1.
Gastroenterology ; 164(6): 978-989.e6, 2023 05.
Article in English | MEDLINE | ID: mdl-36775072

ABSTRACT

BACKGROUND & AIMS: Previous studies have shown an increasing incidence of pancreatic cancer (PC), especially in younger women; however, this has not been externally validated. In addition, there are limited data about contributing factors to this trend. We report age and sex-specific time-trend analysis of PC age-adjusted incidence rates (aIRs) using the National Program of Cancer Registries database without Surveillance Epidemiology and End Results data. METHODS: PC aIR, mortality rates, annual percentage change, and average annual percentage change (AAPC) were calculated and assessed for parallelism and identicalness. Age-specific analyses were conducted in older (≥55 years) and younger (<55 years) adults. PC incidence based on demographics, tumor characteristics, and mortality were evaluated in younger adults. RESULTS: A total of 454,611 patients were diagnosed with PC between 2001 and 2018 with significantly increasing aIR in women (AAPC = 1.27%) and men (AAPC = 1.14%) without a difference (P = .37). Similar results were seen in older adults. However, in younger adults (53,051 cases; 42.9% women), women experienced a greater increase in aIR than men (AAPCs = 2.36%, P < .001 vs 0.62%, P = 0.62) with nonparallel trends (P < .001) and AAPC difference of 1.74% (P < .001). This AAPC difference appears to be due to rising aIR in Blacks (2.23%; P < .001), adenocarcinoma histopathologic subtype (0.89%; P = .003), and location in the head-of-pancreas (1.64%; P < .001). PC mortality was found to be unchanged in women but decreasing in counterpart men (AAPC difference = 0.54%; P = .001). CONCLUSION: Using nationwide data, covering ≈64.5% of the U.S. population, we externally validate a rapidly increasing aIR of PC in younger women. There was a big separation of the incidence trend between women and men aged 15-34 years between 2001 and 2018 (>200% difference), and it did not show slowing down.


Subject(s)
Pancreatic Neoplasms , Male , Humans , Female , United States/epidemiology , Aged , Incidence , Registries , Pancreatic Neoplasms/epidemiology , Pancreas , Pancreatic Neoplasms
2.
Magn Reson Med ; 2024 Sep 13.
Article in English | MEDLINE | ID: mdl-39270056

ABSTRACT

PURPOSE: To shorten CEST acquisition time by leveraging Z-spectrum undersampling combined with deep learning for CEST map construction from undersampled Z-spectra. METHODS: Fisher information gain analysis identified optimal frequency offsets (termed "Fisher offsets") for the multi-pool fitting model, maximizing information gain for the amplitude and the FWHM parameters. These offsets guided initial subsampling levels. A U-NET, trained on undersampled brain CEST images from 18 volunteers, produced CEST maps at 3 T with varied undersampling levels. Feasibility was first tested using retrospective undersampling at three levels, followed by prospective in vivo undersampling (15 of 53 offsets), reducing scan time significantly. Additionally, glioblastoma grade IV pathology was simulated to evaluate network performance in patient-like cases. RESULTS: Traditional multi-pool models failed to quantify CEST maps from undersampled images (structural similarity index [SSIM] <0.2, peak SNR <20, Pearson r <0.1). Conversely, U-NET fitting successfully addressed undersampled data challenges. The study suggests CEST scan time reduction is feasible by undersampling 15, 25, or 35 of 53 Z-spectrum offsets. Prospective undersampling cut scan time by 3.5 times, with a maximum mean squared error of 4.4e-4, r = 0.82, and SSIM = 0.84, compared to the ground truth. The network also reliably predicted CEST values for simulated glioblastoma pathology. CONCLUSION: The U-NET architecture effectively quantifies CEST maps from undersampled Z-spectra at various undersampling levels.

3.
Magn Reson Med ; 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39014982

ABSTRACT

PURPOSE: To develop a self-supervised learning method to retrospectively estimate T1 and T2 values from clinical weighted MRI. METHODS: A self-supervised learning approach was constructed to estimate T1, T2, and proton density maps from conventional T1- and T2-weighted images. MR physics models were employed to regenerate the weighted images from the network outputs, and the network was optimized based on loss calculated between the synthesized and input weighted images, alongside additional constraints based on prior information. The method was evaluated on healthy volunteer data, with conventional mapping as references. The reproducibility was examined on two 3.0T scanners. Performance in tumor characterization was inspected by applying the method to a public glioblastoma dataset. RESULTS: For T1 and T2 estimation from three weighted images (T1 MPRAGE, T1 gradient echo sequences, and T2 turbo spin echo), the deep learning method achieved global voxel-wise error ≤9% in brain parenchyma and regional error ≤12.2% in six types of brain tissues. The regional measurements obtained from two scanners showed mean differences ≤2.4% and correlation coefficients >0.98, demonstrating excellent reproducibility. In the 50 glioblastoma patients, the retrospective quantification results were in line with literature reports from prospective methods, and the T2 values were found to be higher in tumor regions, with sensitivity of 0.90 and specificity of 0.92 in a voxel-wise classification task between normal and abnormal regions. CONCLUSION: The self-supervised learning method is promising for retrospective T1 and T2 quantification from clinical MR images, with the potential to improve the availability of quantitative MRI and facilitate brain tumor characterization.

4.
Magn Reson Med ; 92(4): 1421-1439, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38726884

ABSTRACT

PURPOSE: To develop a novel low-rank tensor reconstruction approach leveraging the complete acquired data set to improve precision and repeatability of multiparametric mapping within the cardiovascular MR Multitasking framework. METHODS: A novel approach that alternated between estimation of temporal components and spatial components using the entire data set acquired (i.e., including navigator data and imaging data) was developed to improve reconstruction. The precision and repeatability of the proposed approach were evaluated on numerical simulations, 10 healthy subjects, and 10 cardiomyopathy patients at multiple scan times for 2D myocardial T1/T2 mapping with MR Multitasking and were compared with those of the previous navigator-derived fixed-basis approach. RESULTS: In numerical simulations, the proposed approach outperformed the previous fixed-basis approach with lower T1 and T2 error against the ground truth at all scan times studied and showed better motion fidelity. In human subjects, the proposed approach showed no significantly different sharpness or T1/T2 measurement and significantly improved T1 precision by 20%-25%, T2 precision by 10%-15%, T1 repeatability by about 30%, and T2 repeatability by 25%-35% at 90-s and 50-s scan times The proposed approach at the 50-s scan time also showed comparable results with that of the previous fixed-basis approach at the 90-s scan time. CONCLUSION: The proposed approach improved precision and repeatability for quantitative imaging with MR Multitasking while maintaining comparable motion fidelity, T1/T2 measurement, and septum sharpness and had the potential for further reducing scan time from 90 s to 50 s.


Subject(s)
Algorithms , Humans , Reproducibility of Results , Male , Female , Image Interpretation, Computer-Assisted/methods , Adult , Image Enhancement/methods , Middle Aged , Sensitivity and Specificity , Image Processing, Computer-Assisted/methods , Cardiomyopathies/diagnostic imaging , Multiparametric Magnetic Resonance Imaging/methods , Heart/diagnostic imaging
5.
Magn Reson Med ; 2024 Aug 22.
Article in English | MEDLINE | ID: mdl-39171431

ABSTRACT

PURPOSE: Radiotherapy treatment planning (RTP) using MR has been used increasingly for the abdominal site. Multiple contrast weightings and motion-resolved imaging are desired for accurate delineation of the target and various organs-at-risk and patient-tailored planning. Current MR protocols achieve these through multiple scans with distinct contrast and variable respiratory motion management strategies and acquisition parameters, leading to a complex and inaccurate planning process. This study presents a standalone MR Multitasking (MT)-based technique to produce volumetric, motion-resolved, multicontrast images for abdominal radiotherapy treatment planning. METHODS: The MT technique resolves motion and provides a wide range of contrast weightings by repeating a magnetization-prepared (saturation recovery and T2 preparations) spoiled gradient-echo readout series and adopting the MT image reconstruction framework. The performance of the technique was assessed through digital phantom simulations and in vivo studies of both healthy volunteers and patients with liver tumors. RESULTS: In the digital phantom study, the MT technique presented structural details and motion in excellent agreement with the digital ground truth. The in vivo studies showed that the motion range was highly correlated (R2 = 0.82) between MT and 2D cine imaging. MT allowed for a flexible contrast-weighting selection for better visualization. Initial clinical testing with interobserver analysis demonstrated acceptable target delineation quality (Dice coefficient = 0.85 ± 0.05, Hausdorff distance = 3.3 ± 0.72 mm). CONCLUSION: The developed MT-based, abdomen-dedicated technique is capable of providing motion-resolved, multicontrast volumetric images in a single scan, which may facilitate abdominal radiotherapy treatment planning.

6.
Magn Reson Med ; 91(5): 1936-1950, 2024 May.
Article in English | MEDLINE | ID: mdl-38174593

ABSTRACT

PURPOSE: Widely used conventional 2D T2 * approaches that are based on breath-held, electrocardiogram (ECG)-gated, multi-gradient-echo sequences are prone to motion artifacts in the presence of incomplete breath holding or arrhythmias, which is common in cardiac patients. To address these limitations, a 3D, non-ECG-gated, free-breathing T2 * technique that enables rapid whole-heart coverage was developed and validated. METHODS: A continuous random Gaussian 3D k-space sampling was implemented using a low-rank tensor framework for motion-resolved 3D T2 * imaging. This approach was tested in healthy human volunteers and in swine before and after intravenous administration of ferumoxytol. RESULTS: Spatial-resolution matched T2 * images were acquired with 2-3-fold reduction in scan time using the proposed T2 * mapping approach relative to conventional T2 * mapping. Compared with the conventional approach, T2 * images acquired with the proposed method demonstrated reduced off-resonance and flow artifacts, leading to higher image quality and lower coefficient of variation in T2 *-weighted images of the myocardium of swine and humans. Mean myocardial T2 * values determined using the proposed and conventional approaches were highly correlated and showed minimal bias. CONCLUSION: The proposed non-ECG-gated, free-breathing, 3D T2 * imaging approach can be performed within 5 min or less. It can overcome critical image artifacts from undesirable cardiac and respiratory motion and bulk off-resonance shifts at the heart-lung interface. The proposed approach is expected to facilitate faster and improved cardiac T2 * mapping in those with limited breath-holding capacity or arrhythmias.


