1.
Anal Chem ; 94(22): 7877-7884, 2022 06 07.
Article in English | MEDLINE | ID: mdl-35607711

ABSTRACT

Many chromatographers have observed that the operating pressure can dramatically change the chromatographic retention of solutes. Small molecules show observables changes, yet even more sizable effects are encountered with large biomolecules. With this work, we have explored the use of pressure as a method development parameter to alter the reversed-phase selectivity of peptide and protein separations. An apparatus for the facile manipulation of column pressure was assembled through a two-pump system and postcolumn flow restriction. The primary pump provided an eluent flow through the column, while the secondary pump provided a pressure-modulating flow at a tee junction after the column but ahead of a flow restrictor. Using this setup, we were able to quickly program various constant pressure changes and even pressure gradients. It was reconfirmed that pressure changes impact the retention of large molecules to a much greater degree than small molecules, making it especially interesting to consider the use of pressure to selectively separate solutes of different sizes. The addition of pressure to bring the column operating pressure beyond 500 bar was enough to change the elution order of insulin (a peptide hormone) and cytochrome C (a small serum protein). Moreover, with the proposed setup, it was possible to combine eluent and pressure gradients in the same analytical run. This advanced technique was applied to improve the separation of insulin from one of its forced degradation impurities. We have referred to this method as pressure-enhanced liquid chromatography and believe that it can offer unseen selectivity, starting with peptide and protein reversed-phase separations.


Subject(s)
Insulins , Proteins , Chromatography, High Pressure Liquid/methods , Chromatography, Liquid , Peptides , Pressure , Proteins/chemistry
2.
Anal Chem ; 94(7): 3360-3367, 2022 02 22.
Article in English | MEDLINE | ID: mdl-35143179

ABSTRACT

Certain biomolecules have proven to be difficult to analyze by liquid chromatography (LC), especially under certain chromatographic conditions. The separation of proteins in aqueous mobile phases is one such example because there is the potential for both hydrophobic and ionic secondary interactions to occur with chromatographic hardware to the detriment of peak recovery, peak shape, and the overall sensitivity of the LC analysis. To decrease non-specific adsorption and undesired secondary interactions between column hardware and biomolecules, we have developed and applied a new hydrophilically modified hybrid surface (h-HST) for size exclusion chromatography (SEC) and anion exchange (AEX) separations of proteins and nucleic acids. This surface incorporates additional oxygen and carbon atoms onto an ethylene bridge hybrid siloxane polymer. As a result, it exhibits reduced electrostatic properties and hydrophilicity that facilitates challenging aqueous separations. Flow injection tests with a phosphate buffer showed superior protein recovery from an h-HST frit when compared to unmodified ethylene-bridged hybrid HST, titanium, stainless steel, and PEEK frits. When applied to SEC of rituximab, ramucirumab, and trastuzumab emtansine with a 50 mM ammonium acetate buffer, this new hydrophilic chromatographic hardware yielded improved monomer and aggregate recovery, higher plate numbers, and more symmetrical peaks. AEX columns also benefited from h-HST hardware. An acidic mAb (eculizumab) showed improved recovery, more stable retention, and a sharper peak when eluted from an h-HST versus SS column. Moreover, AEX separations of intact mRNA samples (Cas9 and EPO mRNA) were improved, where it was seen that h-HST column hardware provided higher sensitivity and more repeatable peak areas from injection to injection. As such, there is significant potential in the use of h-HST chromatographic hardware to facilitate more robust and more sensitive analyses for a multitude of challenging separations and analytes.


Subject(s)
Chromatography, High Pressure Liquid , Chromatography, Gel , Chromatography, High Pressure Liquid/methods , Chromatography, Ion Exchange , Chromatography, Liquid/methods , Hydrophobic and Hydrophilic Interactions
3.
Anal Chem ; 93(3): 1277-1284, 2021 01 26.
Article in English | MEDLINE | ID: mdl-33332095

ABSTRACT

Due to the particular elution mechanism observed with large solutes (e.g., proteins) in liquid chromatography, column length has less impact in controlling their retention compared to small solutes. Moreover, long columns-in theory-just broaden the peaks of large solutes since a great part of the column only acts as void (extra) volume. Such a theory suggests that using very short columns should result in comparable separation quality versus using long columns and make it possible to perform faster (high-throughput) analyses. Therefore, the elution behavior of various therapeutic monoclonal antibodies and their fragments (25-150 kDa) has been investigated using modern instrumentation and column formats. The possibilities offered by narrow-bore columns packed with state-of-the-art 2.7 µm superficially porous particles with 5, 50, 100, and 150 mm lengths have been compared. In particular, the impact of gradient steepness and column length on separation efficiency was evaluated. Using 5 mm × 2.1 mm columns, it has become possible to separate antibody fragments and antibody-drug conjugate species in less than 30 s. Such fast methods can be very useful for high-throughput screening purposes in biopharmaceutical industries.


Subject(s)
Antibodies, Monoclonal/isolation & purification , Immunoconjugates/isolation & purification , Antibodies, Monoclonal/chemistry , Chromatography, High Pressure Liquid , Humans , Immunoconjugates/chemistry , Software
4.
Anal Chem ; 93(14): 5773-5781, 2021 04 13.
Article in English | MEDLINE | ID: mdl-33798331

ABSTRACT

Interactions of analytes with metal surfaces in high-performance liquid chromatography (HPLC) instruments and columns have been reported to cause deleterious effects ranging from peak tailing to a complete loss of the analyte signal. These effects are due to the adsorption of certain analytes on the metal oxide layer on the surface of the metal components. We have developed a novel surface modification technology and applied it to the metal components in ultra-HPLC (UHPLC) instruments and columns to mitigate these interactions. A hybrid organic-inorganic surface, based on an ethylene-bridged siloxane chemistry, was developed for use with reversed-phase and hydrophilic interaction chromatography. We have characterized the performance of UHPLC instruments and columns that incorporate this surface technology and compared the results with those obtained using their conventional counterparts. We demonstrate improved performance when using the hybrid surface technology for separations of nucleotides, a phosphopeptide, and an oligonucleotide. The hybrid surface technology was found to result in higher and more consistent analyte peak areas and improved peak shape, particularly when using low analyte mass loads and acidic mobile phases. Reduced abundances of iron adducts in the mass spectrum of a peptide were also observed when using UHPLC systems and columns that incorporate hybrid surface technology. These results suggest that this technology will be particularly beneficial in UHPLC/mass spectrometry investigations of metal-sensitive analytes.

5.
Anal Chem ; 93(3): 1285-1293, 2021 01 26.
Article in English | MEDLINE | ID: mdl-33305942

ABSTRACT

In the first part of the series, it was demonstrated that very fast (<30 s) separations of therapeutic protein species are feasible using ultra-short (5 × 2.1 mm) columns. In the second part, our purpose was to find the appropriate column length; therefore, a systematic study was performed using various custom-made prototype reversed-phase liquid chromatography (RPLC) columns ranging from 2 to 50 mm lengths. It was found that on a low dispersion ultrahigh-pressure liquid chromatography instrument, columns between 10 and 20 mm were most effective when made with 2.1 mm i.d. tubing. However, with the same LC instrument, 3 mm i.d. columns as short as ∼5 to 10 mm could be effectively used. In both cases, it has been found to be best to keep injection volumes below 0.6 µL, which presents a potential limit to further decreasing column length, given the current capabilities of autosampler instrumentation. The additional volume of the column hardware outside of the packed bed (extra-bed volume) of very small columns is also a limiting factor to decrease the column length. For columns shorter than 10 mm, columns' extra-bed volume was seen to make considerable contributions to band broadening. However, the use of ultra-short columns seemed to be a very useful approach for RPLC of large proteins (>25 kDa) and could also work well for ∼12 kDa as the lowest limit of molecular mass. In summary, a renewed interest in the use of ultra-short columns is warranted, and additional method development will be to the benefit of the biopharmaceutical industry as there is an ever-increasing demand for faster, yet accurate assays (e.g., high-throughput screening) of proteins.


