Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 259
Filter
Add more filters

Publication year range
1.
N Engl J Med ; 390(2): 107-117, 2024 Jan 11.
Article in English | MEDLINE | ID: mdl-37952132

ABSTRACT

BACKGROUND: Subclinical atrial fibrillation is short-lasting and asymptomatic and can usually be detected only by long-term continuous monitoring with pacemakers or defibrillators. Subclinical atrial fibrillation is associated with an increased risk of stroke by a factor of 2.5; however, treatment with oral anticoagulation is of uncertain benefit. METHODS: We conducted a trial involving patients with subclinical atrial fibrillation lasting 6 minutes to 24 hours. Patients were randomly assigned in a double-blind, double-dummy design to receive apixaban at a dose of 5 mg twice daily (2.5 mg twice daily when indicated) or aspirin at a dose of 81 mg daily. The trial medication was discontinued and anticoagulation started if subclinical atrial fibrillation lasting more than 24 hours or clinical atrial fibrillation developed. The primary efficacy outcome, stroke or systemic embolism, was assessed in the intention-to-treat population (all the patients who had undergone randomization); the primary safety outcome, major bleeding, was assessed in the on-treatment population (all the patients who had undergone randomization and received at least one dose of the assigned trial drug, with follow-up censored 5 days after permanent discontinuation of trial medication for any reason). RESULTS: We included 4012 patients with a mean (±SD) age of 76.8±7.6 years and a mean CHA2DS2-VASc score of 3.9±1.1 (scores range from 0 to 9, with higher scores indicating a higher risk of stroke); 36.1% of the patients were women. After a mean follow-up of 3.5±1.8 years, stroke or systemic embolism occurred in 55 patients in the apixaban group (0.78% per patient-year) and in 86 patients in the aspirin group (1.24% per patient-year) (hazard ratio, 0.63; 95% confidence interval [CI], 0.45 to 0.88; P = 0.007). In the on-treatment population, the rate of major bleeding was 1.71% per patient-year in the apixaban group and 0.94% per patient-year in the aspirin group (hazard ratio, 1.80; 95% CI, 1.26 to 2.57; P = 0.001). Fatal bleeding occurred in 5 patients in the apixaban group and 8 patients in the aspirin group. CONCLUSIONS: Among patients with subclinical atrial fibrillation, apixaban resulted in a lower risk of stroke or systemic embolism than aspirin but a higher risk of major bleeding. (Funded by the Canadian Institutes of Health Research and others; ARTESIA ClinicalTrials.gov number, NCT01938248.).


Subject(s)
Anticoagulants , Aspirin , Atrial Fibrillation , Embolism , Stroke , Aged , Aged, 80 and over , Female , Humans , Male , Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Aspirin/adverse effects , Aspirin/therapeutic use , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Canada , Embolism/etiology , Embolism/prevention & control , Hemorrhage/chemically induced , Pyridones/adverse effects , Stroke/etiology , Stroke/prevention & control , Treatment Outcome , Factor Xa Inhibitors/adverse effects , Factor Xa Inhibitors/therapeutic use , Double-Blind Method
2.
Circulation ; 148(3): 241-252, 2023 07 18.
Article in English | MEDLINE | ID: mdl-37459413

ABSTRACT

BACKGROUND: Black Americans have a higher risk of nonischemic cardiomyopathy (NICM) than White Americans. We aimed to evaluate differences in the risk of tachyarrhythmias among patients with an implantable cardioverter-defibrillator (ICD). METHODS: The study population comprised 3895 ICD recipients in the United States enrolled in primary prevention ICD trials. Outcome measures included ventricular tachyarrhythmia (VTA), atrial tachyarrhythmia (ATA), ICD therapies, VTA burden (using Andersen-Gill recurrent event analysis), death, and the predicted benefit of the ICD. All events were adjudicated blindly. Outcomes were compared between self-reported Black patients versus White patients with cardiomyopathy (ischemic and NICM). RESULTS: Black patients were more likely to be female (35% versus 22%) and younger (57±12 versus 62±12 years) with a higher frequency of comorbidities. In NICM, Black patients had a higher rate of first VTA, fast VTA, ATA, and appropriate and inappropriate ICD therapy (VTA ≥170 bpm, 32% versus 20%; VTA ≥200 bpm, 22% versus 14%; ATA, 25% versus 12%; appropriate therapy, 30% versus 20%; and inappropriate therapy, 25% versus 11%; P<0.001 for all). Multivariable analysis showed that Black patients with NICM experienced a higher risk of all types of arrhythmia or ICD therapy (VTA ≥170 bpm, hazard ratio [HR] 1.71; VTA ≥200 bpm, HR 1.58; ATA, HR 1.87; appropriate therapy, HR 1.62; inappropriate therapy, HR 1.86; P≤0.01 for all), higher burden of tachyarrhythmias or therapies (VTA, HR 1.84; appropriate therapy, HR 1.84; P<0.001 for both), and a higher risk of death (HR 1.92; P=0.014). In contrast, in ischemic cardiomyopathy, the risk of all types of tachyarrhythmia, ICD therapy, or death was similar between Black patients and White patients. Both Black patients and White patients derived a significant and similar benefit from ICD implantation. CONCLUSIONS: Among patients with NICM with an ICD for primary prevention, Black patients compared with White patients had a high risk and burden of VTA, ATA, and ICD therapies with a lower survival rate. Nevertheless, the overall benefit of the ICD was maintained and was similar to that of White patients.


Subject(s)
Cardiomyopathies , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Female , United States/epidemiology , Male , White , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Risk Factors , Arrhythmias, Cardiac , Tachycardia, Ventricular/therapy , Tachycardia, Ventricular/epidemiology , Primary Prevention
3.
Circulation ; 147(10): 812-823, 2023 03 07.
Article in English | MEDLINE | ID: mdl-36700426

ABSTRACT

BACKGROUND: Benefit from cardiac resynchronization therapy (CRT) varies by QRS characteristics; individual randomized trials are underpowered to assess benefit for relatively small subgroups. METHODS: The authors analyzed patient-level data from pivotal CRT trials (MIRACLE [Multicenter InSync Randomized Clinical Evaluation], MIRACLE-ICD [Multicenter InSync ICD Randomized Clinical Evaluation], MIRACLE-ICD II [Multicenter InSync ICD Randomized Clinical Evaluation II], REVERSE [Resynchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction], RAFT [Resynchronization-Defibrillation for Ambulatory Heart Failure], BLOCK-HF [Biventricular Versus Right Ventricular Pacing in Heart Failure Patients with Atrioventricular Block], COMPANION [Comparison of Medical Therapy, Pacing and Defibrillation in Heart Failure], and MADIT-CRT [Multicenter Automatic Defibrillator Implantation Trial - Cardiac Resynchronization Therapy]) using Bayesian Hierarchical Weibull survival regression models to assess CRT benefit by QRS morphology (left bundle branch block [LBBB], n=4549; right bundle branch block [RBBB], n=691; and intraventricular conduction delay [IVCD], n=1024) and duration (with 150-ms partition). The continuous relationship between QRS duration and CRT benefit was also examined within subgroups defined by QRS morphology. The primary end point was time to heart failure hospitalization (HFH) or death; a secondary end point was time to all-cause death. RESULTS: Of 6264 patients included, 25% were women, the median age was 66 [interquartile range, 58 to 73] years, and 61% received CRT (with or without an implantable cardioverter defibrillator). CRT was associated with an overall lower risk of HFH or death (hazard ratio [HR], 0.73 [credible interval (CrI), 0.65 to 0.84]), and in subgroups of patients with QRS ≥150 ms and either LBBB (HR, 0.56 [CrI, 0.48 to 0.66]) or IVCD (HR, 0.59 [CrI, 0.39 to 0.89]), but not RBBB (HR 0.97 [CrI, 0.68 to 1.34]; Pinteraction <0.001). No significant association for CRT with HFH or death was observed when QRS was <150 ms (regardless of QRS morphology) or in the presence of RBBB. Similar relationships were observed for all-cause death. CONCLUSIONS: CRT is associated with reduced HFH or death in patients with QRS ≥150 ms and LBBB or IVCD, but not for those with RBBB. Aggregating RBBB and IVCD into a single "non-LBBB" category when selecting patients for CRT should be reconsidered. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifiers: NCT00271154, NCT00251251, NCT00267098, and NCT00180271.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Female , Aged , Male , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Bundle-Branch Block/complications , Cardiac Resynchronization Therapy/adverse effects , Bayes Theorem , Randomized Controlled Trials as Topic , Defibrillators, Implantable/adverse effects , Treatment Outcome , Electrocardiography
4.
Am Heart J ; 267: 81-90, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37984672

ABSTRACT

BACKGROUND: Cardiac resynchronization therapy (CRT) reduces heart failure hospitalizations (HFH) and mortality for guideline-indicated patients with heart failure (HF). Most patients with HF are aged ≥70 years but such patients are often under-represented in randomized trials. METHODS: Patient-level data were combined from 8 randomized trials published 2002-2013 comparing CRT to no CRT (n = 6,369). The effect of CRT was estimated using an adjusted Bayesian survival model. Using age as a categorical (<70 vs ≥70 years) or continuous variable, the interaction between age and CRT on the composite end point of HFH or all-cause mortality or all-cause mortality alone was assessed. RESULTS: The median age was 67 years with 2436 (38%) being 70+; 1,554 (24%) were women; 2,586 (41%) had nonischemic cardiomyopathy and median QRS duration was 160 ms. Overall, CRT was associated with a delay in time to the composite end point (adjusted hazard ratio [aHR] 0.75, 95% credible interval [CI] 0.66-0.85, P = .002) and all-cause mortality alone (aHR of 0.80, 95% CI 0.69-0.96, P = .017). When age was treated as a categorical variable, there was no interaction between age and the effect of CRT for either end point (P > .1). When age was treated as a continuous variable, older patients appeared to obtain greater benefit with CRT for the composite end point (P for interaction = .027) with a similar but nonsignificant trend for mortality (P for interaction = .35). CONCLUSION: Reductions in HFH and mortality with CRT are as great or greater in appropriately indicated older patients. Age should not be a limiting factor for the provision of CRT.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Female , Aged , Male , Bayes Theorem , Treatment Outcome , Heart Failure/therapy , Proportional Hazards Models
5.
J Cardiovasc Electrophysiol ; 35(4): 785-793, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38383981

