Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Publication year range
1.
Mikrochim Acta ; 190(10): 378, 2023 09 06.
Article in English | MEDLINE | ID: mdl-37672131

ABSTRACT

The proof-of-concept of sensitive electrochemical immunoassay for the quantitative monitoring of human epidermal growth factor receptor 2 (HER2) is reported. The assay is carried out on iron nitrogen-doped carbon (FeNC) nanozyme-modified screen-printed carbon electrode using chronoamperometry. Introduction of target HER2 can induce the sandwiched immunoreaction between anti-HER2 monoclonal antibody-coated microplate and biotinylated anti-HER2 polyclonal antibody. Thereafter, streptavidin-glucose oxidase (GOx) conjugate is bonded to the detection antibody. Upon addition of glucose, 3,3',5,5'-tetramethylbenzidine (TMB) is oxidized through the produced H2O2 with the assistance of GOx and FeNC nanozyme. The oxidized TMB is determined via chronoamperometry. Experimental results revealed that electrochemical immunosensing system exhibited good amperometric response, and allowed the detection of target HER2 as low as 4.5 pg/mL. High specificity and long-term stability are acquired with FeNC nanozyme-based sensing strategy. Importantly, our system provides a new opportunity for protein diagnostics.


Subject(s)
Antibodies, Monoclonal , Hydrogen Peroxide , Humans , Carbon , Glucose Oxidase , Immunoassay
2.
ACS Sens ; 8(1): 317-325, 2023 01 27.
Article in English | MEDLINE | ID: mdl-36617728

ABSTRACT

This work presents a photocurrent-polarity-switching-based photoelectrochemical (PEC) biosensing platform for ultrasensitive detection of microRNA-21 (miR-21) through target-triggered catalytic hairpin assembly (CHA) for modulation of methylene blue (MB) and ferrocene (Fc) positional configurations using double-shelled Cu-doped ZnS nanocages (NCs)-Au nanoparticles (NPs) as photoactive materials. In the presence of miR-21, the assembly of MB-labeled HP1 and Fc-labeled HP2 leads to the generation of a large amount of double-stranded DNA (HP1-HP2), which pushes MB away from the electrode surface and brings Fc close to the electrode surface, resulting in effectively quenching the enhanced PEC signal to activate the photocurrent-polarity-switching system. Benefiting from the distance-controllable strategy, the designed PEC bioanalysis can effectively eliminate false-positive and false-negative signals due to the change of different signal expression patterns (from traditional the "signal-on" mode to the photocurrent-polarity-switching mode), thereby significantly improving the sensing specificity and sensitivity. The proposed PEC sensing system exhibited satisfying photocurrent responses toward target miR-21 within the working range from 1.0 fM to 1 nM at a low limit of detection (LOD) of 0.58 fM. More importantly, we demonstrated the successful integration of the proposed PEC biosensor with a handheld wireless device for instant detection of miR-21 concentrations in practical samples.


Subject(s)
Biosensing Techniques , Metal Nanoparticles , MicroRNAs , Gold , Biosensing Techniques/methods , Methylene Blue , Electrochemical Techniques/methods , MicroRNAs/analysis , Chromosomal Proteins, Non-Histone
SELECTION OF CITATIONS
SEARCH DETAIL