Subject(s)
Antibodies, Monoclonal/isolation & purification , Cytochromes c/isolation & purification , Antibodies, Monoclonal/chemistry , Chromatography, Liquid , Chromatography, Reverse-Phase , Cytochromes c/chemistry , Humans , Software
6.
Anal Chem ; 87(20): 10283-91, 2015 Oct 20.
Article in English | MEDLINE | ID: mdl-26266576

ABSTRACT

The enormous dynamic range of proteinaceous species present in protein biotherapeutics poses a significant challenge for current mass spectrometry (MS)-based methods to detect low-abundance HCP impurities. Previously, an HCP assay based on two-dimensional chromatographic separation (high pH/low pH) coupled to high-resolution quadrupole time-of-flight (QTOF) mass spectrometry and developed in the author's laboratory has been shown to achieve a detection limit of about 50 ppm (parts per milion) for the identification and quantification of HCPs present in monoclonal antibodies following Protein A purification.1 To improve the HCP detection limit we have explored the utility of several new analytical techniques for HCP analysis and thereby developed an improved liquid chromatography-mass spectrometry (LC-MS) methodology for enhanced detection of HCPs. The new method includes (1) the use of a new charge-surface-modified (CSH) C18 stationary phase to mitigate the challenges of column saturation, peak tailing, and distortion that are commonly observed in the HCP analysis; (2) the incorporation of traveling-wave ion mobility (TWIM) separation of coeluting peptide precursors, and (3) the improvement of fragmentation efficiency of low-abundance HCP peptides by correlating the collision energy used for precursor fragmentation with their mobility drift time. As a result of these improvements, the detection limit of the new methodology was greatly improved, and HCPs present at a concentration as low as 1 ppm (1 ng HCP/mg mAb) were successfully identified and quantified. The newly developed method was applied to analyze two high-purity mAbs (NIST mAb and Infliximab) expressed in a murine cell line. For both samples, low-abundance HCPs (down to 1 ppm) were confidently identified, and the identities of the HCPs were further confirmed by targeted MS/MS experiments. In addition, the performance of the assay was evaluated by an interlaboratory study in which three independent laboratories performed the same HCP assay on the mAb sample. The reproducibility of this assay is also discussed.


Subject(s)
Antibodies, Monoclonal/chemistry , Drug Contamination , Mass Spectrometry , Proteins/analysis , Animals , Chromatography, Liquid , Mice
7.
Anal Chem ; 87(10): 5401-9, 2015.
Article in English | MEDLINE | ID: mdl-25927596

ABSTRACT

N-glycosylation of proteins is now routinely characterized and monitored because of its significance to the detection of disease states and the manufacturing of biopharmaceuticals. At the same time, hydrophilic interaction chromatography (HILIC) has emerged as a powerful technology for N-glycan profiling. Sample preparation techniques for N-glycan HILIC analyses have however tended to be laborious or require compromises in sensitivity. To address these shortcomings, we have developed an N-glycan labeling reagent that provides enhanced fluorescence response and MS sensitivity for glycan detection and have also simplified the process of preparing a sample for analysis. The developed labeling reagent rapidly reacts with glycosylamines upon their release from glycoproteins. Within a 5 min reaction, enzymatically released N-glycans are labeled with this reagent comprised of an NHS-carbamate reactive group, a quinoline fluorophore, and a tertiary amine for enhancing ESI+ MS ionization. To further expedite the released N-glycan sample preparation, rapid tagging has been integrated with a fast PNGase F deglycosylation procedure that achieves complete deglycosylation of a diverse set of glycoproteins in approximately 10 min. Moreover, a technique for HILIC-SPE of the labeled glycans has been developed to provide quantitative recovery and facilitate immediate HILIC analysis of the prepared samples. The described approach makes it possible to quickly prepare N-glycan samples and to incorporate the use of a fluorescence and MS sensitivity enhancing labeling reagent. In demonstration of these new capabilities, we have combined the developed sample preparation techniques with UHPLC HILIC chromatography and high sensitivity mass spectrometry to thoroughly detail the N-glycan profile of a monoclonal antibody.


