants, one of the few definitive genetic causes of AF. To explore non-cell-autonomous components of AF substrate, we also created a zebrafish Myl4 knockout model, which exhibited molecular, cellular, and physiologic abnormalities that parallel those in humans bearing the cognate mutations. RESULTS: There was evidence of increased retinoic acid signaling in both human embryonic stem cells and zebrafish mutant models, as well as abnormal expression and localization of cytoskeletal proteins, and loss of intracellular nicotinamide adenine dinucleotide and nicotinamide adenine dinucleotide + hydrogen. To identify potentially druggable proximate mechanisms, we performed a chemical suppressor screen integrating multiple human cellular and zebrafish in vivo endpoints. This screen identified Cx43 (connexin 43) hemichannel blockade as a robust suppressor of the abnormal phenotypes in both models of MYL4 (myosin light chain 4)-related atrial cardiomyopathy. Immunofluorescence and coimmunoprecipitation studies revealed an interaction between MYL4 and Cx43 with altered localization of Cx43 hemichannels to the lateral membrane in MYL4 mutants, as well as in atrial biopsies from unselected forms of human AF. The membrane fraction from MYL4-/- human embryonic stem cell derived atrial cells demonstrated increased phospho-Cx43, which was further accentuated by retinoic acid treatment and by the presence of risk alleles at the Pitx2 locus. PKC (protein kinase C) was induced by retinoic acid, and PKC inhibition also rescued the abnormal phenotypes in the atrial cardiomyopathy models. CONCLUSIONS: These data establish a mechanistic link between the transcriptional, metabolic and electrical pathways previously implicated in AF substrate and suggest novel avenues for the prevention or therapy of this common arrhythmia.


Subject(s)
Atrial Fibrillation , Mutation , Myocytes, Cardiac , Myosin Light Chains , Animals , Animals, Genetically Modified/genetics , Animals, Genetically Modified/metabolism , Atrial Fibrillation/genetics , Atrial Fibrillation/metabolism , Atrial Fibrillation/pathology , Cell Line , Connexin 43/genetics , Connexin 43/metabolism , Gene Knockout Techniques , Heart Atria/metabolism , Heart Atria/pathology , Human Embryonic Stem Cells/metabolism , Human Embryonic Stem Cells/pathology , Humans , Induced Pluripotent Stem Cells/metabolism , Induced Pluripotent Stem Cells/pathology , Myocytes, Cardiac/metabolism , Myocytes, Cardiac/pathology , Myosin Light Chains/genetics , Myosin Light Chains/metabolism , Zebrafish , Zebrafish Proteins/genetics , Zebrafish Proteins/metabolism
5.
Development ; 145(3)2018 02 05.
Article in English | MEDLINE | ID: mdl-29361575

ABSTRACT

NKX2-5 is the most commonly mutated gene associated with human congenital heart defects (CHDs), with a predilection for cardiac pole abnormalities. This homeodomain transcription factor is a central regulator of cardiac development and is expressed in both the first and second heart fields (FHF and SHF). We have previously revealed essential functions of nkx2.5 and nkx2.7, two Nkx2-5 homologs expressed in zebrafish cardiomyocytes, in maintaining ventricular identity. However, the differential roles of these genes in the specific subpopulations of the anterior (aSHF) and posterior (pSHF) SHFs have yet to be fully defined. Here, we show that Nkx genes regulate aSHF and pSHF progenitors through independent mechanisms. We demonstrate that Nkx genes restrict proliferation of aSHF progenitors in the outflow tract, delimit the number of pSHF progenitors at the venous pole and pattern the sinoatrial node acting through Isl1 repression. Moreover, optical mapping highlights the requirement for Nkx gene dose in establishing electrophysiological chamber identity and in integrating the physiological connectivity of FHF and SHF cardiomyocytes. Ultimately, our results may shed light on the discrete errors responsible for NKX2-5-dependent human CHDs of the cardiac outflow and inflow tracts.