ABSTRACT

INTRODUCTION: Wearable cardioverter defibrillator (WCD) is utilized in patients with assumed but not yet confirmed risk for sudden cardiac death (SCD). Many of these patients also present with atrial fibrillation (AF). However, the rate of WCD-detected ventricular or atrial arrhythmia events in this specific high-risk cohort is not well understood. METHODS: In WEARIT-II, the cumulative probability of any sustained or nonsustained VT/VF (WCD-treated and nontreated), and atrial/supraventricular arrhythmias during WCD use was assessed using the Kaplan-Meier method by prior AF, with comparisons by the log-rank test. The incidence of ventricular and atrial arrhythmia events were expressed as events per 100 patient-years, and were analyzed by prior AF using negative binomial regression. RESULTS: WEARIT-II enrolled 2000 patients, 557 (28%) of whom had AF before enrollment. Cumulative probability of any sustained or nonsustained WCD-detected VT/VF during WCD use was significantly higher among patients with a history of AF than without AF (6% vs. 3%, p = .001). Similarly, the recurrent rate of any sustained or nonsustained VT/VF was significantly higher in patients with prior AF versus no prior AF (131.5 events per 100 patient-years vs. 22.7 events per 100 patient-years, p = .001). Patients with prior AF also had a significantly higher burden of any WCD-detected atrial arrhythmias/SVT/inappropriate arrhythmias therapy (183.2 events per 100 patient-years vs. 74.8 events per 100 patient-years, p < .001). CONCLUSION: Our results demonstrate that patients with a history of AF wearing the WCD for risk assessment have a higher incidence of ventricular arrhythmias that may facilitate the decision making for ICD implantation.


Subject(s)
Atrial Fibrillation , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Atrial Fibrillation/complications , Electric Countershock/adverse effects , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Risk Assessment , Registries , Defibrillators, Implantable/adverse effects
6.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38743765

ABSTRACT

Imaging using cardiac computed tomography (CT) or magnetic resonance (MR) imaging has become an important option for anatomic and substrate delineation in complex atrial fibrillation (AF) and ventricular tachycardia (VT) ablation procedures. Computed tomography more common than MR has been used to detect procedure-associated complications such as oesophageal, cerebral, and vascular injury. This clinical consensus statement summarizes the current knowledge of CT and MR to facilitate electrophysiological procedures, the current value of real-time integration of imaging-derived anatomy, and substrate information during the procedure and the current role of CT and MR in diagnosing relevant procedure-related complications. Practical advice on potential advantages of one imaging modality over the other is discussed for patients with implanted cardiac rhythm devices as well as for planning, intraprocedural integration, and post-interventional management in AF and VT ablation patients. Establishing a team of electrophysiologists and cardiac imaging specialists working on specific details of imaging for complex ablation procedures is key. Cardiac magnetic resonance (CMR) can safely be performed in most patients with implanted active cardiac devices. Standard procedures for pre- and post-scanning management of the device and potential CMR-associated device malfunctions need to be in place. In VT patients, imaging-specifically MR-may help to determine scar location and mural distribution in patients with ischaemic and non-ischaemic cardiomyopathy beyond evaluating the underlying structural heart disease. Future directions in imaging may include the ability to register multiple imaging modalities and novel high-resolution modalities, but also refinements of imaging-guided ablation strategies are expected.


Subject(s)
Consensus , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Humans , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Predictive Value of Tests , Europe , Treatment Outcome
7.
Eur Heart J ; 44(40): 4259-4269, 2023 Oct 21.
Article in English | MEDLINE | ID: mdl-37632437

ABSTRACT

BACKGROUND AND AIMS: De novo implanted cardiac resynchronization therapy with defibrillator (CRT-D) reduces the risk of morbidity and mortality in patients with left bundle branch block, heart failure and reduced ejection fraction (HFrEF). However, among HFrEF patients with right ventricular pacing (RVP), the efficacy of CRT-D upgrade is uncertain. METHODS: In this multicentre, randomized, controlled trial, 360 symptomatic (New York Heart Association Classes II-IVa) HFrEF patients with a pacemaker or implantable cardioverter defibrillator (ICD), high RVP burden ≥ 20%, and a wide paced QRS complex duration ≥ 150 ms were randomly assigned to receive CRT-D upgrade (n = 215) or ICD (n = 145) in a 3:2 ratio. The primary outcome was the composite of all-cause mortality, heart failure hospitalization, or <15% reduction of left ventricular end-systolic volume assessed at 12 months. Secondary outcomes included all-cause mortality or heart failure hospitalization. RESULTS: Over a median follow-up of 12.4 months, the primary outcome occurred in 58/179 (32.4%) in the CRT-D arm vs. 101/128 (78.9%) in the ICD arm (odds ratio 0.11; 95% confidence interval 0.06-0.19; P < .001). All-cause mortality or heart failure hospitalization occurred in 22/215 (10%) in the CRT-D arm vs. 46/145 (32%) in the ICD arm (hazard ratio 0.27; 95% confidence interval 0.16-0.47; P < .001). The incidence of procedure- or device-related complications was similar between the two arms [CRT-D group 25/211 (12.3%) vs. ICD group 11/142 (7.8%)]. CONCLUSIONS: In pacemaker or ICD patients with significant RVP burden and reduced ejection fraction, upgrade to CRT-D compared with ICD therapy reduced the combined risk of all-cause mortality, heart failure hospitalization, or absence of reverse remodelling.