Subject(s)
Analytic Sample Preparation Methods/methods , Fluorescent Dyes/chemistry , Hydrophobic and Hydrophilic Interactions , Polysaccharides/analysis , Polysaccharides/chemistry , Animals , Antibodies, Monoclonal/chemistry , Chromatography, Liquid , Glycoproteins/chemistry , Glycosylation , Humans , Immunoglobulin G , Indicators and Reagents/chemistry , Mice , Models, Molecular , Protein Conformation , Spectrometry, Fluorescence , Spectrometry, Mass, Electrospray Ionization , Time Factors
8.
Mol Cell Proteomics ; 11(12): 1965-76, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23033476

ABSTRACT

Ribosomal protein S1 has been shown to be a significant effector of prokaryotic translation. The protein is in fact capable of efficiently initiating translation, regardless of the presence of a Shine-Dalgarno sequence in mRNA. Structural insights into this process have remained elusive, as S1 is recalcitrant to traditional techniques of structural analysis, such as x-ray crystallography. Through the application of protein cross-linking and high resolution mass spectrometry, we have detailed the ribosomal binding site of S1 and have observed evidence of its dynamics. Our results support a previous hypothesis that S1 acts as the mRNA catching arm of the prokaryotic ribosome. We also demonstrate that in solution the major domains of the 30S subunit are remarkably flexible, capable of moving 30-50Å with respect to one another.


Subject(s)
Escherichia coli Proteins/analysis , Escherichia coli Proteins/metabolism , Peptide Chain Initiation, Translational , Ribosomal Proteins/analysis , Ribosomal Proteins/metabolism , Ribosome Subunits, Small, Bacterial/ultrastructure , Binding Sites , Crystallography, X-Ray , Escherichia coli/genetics , Escherichia coli/metabolism , Mass Spectrometry , Nucleic Acid Conformation , Protein Biosynthesis , RNA, Messenger , Ribosome Subunits, Small, Bacterial/metabolism
9.
Anal Chem ; 85(14): 6936-44, 2013 Jul 16.
Article in English | MEDLINE | ID: mdl-23772755

ABSTRACT

Ionic analytes, such as peptides, can be challenging to separate by reverse-phase chromatography with optimal efficiency. They tend, for instance, to exhibit poor peak shapes, particularly when eluted with mobile phases preferred for electrospray ionization mass spectrometry. We demonstrate that a novel charged-surface C18 stationary phase alleviates some of the challenges associated with reverse-phase peptide separations. This column chemistry, known as CSH (charged-surface hybrid) C18, improves upon an already robust organosilica hybrid stationary phase, BEH (ethylene-bridged hybrid) C18. Based on separations of a nine-peptide standard, CSH C18 was found to exhibit improved loadability, greater peak capacities, and unique selectivity compared to BEH C18. Its performance was also seen to be significantly less dependent on TFA-ion pairing, making it ideal for MS applications where high sensitivity is desired. These performance advantages were evaluated through application to peptide mapping, wherein CSH C18 was found to aid the development of a high-resolution, high-sensitivity LC-UV-MS peptide mapping method for the therapeutic antibody, trastuzumab. From these results, the use of a C18 stationary phase with a charged surface, such as CSH C18, holds significant promise for facilitating challenging peptide analyses.


Subject(s)
Mass Spectrometry/methods , Peptide Fragments/analysis , Peptide Mapping/methods , Amino Acid Sequence , Molecular Sequence Data , Peptide Fragments/genetics
10.
J Chromatogr A ; 1692: 463872, 2023 Mar 15.
Article in English | MEDLINE | ID: mdl-36804800

ABSTRACT

Upon recently studying the use of pressure gradients during liquid chromatography (LC), it was noted that pressure differentials across a column can have a significant impact on peak shape, not just retention as has been noted several times before. Theoretical models and thought experiments were performed here to more carefully study these effects. Two situations have been elucidated. The first is one that reflects a protein reversed phase separation wherein solute retention increases with pressure. In this condition, it has been found that a positive pressure gradient will result in band broadening while a negative pressure gradient will help yield sharper peaks. The second case that has come to be better appreciated is when solute retention decreases with pressure, which can occur in protein ion exchange (IEX) and hydrophobic interaction chromatography (HIC). In this situation, a positive pressure gradient will conversely result in peak sharpening, and a negative pressure gradient will introduce band broadening. These observations have facilitated making new fundamental understandings on pressurized separations which has in turn made it possible to begin envisioning new ways of and reasons for applying pressure enhanced LC methods.