Subject(s)
Heart/embryology , Homeobox Protein Nkx-2.5/genetics , Homeodomain Proteins/genetics , LIM-Homeodomain Proteins/genetics , Myoblasts, Cardiac/cytology , Myoblasts, Cardiac/metabolism , Transcription Factors/genetics , Zebrafish Proteins/genetics , Animals , Animals, Genetically Modified , Body Patterning/genetics , Cell Differentiation , Cell Proliferation , Gene Expression Regulation, Developmental , Heart Defects, Congenital/embryology , Heart Defects, Congenital/genetics , Humans , Mutation
6.
Circulation ; 136(13): 1247-1255, 2017 Sep 26.
Article in English | MEDLINE | ID: mdl-28947480

ABSTRACT

Esophageal perforation is a dreaded complication of atrial fibrillation ablation that occurs in 0.1% to 0.25% of atrial fibrillation ablation procedures. Delayed diagnosis is associated with the development of atrial-esophageal fistula (AEF) and increased mortality. The relationship between the esophagus and the left atrial posterior wall is variable, and the esophagus is most susceptible to injury where it is closest to areas of endocardial ablation. Esophageal ulcer seems to precede AEF development, and postablation endoscopy documenting esophageal ulcer may identify patients at higher risk for AEF. AEF has been reported with all modalities of atrial fibrillation ablation despite esophageal temperature monitoring. Despite the name AEF, fistulas functionally act 1 way, esophageal to atrial, which accounts for the observed symptoms and imaging findings. Because of the rarity of AEF, evaluation and validation of strategies to reduce AEF remain challenging. A high index of suspicion is recommended in patients who develop constitutional symptoms or sudden onset chest pain that start days or weeks after atrial fibrillation ablation. Early detection by computed tomography scan with oral and intravenous contrast is safe and feasible, whereas performance of esophageal endoscopy in the presence of AEF may result in significant neurological injury resulting from air embolism. Outcomes for esophageal stenting are poor in AEF. Aggressive intervention with skilled cardiac and thoracic surgeons may improve chances of stroke-free survival for all types of esophageal perforation.


Subject(s)
Atrial Fibrillation/pathology , Catheter Ablation/adverse effects , Esophageal Fistula/etiology , Atrial Fibrillation/drug therapy , Atrial Fibrillation/surgery , Esophageal Fistula/diagnosis , Esophageal Fistula/epidemiology , Esophagus/anatomy & histology , Esophagus/injuries , Esophagus/physiopathology , Histamine H2 Antagonists/therapeutic use , Humans , Prognosis , Proton Pump Inhibitors/therapeutic use
7.
J Cardiovasc Electrophysiol ; 29(1): 79-89, 2018 01.
Article in English | MEDLINE | ID: mdl-28940781

ABSTRACT

BACKGROUND: Right ventricular (RV)-scar related ventricular tachycardia (VT) is often due to arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) or cardiac sarcoidosis (CS), but some patients whose clinical course has not been described do not fulfill diagnostic criteria for these diseases. We sought to characterize the electrophysiologic substrate and catheter ablation outcomes of such patients, termed RV cardiomyopathy of unknown source (RCUS). METHODS AND RESULTS: Data of 100 consecutive patients who presented with RV cardiomyopathy and/or RV-related VT for ablation were reviewed (51 ARVC/D, 22 CS; 27 RCUS). Compared to ARVC/D, RCUS patients were older (P = 0.001), less commonly had RV dilatation (P = 0.001) or dysfunction (P = 0.01) and fragmented QRS, parietal block, and T-wave inversion. Compared to CS, R-CUS patients had less severe LV dysfunction. Extent and distribution of endocardial/epicardial scar and inducible VTs in RCUS patients were comparable with ARVC/D and CS patients. At a median follow-up of 23 months, RCUS patients had more favorable VT-free survival (RCUS 71%, ARVC/D 60%, CS 41%, P = 0.03) and survival free of death or cardiac transplant (RCUS 92%, ARVC/D 92%, CS 62%, P = 0.01). No RCUS patients developed new criteria for ARVC/D or CS in follow-up. CONCLUSIONS: Up to one-third of patients with RV scar-related VT are not classifiable as ARVC/D or CS. These patients had a somewhat better prognosis than ARVC/D or sarcoid and did not develop evidence of these diseases during the initial 2 years of follow-up. The extent to which this population comprises mild ARVC/D, CS, or other diseases is not clear.