8.
J Cardiovasc Electrophysiol ; 34(9): 1914-1924, 2023 09.
Article in English | MEDLINE | ID: mdl-37522254

ABSTRACT

AIMS: To investigate the association of cardiac resynchronization therapy (CRT) on outcomes among participants with and without a history of atrial fibrillation (AF). METHODS: Individual-patient-data from four randomized trials investigating CRT-Defibrillators (COMPANION, MADIT-CRT, REVERSE) or CRT-Pacemakers (COMPANION, MIRACLE) were analyzed. Outcomes were time to a composite of heart failure hospitalization or all-cause mortality or to all-cause mortality alone. The association of CRT on outcomes for patients with and without a history of AF was assessed using a Bayesian-Weibull survival regression model adjusting for baseline characteristics. RESULTS: Of 3964 patients included, 586 (14.8%) had a history of AF; 2245 (66%) were randomized to CRT. Overall, CRT reduced the risk of the primary composite endpoint (hazard ratio [HR]: 0.69, 95% credible interval [CI]: 0.56-0.81). The effect was similar (posterior probability of no interaction = 0.26) in patients with (HR: 0.78, 95% CI: 0.55-1.10) and without a history of AF (HR: 0.67, 95% CI: 0.55-0.80). In these four trials, CRT did not reduce mortality overall (HR: 0.82, 95% CI: 0.66-1.01) without evidence of interaction (posterior probability of no interaction = 0.14) for patients with (HR: 1.09, 95% CI: 0.70-1.74) or without a history of AF (HR: 0.70, 95% CI: 0.60-0.97). CONCLUSION: The association of CRT on the composite endpoint or mortality was not statistically different for patients with or without a history of AF, but this could reflect inadequate power. Our results call for trials to confirm the benefit of CRT recipients with a history of AF.


Subject(s)
Atrial Fibrillation , Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Cardiac Resynchronization Therapy/methods , Bayes Theorem , Treatment Outcome , Heart Failure/diagnosis , Heart Failure/therapy
9.
Europace ; 25(3): 956-960, 2023 03 30.
Article in English | MEDLINE | ID: mdl-36636968

ABSTRACT

AIMS: Intraoperative defibrillation testing (DT) during implant or replacement of implantable cardioverter-defibrillators (ICDs) has been a matter of debate for many years. This debate was put to rest by the Simple and Nordic ICD trials, and the practice of testing during new implantations has essentially been almost abandoned. Old registries demonstrated an increased incidence of significant findings in DT during replacements. The aim of the present study was to evaluate frequency of significant findings and safety of DT in subjects undergoing device replacement. METHODS AND RESULTS: A prospective observational multi-centre study included consecutive patients undergoing ICD generator replacement. The primary outcome was a failure to terminate induced ventricular fibrillation (VF) with a single shock 10 J below the maximal capacity of the device. Secondary outcomes included complications of DT. Patients were followed-up at 1- and 6-months post-procedure. A total of 92 patients were eligible, and consented to the study, of which 84 underwent DT during battery replacement. The median age was 68 years and 79.8% were males. Induction of VF was successful in 84 patients as was a successful conversion on the first attempt in all. There were no procedure-related complications. During follow up one patient had two appropriate ICD shock events. In four patients, ICD programming was changed. None suffered inappropriate shock. There was no evidence of lead malfunction. Two deaths occurred, none of which was related to arrhythmia. CONCLUSION: The present study found DT was not associated with complications in patients undergoing ICD generator replacement but produced no clinically important information.


Subject(s)
Defibrillators, Implantable , Male , Humans , Aged , Female , Defibrillators, Implantable/adverse effects , Arrhythmias, Cardiac/etiology , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/etiology , Ventricular Fibrillation/therapy
10.
Ann Noninvasive Electrocardiol ; 28(2): e13043, 2023 03.
Article in English | MEDLINE | ID: mdl-36718801

ABSTRACT

BACKGROUND: Percutaneous catheter ablation (CA) to achieve pulmonary vein isolation is an effective treatment for drug-refractory paroxysmal and persistent atrial fibrillation (AF). However, recurrence rates after a single AF ablation procedure remain elevated. Conventional management after CA ablation has mostly been based on clinical AF recurrence. However, continuous recordings with insertable cardiac monitors (ICMs) and patient-triggered mobile app transmissions post-CA can now be used to detect early recurrences of subclinical AF (SCAF). We hypothesize that early intervention following CA based on personalized ICM data can prevent the substrate progression that promotes the onset and maintenance of atrial arrhythmias. METHODS: This is a randomized, double-blind (to SCAF data), single-tertiary center clinical trial in which 120 patients with drug-refractory paroxysmal or persistent AF are planned to undergo CA with an ICM. Randomization will be to an intervention arm (n = 60) consisting of ICM-guided early intervention based on SCAF and patient-triggered mobile app transmissions versus a control arm (n = 60) consisting of a standard intervention protocol based on clinical AF recurrence validated by the ICM. Primary endpoint is AF burden, which will be assessed from ICMs at 15 months post-AF ablation. Secondary endpoints include healthcare utilization, functional capacity, and quality of life. CONCLUSION: We believe that ICM-guided early intervention will provide a novel, personalized approach to post-AF ablation management that will result in a significant reduction in AF burden, healthcare utilization, and improvements in functional capacity and quality of life.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Quality of Life , Electrocardiography , Treatment Outcome , Clinical Protocols , Catheter Ablation/methods , Recurrence , Randomized Controlled Trials as Topic
11.
Ann Noninvasive Electrocardiol ; 28(5): e13073, 2023 09.
Article in English | MEDLINE | ID: mdl-37515396

