Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Database
Language
Journal subject
Publication year range
1.
BMC Ophthalmol ; 18(1): 315, 2018 Dec 10.
Article in English | MEDLINE | ID: mdl-30526537

ABSTRACT

BACKGROUND: Despite the potential usefulness of optical coherence tomography angiography in retinal and optic disc conditions, the reliability of the imaging modality remains unclear. This study set out to measure the microvascular density of macula and optic disc by mean of optical coherence tomography angiography and report the repeatability of the vessel density measurements. METHODS: Cross sectional observational cohort study. Subjects with normal eyes were recruited. Two sets of optical coherence tomography angiography images of macula and optic nerve head were acquired during one visit. Novel in-house developed software was used to count the pixels in each images and to compute the microvessel density of the macula and optic disc. Data were analysed to determine the measurement repeatability. RESULTS: A total of 176 eyes from 88 consecutive normal subjects were recruited. For macular images, the mean vessel density at superficial retina, deep retina, outer retina and choriocapillaries segment was OD 0.113 and OS 0.111, OD 0.239 and OS 0.230, OD 0.179 and OS 0.164, OD 0.237 and OS 0.215 respectively. For optic disc images, mean vessel density at vitreoretinal interface, radial peripapillary capillary, superficial nerve head and disc segment at the level of choroid were OD 0.084 and OS 0.085, OD 0.140 and OS 0.138, OD 0.216 and OS 0.209, OD 0.227 and OS 0.236 respectively. The measurement repeatability tests showed that the coefficient of variation of macular scans, for right and left eyes, ranged from 6.4 to 31.1% and 5.3 to 59.4%. Likewise, the coefficient of variation of optic disc scans, for right and left eyes, ranged from 14.3 to 77.4% and 13.5 to 75.3%. CONCLUSIONS: Optical coherence tomography angiography is a useful modality to visualise the microvasculature plexus of macula and optic nerve head. The vessel density measurement of macular scan by mean of optical coherence tomography angiography demonstrated good repeatability. The optic disc scan, on the other hand, showed a higher coefficient of variation indicating a lower measurement repeatability than macular scan. Interpretation of optical coherence tomography angiography should take into account test-retest repeatability of the imaging system. TRIAL REGISTRATION: National Healthcare Group Domain Specific Review Board ( NHG DSRB ) Singapore. DSRB Reference: 2015/00301.


Subject(s)
Macula Lutea/blood supply , Optic Disk/blood supply , Retinal Vessels/cytology , Adult , Cross-Sectional Studies , Female , Fluorescein Angiography/methods , Humans , Macula Lutea/diagnostic imaging , Male , Middle Aged , Optic Disk/diagnostic imaging , Reproducibility of Results , Tomography, Optical Coherence/methods
2.
Eur J Ophthalmol ; 32(4): NP26-NP29, 2022 Jul.
Article in English | MEDLINE | ID: mdl-33550831

ABSTRACT

PURPOSE: To report the clinical profile and effectiveness of oral doxycycline as a non-invasive treatment for glaucoma filtering surgery complications. METHOD: Prospective case series. RESULTS: Doxycycline is widely used in treating corneal melts, ocular surface diseases, meibomian gland disease, recurrent epithelial cell erosion, rosacea, and keratitis sicca. This prospective case series highlights the successful treatment of five patients with leaking blebs and conjunctiva erosion from glaucoma filtration surgery with the use of oral doxycycline. There was no adverse event reported in our cases. CONCLUSIONS: This study suggests that oral doxycycline may be a feasible non-surgical treatment modality due to its ability to inhibit collagenolysis, restore the Meibomian gland function, thereby stopping breakdown and promote conjunctival tissue healing.


Subject(s)
Filtering Surgery , Glaucoma , Trabeculectomy , Conjunctiva/surgery , Doxycycline/therapeutic use , Filtering Surgery/adverse effects , Glaucoma/drug therapy , Glaucoma/etiology , Glaucoma/surgery , Humans , Intraocular Pressure , Postoperative Complications/surgery , Reoperation , Retrospective Studies , Trabeculectomy/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL