Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 50
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Compr Psychiatry ; 131: 152463, 2024 05.
Article in English | MEDLINE | ID: mdl-38394926

ABSTRACT

BACKGROUND: The presence of psychiatric disorders is widely recognized as one of the primary risk factors for suicide. A significant proportion of individuals receiving outpatient psychiatric treatment exhibit varying degrees of suicidal behaviors, which may range from mild suicidal ideations to overt suicide attempts. This study aims to elucidate the transdiagnostic symptom dimensions and associated suicidal features among psychiatric outpatients. METHODS: The study enrolled patients who attended the psychiatry outpatient clinic at a tertiary hospital in South Korea (n = 1, 849, age range = 18-81; 61% women). A data-driven classification methodology was employed, incorporating a broad spectrum of clinical symptoms, to delineate distinctive subgroups among psychiatric outpatients exhibiting suicidality (n = 1189). A reference group of patients without suicidality (n = 660) was included for comparative purposes to ascertain cluster-specific sociodemographic, suicide-related, and psychiatric characteristics. RESULTS: Psychiatric outpatients with suicidality (n = 1189) were subdivided into three distinctive clusters: the low-suicide risk cluster (Cluster 1), the high-suicide risk externalizing cluster (Cluster 2), and the high-suicide risk internalizing cluster (Cluster 3). Relative to the reference group (n = 660), each cluster exhibited distinct attributes pertaining to suicide-related characteristics and clinical symptoms, covering domains such as anxiety, externalizing and internalizing behaviors, and feelings of hopelessness. Cluster 1, identified as the low-suicide risk group, exhibited less frequent suicidal ideation, planning, and multiple attempts. In the high-suicide risk groups, Cluster 2 displayed pronounced externalizing symptoms, whereas Cluster 3 was primarily defined by internalizing and hopelessness symptoms. Bipolar disorders were most common in Cluster 2, while depressive disorders were predominant in Cluster 3. DISCUSSION: Our findings suggest the possibility of differentiating psychiatric outpatients into distinct, clinically relevant subgroups predicated on their suicide risk. This research potentially paves the way for personalizing interventions and preventive strategies that address cluster-specific characteristics, thereby mitigating suicide-related mortality among psychiatric outpatients.


Subject(s)
Bipolar Disorder , Outpatients , Humans , Female , Adolescent , Young Adult , Adult , Middle Aged , Aged , Aged, 80 and over , Male , Suicide, Attempted/psychology , Bipolar Disorder/psychology , Anxiety Disorders/psychology , Suicidal Ideation , Risk Factors
2.
Neuroimage ; 282: 120411, 2023 11 15.
Article in English | MEDLINE | ID: mdl-37844771

ABSTRACT

Transcranial focused ultrasound (tFUS), in which acoustic energy is focused on a small region in the brain through the skull, is a non-invasive therapeutic method with high spatial resolution and depth penetration. Image-guided navigation has been widely utilized to visualize the location of acoustic focus in the cranial cavity. However, this system is often inaccurate because of the significant aberrations caused by the skull. Therefore, acoustic simulations using a numerical solver have been widely adopted to compensate for this inaccuracy. Although the simulation can predict the intracranial acoustic pressure field, real-time application during tFUS treatment is almost impossible due to the high computational cost. In this study, we propose a neural network-based real-time acoustic simulation framework and test its feasibility by implementing a simulation-guided navigation (SGN) system. Real-time acoustic simulation is performed using a 3D conditional generative adversarial network (3D-cGAN) model featuring residual blocks and multiple loss functions. This network was trained by the conventional numerical acoustic simulation program (i.e., k-Wave). The SGN system is then implemented by integrating real-time acoustic simulation with a conventional image-guided navigation system. The proposed system can provide simulation results with a frame rate of 5 Hz (i.e., about 0.2 s), including all processing times. In numerical validation (3D-cGAN vs. k-Wave), the average peak intracranial pressure error was 6.8 ± 5.5%, and the average acoustic focus position error was 5.3 ± 7.7 mm. In experimental validation using a skull phantom (3D-cGAN vs. actual measurement), the average peak intracranial pressure error was 4.5%, and the average acoustic focus position error was 6.6 mm. These results demonstrate that the SGN system can predict the intracranial acoustic field according to transducer placement in real-time.