ABSTRACT

BACKGROUND: The use of a Left Ventricular Assist Device (LVAD) in patients with advanced heart failure refractory to optimal medical management has progressed steadily over the past two decades. Data have demonstrated reduced LVAD efficacy, worse clinical outcome, and higher mortality for patients who experience significant ventricular tachyarrhythmia (VTA). We hypothesize that a novel prophylactic intra-operative VTA ablation protocol at the time of LVAD implantation may reduce the recurrent VTA and adverse events postimplant. METHODS: We designed a prospective, multicenter, open-label, randomized-controlled clinical trial enrolling 100 patients who are LVAD candidates with a history of VTA in the previous 5 years. Enrolled patients will be randomized in a 1:1 fashion to intra-operative VTA ablation (n = 50) versus conventional medical management (n = 50) with LVAD implant. Arrhythmia outcomes data will be captured by an implantable cardioverter defibrillator (ICD) to monitor VTA events, with a uniform ICD programming protocol. Patients will be followed prospectively over a mean of 18 months (with a minimum of 9 months) after LVAD implantation to evaluate recurrent VTA, adverse events, and procedural outcomes. Secondary endpoints include right heart function/hemodynamics, healthcare utilization, and quality of life. CONCLUSION: The primary aim of this first-ever randomized trial is to assess the efficacy of intra-operative ablation during LVAD surgery in reducing VTA recurrence and improving clinical outcomes for patients with a history of VTA.


Subject(s)
Defibrillators, Implantable , Heart Failure , Heart-Assist Devices , Tachycardia, Ventricular , Humans , Heart-Assist Devices/adverse effects , Prospective Studies , Quality of Life , Risk Factors , Electrocardiography , Arrhythmias, Cardiac , Tachycardia, Ventricular/etiology , Treatment Outcome
12.
Artif Organs ; 47(8): 1242-1249, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36820756

ABSTRACT

BACKGROUND: There are limited data regarding racial disparities in outcomes after left ventricular assist device (LVAD) implantation. The purpose of this study was to compare clinical characteristics and the burden of readmissions by race among patients with LVAD. METHODS: The study population included 461 patients implanted with LVADs at the University of Rochester Medical Center, NY from May 2008 to March 2020. Patients were stratified by race as White patients (N = 396 [86%]) and Black patients (N = 65 [14%]). The Anderson-Gill recurrent regression analysis was used to assess the independent association between race and the total number of admissions after LVAD implant during an average follow-up of 2.45 ± 2.30 years. RESULTS: Black patients displayed significant differences in baseline clinical characteristics compared to White patients, including a younger age, a lower frequency of ischemic etiology, and a higher baseline serum creatinine. Black patients had a significantly higher burden of readmissions after LVAD implantation as compared with White patients 10 versus 7 (average number of hospitalizations per patient at 5 years of follow-up, respectively) translated into a significant 39% increased risk of recurrent readmissions after multivariate adjustment (Hazard ratio 1.39, 95% CI; 1.07-1.82, p 0.013). CONCLUSION: Black LVAD patients experience an increased burden of readmissions compared with White patients, after adjustment for baseline differences in demographics and clinical characteristics. Future studies should assess the underlying mechanisms for this increased risk including the effect of social determinants of health on the risk of readmissions in LVAD recipients.


Subject(s)
Heart Failure , Heart-Assist Devices , Patient Readmission , Race Factors , Humans , White , Black or African American , Male , Female , Adult , Middle Aged , Aged , Heart Failure/epidemiology , Retrospective Studies
13.
Eur Heart J ; 42(17): 1676-1684, 2021 05 01.
Article in English | MEDLINE | ID: mdl-33417692

ABSTRACT

AIMS: The benefit of prophylactic implantable cardioverter-defibrillator (ICD) is not uniform due to differences in the risk of life-threatening ventricular tachycardia (VT)/ventricular fibrillation (VF) and non-arrhythmic mortality. We aimed to develop an ICD benefit prediction score that integrates the competing risks. METHODS AND RESULTS: The study population comprised all 4531 patients enrolled in the MADIT trials. Best-subsets Fine and Gray regression analysis was used to develop prognostic models for VT (≥200 b.p.m.)/VF vs. non-arrhythmic mortality (defined as death without prior sustained VT/VF). Eight predictors of VT/VF (male, age < 75 years, prior non-sustained VT, heart rate > 75 b.p.m., systolic blood pressure < 140 mmHg, ejection fraction ≤ 25%, myocardial infarction, and atrialarrhythmia) and 7 predictors of non-arrhythmic mortality (age ≥ 75 years, diabetes mellitus, body mass index < 23 kg/m2, ejection fraction ≤ 25%, New York Heart Association ≥II, ICD vs. cardiac resynchronization therapy with defibrillator, and atrial arrhythmia) were identified. The two scores were combined to create three MADIT-ICD benefit groups. In the highest benefit group, the 3-year predicted risk of VT/VF was three-fold higher than the risk of non-arrhythmic mortality (20% vs. 7%, P < 0.001). In the intermediate benefit group, the difference in the corresponding predicted risks was attenuated (15% vs. 9%, P < 0.01). In the lowest benefit group, the 3-year predicted risk of VT/VF was similar to the risk of non-arrhythmic mortality (11% vs. 12%, P = 0.41). A personalized ICD benefit score was developed based on the distribution of the two competing risks scores in the study population (https://is.gd/madit). Internal and external validation confirmed model stability. CONCLUSIONS: We propose the novel MADIT-ICD benefit score that predicts the likelihood of prophylactic ICD benefit through personalized assessment of the risk of VT/VF weighed against the risk of non-arrhythmic mortality.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Tachycardia, Ventricular , Aged , Arrhythmias, Cardiac/therapy , Humans , Male , Risk Factors , Tachycardia, Ventricular/therapy , Ventricular Fibrillation/therapy
14.
Circulation ; 141(6): 429-439, 2020 02 11.
Article in English | MEDLINE | ID: mdl-31941373