Subject(s)
Cardiomyopathies/complications , Catheter Ablation , Heart Rate , Heart Ventricles/surgery , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/surgery , Ventricular Function, Right , Action Potentials , Adult , Arrhythmogenic Right Ventricular Dysplasia/diagnosis , Arrhythmogenic Right Ventricular Dysplasia/physiopathology , Cardiomyopathies/diagnosis , Cardiomyopathies/physiopathology , Catheter Ablation/adverse effects , Diagnosis, Differential , Electrocardiography , Electrophysiologic Techniques, Cardiac , Female , Heart Ventricles/physiopathology , Humans , Male , Middle Aged , Predictive Value of Tests , Retrospective Studies , Sarcoidosis/diagnosis , Sarcoidosis/physiopathology , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/physiopathology , Time Factors , Treatment Outcome
8.
J Cardiovasc Electrophysiol ; 29(6): 854-860, 2018 06.
Article in English | MEDLINE | ID: mdl-29570900

ABSTRACT

INTRODUCTION: Atrial fibrillation (AF) ablation is increasingly common, but is associated with potential major complications. Technology, experience, and protocols have evolved significantly in recent times, and may have impacted procedural safety. We sought to compare AF ablation safety profiles, including complication rates and fluoroscopy times in a "modern" versus "historical" cohort. METHODS AND RESULTS: We evaluated consecutive patients undergoing AF ablation from a modern cohort (MC) from 2014 to 2015 and a historic cohort (HC) from 2009 to 2011 for complications. Major complications were categorized according to Heart Rhythm Society guidelines. We included 1,425 patients, 726 in the HC and 699 in the MC. The MC was older, had more OSA and less valvular AF. Fifty-two (3.5%) procedures suffered major complications across the cohorts, with significantly fewer in the MC (5.0% vs. 2.3%, P  =  0.007). The largest reductions were seen in vascular, hemorrhagic, ischemic stroke, and perforation/tamponade related complications. Periprocedural antiplatelets drugs (aHR 2.1 [95 CI 1.1-3.9], P  =  0.02) and force-sensing catheters (aHR 0.4 [95 CI 0.2-0.9], P  =  0.03) were independently related to major complication rates. Direct oral anticoagulants and uninterrupted anticoagulation were not associated with complications. There was a decrease in both fluoroscopy (-17.4 minutes [95 CI 19.2-15.6], P < 0.0001) and radiofrequency ablation times (-561 seconds [95CI -750 to -371], P < 0.0001). CONCLUSIONS: The safety profile of AF ablation has improved significantly in less than a decade.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/trends , Postoperative Complications/prevention & control , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/physiopathology , Databases, Factual , Female , Humans , Male , Middle Aged , Patient Safety , Postoperative Complications/epidemiology , Prospective Studies , Radiography, Interventional/trends , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome
9.
Europace ; 20(6): 921-928, 2018 06 01.
Article in English | MEDLINE | ID: mdl-28541417

ABSTRACT

Aims: A commonly held notion is that patients with a family history of atrial fibrillation (AF) have worse atrial substrate and higher rates of arrhythmia recurrence following ablation. We sought to examine differences in atrial substrate and catheter ablation outcomes in patients with a 1st degree family member with paroxysmal or persistent AF (PeAF) compared to those without. Methods and results: A total of 256 consecutive patients undergoing their 1st ablation for AF (123 paroxysmal, 133 persistent) with >1 year follow up were included. The presence of one 1st-degree family relative was defined as a 'positive family history'. Clinical characteristics, electroanatomic map findings, ablation characteristics and outcomes were compared in patients with and without a positive family history of AF. Patients with paroxysmal fibrillation with a positive family history (n = 57; 46%) had similar clinical characteristics and arrhythmia recurrence after catheter ablation as those without. Of those that recurred, patients with a positive family history were more likely to have progressed to PeAF (P = 0.05). Patients with PeAF with a positive family history (n = 75; 56%) had similar clinical characteristics, electroanatomic mapping findings and ablation characteristics, but worse long term arrhythmia free survival (P = 0.04). Conclusion: The presence of a 1st-degree family member with AF does not impact the clinical outcomes of catheter ablation for paroxysmal AF. However, a positive family history is associated with worse arrhythmia free survival in patients with PeAF. This finding is not explained by differences in clinical characteristics, atrial substrate assessed by voltage maps or ablation characteristics.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Atria/physiopathology , Medical History Taking/methods , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Epicardial Mapping/methods , Female , Humans , Male , Middle Aged , Outcome Assessment, Health Care , Prognosis , Progression-Free Survival , Recurrence , Retrospective Studies , Risk Factors , United States
10.
J Cardiovasc Electrophysiol ; 28(1): 56-67, 2017 01.
Article in English | MEDLINE | ID: mdl-27781325

ABSTRACT

AIMS: Catheter ablation can be lifesaving in ventricular tachycardia (VT) storm, but the underlying substrate in patients with storm is not well characterized. We sought to compare the clinical factors, substrate, and outcomes differences in patients with sustained monomorphic VT who present for catheter ablation with VT storm versus those with a nonstorm presentation. METHODS: Consecutive ischemic (ICM; n = 554) or nonischemic cardiomyopathy patients (NICM; n = 369) with a storm versus nonstorm presentation were studied (ICM storm 186; NICM storm 101). RESULTS: In ICM, storm compared with nonstorm patients had significantly lower left ventricular (LV) ejection fraction (EF), greater number of antiarrhythmic drug (AAD) failures, slower VTs, greater number of scarred LV segments, higher incidence of anterior, septal, and apical endocardial LV scar (all P < 0.05). However, outcomes in follow-up were similar (12-month ventricular arrhythmia [VA]-free survival: 51% vs. 52%, P = 0.6; survival free of death/transplant 75% vs. 87%, P = 0.7). In addition to the above differences, NICM storm patients were also older; however, the extent and distribution of scar was similar except for a higher incidence of lateral endocardial scar in storm patients (P = 0.05). VA-free survival (36% vs. 47%, P = 0.004) and survival free of death/transplant, however, were worse in NICM storm than nonstorm patients (72% vs. 88%, P = 0.001). NICM storm patients had worse VA-free survival than ICM storm patients. CONCLUSION: There are differences in clinical factors and scar patterns in patients undergoing VT ablation who present with VT storm versus those with a nonstorm presentation. Clinical outcomes are worse in NICM storm patients.


Subject(s)
Cardiomyopathies/complications , Catheter Ablation , Myocardial Ischemia/complications , Tachycardia, Ventricular/surgery , Action Potentials , Adult , Aged , Anti-Arrhythmia Agents/therapeutic use , Boston , Cardiomyopathies/mortality , Cardiomyopathies/physiopathology , Catheter Ablation/adverse effects , Cicatrix/etiology , Cicatrix/physiopathology , Disease Progression , Disease-Free Survival , Female , Heart Rate , Heart Transplantation , Humans , Male , Middle Aged , Myocardial Ischemia/mortality , Myocardial Ischemia/physiopathology , Proportional Hazards Models , Retrospective Studies , Risk Factors , Stroke Volume , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/mortality , Tachycardia, Ventricular/physiopathology , Time Factors , Treatment Outcome , Ventricular Function, Left
11.
J Cardiovasc Electrophysiol ; 27(12): 1390-1398, 2016 12.
Article in English | MEDLINE | ID: mdl-27581553

ABSTRACT

OBJECTIVE: To correlate impedance decrease during atrial fibrillation (AF) ablation with lesion durability and PV conduction recovery demonstrated during redo procedures. BACKGROUND: Markers of successful ablation beyond acute conduction block are needed to improve durability of pulmonary vein (PV) isolation (PVI). Local impedance decrease resulting from ablation is a real-time marker of tissue heating and is correlated with lesion creation. METHODS: Impedance changes associated with point-by-point radiofrequency ablation in the PV antra were recorded during 167 consecutive first-time AF ablations. During clinically indicated redo procedures, sites of recovered PV conduction were identified, and were correlated with the impedance change achieved during ablation at these locations during the initial procedure. RESULTS: Redo procedures were performed in 28 patients, in whom 19 sites of recovered PV conduction were documented. Most sites of PV reconnection (58%) occurred along the posterior PV antra. Ablation resulting in impedance decrease <10 ohms during the initial procedure was present in 89% (17/19) of sites with conduction recovery. Regions with adjacent ablation resulting in impedance decrease <10 ohms were associated with a higher rate of conduction recovery (37% vs. 1.5%, P < 0.001). Likewise, patients with PV conduction recovery demonstrated during redo procedure (Group 1) had larger regions where ablation resulted in <10 ohm impedance decrease than patients without PV conduction recovery (Group 2) (21.9 ± 15.5 mm vs. 11.5 ± 2.1 mm, P < 0.01). CONCLUSION: Recovered PV conduction occurs predominantly in regions where adjacent ablation applications result in impedance decreases <10 ohms. Impedance-guided ablation strategies may improve durability of PVI.


Subject(s)
Action Potentials , Atrial Fibrillation/surgery , Catheter Ablation , Pulmonary Veins/surgery , Adult , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Electric Impedance , Electrophysiologic Techniques, Cardiac , Female , Heart Rate , Humans , Male , Middle Aged , Pulmonary Veins/physiopathology , Recurrence , Reoperation , Retrospective Studies , Treatment Outcome
12.
J Minim Access Surg ; 12(2): 170-2, 2016.
Article in English | MEDLINE | ID: mdl-27073312

ABSTRACT

Acute appendicitis is one of the commonest surgical emergencies worldwide. There is considerable variation in prevalence of appendicoliths with appendicitis. Most of the patients with appendicoliths are asymptomatic and they are not pathognomic for acute appendicitis. However, appendicoliths show increased association with perforation and abscess formation. Appendicolith are quite common, being present in 3% of general population and in nearly 10% cases of appendicitis. However, giant appendicoliths measuring over 2 centimeters (cms) are extremely rare. Computed Tomography (CT) has increased their pre-operative diagnosis considerably. Use of spectral analysis can give us the details of composition of the stone pre-operatively. We present a young male diagnosed pre-operatively on Non-Contrast Computed Tomography (NCCT) to have a giant calcium struvite appendicolith. On laparoscopy he had a 3 cm stone and an incidental Meckel's diverticulum and underwent appendectomy. The case is presented for the unique size of the appendicolith alongwith review of literature.

13.
Card Electrophysiol Clin ; 16(2): 125-132, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749630

ABSTRACT

The population of patients with advanced heart failure continues to increase steadily as does the need for mechanical circulatory support. Combination therapy with left ventricular assist devices (LVADs) and cardiovascular implantable electronic devices (CIEDs) is unavoidable. CIED complications in patients with LVADs are common and often necessitate device system revision and transvenous lead extraction. Despite this, management recommendations are limited, and guidelines are lacking.


Subject(s)
Device Removal , Heart Failure , Heart-Assist Devices , Humans , Heart-Assist Devices/adverse effects , Device Removal/methods , Heart Failure/therapy , Heart Failure/surgery , Defibrillators, Implantable/adverse effects
14.
Clin Transl Gastroenterol ; 15(6): e00717, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38752627