Subject(s)
Brain , Skull , Humans , Feasibility Studies , Brain/diagnostic imaging , Skull/diagnostic imaging , Computer Simulation , Acoustics
3.
BMC Anesthesiol ; 21(1): 158, 2021 05 21.
Article in English | MEDLINE | ID: mdl-34020595

ABSTRACT

BACKGROUND: High-intensity ultrasound has been used to induce acoustic cavitation in the skin and subsequently enhances skin permeability to deliver hydrophobic topical medications including lidocaine. In contrast, instead of changing skin permeability, pulsed application of low-intensity focused ultrasound (FUS) has shown to non-invasively and temporarily disrupt drug-plasma protein binding, thus has potential to enhance the anesthetic effects of hydrophilic lidocaine hydrochloride through unbinding it from serum/interstitial α1-acid glycoprotein (AAG). METHODS: FUS, operating at fundamental frequency of 500 kHz, was applied pulse-mode (55-ms pulse duration, 4-Hz pulse repetition frequency) at a spatial-peak pulse-average intensity of 5 W/cm2. In vitro equilibrium dialysis was performed to measure the unbound concentration of lidocaine (lidocaine hydrochloride) from dialysis cassettes, one located at the sonication focus and the other outside the sonication path, all immersed in phosphate-buffered saline solution containing both lidocaine (10 µg/mL) and human AAG (5 mg/mL). In subsequent animal experiments (Sprague-Dawley rats, n = 10), somatosensory evoked potential (SSEP), elicited by electrical stimulations to the unilateral hind leg, was measured under three experimental conditions-applications of FUS to the unilateral thigh area at the site of administered topical lidocaine, FUS only, and lidocaine only. Skin temperature was measured before and after sonication. Passive cavitation detection was also performed during sonication to evaluate the presence of FUS-induced cavitation. RESULTS: Sonication increased the unbound lidocaine concentration (8.7 ± 3.3 %) from the dialysis cassette, compared to that measured outside the sonication path (P < 0.001). Application of FUS alone did not alter the SSEP while administration of lidocaine reduced its P23 component (i.e., a positive peak at 23 ms latency). The FUS combined with lidocaine resulted in a further reduction of the P23 component (in a range of 21.8 - 23.4 ms after the electrical stimulations; F(2,27) = 3.2 - 4.0, P < 0.05), indicative of the enhanced anesthetic effect of the lidocaine. Administration of FUS neither induced cavitation nor altered skin conductance or temperature, suggesting that skin permeability was unaffected. CONCLUSIONS: Unbinding lidocaine from the plasma proteins by exposure to non-thermal low-intensity ultrasound is attributed as the main mechanism behind the observation.


Subject(s)
Anesthetics, Local/pharmacology , Extracorporeal Shockwave Therapy/methods , Lidocaine/pharmacology , Skin/drug effects , Administration, Topical , Anesthetics, Local/administration & dosage , Animals , Lidocaine/administration & dosage , Models, Animal , Rats , Rats, Sprague-Dawley
4.
BMC Neurosci ; 19(1): 57, 2018 Sep 19.
Article in English | MEDLINE | ID: mdl-30231861

ABSTRACT

BACKGROUND: Low-intensity transcranial focused ultrasound (tFUS) has emerged as a new non-invasive modality of brain stimulation with the potential for high spatial selectivity and penetration depth. Anesthesia is typically applied in animal-based tFUS brain stimulation models; however, the type and depth of anesthesia are known to introduce variability in responsiveness to the stimulation. Therefore, the ability to conduct sonication experiments on awake small animals, such as rats, is warranted to avoid confounding effects of anesthesia. RESULTS: We developed a miniature tFUS headgear, operating at 600 kHz, which can be attached to the skull of Sprague-Dawley rats through an implanted pedestal, allowing the ultrasound to be transcranially delivered to motor cortical areas of unanesthetized freely-moving rats. Video recordings were obtained to monitor physical responses from the rat during acoustic brain stimulation. The stimulation elicited body movements from various areas, such as the tail, limbs, and whiskers. Movement of the head, including chewing behavior, was also observed. When compared to the light ketamine/xylazine and isoflurane anesthetic conditions, the response rate increased while the latency to stimulation decreased in the awake condition. The individual variability in response rates was smaller during the awake condition compared to the anesthetic conditions. Our analysis of latency distribution of responses also suggested possible presence of acoustic startle responses mixed with stimulation-related physical movement. Post-tFUS monitoring of animal behaviors and histological analysis performed on the brain did not reveal any abnormalities after the repeated tFUS sessions. CONCLUSIONS: The wearable miniature tFUS configuration allowed for the stimulation of motor cortical areas in rats and elicited sonication-related movements under both awake and anesthetized conditions. The awake condition yielded diverse physical responses compared to those reported in existing literatures. The ability to conduct an experiment in freely-moving awake animals can be gainfully used to investigate the effects of acoustic neuromodulation free from the confounding effects of anesthesia, thus, may serve as a translational platform to large animals and humans.