ABSTRACT

BACKGROUND: Insight into type 5 long QT syndrome (LQT5) has been limited to case reports and small family series. Improved understanding of the clinical phenotype and genetic features associated with rare KCNE1 variants implicated in LQT5 was sought through an international multicenter collaboration. METHODS: Patients with either presumed autosomal dominant LQT5 (N = 229) or the recessive Type 2 Jervell and Lange-Nielsen syndrome (N = 19) were enrolled from 22 genetic arrhythmia clinics and 4 registries from 9 countries. KCNE1 variants were evaluated for ECG penetrance (defined as QTc >460 ms on presenting ECG) and genotype-phenotype segregation. Multivariable Cox regression was used to compare the associations between clinical and genetic variables with a composite primary outcome of definite arrhythmic events, including appropriate implantable cardioverter-defibrillator shocks, aborted cardiac arrest, and sudden cardiac death. RESULTS: A total of 32 distinct KCNE1 rare variants were identified in 89 probands and 140 genotype positive family members with presumed LQT5 and an additional 19 Type 2 Jervell and Lange-Nielsen syndrome patients. Among presumed LQT5 patients, the mean QTc on presenting ECG was significantly longer in probands (476.9±38.6 ms) compared with genotype positive family members (441.8±30.9 ms, P<0.001). ECG penetrance for heterozygous genotype positive family members was 20.7% (29/140). A definite arrhythmic event was experienced in 16.9% (15/89) of heterozygous probands in comparison with 1.4% (2/140) of family members (adjusted hazard ratio [HR] 11.6 [95% CI, 2.6-52.2]; P=0.001). Event incidence did not differ significantly for Type 2 Jervell and Lange-Nielsen syndrome patients relative to the overall heterozygous cohort (10.5% [2/19]; HR 1.7 [95% CI, 0.3-10.8], P=0.590). The cumulative prevalence of the 32 KCNE1 variants in the Genome Aggregation Database, which is a human database of exome and genome sequencing data from now over 140 000 individuals, was 238-fold greater than the anticipated prevalence of all LQT5 combined (0.238% vs 0.001%). CONCLUSIONS: The present study suggests that putative/confirmed loss-of-function KCNE1 variants predispose to QT prolongation, however, the low ECG penetrance observed suggests they do not manifest clinically in the majority of individuals, aligning with the mild phenotype observed for Type 2 Jervell and Lange-Nielsen syndrome patients.


Subject(s)
Long QT Syndrome , Penetrance , Potassium Channels, Voltage-Gated/genetics , Registries , Adolescent , Adult , Death, Sudden, Cardiac , Electric Countershock , Electrocardiography , Female , Heart Arrest/genetics , Heart Arrest/mortality , Heart Arrest/physiopathology , Heart Arrest/therapy , Humans , Long QT Syndrome/genetics , Long QT Syndrome/mortality , Long QT Syndrome/physiopathology , Long QT Syndrome/therapy , Male , Middle Aged
15.
Ann Noninvasive Electrocardiol ; 26(4): e12847, 2021 07.
Article in English | MEDLINE | ID: mdl-33772947

ABSTRACT

INTRODUCTION: Cardiac resynchronization therapy (CRT) may be pro-arrhythmic in patients with non-left bundle branch block (non-LBBB). We hypothesized that combined assessment of risk factors (RF) for ventricular tachyarrhythmias (VTAs) can be used to stratify non-LBBB patients for CRT implantation. METHODS: The study comprised 412 non-LBBB patients from MADIT-CRT randomized to CRT-D (n = 215) versus ICD only (n = 197). Best-subset regression analysis was performed to identify RF associated with increased VTA risk in CRT-D patients without LBBB. The primary end point was first occurrence of sustained VTA during follow-up. Secondary end points included VTA/death and appropriate shock. RESULTS: Four RFs were associated with increased VTA risk: blood urea nitrogen >25mg/dl, ejection fraction <20%, prior nonsustained VT, and female gender. Among CRT-D patients, 114 (53%) had no RF, while 101 (47%) had ≥1 RF. The 4-year cumulative probability of VTA was higher among those with ≥1 RF compared with those without RF (40% vs. 14%, p < .001). Multivariate analysis showed that in patients without RF, treatment with CRT-D was associated with a 61% reduction in VTA compared with ICD-only therapy (p = .002), whereas among patients with ≥1 RF, treatment with CRT-D was associated with a corresponding 73% (p = .025) risk increase. Consistent results were observed when the secondary end points of VTA/death and appropriate ICD shocks were assessed. CONCLUSION: Combined assessment of factors associated with increased risk for VTA can be used for improved selection of non-LBBB patients for CRT-D.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Tachycardia, Ventricular , Bundle-Branch Block/complications , Bundle-Branch Block/therapy , Electrocardiography , Female , Heart Failure/complications , Heart Failure/therapy , Humans , Risk Factors , Tachycardia, Ventricular/therapy , Treatment Outcome
16.
Eur Heart J ; 41(18): 1747-1756, 2020 05 07.
Article in English | MEDLINE | ID: mdl-31923316