Subject(s)
Models, Theoretical , Proteins , Chromatography, Liquid/methods , Chromatography, High Pressure Liquid/methods
11.
Article in English | MEDLINE | ID: mdl-36516651

ABSTRACT

In top-down proteomics experiments, intact protein ions are subjected to gas-phase fragmentation for MS analysis without prior digestion. This approach is used to characterize post-translational modifications and clipped forms of proteins, avoids several "inference" problems associated with bottom-up proteomics, and is well suited to the study of proteoforms. In the past decade, top-down proteomics has progressed rapidly, taking advantage of MS instrumentation improvements and the efforts of pioneering groups working to improve sample handling and data processing. The potential of this technology has been established through its successful use in a number of important biological studies. However, many challenges remain to be addressed like improving protein separation capabilities such that it might become possible to expand the dynamic range of whole proteome analysis, address co-elution and convoluted mass spectral data, and aid final data processing from peak identification to quantification. In this study, we investigated the use of a wide-pore silica-based superficially porous media with a high coverage phenyl bonding, commercially packed into customized capillary columns for the purpose of top-down proteomics. Protein samples of increasing complexity were tested, namely subunit digests of a monoclonal antibody, components of purified histones and proteins extracted from eukaryotic ribosomes. High quality mass spectra were obtained from only 100 ng of protein sample while using difluoroacetic acid as an ion pairing agent to improve peak shape and chromatographic resolution. A peak width at half height of about 15 s for a 45 min gradient time was observed on a complex mixture giving an estimated peak capacity close to 100. Most importantly, efficient separations were obtained for highly diverse proteins and there was no need to make method specific adjustments, suggesting this is a highly versatile and easy-to-use setup for top-down proteomics.


Subject(s)
Proteome , Proteomics , Proteomics/methods , Porosity , Chromatography, Liquid , Mass Spectrometry , Proteome/analysis
12.
Anal Chem ; 84(21): 9355-61, 2012 Nov 06.
Article in English | MEDLINE | ID: mdl-23020143

ABSTRACT

Thioimidates have emerged as reagents for probing the protein structure, folding, and interactions under physiological conditions. The same properties that give thioimidates biological relevance make these molecules ideal candidates for use in vivo. Through labeling of ribosomal proteins, we have quantified the in vivo and in vitro reactivity of two thioimidates: S-methylthioacetimidate (SMTA) and a novel, charge-carrying analogue, S-sulfethylthioacetimidate (SSETA). In vitro experiments demonstrate that both amidinating reagents can probe the protein structure. Under comparable in vivo conditions, SMTA is found to be membrane-permeable while SSETA is not. The use of mass spectrometry with permeant and impermeant thioimidates promises insights into the membrane topology and protein structure in the native environment.


Subject(s)
Imidoesters/chemistry , Ribosomal Proteins/chemistry , Staining and Labeling/methods , Cell Membrane Permeability , Escherichia coli K12/cytology , Imidoesters/chemical synthesis , Imidoesters/metabolism
13.
Article in English | MEDLINE | ID: mdl-35091294

ABSTRACT

Acidic N-linked glycan content is often associated with a protein drug's stability, efficacy and immune response. It has often been a challenge to analyze these types of glycans, including those that are differentiated by the incorporation of N-acetyl (NANA) and N-glycolyl neuraminic acid (NGNA) residues. In this study, a strategy for rapid N-glycan profiling by mixed mode chromatography is proposed as a complement to established HILIC methodologies. Hybrid silica chromatographic surfaces are used to improve recoveries during a column's initial use and to eliminate the need for column conditioning. In addition, the loss of labeled acidic glycans, especially phosphorylated glycan species, during SPE purification is addressed through the use of a citrate containing eluent. Yields for both singly and doubly phosphorylated glycan species are markedly improved. Combined with a mixed mode anion exchange reversed phase separation, these advances afford a class separation of glycans derivatized with labels designed to enhance positive ion mode MS detection. These labeled glycan species are separated according to their charge and with an added level of resolution imparted by the reversed phase retention mechanism. The separation technique itself can be accomplished with a low ionic strength gradient running from 0 to 22 mM ammonium formate such that high sensitivity detection can be achieved by both fluorescence and mass spectrometry. Using analytical scale chromatography, features in an N-glycan profile were easily interrogated to well below a 0.1% relative abundance. As such, it became possible to characterize N-glycans from recombinant beta glucuronidase and to quickly identify a number of unique phosphorylated glycan species.


Subject(s)
Chromatography, Liquid/methods , Mass Spectrometry/methods , Polysaccharides/chemistry , Molecular Structure , Sensitivity and Specificity
14.
J Chromatogr A ; 1677: 463324, 2022 Aug 16.
Article in English | MEDLINE | ID: mdl-35858489

ABSTRACT

As interest in oligonucleotide (ON) therapeutics is increasing, there is a need to develop suitable analytical methods able to properly analyze those molecules. However, an issue exists in the adsorption of ONs on different parts of the instrumentation during their analysis. The goal of the present paper was to comprehensively evaluate various types of bioinert materials used in ion-pairing reversed-phase (IP-RPLC) and hydrophilic interaction chromatography (HILIC) to mitigate this issue for 15- to 100-mer DNA and RNA oligonucleotides. The whole sample flow path was considered under both conditions, including chromatographic columns, ultra-high-performance liquid chromatography (UHPLC) system, and ultraviolet (UV) flow cell. It was found that a negligible amount of non-specific adsorption might be attributable to the chromatographic instrumentation. However, the flow cell of a detector should be carefully subjected to sample-based conditioning, as the material used in the UV flow cell was found to significantly impact the peak shapes of the largest ONs (60- to 100-mer). Most importantly, we found that the choice of column hardware had the most significant impact on the extent of non-specific adsorption. Depending on the material used for the column walls and frits, adsorption can be more or less pronounced. It was proved that any type of bioinert RPLC/HILIC column hardware offered some clear benefits in terms of adsorption in comparison to their stainless-steel counterparts. Finally, the evaluation of a large set of ONs was performed, including a DNA duplex and DNA or RNA ONs having different base composition, furanose sugar, and modifications occurring at the phosphate linkage or at the sugar moiety. This work represents an important advance in understanding the overall ON adsorption, and it helps to define the best combination of materials when analyzing a wide range of unmodified and modified 20-mer DNA and RNA ONs.


Subject(s)
Oligonucleotides , RNA , Adsorption , Chromatography, Reverse-Phase/methods , DNA , Hydrophobic and Hydrophilic Interactions , Oligonucleotides/analysis , Sugars
15.
J Chromatogr A ; 1666: 462855, 2022 Mar 15.
Article in English | MEDLINE | ID: mdl-35144106

ABSTRACT

It is critical to the success of any chromatography-based assay that the performance of the LC instrument be checked for its readiness and ability to perform the intended analysis. This includes gaging the suitability of a system to fulfill the purpose of different types of methods. One type of analysis that requires special consideration is the analysis of compounds which are prone to a particular form of non-specific binding, namely metal adsorption, where analytes interact and potentially adsorb to metal contained within the chromatographic flow path. For an analysis of compounds which are susceptible to metal adsorption, ideally a system suitability test would be performed to ensure there will not be any sample loss or detrimental peak shape effects resulting from potential analyte-to-metal interactions. To help chromatographers assess system inertness concerns like this, we have developed a method of testing LC systems for metal interactions using adenosine 5'-(α,ß-methylene)diphosphate (AMPcP). This nucleotide analog has been confirmed to have a propensity to adsorb to titanium and stainless-steel frits and is resistant to hydrolysis and stable to long-term storage and repeat use (as is befitting of any reagent proposed for system suitability testing). AMPcP has been used in a flow injection test (no column in-line) to monitor for losses in recovery and peak shape perturbations that can potentially be present in any chromatography system manufactured with one or more metal based components. In this approach, sequential injections of AMPcP were made without a column and various peak attributes were monitored and ultimately correlated to the amount of metal surface area in the flow path. The ability of this method to discriminate between inert chromatographic surfaces versus exposed metal surfaces was verified by comparing peak areas, peak shapes, and injection repeatability for AMPcP using a UHPLC equipped with MP35N metal alloy components versus an equivalent UHPLC equipped with an ethylene bridged hybrid organic-inorganic surface (or so-called hybrid surface technology). Injections of caffeine were also explored to establish a negative control for this system suitability measurement. Caffeine does not interact with metal surfaces and can therefore give an instrument specific representation of peak shape and dispersion as well as an indication of overall mechanical system performance. Additionally, replicate injections of AMPcP and caffeine onto a UHPLC partially configured with hybrid surface technology (HST) readily identified exposed metal surfaces through an increased peak area relative standard deviation as well as a reduction in absolute recovery. Finally, a novel visualization tool was developed to provide an alternative method of determining system inertness without having to perform chromatographic calculations but instead a graphical peak shape comparison between a negative control, caffeine, and the metal sensitive AMPcP test probe.