Subject(s)
Motor Activity/physiology , Motor Cortex/physiology , Ultrasonic Therapy/instrumentation , Ultrasonic Therapy/methods , Anesthesia , Animals , Equipment Design , Male , Miniaturization , Motor Cortex/cytology , Prostheses and Implants , Rats, Sprague-Dawley , Skull/surgery , Wakefulness
5.
Exp Dermatol ; 27(5): 453-459, 2018 05.
Article in English | MEDLINE | ID: mdl-28453913

ABSTRACT

This study reports a three-dimensional (3D) bioprinting technique that is capable of producing a full-thickness skin model containing pigmentation. Multiple layers of fibroblast (FB)-containing collagen hydrogel precursor were printed and crosslinked through neutralization using sodium bicarbonate, constituting the dermal layer. Melanocytes (MCs) and keratinocytes (KCs) were sequentially printed on top of the dermal layer to induce skin pigmentation upon subsequent air-liquid interface culture. Histological analysis was performed not only to confirm the formation of distinct skin layers, but also to identify the presence of pigmentation. The bioprinted skin structure showed the dermal and epidermal layers as well as the terminal differentiation of the KC that formed the stratum corneum. Moreover, the MC-containing epidermal layer showed freckle-like pigmentations at the dermal-epidermal junction, without the use of external ultraviolet light or chemical stimuli. The presented method offers the capability of producing engineered ephelides in biomimetic skin, thus rendering 3D bioprinting techniques as productive on-demand options for the creation of skin models available for therapeutic or research use.


Subject(s)
Bioprinting , Melanocytes , Printing, Three-Dimensional , Skin Pigmentation , Skin , Cells, Cultured , Humans
6.
BMC Neurosci ; 17(1): 68, 2016 10 26.
Article in English | MEDLINE | ID: mdl-27784293

ABSTRACT

BACKGROUND: Transcranial focused ultrasound (FUS) is gaining momentum as a novel non-invasive brain stimulation method, with promising potential for superior spatial resolution and depth penetration compared to transcranial magnetic stimulation or transcranial direct current stimulation. We examined the presence of tactile sensations elicited by FUS stimulation of two separate brain regions in humans-the primary (SI) and secondary (SII) somatosensory areas of the hand, as guided by individual-specific functional magnetic resonance imaging data. RESULTS: Under image-guidance, acoustic stimulations were delivered to the SI and SII areas either separately or simultaneously. The SII areas were divided into sub-regions that are activated by four types of external tactile sensations to the palmar side of the right hand-vibrotactile, pressure, warmth, and coolness. Across the stimulation conditions (SI only, SII only, SI and SII simultaneously), participants reported various types of tactile sensations that arose from the hand contralateral to the stimulation, such as the palm/back of the hand or as single/neighboring fingers. The type of tactile sensations did not match the sensations that are associated with specific sub-regions in the SII. The neuro-stimulatory effects of FUS were transient and reversible, and the procedure did not cause any adverse changes or discomforts in the subject's mental/physical status. CONCLUSIONS: The use of multiple FUS transducers allowed for simultaneous stimulation of the SI/SII in the same hemisphere and elicited various tactile sensations in the absence of any external sensory stimuli. Stimulation of the SII area alone could also induce perception of tactile sensations. The ability to stimulate multiple brain areas in a spatially restricted fashion can be used to study causal relationships between regional brain activities and their cognitive/behavioral outcomes.


Subject(s)
Acoustic Stimulation/methods , Echoencephalography/methods , Somatosensory Cortex/physiology , Touch Perception/physiology , Acoustic Stimulation/instrumentation , Adult , Arm/physiology , Echoencephalography/instrumentation , Equipment Design , Female , Follow-Up Studies , Functional Laterality , Humans , Leg/physiology , Magnetic Resonance Imaging , Multimodal Imaging , Somatosensory Cortex/diagnostic imaging , Tomography, X-Ray Computed , Young Adult
7.
BMC Vet Res ; 11: 262, 2015 Oct 14.
Article in English | MEDLINE | ID: mdl-26467856

