Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
BMC Anesthesiol ; 22(1): 211, 2022 07 08.
Article in English | MEDLINE | ID: mdl-35804321

ABSTRACT

BACKGROUND: A mismatch between oxygen delivery (DO2) and consumption (VO2) is associated with increased perioperative morbidity and mortality. Hyperlactatemia is often used as an early screening tool, but this non-continuous measurement requires intermittent arterial line sampling. Having a non-invasive tool to rapidly detect inadequate DO2 is of great clinical relevance. The respiratory exchange ratio (RER) can be easily measured in all intubated patients and has been shown to predict postoperative complications. We therefore aimed to assess the discriminative ability of the RER to detect an inadequate DO2 as reflected by hyperlactatemia in patients having intermediate-to-high risk abdominal surgery. METHODS: This historical cohort study included all consecutive patients who underwent intermediate-to-high risk surgery from January 1st, 2014, to April 30th, 2019 except those who did not have RER and/or arterial lactate measured. Blood lactate levels were measured routinely at the beginning and end of surgery and RER was calculated at the same moment as the blood gas sampling. The present study tested the hypothesis that RER measured at the end of surgery could detect hyperlactatemia at that time. A receiver operating characteristic (ROC) curve was constructed to assess if RER calculated at the end of the surgery could detect hyperlactatemia. The chosen RER threshold corresponded to the highest value of the sum of the specificity and the sensitivity (Youden Index). RESULTS: Among the 996 patients available in our study cohort, 941 were included and analyzed. The area under the ROC curve was 0.73 (95% CI: 0.70 to 0.76; p < 0.001), with a RER threshold of 0.75, allowing to discriminate a lactate > 1.5 mmol/L with a sensitivity of 87.5% and a specificity of 49.5%. CONCLUSION: In mechanically ventilated patients undergoing intermediate to high-risk abdominal surgery, the RER had moderate discriminative abilities to detect hyperlactatemia. Increased values should prompt clinicians to investigate for the presence of hyperlactatemia and treat any potential causes of DO2/VO2 mismatch as suggested by the subsequent presence of hyperlactatemia.


Subject(s)
Hyperlactatemia , Cohort Studies , Humans , Lactic Acid , Postoperative Complications/diagnosis
2.
BMC Anesthesiol ; 22(1): 300, 2022 09 21.
Article in English | MEDLINE | ID: mdl-36131247

ABSTRACT

BACKGROUND: In patients with end stage liver disease (ESLD) scheduled for liver transplantation (LT), an intraoperative incidental finding of elevated mean pulmonary arterial pressure (mPAP) may be observed. Its association with patient outcome has not been evaluated. We aimed to estimate the effects of an incidental finding of a mPAP > 20 mmHg during LT on the incidence of pulmonary complications. METHODS: We examined all patients who underwent a LT at Paul-Brousse hospital between January 1,2015 and December 31,2020. Those who received: a LT due to acute liver failure, a combined transplantation, or a retransplantation were excluded, as well as patients for whom known porto-pulmonary hypertension was treated before the LT or patients who underwent a LT for other etiologies than ESLD. Using right sided pulmonary artery catheterization measurements made following anesthesia induction, the study cohort was divided into two groups using a mPAP cutoff of 20 mmHg. The primary outcome was a composite of pulmonary complications. Univariate and multivariable logistic regression analyses were performed to identify variables associated with the primary outcome. Sensitivity analyses of multivariable models were also conducted with other mPAP cutoffs (mPAP ≥ 25 mmHg and ≥ 35 mmHg) and even with mPAP as a continuous variable. RESULTS: Of 942 patients who underwent a LT, 659 met our inclusion criteria. Among them, 446 patients (67.7%) presented with an elevated mPAP (mPAP of 26.4 ± 5.9 mmHg). When adjusted for confounding factors, an elevated mPAP was not associated with a higher risk of pulmonary complications (adjusted OR: 1.16; 95%CI 0.8-1.7), nor with 90 days-mortality or any other complications. In our sensitivity analyses, we observed a lower prevalence of elevated mPAP when increasing thresholds (235 patients (35.7%) had an elevated mPAP when defined as ≥ 25 mmHg and 41 patients (6.2%) had an elevated mPAP when defined as ≥ 35 mmHg). We did not observe consistent association between a mPAP ≥ 25 mmHg or a mPAP ≥ 35 mmHg and our outcomes. CONCLUSION: Incidental finding of elevated mPAP was highly prevalent during LT, but it was not associated with a higher risk of postoperative complications.