ABSTRACT

AIMS: Our aim was to develop a machine learning (ML)-based risk stratification system to predict 1-, 2-, 3-, 4-, and 5-year all-cause mortality from pre-implant parameters of patients undergoing cardiac resynchronization therapy (CRT). METHODS AND RESULTS: Multiple ML models were trained on a retrospective database of 1510 patients undergoing CRT implantation to predict 1- to 5-year all-cause mortality. Thirty-three pre-implant clinical features were selected to train the models. The best performing model [SEMMELWEIS-CRT score (perSonalizEd assessMent of estiMatEd risk of mortaLity With machinE learnIng in patientS undergoing CRT implantation)], along with pre-existing scores (Seattle Heart Failure Model, VALID-CRT, EAARN, ScREEN, and CRT-score), was tested on an independent cohort of 158 patients. There were 805 (53%) deaths in the training cohort and 80 (51%) deaths in the test cohort during the 5-year follow-up period. Among the trained classifiers, random forest demonstrated the best performance. For the prediction of 1-, 2-, 3-, 4-, and 5-year mortality, the areas under the receiver operating characteristic curves of the SEMMELWEIS-CRT score were 0.768 (95% CI: 0.674-0.861; P < 0.001), 0.793 (95% CI: 0.718-0.867; P < 0.001), 0.785 (95% CI: 0.711-0.859; P < 0.001), 0.776 (95% CI: 0.703-0.849; P < 0.001), and 0.803 (95% CI: 0.733-0.872; P < 0.001), respectively. The discriminative ability of our model was superior to other evaluated scores. CONCLUSION: The SEMMELWEIS-CRT score (available at semmelweiscrtscore.com) exhibited good discriminative capabilities for the prediction of all-cause death in CRT patients and outperformed the already existing risk scores. By capturing the non-linear association of predictors, the utilization of ML approaches may facilitate optimal candidate selection and prognostication of patients undergoing CRT implantation.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Heart Failure/therapy , Humans , Machine Learning , Retrospective Studies , Risk Factors , Treatment Outcome
17.
Am Heart J ; 220: 59-67, 2020 02.
Article in English | MEDLINE | ID: mdl-31785550

ABSTRACT

BACKGROUND: Despite a higher prevalence of sudden cardiac death (SCD), black individuals are less likely than whites to have an implantable cardioverter defibrillator (ICD) implanted. Racial differences in ICD utilization is in part explained by higher refusal rates in black individuals. Decision support can assist with treatment-related uncertainty and prepare patients to make well-informed decisions. METHODS: The Videos to reduce racial disparities in ICD therapy Via Innovative Designs (VIVID) study will randomize 350 black individuals with a primary prevention indication for an ICD to a racially concordant/discordant video-based decision support tool or usual care. The composite primary outcome is (1) the decision for ICD placement in the combined video groups compared with usual care and (2) the decision for ICD placement in the racially concordant relative to discordant video group. Additional outcomes include knowledge of ICD therapy and SCD risk; decisional conflict; ICD receipt at 90 days; and a qualitative assessment of ICD decision making in acceptors, decliners, and those undecided. CONCLUSIONS: In addition to assessing the efficacy of decision support on ICD acceptance among black individuals, VIVID will provide insight into the role of racial concordance in medical decision making. Given the similarities in the root causes of racial/ethnic disparities in care across health disciplines, our approach and findings may be generalizable to decision making in other health care settings.


Subject(s)
Black People , Death, Sudden, Cardiac/prevention & control , Decision Support Techniques , Defibrillators, Implantable/statistics & numerical data , Healthcare Disparities/ethnology , Patient Education as Topic/methods , Adult , Black or African American , Audiovisual Aids , Death, Sudden, Cardiac/ethnology , Humans , Patient Compliance/ethnology , Prospective Studies , Treatment Refusal/ethnology , Treatment Refusal/statistics & numerical data , Uncertainty
18.
Am Heart J ; 223: 48-58, 2020 05.
Article in English | MEDLINE | ID: mdl-32163753