ABSTRACT

BACKGROUND: An ovine model can cast great insight in translational neuroscientific research due to its large brain volume and distinct regional neuroanatomical structures. The present study examined the applicability of brain functional magnetic resonance imaging (fMRI) and diffusion tensor imaging (DTI) to sheep using a clinical MR scanner (3 tesla) with a head coil. The blood-oxygenation-level-dependent (BOLD) fMRI was performed on anesthetized sheep during the block-based presentation of external tactile and visual stimuli using gradient echo-planar-imaging (EPI) sequence. RESULTS: The individual as well as group-based data processing subsequently showed activation in the eloquent sensorimotor and visual areas. DTI was acquired using 26 differential magnetic gradient directions to derive directional fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values from the brain. White matter tractography was also applied to reveal the macrostructure of the corticospinal tracts and optic radiations. CONCLUSIONS: Utilization of fMRI and DTI along with anatomical MRI in the sheep brain could shed light on a broader use of an ovine model in the field of translational neuroscientific research targeting the brain.


Subject(s)
Brain/anatomy & histology , Diffusion Tensor Imaging/veterinary , Functional Neuroimaging/veterinary , Sheep/anatomy & histology , Animals , Brain/physiology , Female , Photic Stimulation , Physical Stimulation , Sheep/physiology , Touch Perception/physiology , Visual Perception/physiology
8.
Biomed Eng Lett ; 14(3): 407-438, 2024 May.
Article in English | MEDLINE | ID: mdl-38645585

ABSTRACT

Transcranial ultrasonic neuromodulation is a rapidly burgeoning field where low-intensity transcranial focused ultrasound (tFUS), with exquisite spatial resolution and deep tissue penetration, is used to non-invasively activate or suppress neural activity in specific brain regions. Over the past decade, there has been a rapid increase of tFUS neuromodulation studies in healthy humans and subjects with central nervous system (CNS) disease conditions, including a recent surge of clinical investigations in patients. This narrative review summarized the findings of human neuromodulation studies using either tFUS or unfocused transcranial ultrasound (TUS) reported from 2013 to 2023. The studies were categorized into two separate sections: healthy human research and clinical studies. A total of 42 healthy human investigations were reviewed as grouped by targeted brain regions, including various cortical, subcortical, and deep brain areas including the thalamus. For clinical research, a total of 22 articles were reviewed for each studied CNS disease condition, including chronic pain, disorder of consciousness, Alzheimer's disease, Parkinson's disease, depression, schizophrenia, anxiety disorders, substance use disorder, drug-resistant epilepsy, and stroke. Detailed information on subjects/cohorts, target brain regions, sonication parameters, outcome readouts, and stimulatory efficacies were tabulated for each study. In later sections, considerations for planning tFUS neuromodulation in humans were also concisely discussed. With an excellent safety profile to date, the rapid growth of human tFUS research underscores the increasing interest and recognition of its significant potential in the field of non-invasive brain stimulation (NIBS), offering theranostic potential for neurological and psychiatric disease conditions and neuroscientific tools for functional brain mapping.

9.
PLoS One ; 18(7): e0288654, 2023.
Article in English | MEDLINE | ID: mdl-37478086

ABSTRACT

The effects of transcranial focused ultrasound (FUS) stimulation of the primary somatosensory cortex and its thalamic projection (i.e., ventral posterolateral nucleus) on the generation of electroencephalographic (EEG) responses were evaluated in healthy human volunteers. Stimulation of the unilateral somatosensory circuits corresponding to the non-dominant hand generated EEG evoked potentials across all participants; however, not all perceived stimulation-mediated tactile sensations of the hand. These FUS-evoked EEG potentials (FEP) were observed from both brain hemispheres and shared similarities with somatosensory evoked potentials (SSEP) from median nerve stimulation. Use of a 0.5 ms pulse duration (PD) sonication given at 70% duty cycle, compared to the use of 1 and 2 ms PD, elicited more distinctive FEP peak features from the hemisphere ipsilateral to sonication. Although several participants reported hearing tones associated with FUS stimulation, the observed FEP were not likely to be confounded by the auditory sensation based on a separate measurement of auditory evoked potentials (AEP) to tonal stimulation (mimicking the same repetition frequency as the FUS stimulation). Off-line changes in resting-state functional connectivity (FC) associated with thalamic stimulation revealed that the FUS stimulation enhanced connectivity in a network of sensorimotor and sensory integration areas, which lasted for at least more than an hour. Clinical neurological evaluations, EEG, and neuroanatomical MRI did not reveal any adverse or unintended effects of sonication, attesting its safety. These results suggest that FUS stimulation may induce long-term neuroplasticity in humans, indicating its neurotherapeutic potential for various neurological and neuropsychiatric conditions.