Subject(s)
Heart , Myocardium , Humans , Animals , Swine , Heart/diagnostic imaging , Respiration , Breath Holding , Magnetic Resonance Imaging, Cine/methods , Magnetic Resonance Imaging , Imaging, Three-Dimensional/methods
7.
J Cardiovasc Magn Reson ; 26(2): 101047, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38825155

ABSTRACT

BACKGROUND: Coronary artery wall contrast enhancement (CE) has been applied to non-invasive visualization of changes to the coronary artery wall in systemic lupus erythematosus (SLE). This study investigated the feasibility of quantifying CE to detect coronary involvement in IgG4-related disease (IgG4-RD), as well as the influence on disease activity assessment. METHODS: A total of 93 subjects (31 IgG4-RD; 29 SLE; 33 controls) were recruited in the study. Coronary artery wall imaging was performed in a 3.0 T MRI scanner. Serological markers and IgG4-RD Responder Index (IgG4-RD-RI) scores were collected for correlation analysis. RESULTS: Coronary wall CE was observed in 29 (94 %) IgG4-RD patients and 22 (76 %) SLE patients. Contrast-to-noise ratio (CNR) and total CE area were significantly higher in patient groups compared to controls (CNR: 6.1 ± 2.7 [IgG4-RD] v. 4.2 ± 2.3 [SLE] v. 1.9 ± 1.5 [control], P < 0.001; Total CE area: 3.0 [3.0-6.6] v. 1.7 [1.5-2.6] v. 0.3 [0.3-0.9], P < 0.001). In the IgG4-RD group, CNR and total CE area were correlated with the RI (CNR: r = 0.55, P = 0.002; total CE area: r = 0.39, P = 0.031). RI´ scored considering coronary involvement by CE, differed significantly from RI scored without consideration of CE (RI v. RI´: 15 ± 6 v. 16 ± 6, P < 0.001). CONCLUSIONS: Visualization and quantification of CMR coronary CE by CNR and total CE area could be utilized to detect subclinical and clinical coronary wall involvement, which is prevalent in IgG4-RD. The potential inclusion of small and medium-sized vessel involvements in the assessment of disease activity in IgG4-RD is worthy of further investigation.

8.
J Cardiovasc Magn Reson ; 26(1): 100999, 2024.
Article in English | MEDLINE | ID: mdl-38237903

ABSTRACT

BACKGROUND: High-intensity plaque (HIP) on magnetic resonance imaging (MRI) has been documented as a powerful predictor of periprocedural myocardial injury (PMI) following percutaneous coronary intervention (PCI). Despite the recent proposal of three-dimensional HIP quantification to enhance the predictive capability, the conventional pulse sequence, which necessitates the separate acquisition of anatomical reference images, hinders accurate three-dimensional segmentation along the coronary vasculature. Coronary atherosclerosis T1-weighted characterization (CATCH) enables the simultaneous acquisition of inherently coregistered dark-blood plaque and bright-blood coronary artery images. We aimed to develop a novel HIP quantification approach using CATCH and to ascertain its superior predictive performance compared to the conventional two-dimensional assessment based on plaque-to-myocardium signal intensity ratio (PMR). METHODS: In this prospective study, CATCH MRI was conducted before elective stent implantation in 137 lesions from 125 patients. On CATCH images, dedicated software automatically generated tubular three-dimensional volumes of interest on the dark-blood plaque images along the coronary vasculature, based on the precisely matched bright-blood coronary artery images, and subsequently computed PMR and HIP volume (HIPvol). Specifically, HIPvol was calculated as the volume of voxels with signal intensity exceeding that of the myocardium, weighted by their respective signal intensities. PMI was defined as post-PCI cardiac troponin-T > 5 × the upper reference limit. RESULTS: The entire analysis process was completed within 3 min per lesion. PMI occurred in 44 lesions. Based on the receiver operating characteristic curve analysis, HIPvol outperformed PMR for predicting PMI (C-statistics, 0.870 [95% CI, 0.805-0.936] vs. 0.787 [95% CI, 0.706-0.868]; p = 0.001). This result was primarily driven by the higher sensitivity HIPvol offered: 0.886 (95% CI, 0.754-0.962) vs. 0.750 for PMR (95% CI, 0.597-0.868; p = 0.034). Multivariable analysis identified HIPvol as an independent predictor of PMI (odds ratio, 1.15 per 10-µL increase; 95% CI, 1.01-1.30, p = 0.035). CONCLUSIONS: Our semi-automated method of analyzing coronary plaque using CATCH MRI provided rapid HIP quantification. Three-dimensional assessment using this approach had a better ability to predict PMI than conventional two-dimensional assessment.