Subject(s)
Metals , Stainless Steel , Adsorption , Chromatography, High Pressure Liquid/methods , Chromatography, Liquid/methods , Metals/chemistry , Stainless Steel/chemistry
16.
Nat Commun ; 13(1): 1891, 2022 04 07.
Article in English | MEDLINE | ID: mdl-35393402

ABSTRACT

The SARS-CoV-2 3CL protease is a critical drug target for small molecule COVID-19 therapy, given its likely druggability and essentiality in the viral maturation and replication cycle. Based on the conservation of 3CL protease substrate binding pockets across coronaviruses and using screening, we identified four structurally distinct lead compounds that inhibit SARS-CoV-2 3CL protease. After evaluation of their binding specificity, cellular antiviral potency, metabolic stability, and water solubility, we prioritized the GC376 scaffold as being optimal for optimization. We identified multiple drug-like compounds with <10 nM potency for inhibiting SARS-CoV-2 3CL and the ability to block SARS-CoV-2 replication in human cells, obtained co-crystal structures of the 3CL protease in complex with these compounds, and determined that they have pan-coronavirus activity. We selected one compound, termed coronastat, as an optimized lead and characterized it in pharmacokinetic and safety studies in vivo. Coronastat represents a new candidate for a small molecule protease inhibitor for the treatment of SARS-CoV-2 infection for eliminating pandemics involving coronaviruses.


Subject(s)
Antiviral Agents , COVID-19 Drug Treatment , Coronavirus 3C Proteases , Protease Inhibitors , Antiviral Agents/chemistry , Antiviral Agents/therapeutic use , Coronavirus 3C Proteases/antagonists & inhibitors , Humans , Molecular Docking Simulation , Pandemics , Protease Inhibitors/chemistry , Protease Inhibitors/pharmacology , Protease Inhibitors/therapeutic use , SARS-CoV-2
17.
J Proteome Res ; 10(8): 3604-16, 2011 Aug 05.
Article in English | MEDLINE | ID: mdl-21618984

ABSTRACT

The structure of the Escherichia coli ribosome, a 2.5 MDa ribonucleoprotein complex containing more than 50 proteins, was probed using the novel amidinating cross-linker diethyl suberthioimidate (DEST) and mass spectrometry. Peptide cross-links derived from this complex structure were identified at high confidence (FDR 0.8%) from precursor mass measurements and collision-induced dissociation (CID) fragmentation spectra. The acquired cross-linking data were found to be in excellent agreement with the crystal structure of the E. coli ribosome. DEST cross-links are particularly amenable to strong cation exchange (SCX) chromatography, facilitating a large-scale analysis. SCX enrichment and fractionation were shown to increase the number of cross-link spectra matches in our analysis 10-fold. Evidence is presented that these techniques can be used to study complex interactomes.


Subject(s)
Escherichia coli/chemistry , Mass Spectrometry/methods , Ribosomes/chemistry , Cation Exchange Resins , Chromatography, Ion Exchange , Hydrolysis , Models, Molecular , Spectrometry, Mass, Electrospray Ionization , Tandem Mass Spectrometry
18.
Anal Chem ; 83(23): 9092-9, 2011 Dec 01.
Article in English | MEDLINE | ID: mdl-22007758

ABSTRACT

Selective chemical modification of protein side chains coupled with mass spectrometry is often most informative when used to compare residue-specific reactivities in a number of functional states or macromolecular complexes. Herein, we develop ratiometric pulse-chase amidination mass spectrometry (rPAm-MS) as a site-specific probe of lysine reactivities at equilibrium using the Cu(I)-sensing repressor CsoR from Bacillus subtilis as a model system. CsoR in various allosteric states was reacted with S-methyl thioacetimidate (SMTA) for pulse time, t, and chased with excess of S-methyl thiopropionimidate (SMTP) (Δ = 14 amu), quenched and digested with chymotrypsin or Glu-C protease, and peptides were quantified by high-resolution matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry and/or liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). We show that the reactivities of individual lysines from peptides containing up to three Lys residues are readily quantified using this method. New insights into operator DNA binding and the Cu(I)-mediated structural transition in the tetrameric copper sensor CsoR are also obtained.


Subject(s)
Amides/chemistry , Bacterial Proteins/metabolism , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization , Bacillus subtilis/metabolism , Chromatography, High Pressure Liquid , Chymotrypsin/metabolism , Copper/chemistry , Kinetics , Lysine/chemistry , Peptides/analysis , Serine Endopeptidases/metabolism
19.
J Chromatogr A ; 1635: 461743, 2021 Jan 04.
Article in English | MEDLINE | ID: mdl-33260022

ABSTRACT

In the present work, we describe the fundamental and practical advantages of a new strategy to improve the resolution of very closely eluting peaks within therapeutic protein samples. This approach involves the use of multiple isocratic steps, together with the addition of a steep negative gradient segment (with a decrease in mobile phase strength) to "park" a slightly more retained peak somewhere along the column (at a given migration distance), while a slightly less retained compound can be eluted. First, some model calculations were performed to highlight the potential of this innovative approach. For this purpose, the retention parameters (logk0 and S) for two case studies were considered, namely the analysis of a mixture of two therapeutic mAbs (simple to resolve sample) and separation of a therapeutic mAb from its main variant (challenging to resolve sample). The results confirm that the insertion of a negative segment into a multi-isocratic elution program can be a good tool to improve selectivity between critical peak pairs. However, it is also important to keep in mind that this approach only works with large solutes, which more or less follow an "on-off" type elution behavior. Two real applications were successfully developed to illustrate the practical advantage of this new approach, including the separation of a therapeutic mAb from its main variant possessing very close elution behavior, and the separation of a carrier protein from an intact mAb as might be encountered in a quantitative bioanalysis assay. These two examples demonstrate that improved selectivity can be achieved for protein RPLC through the inclusion of a negative gradient slope that selectively bifurcates the elution of two or more peaks of interest.


Subject(s)
Chemistry, Pharmaceutical/methods , Proteins/isolation & purification , Antibodies, Monoclonal/isolation & purification , Humans , Indicators and Reagents , Solutions
20.
Article in English | MEDLINE | ID: mdl-33866109

ABSTRACT

Quantification of proteins in biofluids has largely involved either traditional ligand binding assays or "bottom-up" mass spectrometry. Recently, top-down mass spectrometry using reversed-phase liquid chromatography (RPLC) paired with high-resolution mass spectrometry (HRMS) has emerged as a promising technique, due to the potential of better identification of post-translational modifications (PTMs), lack of downstream interferences, and less time-consuming sample preparation and analysis times. However, it can be difficult with this approach to robustly obtain high-fidelity MS data, especially when pushing for low limits of detection. To address these issues, we developed a chromatographic device with an optimized form factor and stationary phase to improve protein recovery, while reducing run times. We have observed that by using this device, it is possible to achieve attomole quantitation of mAbs without the addition of carrier proteins and with over three-fold higher throughput than columns employed in previous studies. Moreover, we have devised a novel affinity capture method, based on repurposing a unique aptamer ligand that can give 93% recovery of mAb using only a 2 h incubation. When hyphenated together, these two technologies greatly improve the ability to analyze proteins in complex matrices.