Subject(s)
Hand , Sensation , Humans , Sensation/physiology , Evoked Potentials, Auditory , Evoked Potentials, Somatosensory/physiology , Sonication/methods , Somatosensory Cortex/diagnostic imaging , Somatosensory Cortex/physiology
10.
Sci Rep ; 13(1): 4128, 2023 03 13.
Article in English | MEDLINE | ID: mdl-36914775

ABSTRACT

The efficacy of many anti-epileptic drugs, including phenytoin (PHT), is reduced by plasma protein binding (PPB) that sequesters therapeutically active drug molecules within the bloodstream. An increase in systemic dose elevates the risk of drug side effects, which demands an alternative technique to increase the unbound concentration of PHT in a region-specific manner. We present a low-intensity focused ultrasound (FUS) technique that locally enhances the efficacy of PHT by transiently disrupting its binding to albumin. We first identified the acoustic parameters that yielded the highest PHT unbinding from albumin among evaluated parameter sets using equilibrium dialysis. Then, rats with chronic mesial temporal lobe epilepsy (mTLE) received four sessions of PHT injection, each followed by 30 min of FUS delivered to the ictal region, across 2 weeks. Two additional groups of mTLE rats underwent the same procedure, but without receiving PHT or FUS. Assessment of electrographic seizure activities revealed that FUS accompanying administration of PHT effectively reduced the number and mean duration of ictal events compared to other conditions, without damaging brain tissue or the blood-brain barrier. Our results demonstrated that the FUS technique enhanced the anti-epileptic efficacy of PHT in a chronic mTLE rodent model by region-specific PPB disruption.


Subject(s)
Epilepsy, Temporal Lobe , Phenytoin , Animals , Rats , Anticonvulsants/therapeutic use , Blood Proteins/metabolism , Epilepsy, Temporal Lobe/chemically induced , Epilepsy, Temporal Lobe/drug therapy , Phenytoin/pharmacology , Phenytoin/therapeutic use
11.
Neuropsychobiology ; 65(3): 153-60, 2012.
Article in English | MEDLINE | ID: mdl-22378299

ABSTRACT

OBJECTIVE: Transcranial focused ultrasound (FUS), with its ability to non-invasively modulate the excitability of region-specific brain areas, is gaining attention as a potential neurotherapeutic modality. The aim of this study was to examine whether or not FUS administered to the brain could alter the extracellular levels of glutamate and γ-aminobutyric acid (GABA), which are representative excitatory and inhibitory amino acid neurotransmitters, respectively. METHODS: FUS, delivered in the form of a train of pulses, was applied to the thalamus of Sprague-Dawley rats transcranially. Glutamate and GABA were directly sampled from the frontal lobe of the rat brain via a direct microdialysis technique before, during, and after the sonication. The dialysate concentrations were determined by high-performance liquid chromatography. RESULTS: The individual levels of the neurotransmitters sampled were normalized to the baseline level for each rat. In terms of the changes in extracellular glutamate levels, there was no difference between the FUS-treated group and the unsonicated control group. However, extracellular GABA levels started to decrease upon sonication and remained reduced (approximately 20% below baseline; repeated-measures ANOVA, p < 0.05, adjusted for multiple comparisons) compared to the control group. CONCLUSION: The ability to modulate region-specific brain activity, along with the present evidence of the ability to modulate neurotransmission, demonstrates the potential utility of FUS as a completely new non-invasive therapeutic modality.


Subject(s)
Extracellular Fluid/metabolism , Thalamus/diagnostic imaging , Thalamus/metabolism , Ultrasonography, Doppler, Transcranial , gamma-Aminobutyric Acid/metabolism , Analysis of Variance , Animals , Chromatography, High Pressure Liquid/methods , Glutamic Acid/metabolism , Male , Rats , Rats, Sprague-Dawley , Time Factors , Ultrasonography, Doppler, Transcranial/instrumentation
12.
Front Psychol ; 13: 951043, 2022.
Article in English | MEDLINE | ID: mdl-36275296