Subject(s)
Coronary Artery Disease , Coronary Vessels , Image Interpretation, Computer-Assisted , Imaging, Three-Dimensional , Percutaneous Coronary Intervention , Plaque, Atherosclerotic , Predictive Value of Tests , Humans , Male , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/pathology , Prospective Studies , Female , Middle Aged , Aged , Percutaneous Coronary Intervention/adverse effects , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Risk Factors , Treatment Outcome , Stents , Area Under Curve , ROC Curve , Magnetic Resonance Imaging , Reproducibility of Results
9.
Magn Reson Med ; 90(6): 2362-2374, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37578085

ABSTRACT

PURPOSE: Deep learning superresolution (SR) is a promising approach to reduce MRI scan time without requiring custom sequences or iterative reconstruction. Previous deep learning SR approaches have generated low-resolution training images by simple k-space truncation, but this does not properly model in-plane turbo spin echo (TSE) MRI resolution degradation, which has variable T2 relaxation effects in different k-space regions. To fill this gap, we developed a T2 -deblurred deep learning SR method for the SR of 3D-TSE images. METHODS: A SR generative adversarial network was trained using physically realistic resolution degradation (asymmetric T2 weighting of raw high-resolution k-space data). For comparison, we trained the same network structure on previous degradation models without TSE physics modeling. We tested all models for both retrospective and prospective SR with 3 × 3 acceleration factor (in the two phase-encoding directions) of genetically engineered mouse embryo model TSE-MR images. RESULTS: The proposed method can produce high-quality 3 × 3 SR images for a typical 500-slice volume with 6-7 mouse embryos. Because 3 × 3 SR was performed, the image acquisition time can be reduced from 15 h to 1.7 h. Compared to previous SR methods without TSE modeling, the proposed method achieved the best quantitative imaging metrics for both retrospective and prospective evaluations and achieved the best imaging-quality expert scores for prospective evaluation. CONCLUSION: The proposed T2 -deblurring method improved accuracy and image quality of deep learning-based SR of TSE MRI. This method has the potential to accelerate TSE image acquisition by a factor of up to 9.


Subject(s)
Deep Learning , Animals , Mice , Retrospective Studies , Magnetic Resonance Imaging/methods , Imaging, Three-Dimensional/methods
10.
Magn Reson Med ; 89(2): 738-745, 2023 02.
Article in English | MEDLINE | ID: mdl-36161668

ABSTRACT

PURPOSE: To develop a novel 3D abdominal CEST MRI technique at 3 T using MR multitasking, which enables entire-liver coverage with free-breathing acquisition. METHODS: k-Space data were continuously acquired with repetitive steady-state CEST (ss-CEST) modules. The stack-of-stars acquisition pattern was used for k-space sampling. MR multitasking was used to reconstruct motion-resolved 3D CEST images of 53 frequency offsets with entire-liver coverage and 2.0 × 2.0 × 6.0 mm3 spatial resolution. The total scan time was 9 min. The sensitivity of amide proton transfer (APT)-CEST (magnetization transfer asymmetry [MTRasym ] at 3.5 ppm) and glycogen CEST (glycoCEST) (mean MTRasym around 1.0 ppm) signals generated with the proposed method were tested with fasting experiments. RESULTS: Both APT-CEST and glycoCEST signals showed high sensitivity between post-fasting and post-meal acquisitions. APT-CEST and glycoCEST MTRasym signals from post-mean scans were significantly increased (APT-CEST: -0.019 ± 0.017 in post-fasting scans, 0.014 ± 0.021 in post-meal scans, p < 0.01; glycoCEST: 0.003 ± 0.009 in post-fasting scans, 0.027 ± 0.021 in post-meal scans, p < 0.01). CONCLUSION: The proposed 3D abdominal steady-state CEST method using MR multitasking can generate CEST images of the entire liver during free breathing.


Subject(s)
Magnetic Resonance Imaging , Protons , Humans , Magnetic Resonance Imaging/methods , Liver/diagnostic imaging , Imaging, Three-Dimensional , Amides
11.
Magn Reson Med ; 89(4): 1496-1505, 2023 04.
Article in English | MEDLINE | ID: mdl-36336794

ABSTRACT

PURPOSE: To extend the MR MultiTasking-based Multidimensional Assessment of Cardiovascular System (MT-MACS) technique with larger spatial coverage and water-fat separation for comprehensive aortocardiac assessment. METHODS: MT-MACS adopts a low-rank tensor image model for 7D imaging, with three spatial dimensions for volumetric imaging, one cardiac motion dimension for cine imaging, one respiratory motion dimension for free-breathing imaging, one T2-prepared inversion recovery time dimension for multi-contrast assessment, and one T2*-decay time dimension for water-fat separation. Nine healthy subjects were recruited for the 3T study. Overall image quality was scored on bright-blood (BB), dark-blood (DB), and gray-blood (GB) contrasts using a 4-point scale (0-poor to 3-excellent) by two independent readers, and their interreader agreement was evaluated. Myocardial wall thickness and left ventricular ejection fraction (LVEF) were quantified on DB and BB contrasts, respectively. The agreement in these metrics between MT-MACS and conventional breath-held, electrocardiography-triggered 2D sequences were evaluated. RESULTS: MT-MACS provides both water-only and fat-only images with excellent image quality (average score = 3.725/3.780/3.835/3.890 for BB/DB/GB/fat-only images) and moderate to high interreader agreement (weighted Cohen's kappa value = 0.727/0.668/1.000/1.000 for BB/DB/GB/fat-only images). There were good to excellent agreements in myocardial wall thickness measurements (intraclass correlation coefficients [ICC] = 0.781/0.929/0.680/0.878 for left atria/left ventricle/right atria/right ventricle) and LVEF quantification (ICC = 0.716) between MT-MACS and 2D references. All measurements were within the literature range of healthy subjects. CONCLUSION: The refined MT-MACS technique provides multi-contrast, phase-resolved, and water-fat imaging of the aortocardiac systems and allows evaluation of anatomy and function. Clinical validation is warranted.


Subject(s)
Imaging, Three-Dimensional , Water , Humans , Stroke Volume , Imaging, Three-Dimensional/methods , Ventricular Function, Left , Heart Ventricles , Reproducibility of Results , Magnetic Resonance Imaging
12.
Magn Reson Med ; 89(1): 161-176, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36128892

ABSTRACT

PURPOSE: To develop an MR multitasking-based dynamic imaging for cerebrovascular evaluation (MT-DICE) technique for simultaneous quantification of permeability and leakage-insensitive perfusion with a single-dose contrast injection. METHODS: MT-DICE builds on a saturation-recovery prepared multi-echo fast low-angle shot sequence. The k-space is randomly sampled for 7.6 min, with single-dose contrast agent injected 1.5 min into the scan. MR multitasking is used to model the data into six dimensions, including three spatial dimensions for whole-brain coverage, a saturation-recovery time dimension, and a TE dimension for dynamic T 1 $$ {\mathrm{T}}_1 $$ and T 2 * $$ {\mathrm{T}}_2^{\ast } $$ quantification, respectively, and a contrast dynamics dimension for capturing contrast kinetics. The derived pixel-wise T 1 / T 2 * $$ {\mathrm{T}}_1/{\mathrm{T}}_2^{\ast } $$ time series are converted into contrast concentration-time curves for calculation of kinetic metrics. The technique was assessed for its agreement with reference methods in T 1 $$ {\mathrm{T}}_1 $$ and T 2 * $$ {\mathrm{T}}_2^{\ast } $$ measurements in eight healthy subjects and, in three of them, inter-session repeatability of permeability and leakage-insensitive perfusion parameters. Its feasibility was also demonstrated in four patients with brain tumors. RESULTS: MT-DICE T 1 / T 2 * $$ {\mathrm{T}}_1/{\mathrm{T}}_2^{\ast } $$ values of normal gray matter and white matter were in excellent agreement with reference values (intraclass correlation coefficients = 0.860/0.962 for gray matter and 0.925/0.975 for white matter ). Both permeability and perfusion parameters demonstrated good to excellent intersession agreement with the lowest intraclass correlation coefficients at 0.694. Contrast kinetic parameters in all healthy subjects and patients were within the literature range. CONCLUSION: Based on dynamic T 1 / T 2 * $$ {\mathrm{T}}_1/{\mathrm{T}}_2^{\ast } $$ mapping, MT-DICE allows for simultaneous quantification of permeability and leakage-insensitive perfusion metrics with a single-dose contrast injection.


Subject(s)
Contrast Media , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Perfusion , Brain/diagnostic imaging , Brain/pathology , Permeability
13.
Magn Reson Med ; 90(4): 1672-1681, 2023 10.
Article in English | MEDLINE | ID: mdl-37246485

ABSTRACT

PURPOSE: To develop a deep learning method to synthesize conventional contrast-weighted images in the brain from MR multitasking spatial factors. METHODS: Eighteen subjects were imaged using a whole-brain quantitative T1 -T2 -T1ρ MR multitasking sequence. Conventional contrast-weighted images consisting of T1 MPRAGE, T1 gradient echo, and T2 fluid-attenuated inversion recovery were acquired as target images. A 2D U-Net-based neural network was trained to synthesize conventional weighted images from MR multitasking spatial factors. Quantitative assessment and image quality rating by two radiologists were performed to evaluate the quality of deep-learning-based synthesis, in comparison with Bloch-equation-based synthesis from MR multitasking quantitative maps. RESULTS: The deep-learning synthetic images showed comparable contrasts of brain tissues with the reference images from true acquisitions and were substantially better than the Bloch-equation-based synthesis results. Averaging on the three contrasts, the deep learning synthesis achieved normalized root mean square error = 0.184 ± 0.075, peak SNR = 28.14 ± 2.51, and structural-similarity index = 0.918 ± 0.034, which were significantly better than Bloch-equation-based synthesis (p < 0.05). Radiologists' rating results show that compared with true acquisitions, deep learning synthesis had no notable quality degradation and was better than Bloch-equation-based synthesis. CONCLUSION: A deep learning technique was developed to synthesize conventional weighted images from MR multitasking spatial factors in the brain, enabling the simultaneous acquisition of multiparametric quantitative maps and clinical contrast-weighted images in a single scan.


Subject(s)
Deep Learning , Humans , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Neural Networks, Computer , Image Processing, Computer-Assisted/methods
14.
J Cardiovasc Magn Reson ; 25(1): 4, 2023 01 30.
Article in English | MEDLINE | ID: mdl-36710360

ABSTRACT

BACKGROUND: This study aimed to compare the coronary plaque characterization by cardiovascular magnetic resonance (CMR) and near-infrared spectroscopy (NIRS)-intravascular ultrasound (IVUS) (NIRS-IVUS), and to determine whether pre-percutaneous coronary intervention (PCI) evaluation using CMR identifies high-intensity plaques (HIPs) at risk of peri-procedural myocardial infarction (pMI). Although there is little evidence in comparison with NIRS-IVUS findings, which have recently been shown to identify vulnerable plaques, we inferred that CMR-derived HIPs would be associated with vulnerable plaque features identified on NIRS-IVUS. METHODS: 52 patients with stable coronary artery disease who underwent CMR with non-contrast T1-weighted imaging and PCI using NIRS-IVUS were studied. HIP was defined as a signal intensity of the coronary plaque-to-myocardial signal intensity ratio (PMR) ≥ 1.4, which was measured from the data of CMR images. We evaluated whether HIPs were associated with the NIRS-derived maximum 4-mm lipid-core burden index (maxLCBI4mm) and plaque morphology on IVUS, and assessed the incidence and predictor of pMI defined by the current Universal Definition using high-sensitive cardiac troponin-T. RESULTS: Of 62 lesions, HIPs were observed in 30 lesions (48%). The HIP group had a significantly higher remodeling index, plaque burden, and proportion of echo-lucent plaque and maxLCBI4mm ≥ 400 (known as large lipid-rich plaque [LRP]) than the non-HIP group. The correlation between the maxLCBI4mm and PMR was significantly positive (r = 0.51). In multivariable logistic regression analysis for prediction of HIP, NIRS-derived large LRP (odds ratio [OR] = 5.41; 95% confidence intervals [CIs] 1.65-17.8, p = 0.005) and IVUS-derived echo-lucent plaque (OR = 5.12; 95% CIs 1.11-23.6, p = 0.036) were strong independent predictors. Furthermore, pMI occurred in 14 of 30 lesions (47%) with HIP, compared to only 5 of 32 lesions (16%) without HIP (p = 0.005). In multivariable logistic regression analysis for prediction of incidence of pMI, CMR-derived HIP (OR = 5.68; 95% CIs 1.53-21.1, p = 0.009) was a strong independent predictor, but not NIRS-derived large LRP and IVUS-derived echo-lucent plaque. CONCLUSIONS: There is an important relationship between CMR-derived HIP and NIRS-derived large LRP. We also confirmed that non-contrast T1-weighted CMR imaging is useful for characterization of vulnerable plaque features as well as for pre-PCI risk stratification. Trial registration The ethics committee of Juntendo Clinical Research and Trial Center approved this study on January 26, 2021 (Reference Number 20-313).


Subject(s)
Coronary Artery Disease , Magnetic Resonance Spectroscopy , Plaque, Atherosclerotic , Spectroscopy, Near-Infrared , Ultrasonography, Interventional , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Lipids/analysis , Magnetic Resonance Spectroscopy/methods , Myocardial Infarction/epidemiology , Percutaneous Coronary Intervention/adverse effects , Plaque, Atherosclerotic/diagnostic imaging , Predictive Value of Tests , Prospective Studies , Spectroscopy, Near-Infrared/methods , Ultrasonography, Interventional/methods
15.
Int J Mol Sci ; 25(1)2023 Dec 20.
Article in English | MEDLINE | ID: mdl-38203254

ABSTRACT

Accurate staging of bladder cancer assists in identifying optimal treatment (e.g., transurethral resection vs. radical cystectomy vs. bladder preservation). However, currently, about one-third of patients are over-staged and one-third are under-staged. There is a pressing need for a more accurate staging modality to evaluate patients with bladder cancer to assist clinical decision-making. We hypothesize that MRI/RNA-seq-based radiogenomics and artificial intelligence can more accurately stage bladder cancer. A total of 40 magnetic resonance imaging (MRI) and matched formalin-fixed paraffin-embedded (FFPE) tissues were available for analysis. Twenty-eight (28) MRI and their matched FFPE tissues were available for training analysis, and 12 matched MRI and FFPE tissues were used for validation. FFPE samples were subjected to bulk RNA-seq, followed by bioinformatics analysis. In the radiomics, several hundred image-based features from bladder tumors in MRI were extracted and analyzed. Overall, the model obtained mean sensitivity, specificity, and accuracy of 94%, 88%, and 92%, respectively, in differentiating intra- vs. extra-bladder cancer. The proposed model demonstrated improvement in the three matrices by 17%, 33%, and 25% and 17%, 16%, and 17% as compared to the genetic- and radiomic-based models alone, respectively. The radiogenomics of bladder cancer provides insight into discriminative features capable of more accurately staging bladder cancer. Additional studies are underway.


Subject(s)
Artificial Intelligence , Urinary Bladder Neoplasms , Humans , RNA-Seq , Urinary Bladder Neoplasms/diagnostic imaging , Urinary Bladder Neoplasms/genetics , Magnetic Resonance Imaging , Muscles
16.
Radiology ; 302(3): 557-565, 2022 03.
Article in English | MEDLINE | ID: mdl-34904874

ABSTRACT

Background The histologic nature of coronary high-intensity plaques (HIPs) at T1-weighted MRI in patients with stable coronary artery disease remains to be fully understood. Coronary atherosclerosis T1-weighted characterization (CATCH) enables HIP detection by simultaneously acquiring dark-blood plaque and bright-blood anatomic reference images. Purpose To determine if intraplaque hemorrhage (IPH) or lipid is the predominant substrate of HIPs on T1-weighted images by comparing CATCH MRI scans with findings on near-infrared spectroscopy (NIRS) intravascular US (IVUS) images. Materials and Methods This study retrospectively included consecutive patients who underwent CATCH MRI before NIRS IVUS between December 2019 and February 2021 at two facilities. At MRI, HIP was defined as plaque-to-myocardium signal intensity ratio of at least 1.4. The presence of an echolucent zone at IVUS (reported to represent IPH) was recorded. NIRS was used to determine the lipid component of atherosclerotic plaque. Lipid core burden index (LCBI) was calculated as the fraction of pixels with a probability of lipid-core plaque greater than 0.6 within a region of interest. Plaque with maximum LCBI within any 4-mm-long segment (maxLCBI4 mm) greater than 400 was regarded as lipid rich. Multivariable analysis was performed to evaluate NIRS IVUS-derived parameters associated with HIPs. Results There were 205 plaques analyzed in 95 patients (median age, 74 years; interquartile range [IQR], 67-78 years; 75 men). HIPs (n = 42) at MRI were predominantly associated with an echolucent zone at IVUS (79% [33 of 42] vs 8.0% [13 of 163], respectively; P < .001) and a higher maxLCBI4 mm at NIRS (477 [IQR, 258-738] vs 232 [IQR, 59-422], respectively; P < .001) than non-HIPs. In the multivariable model, HIPs were independently associated with an echolucent zone (odds ratio, 24.5; 95% CI: 9.3, 64.7; P < .001), but not with lipid-rich plaque (odds ratio, 2.0; 95% CI: 0.7, 5.4; P = .20). Conclusion The predominant substrate of T1-weighed MRI-defined high-intensity plaques in stable coronary artery disease was intraplaque hemorrhage, not lipid. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Stuber in this issue.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Magnetic Resonance Imaging/methods , Plaque, Atherosclerotic/diagnostic imaging , Spectroscopy, Near-Infrared/methods , Ultrasonography, Interventional/methods , Aged , Female , Humans , Male , Retrospective Studies
17.
Magn Reson Med ; 87(1): 102-119, 2022 01.
Article in English | MEDLINE | ID: mdl-34398991

ABSTRACT

PURPOSE: To address head motion in brain MRI with a novel motion-resolved imaging framework, with application to motion-robust quantitative multiparametric mapping. METHODS: MR multitasking conceptualizes the underlying multiparametric image in the presence of motion as a multidimensional low-rank tensor. By incorporating a motion-state dimension into the parameter dimensions and introducing unsupervised motion-state binning and outlier motion reweighting mechanisms, the brain motion can be readily resolved for motion-robust quantitative imaging. A numerical motion phantom was used to simulate different discrete and periodic motion patterns under various translational and rotational scenarios, as well as investigate the sensitivity to exceptionally small and large displacements. In vivo brain MRI was performed to also evaluate different real discrete and periodic motion patterns. The effectiveness of motion-resolved imaging for simultaneous T1 /T2 /T1ρ mapping in the brain was investigated. RESULTS: For all 14 simulation scenarios of small, intermediate, and large motion displacements, the motion-resolved approach produced T1 /T2 /T1ρ maps with less absolute difference errors against the ground truth, lower RMSE, and higher structural similarity index measure of T1 /T2 /T1ρ measurements compared to motion removal, and no motion handling. For in vivo experiments, the motion-resolved approach produced T1 /T2 /T1ρ maps with the best image quality free from motion artifacts under random discrete motion, tremor, periodic shaking, and nodding patterns compared to motion removal and no motion handling. The proposed method also yielded T1 /T2 /T1ρ measurement distributions closest to the motion-free reference, with minimal measurement bias and variance. CONCLUSION: Motion-resolved quantitative brain imaging is achieved with multitasking, which is generalizable to various head motion patterns without explicit need for registration-based motion correction.