Subject(s)
End Stage Liver Disease , Hypertension, Pulmonary , Liver Transplantation , Arterial Pressure , End Stage Liver Disease/complications , Humans , Hypertension, Pulmonary/complications , Hypertension, Pulmonary/epidemiology , Incidental Findings , Liver Transplantation/adverse effects , Postoperative Complications/diagnosis , Postoperative Complications/epidemiology , Pulmonary Artery , Retrospective Studies
3.
BMC Anesthesiol ; 22(1): 405, 2022 12 28.
Article in English | MEDLINE | ID: mdl-36577954

ABSTRACT

BACKGROUND: During surgery, any mismatch between oxygen delivery (DO2) and consumption (VO2) can promote the development of postoperative complications. The respiratory exchange ratio (RER), defined as the ratio of carbon dioxide (CO2) production (VCO2) to VO2, may be a useful noninvasive tool for detecting inadequate DO2. The primary objective of this study was to test the hypothesis that RER measured during liver transplantation may predict postoperative morbidity. Secondary objectives were to assess the ability of other variables used to assess the DO2/VO2 relationship, including arterial lactate, mixed venous oxygen saturation, and veno-arterial difference in the partial pressure of carbon dioxide (VAPCO2gap), to predict postoperative complications. METHODS: This retrospective study included consecutive adult patients who underwent liver transplantation for end stage liver disease from June 27th, 2020, to September 5th, 2021. Patients with acute liver failure were excluded. All patients were routinely equipped with a pulmonary artery catheter. The primary analysis was a receiver operating characteristic (ROC) curve constructed to investigate the discriminative ability of the mean RER measured during surgery to predict postoperative complications. RER was calculated at five standardized time points during the surgery, at the same time as measurement of blood lactate levels and arterial and mixed venous blood gases, which were compared as a secondary analysis. RESULTS: Of the 115 patients included, 57 developed at least one postoperative complication. The mean RER (median [25-75] percentiles) during surgery was significantly higher in patients with complications than in those without (1.04[0.96-1.12] vs 0.88[0.84-0.94]; p < 0.001). The area under the ROC curve was 0.87 (95%CI: 0.80-0.93; p < 0.001) with a RER value (Youden index) of 0.92 giving a sensitivity of 91% and a specificity of 74% for predicting the occurrence of postoperative complications. The RER outperformed all other measured variables assessing the DO2/VO2 relationship (arterial lactate, SvO2, and VAPCO2gap) in predicting postoperative complications. CONCLUSION: During liver transplantation, the RER can reliably predict postoperative complications. Implementing this measure intraoperatively may provide a warning for physicians of impending complications and justify more aggressive optimization of oxygen delivery. Further studies are required to determine whether correcting the RER is feasible and could reduce the incidence of complications.


Subject(s)
Carbon Dioxide , Liver Transplantation , Adult , Humans , Liver Transplantation/adverse effects , Retrospective Studies , Lactic Acid , Oxygen , Oxygen Consumption , Postoperative Complications/diagnosis
4.
Anaesth Crit Care Pain Med ; 34(1): 57-60, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25829317

ABSTRACT

The authors report a case in which an intravenous injection of Patent Blue V dye instead of Indigo Carmine was given during routine gynaecological surgery. The patient presented with temporary arterial (spurious) desaturation and skin discoloration over a 48-hour period. Pharmacological differences between these dyes are described. Root cause analysis based on the ALARM (Association of Litigation and Risk Management) model is presented. The authors emphasise that use of this model should not be limited solely to describing and correcting well known systems errors such as working conditions or teamwork and communication. Furthermore, they conclude that insufficient knowledge must also be recognised as a systems error and as such should be sought out and corrected using similar strategies to those used to discover other contributory factors, without allocation of blame to any individual.


Subject(s)
Coloring Agents/adverse effects , Gynecologic Surgical Procedures/adverse effects , Medical Errors , Rosaniline Dyes/adverse effects , Aged, 80 and over , Female , Humans , Hysterectomy , Indigo Carmine
SELECTION OF CITATIONS
SEARCH DETAIL