ABSTRACT

Background: Despite the growing evidence of cognitive impairments in bipolar disorder (BD), little work has evaluated cognitive performances utilizing the latest version of the Wechsler Intelligence Scale-IV (WAIS-IV), which is one of the most widely used neurocognitive assessments in clinical settings. Furthermore, clinical characteristics or demographic features that negatively affect the cognitive functioning of BD were not systematically compared or evaluated. Accordingly, the present study aimed to examine the cognitive profile of bipolar I disorder (BD-I) patients and associated risk factors. Methods: Participants included 45 patients, diagnosed with BD-I, current or most recent episode manic, and matching 46 healthy controls (HC). Cognitive performance was evaluated via WAIS-IV, and clinical characteristics of the BD-I group were examined via multiple self- and clinician-report questionnaires. Results: Multivariate analysis of covariance (MANCOVA) results indicated that the BD-I group demonstrated significantly poorer performance compared to the HC group in subtests and indexes that reflect working memory and processing speed abilities. Redundancy analysis revealed that overall symptom severity, manic symptom severity, and anxiety were significant predictors of cognitive performance in BD-I, while age of onset, past mood disorder history, depression severity, and impulsiveness showed comparatively smaller predictive values. Conclusion: The current study suggests cognitive deterioration in the cognitive proficiency area while generalized ability, including verbal comprehension and most of the perceptual reasoning skills, remain intact in BD-I. The identified risk factors of cognitive performance provide specific clinical recommendations for intervention and clinical decision-making.

13.
PLoS One ; 17(12): e0278865, 2022.
Article in English | MEDLINE | ID: mdl-36512563

ABSTRACT

Low-intensity transcranial focused ultrasound (tFUS) offers new functional neuromodulation opportunities, enabling stimulation of cortical as well as deep brain areas with high spatial resolution. Brain stimulation of awake sheep, in the absence of the confounding effects of anesthesia on brain function, provides translational insight into potential human applications with safety information supplemented by histological analyses. We examined the effects of tFUS pulsing parameters, particularly regarding pulse durations (PDs), on stimulating the cortical motor area (M1) and its thalamic projection in unanesthetized, awake sheep (n = 8). A wearable tFUS headgear, custom-made for individual sheep, enabled experiments to be conducted without using anesthesia. FUS stimuli, each 200 ms long, were delivered to the M1 and the thalamus using three different PDs (0.5, 1, and 2 ms) with the pulse repetition frequency (PRF) adjusted to maintain a 70% duty cycle at a derated in situ spatial-peak temporal-average intensity (Ispta) of 3.6 W/cm2. Efferent electromyography (EMG) responses to stimulation were quantified from both hind limbs. Group-averaged EMG responses from each of the hind limbs across the experimental conditions revealed selective responses from the hind limb contralateral to sonication. The use of 0.5 and 1 ms PDs generated higher EMG signal amplitudes compared to those obtained using a 2 ms PD. Faster efferent response was also observed from thalamic stimulation than that from stimulating the M1. Post-sonication behavioral observation and histological assessment performed 24 h and 1 month after sonication were not indicative of any abnormalities. The results suggest the presence of pulsing scheme-dependent effects of tFUS on brain stimulation and attest its safety in awake large animals.


Subject(s)
Motor Cortex , Wakefulness , Humans , Animals , Sheep , Brain Mapping/methods , Brain/physiology , Motor Cortex/physiology , Heart Rate
14.
J Pers Med ; 12(2)2022 Feb 09.
Article in English | MEDLINE | ID: mdl-35207738

ABSTRACT

Preclinical studies have suggested that low-intensity transcranial focused ultrasound (tFUS) may have therapeutic potential for Alzheimer's disease (AD) by opening the blood-brain barrier (BBB), reducing amyloid pathology, and improving cognition. This study investigated the effects of tFUS on BBB opening, regional cerebral metabolic rate of glucose (rCMRglu), and cognitive function in AD patients. Eight patients with AD received image-guided tFUS to the right hippocampus immediately after intravenous injection of microbubble ultrasound contrast agents. Patients completed magnetic resonance imaging (MRI), 18F-fluoro-2-deoxyglucose positron emission tomography (PET), and cognitive assessments before and after the sonication. No evidence of transient BBB opening was found on T1 dynamic contrast-enhanced MRI. However, immediate recall (p = 0.03) and recognition memory (p = 0.02) were significantly improved on the verbal learning test. PET image analysis demonstrated increased rCMRglu in the right hippocampus (p = 0.001). In addition, increases of hippocampal rCMRglu were correlated with improvement in recognition memory (Spearman's ρ = 0.77, p = 0.02). No adverse event was observed. Our results suggest that tFUS to the hippocampus of AD patients may improve rCMRglu of the target area and memory in the short term, even without BBB opening. Further larger sham-controlled trials with loger follow-up are warranted to evaluate the efficacy and safety of tFUS in patients with AD.