Subject(s)
Brain , Magnetic Resonance Imaging , Artifacts , Brain/diagnostic imaging , Image Processing, Computer-Assisted , Motion , Phantoms, Imaging
18.
Magn Reson Med ; 87(5): 2363-2371, 2022 05.
Article in English | MEDLINE | ID: mdl-34843114

ABSTRACT

PURPOSE: To perform fast 3D steady-state CEST (ss-CEST) imaging using MR Multitasking. METHODS: A continuous acquisition sequence with repetitive ss-CEST modules was developed. Each ss-CEST module contains a single-lobe Gaussian saturation pulse, followed by a spoiler gradient and eight FLASH readouts (one "training line" + seven "imaging lines"). Three-dimensional Cartesian encoding was used for k-space acquisition. Reconstructed CEST images were quantified with four-pool Lorentzian fitting. RESULTS: Steady-state CEST with whole-brain coverage was performed in 5.6 s per saturation frequency offset at the spatial resolution of 1.7 × 1.7 × 3.0 mm3 . The total scan time was 5.5 min for 55 different frequency offsets. Quantitative CEST maps from multipool fitting showed consistent image quality across the volume. CONCLUSION: Three-dimensional ss-CEST with whole-brain coverage can be done at 3 T within 5.5 min using MR Multitasking.


Subject(s)
Brain , Magnetic Resonance Imaging , Brain/diagnostic imaging , Magnetic Resonance Imaging/methods , Normal Distribution
19.
Magn Reson Med ; 87(1): 488-495, 2022 01.
Article in English | MEDLINE | ID: mdl-34374468

ABSTRACT

PURPOSE: To develop a deep-learning-based method to quantify multiple parameters in the brain from conventional contrast-weighted images. METHODS: Eighteen subjects were imaged using an MR Multitasking sequence to generate reference T1 and T2 maps in the brain. Conventional contrast-weighted images consisting of T1 MPRAGE, T1 GRE, and T2 FLAIR were acquired as input images. A U-Net-based neural network was trained to estimate T1 and T2 maps simultaneously from the contrast-weighted images. Six-fold cross-validation was performed to compare the network outputs with the MR Multitasking references. RESULTS: The deep-learning T1 /T2 maps were comparable with the references, and brain tissue structures and image contrasts were well preserved. A peak signal-to-noise ratio >32 dB and a structural similarity index >0.97 were achieved for both parameter maps. Calculated on brain parenchyma (excluding CSF), the mean absolute errors (and mean percentage errors) for T1 and T2 maps were 52.7 ms (5.1%) and 5.4 ms (7.1%), respectively. ROI measurements on four tissue compartments (cortical gray matter, white matter, putamen, and thalamus) showed that T1 and T2 values provided by the network outputs were in agreement with the MR Multitasking reference maps. The mean differences were smaller than ± 1%, and limits of agreement were within ± 5% for T1 and within ± 10% for T2 after taking the mean differences into account. CONCLUSION: A deep-learning-based technique was developed to estimate T1 and T2 maps from conventional contrast-weighted images in the brain, enabling simultaneous qualitative and quantitative MRI without modifying clinical protocols.


Subject(s)
Deep Learning , Brain/diagnostic imaging , Gray Matter , Humans , Magnetic Resonance Imaging , Signal-To-Noise Ratio
20.
Magn Reson Med ; 88(4): 1748-1763, 2022 10.
Article in English | MEDLINE | ID: mdl-35713184

ABSTRACT

PURPOSE: To develop a free-breathing, non-electrocardiogram technique for simultaneous myocardial T1 , T2 , T2 *, and fat-fraction (FF) mapping in a single scan. METHODS: The MR Multitasking framework is adapted to quantify T1 , T2 , T2 *, and FF simultaneously. A variable TR scheme is developed to preserve temporal resolution and imaging efficiency. The underlying high-dimensional image is modeled as a low-rank tensor, which allows accelerated acquisition and efficient reconstruction. The accuracy and/or repeatability of the technique were evaluated on static and motion phantoms, 12 healthy volunteers, and 3 patients by comparing to the reference techniques. RESULTS: In static and motion phantoms, T1 /T2 /T2 */FF measurements showed substantial consistency (R > 0.98) and excellent agreement (intraclass correlation coefficient > 0.93) with reference measurements. In human subjects, the proposed technique yielded repeatable T1 , T2 , T2 *, and FF measurements that agreed with those from references. CONCLUSIONS: The proposed free-breathing, non-electrocardiogram, motion-resolved Multitasking technique allows simultaneous quantification of myocardial T1 , T2 , T2 *, and FF in a single 2.5-min scan.


Subject(s)
Heart , Image Interpretation, Computer-Assisted , Heart/diagnostic imaging , Humans , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Motion , Myocardium , Phantoms, Imaging , Reproducibility of Results