ABSTRACT

INTRODUCTION: Gastroesophageal reflux disease (GERD) has been associated with increased incidence/recurrence of atrial fibrillation (AF). However, the impact of GERD and proton pump inhibitor (PPI) therapy on outcomes of AF catheter ablation remains unclear. We aimed to assess the association between the presence of GERD and risk of repeat AF ablation, stratified by PPI therapy. METHODS: A retrospective cohort study was conducted on patients with paroxysmal/persistent AF undergoing initial ablation in January 2011-September 2015. GERD was defined by endoscopic findings, objective reflux testing, or clinical symptoms. The association between GERD/PPI use and time to repeat ablation was evaluated by time-to-event analysis with censoring at the last clinic follow-up within 1 year. RESULTS: Three hundred eighty-one subjects were included. Patients with GERD (n = 80) had a higher 1-year repeat ablation rate compared with those with no GERD (25% vs 11.3%, P = 0.0034). Stratifying by PPI use, patients with untreated GERD (37.5%) more likely needed repeat ablation compared with reflux-free (11.3%, P = 0.0003) and treated GERD (16.7%, P = 0.035) subjects. On multivariable Cox regression analyses, GERD was an independent risk factor of repeat ablation (hazard ratio [HR] 3.30, confidence interval [CI] 1.79-6.08, P = 0.0001). Specifically, untreated GERD was associated with earlier repeat ablation compared with no GERD (HR 4.02, CI 1.62-12.05, P = 0.0013). However, no significant difference in repeat ablation risk was noted between reflux-free and PPI-treated GERD groups. DISCUSSION: GERD was an independent predictor for risk of repeat AF ablation within 1 year, even after controlling for major cardiovascular comorbidities and confounders. PPI therapy modulated this risk, as repeat ablation-free survival for PPI-treated GERD was noninferior to reflux-free patients.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Gastroesophageal Reflux , Proton Pump Inhibitors , Recurrence , Humans , Gastroesophageal Reflux/drug therapy , Gastroesophageal Reflux/surgery , Gastroesophageal Reflux/complications , Proton Pump Inhibitors/therapeutic use , Proton Pump Inhibitors/adverse effects , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Male , Female , Retrospective Studies , Middle Aged , Catheter Ablation/adverse effects , Aged , Risk Factors , Reoperation/statistics & numerical data , Treatment Outcome
15.
Stroke Vasc Neurol ; 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38862182

ABSTRACT

BACKGROUND: The occurrence of acute ischaemic stroke (AIS) while using oral anticoagulants (OAC) is an increasingly recognised problem among nonvalvular atrial fibrillation (NVAF) patients. We aimed to elucidate the potential role of left atrial appendage closure (LAAC) for stroke prevention in patients with AIS despite OAC use (AIS-despite-OAC). METHODS: We retrospectively collected baseline and follow-up data from consecutive NVAF patients who had AIS-despite-OAC and subsequently underwent endovascular LAAC, between January 2015 and October 2021. The primary outcome measure was the occurrence of AIS after LAAC, and the safety outcome was symptomatic intracerebral haemorrhage (ICH). RESULTS: 29 patients had LAAC specifically because of AIS-despite-OAC. The mean age at the time of the procedure was 73.4±8.7, 13 were female (44.82%). The mean CHA2DS2-VASc score was 5.96±1.32, with an expected AIS risk of 8.44 per 100 patient-years. 14 patients (48%) had two or more past AIS-despite-OAC. After LAAC, 27 patients (93.10%) were discharged on OAC which was discontinued in 17 (58.62%) after transoesophageal echocardiogram at 6 weeks. Over a mean of 1.75±1.0 years follow-up after LAAC, one patient had an AIS (incidence rate (IR) 1.97 per 100 patient-years). One patient with severe cerebral microangiopathy had a small ICH while on direct OAC and antiplatelet 647 days after LAAC. CONCLUSIONS: LAAC in AIS-despite-OAC patients demonstrated a low annual AIS recurrence rate in our cohort (1.97%) compared with the expected IR based on their CHA2DS2-VASc scores (8.44%) and to recent large series of AIS-despite-OAC patients treated with OAC/aspirin only (5.3%-8.9%). These hypothesis-generating findings support randomised trials of LAAC in AIS-despite-OAC patients.

16.
Stroke Vasc Neurol ; 2024 May 30.
Article in English | MEDLINE | ID: mdl-38821554

ABSTRACT

BACKGROUND AND OBJECTIVES: Although left atrial appendage closure (LAAC) is performed in patients with non-valvular atrial fibrillation (NVAF) at increased risk of intracranial haemorrhage (ICH), outcome data are scarce. We assessed the detailed neurological indications for LAAC and outcomes after LAAC in high ICH risk patients. METHODS: Study population included consecutive patients with NVAF who underwent LAAC in a single hospital network between January 2015 and October 2021 because of prior ICH or the presence of high ICH risk imaging markers on brain MRI (cerebral microbleeds (CMBs)). Primary safety and efficacy outcome measures were the occurrence of ICH and thromboembolic events, respectively, after LAAC. RESULTS: Among 146 patients with NVAF who underwent LAAC for high ICH risk, 122 had a history of ICH, while 24 presented with high ICH risk imaging markers only. Mean age was 75.7±7.61, 42 (28.8%) were women. Mean CHA2DS2-VASc score was 5.23±1.52. Of 122 patients with ICH history, 58 (47.5%) had intraparenchymal haemorrhage (IPH), 40 (32.8%) had traumatic ICH (T-ICH) and 18 (14.7%) had non-traumatic subdural haemorrhage. Of 85 patients with brain MRIs including necessary sequences, 43 (50.6%) were related to cerebral amyloid angiopathy and 37 (43.5%) to hypertensive microangiopathy. While 70% of patients were discharged on oral anticoagulants (OAC), 92% were not taking OAC at 1 year. Over 2.12 years mean follow-up, one patient had recurrent non-traumatic IPH (incidence rate (IR) 0.32 per 100 patient-years), five had T-ICH (IR 1.61 per 100 patient-years) and six had an ischaemic stroke (IR 1.94 per 100 patient-years). CONCLUSIONS: Among patients with NVAF at high ICH risk, LAAC demonstrated a low risk of recurrent ICH or ischaemic stroke compared with previously published data. LAAC in high ICH risk populations should be considered in clinical practice per FDA approval and recent guidelines.

17.
Article in English | MEDLINE | ID: mdl-38668934

ABSTRACT

BACKGROUND: Left bundle branch area pacing (LBBAP) has emerged as a physiological alternative pacing strategy to biventricular pacing (BIVP) in cardiac resynchronization therapy (CRT). We aimed to assess the impact of LBBAP vs. BIVP on all-cause mortality and heart failure (HF)-related hospitalization in patients undergoing CRT. METHODS: Studies comparing LBBAP and BIVP for CRT in patients with HF with reduced left ventricular ejection fraction (LVEF) were included. The coprimary outcomes were all-cause mortality and HF-related hospitalization. Secondary outcomes included procedural and fluoroscopy time, change in QRS duration, and change in LVEF. RESULTS: Thirteen studies (12 observational and 1 RCT, n = 3239; LBBAP = 1338 and BIVP = 1901) with a mean follow-up duration of 25.8 months were included. Compared to BIVP, LBBAP was associated with a significant absolute risk reduction of 3.2% in all-cause mortality (9.3% vs 12.5%, RR 0.7, 95% CI 0.57-0.86, p < 0.001) and an 8.2% reduction in HF-related hospitalization (11.3% vs 19.5%, RR 0.6, 95% CI 0.5-0.71, p < 0.00001). LBBAP also resulted in reductions in procedural time (mean weighted difference- 23.2 min, 95% CI - 42.9 to - 3.6, p = 0.02) and fluoroscopy time (- 8.6 min, 95% CI - 12.5 to - 4.7, p < 0.001) as well as a significant reduction in QRS duration (mean weighted difference:- 25.3 ms, 95% CI - 30.9 to - 19.8, p < 0.00001) and a greater improvement in LVEF of 5.1% (95% CI 4.4-5.8, p < 0.001) compared to BIVP in the studies that reported these outcomes. CONCLUSION: In this meta-analysis, LBBAP was associated with a significant reduction in all-cause mortality as well as HF-related hospitalization when compared to BIVP. Additional data from large RCTs is warranted to corroborate these promising findings.