15.
Biomacromolecules ; 12(1): 14-8, 2011 Jan 10.
Article in English | MEDLINE | ID: mdl-21138286

ABSTRACT

We report a facile method to fabricate free-standing, 3D hydrogel microarchitectures of chemically sol-gel transitional hydrogels, which is based on the use of hydrophilic substrate and aerosol of gelling agent without molding (or sandwiching) process. Using proposed methods, we fabricated hydrogel microarchitectures of sheets, meshes, or microunits without morphological distortions on the microscale. These hydrogel microarchitectures could be easily and stably exfoliated from the substrates and cultured (in the case of containing cells). These free-standing hydrogel microarchitectures in sheets, meshes, or microunits can be easily harvested and assembled as a biofabrication unit to generate complex composites with controlled microscale structures.


Subject(s)
Biocompatible Materials , Hydrogels , Materials Testing , Biocompatible Materials/chemical synthesis , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Hep G2 Cells , Humans , Hydrogels/chemical synthesis , Hydrogels/chemistry , Hydrogels/pharmacology , Hydrophobic and Hydrophilic Interactions
16.
Brain Neurorehabil ; 14(1): e4, 2021 Mar.
Article in English | MEDLINE | ID: mdl-36742103

ABSTRACT

Ultrasound is an important theragnostic modality in modern medicine. Technical advancement of both acoustic focusing and transcranial delivery have enabled administration of ultrasound waves to localized brain areas with few millimeters of spatial specificity and penetration depth sufficient to reach the thalamus. Transcranial focused ultrasound (tFUS) given at a low acoustic intensity has been shown to increase or suppress the excitability of region-specific brain areas. The neuromodulatory effects can outlast the sonication, suggesting the possibility of inducing neural plasticity needed for neurorehabilitation. Increasing numbers of studies have shown the efficacy and excellent safety profile of the technique, yet comparisons among the safety-related parameters have not been compiled. This review aims to provide safety information and perspectives of tFUS brain stimulation. First, the acoustic parameters most relevant to thermal/mechanical tissue damage are discussed along with regulated parameters for existing ultrasound therapies/diagnostic imaging. Subsequently, the parameters used in studies of large animals, non-human primates, and humans are surveyed and summarized in terms of the acoustic intensity and the mechanical index. The pulse-mode operation and the use of low ultrasound frequency for tFUS-mediated brain stimulation warrant the establishment of new safety guidelines/recommendations for the use of the technique among healthy volunteers, with additional cautionary requirements for its clinical translation.

17.
iScience ; 24(11): 103372, 2021 Nov 19.
Article in English | MEDLINE | ID: mdl-34825139

ABSTRACT

To address current unmet needs in terms of scalability and material biocompatibility for future photocrosslinking-based additive manufacturing technologies, emergent platform designs are in inexorable demand. In particular, a shift from the present use of cell-damaging UV light sources in light-based three-dimensional (3D) bioprinting methods demands new platforms. We adopted an organic light-emitting diode (OLED) microdisplay as a digital visible light modulator to create a 3D printing platform modality that offers scalability and multi-material capability while forgoing the need for UV photocrosslinking. We formulate biocompatible inks that are visible light-crosslinkable with relatively quick photoinitiation rates. We demonstrated successful attachment and rapid growth of primary human dermal fibroblast-adult (HDF-a) cells on biological substrates fabricated using the OLED platform. This platform incites new possibilities by providing a simple-yet-effective means for low-cost, high-throughput, and multi-material 3D fabrication of functional structures made of polymers, ceramic composites, and biomaterials.

18.
Sci Rep ; 11(1): 19274, 2021 09 29.
Article in English | MEDLINE | ID: mdl-34588588

ABSTRACT

Transcranial application of pulsed low-intensity focused ultrasound (FUS) modulates the excitability of region-specific brain areas, and anesthetic confounders on brain activity warrant the evaluation of the technique in awake animals. We examined the neuromodulatory effects of FUS in unanesthetized sheep by developing a custom-fit headgear capable of reproducibly placing an acoustic focus on the unilateral motor cortex (M1) and corresponding thalamic area. The efferent responses to sonication, based on the acoustic parameters previously identified in anesthetized sheep, were measured using electromyography (EMG) from both hind limbs across three experimental conditions: on-target sonication, off-target sonication, and without sonication. Excitatory sonication yielded greater amplitude of EMG signals obtained from the hind limb contralateral to sonication than that from the ipsilateral limb. Spurious appearance of motion-related EMG signals limited the amount of analyzed data (~ 10% selection of acquired data) during excitatory sonication, and the averaged EMG response rates elicited by the M1 and thalamic stimulations were 7.5 ± 1.4% and 6.7 ± 1.5%, respectively. Suppressive sonication, while sheep walked on the treadmill, temporarily reduced the EMG amplitude from the limb contralateral to sonication. No significant change was found in the EMG amplitudes during the off-target sonication. Behavioral observation throughout the study and histological analysis showed no sign of brain tissue damage caused by the acoustic stimulation. Marginal response rates observed during excitatory sonication call for technical refinement to reduce motion artifacts during EMG acquisitions as well as acoustic aberration correction schemes to improve spatial accuracy of sonication. Yet, our results indicate that low-intensity FUS modulated the excitability of regional brain tissues reversibly and safely in awake sheep, supporting its potential in theragnostic applications.