ABSTRACT

BACKGROUND: Although cardiac resynchronization therapy (CRT) is effective for some patients with heart failure and a reduced left ventricular ejection fraction (HFrEF), evidence gaps remain for key clinical and policy areas. The objective of the study was to review the data on the effects of CRT for patients with HFrEF receiving pharmacological therapy alone or pharmacological therapy and an implantable cardioverter-defibrillator (ICD) and then, informed by a diverse group of stakeholders, to identify evidence gaps, prioritize them, and develop a research plan. METHODS: Relevant studies were identified using PubMed and EMBASE and ongoing trials using clinicaltrials.gov. Forced-ranking prioritization method was applied by stakeholders to reach a consensus on the most important questions. Twenty-six stakeholders contributed to the expanded list of evidence gaps, including key investigators from existing randomized controlled trials and others representing different perspectives, including patients, the public, device manufacturers, and policymakers. RESULTS: Of the 18 top-tier evidence gaps, 8 were related to specific populations or subgroups of interest. Seven were related to the comparative effectiveness and safety of CRT interventions or comparators, and 3 were related to the association of CRT treatment with specific outcomes. The association of comorbidities with CRT effectiveness ranked highest, followed by questions about the effectiveness of CRT among patients with atrial fibrillation and the relationship between gender, QRS morphology and duration, and outcomes for patients either with CRT plus ICD or with ICD. CONCLUSIONS: Evidence gaps presented in this article highlight numerous, important clinical and policy questions for which there is inconclusive evidence on the role of CRT and provide a framework for future collaborative research.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure/therapy , Research/trends , Forecasting , Heart Failure/physiopathology , Humans , Stroke Volume
19.
J Cardiovasc Electrophysiol ; 31(5): 1099-1104, 2020 05.
Article in English | MEDLINE | ID: mdl-32107818

ABSTRACT

INTRODUCTION: We aimed to assess the predictors of new supraventricular tachycardia (SVT) and the association of new SVT with subsequent clinical outcomes among mild heart failure (HF) patients. METHODS AND RESULTS: The study population comprised patients enrolled in MADIT-CRT, after exclusion of patients with atrial arrhythmias before enrollment (N = 325). Multivariate analysis was used to identify predictors of new-onset SVT and the association of time-dependent development of SVT with subsequent ventricular tachyarrhythmic events (VTEs), HF-hospitalizations, and death. SVT burden was categorized into three groups based on the number of episodes per patient; (a) Low <10, (b) Intermediate ≥10 but <20, and (c) High ≥20. During mean follow up of 3.4 ± 1.1 years, 41(3%) subjects developed new SVT. African American race, diastolic blood pressure (DBP) >80 mmHg and prior non sustained ventricular arrhythmia were independent predictors for SVT. Multivariate analysis showed that the development of time-dependent SVT was associated with a >4-fold increased risk for VTEs (HR = 4.3; 95% CI: 1.6-11.7; P = .004) and with a >6-fold increased risk for all-cause mortality (HR = 6.5; 95% CI: 2.3-18.7; P < .001), but not with HF hospitalizations (HR = 2.2; 95% CI: 0.7-7.2; P = .17). Intermediate, and high SVT-burden were each independent risk factors for death when compared with Low burden (HR = 9.1; P = .03, and HR = 19.4; P < .001; respectively). CONCLUSIONS: In patients with mild HF, the development of new-onset SVT after device implantation is related to distinct baseline clinical and epidemiologic characteristics and is associated with a significant increase in subsequent adverse outcomes, including VTEs and death.


Subject(s)
Heart Failure/complications , Tachycardia, Supraventricular/etiology , Aged , Cardiac Resynchronization Therapy , Cardiac Resynchronization Therapy Devices , Defibrillators, Implantable , Electric Countershock/instrumentation , Female , Heart Failure/diagnosis , Heart Failure/mortality , Heart Failure/therapy , Humans , Male , Middle Aged , Risk Assessment , Risk Factors , Severity of Illness Index , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/mortality , Time Factors , Treatment Outcome
20.
Europace ; 22(9): 1384-1390, 2020 09 01.
Article in English | MEDLINE | ID: mdl-32875313

ABSTRACT

AIMS: Patients with impaired renal function were shown to have an attenuated benefit from implantable cardioverter-defibrillator. However, there are limited data on the competing risk of ventricular arrhythmia events and death by renal function in patients without severe disease. Therefore, we aimed to assess the competing risk of ventricular arrhythmia events and death by renal function. METHODS AND RESULTS: We analysed 1782 patients (99%) enrolled in Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) with glomerular filtration rate (GFR) data available. Cumulative incidence function curves were used to display the rate of ventricular tachycardia (VT), ventricular fibrillation (VF), and the competing risk of death without experiencing VT/VF. Multivariable Fine and Gray regression models and recurrent event analysis were performed. There were 355 (20%) patients with GFR < 52 and 1427 with GFR ≥ 52 (lowest quintile). The incidence of non-fatal VT/VF at 4 years was higher in patients with high GFR (26%) as compared to low GFR (16%), whereas rates of death without non-fatal VT/VF were 5% and 20% (P < 0.001). In Fine and Gray models, the low GFR group was 35% less likely to experience VT/VF compared to the high GFR [95% confidence interval (CI) 0.48-0.88, P = 0.005]. In contrast,death without experiencing VT/VF was 3.5-fold higher in the low GFR group (95% CI 2.38-5.12, P-value < 0.001). Recurrent event analysis consistently showed a lower risk of recurrent VT/VF, recurrent anti-tachycardia pacing only, and shock in the low GFR group. CONCLUSIONS: We show, in a competing risk model, a lower risk of VT/VF events and a higher risk of mortality without an arrhythmic event in patients with moderate renal dysfunction in MADIT-CRT. These findings can be used for improved selection of patients for defibrillator therapy among CRT candidates. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT00180271.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Kidney Diseases , Tachycardia, Ventricular , Arrhythmias, Cardiac/therapy , Heart Failure/diagnosis , Heart Failure/epidemiology , Heart Failure/therapy , Humans , Risk Assessment , Risk Factors , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/therapy , Treatment Outcome , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/epidemiology , Ventricular Fibrillation/therapy
SELECTION OF CITATIONS
SEARCH DETAIL