18.
JACC Clin Electrophysiol ; 10(2): 295-305, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38127008

ABSTRACT

BACKGROUND: Left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP) are considered to be acceptable as LBBAP strategies. Differences in clinical outcomes between LBBP and LVSP are yet to be determined. OBJECTIVES: The purpose of this study was to compare the outcomes of LBBP vs LVSP vs BIVP for CRT. METHODS: In this prospective multicenter observational study, LBBP was compared with LVSP and BIVP in patients undergoing CRT. The primary composite outcome was freedom from heart failure (HF)-related hospitalization and all-cause mortality. Secondary outcomes included individual components of the primary outcome, postprocedural NYHA functional class, and electrocardiographic and echocardiographic parameters. RESULTS: A total of 415 patients were included (LBBP: n = 141; LVSP: n = 31; BIVP: n = 243), with a median follow-up of 399 days (Q1-Q3: 249.5-554.8 days). Freedom from the primary composite outcomes was 76.6% in the LBBP group and 48.4% in the LVSP group (HR: 1.37; 95% CI: 1.143-1.649; P = 0.001), driven by a 31.4% absolute increase in freedom from HF-related hospitalizations (83% vs 51.6%; HR: 3.55; 95% CI: 1.856-6.791; P < 0.001) without differences in all-cause mortality. LBBP was also associated with a higher freedom from the primary composite outcome compared with BIVP (HR: 1.43; 95% CI: 1.175-1.730; P < 0.001), with no difference between LVSP and BIVP. CONCLUSIONS: In patients undergoing CRT, LBBP was associated with improved outcomes compared with LVSP and BIVP, while outcomes between BIVP and LVSP are similar.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Cardiac Resynchronization Therapy/adverse effects , Prospective Studies , Heart Conduction System , Heart Ventricles , Electrocardiography
19.
Article in English | MEDLINE | ID: mdl-38499825

ABSTRACT

BACKGROUND: Cardioneuroablation has been emerging as a potential treatment alternative in appropriately selected patients with cardioinhibitory vasovagal syncope (VVS) and functional AV block (AVB). However the majority of available evidence has been derived from retrospective cohort studies performed by experienced operators. METHODS: The Cardioneuroablation for the Management of Patients with Recurrent Vasovagal Syncope and Symptomatic Bradyarrhythmias (CNA-FWRD) Registry is a multicenter prospective registry with cross-over design evaluating acute and long-term outcomes of VVS and AVB patients treated by conservative therapy and CNA. RESULTS: The study is a prospective observational registry with cross-over design for analysis of outcomes between a control group (i.e., behavioral and medical therapy only) and intervention group (Cardioneuroablation). Primary and secondary outcomes will only be assessed after enrollment in the registry. The follow-up period will be 3 years after enrollment. CONCLUSIONS: There remains a lack of prospective multicentered data for long-term outcomes comparing conservative therapy to radiofrequency CNA procedures particularly for key outcomes including recurrence of syncope, AV block, durable impact of disruption of the autonomic nervous system, and long-term complications after CNA. The CNA-FWRD registry has the potential to help fill this information gap.

20.
Curr Cardiol Rep ; 15(11): 419, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24057773

ABSTRACT

The left atrial appendage (LAA) is a prominent source of cardioembolic stroke in patients with nonvalvular atrial fibrillation (AF). While systemic anticoagulation is the common therapeutic choice, these medications carry many contraindications and possible complications. Epicardial and endovascular techniques for occlusion of LAA have been explored and early clinical data is accumulating. In the coming years, this data will help guide the management of AF patients at risk of bleeding as well as potentially become first-line therapy to reduce the risk of thromboembolic stroke. The purpose of this article is to review current endovascular and epicardial catheter based LAA occlusion devices and the clinical data supporting their use.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Catheterization , Endovascular Procedures/methods , Hemorrhage/prevention & control , Stroke/prevention & control , Thromboembolism/prevention & control , Anticoagulants/administration & dosage , Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Atrial Appendage/physiopathology , Atrial Fibrillation/complications , Atrial Fibrillation/physiopathology , Boston/epidemiology , Female , Hemorrhage/chemically induced , Humans , Male , Percutaneous Coronary Intervention/methods , Risk Assessment , Stroke/epidemiology , Stroke/etiology , Thromboembolism/epidemiology , Thromboembolism/etiology , Treatment Outcome
SELECTION OF CITATIONS