Subject(s)
Motor Activity/radiation effects , Motor Cortex/radiation effects , Thalamus/radiation effects , Ultrasonic Therapy/methods , Animals , Electromyography , Female , Models, Animal , Motor Activity/physiology , Motor Cortex/physiology , Sheep , Thalamus/physiology , Ultrasonic Therapy/adverse effects , Ultrasonic Waves/adverse effects , Wakefulness
19.
Ultrasonography ; 40(4): 512-519, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33730775

ABSTRACT

PURPOSE: Increasing attention has been paid to low-intensity transcranial focused ultrasound (tFUS) for its potential therapeutic effects in Alzheimer's disease (AD). While preclinical studies have shown promising therapeutic effects of low-intensity tFUS in AD models, its efficacy and safety remain unclear in humans. In this pilot study, we investigated the effects of low-intensity tFUS on blood-brain barrier opening, the regional cerebral metabolic rate of glucose (rCMRglu), and cognition in patients with AD. METHODS: After receiving institutional review board approval, four patients with AD received tFUS to the hippocampus immediately after an intravenous injection of a microbubble ultrasound contrast agent. Sonication was delivered at low-intensity, at a pressure level below the threshold for blood-brain barrier opening. Patients underwent brain magnetic resonance imaging, 18F-fluoro-2-deoxyglucose positron emission tomography, and neuropsychological assessments before and after the tFUS procedure. A whole-brain voxel-wise paired t test was conducted to compare rCMRglu before and after tFUS. RESULTS: The sonication, as anticipated, did not show evidence of active blood-brain barrier opening on T1 dynamic contrast-enhanced magnetic resonance imaging. rCMRglu in the superior frontal gyrus (P<0.001), middle cingulate gyrus (P<0.001), and fusiform gyrus increased after tFUS (P=0.001). Patients demonstrated mild improvement in measures of memory, executive, and global cognitive function following tFUS. No adverse events were reported. CONCLUSION: These results suggest that hippocampal sonication with low-intensity tFUS may have beneficial effects on cerebral glucose metabolism and cognitive function in patients with AD. Further larger studies are needed to confirm the therapeutic efficacy of tFUS in AD.

20.
Biotechnol Bioeng ; 105(6): 1178-86, 2010 Apr 15.
Article in English | MEDLINE | ID: mdl-19953677

ABSTRACT

One of the challenges in tissue engineering is to provide adequate supplies of oxygen and nutrients to cells within the engineered tissue construct. Soft-lithographic techniques have allowed the generation of hydrogel scaffolds containing a network of fluidic channels, but at the cost of complicated and often time-consuming manufacturing steps. We report a three-dimensional (3D) direct printing technique to construct hydrogel scaffolds containing fluidic channels. Cells can also be printed on to and embedded in the scaffold with this technique. Collagen hydrogel precursor was printed and subsequently crosslinked via nebulized sodium bicarbonate solution. A heated gelatin solution, which served as a sacrificial element for the fluidic channels, was printed between the collagen layers. The process was repeated layer-by-layer to form a 3D hydrogel block. The printed hydrogel block was heated to 37 degrees C, which allowed the gelatin to be selectively liquefied and drained, generating a hollow channel within the collagen scaffold. The dermal fibroblasts grown in a scaffold containing fluidic channels showed significantly elevated cell viability compared to the ones without any channels. The on-demand capability to print fluidic channel structures and cells in a 3D hydrogel scaffold offers flexibility in generating perfusable 3D artificial tissue composites.


Subject(s)
Hydrogel, Polyethylene Glycol Dimethacrylate/chemistry , Microfluidic Analytical Techniques/methods , Tissue Engineering/methods , Tissue Scaffolds/chemistry , Collagen/chemistry , Fibroblasts/cytology , Fibroblasts/physiology , Gelatin/chemistry , Microfluidic Analytical Techniques/instrumentation , Particle Size , Perfusion/instrumentation , Perfusion/methods , Tissue Engineering/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL