ABSTRACT
OBJECTIVE: To determine the effect of Normosol™-R as compared to normal saline on the outcomes of acute kidney injury and the need for renal replacement therapy in the resuscitation phase of sepsis. DESIGN: Our study is a retrospective before-and-after cohort study. SETTING: The study occurred at a 700-bed tertiary academic level 1-trauma center. PATIENTS: A total of 1218 patients were enrolled through emergency department admissions. The normal saline (before) cohort was defined as the dates between 1 March and 30 September 2014 and the Normosol™-R (after) cohort was assessed from 1 March to 30 September 2015. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Intravenous fluid volumes received during the first 24 h, 72 h, and total hospital stays were compared. Sodium, chloride, potassium, and bicarbonate levels at 72 h were also compared. The medical coded diagnosis of acute kidney failure, need for renal replacement therapy, hospital LOS, ICU admission, ICU LOS, in-hospital mortality, and need for mechanical ventilation were all compared. There was no significant difference in intravenous fluid volumes between groups. Regression modelling controlling for baseline characteristics and 24-h fluid intake volume found no differences between groups for the primary outcomes of acute kidney injury (P = 0.99) and renal replacement therapy (P = 0.88). Patients in the Normosol™-R cohort were found to have a lower rate of hyperchloremia at 72 h post-admission (28% vs. 13%, P < 0.0001). There was a trend toward a decrease in the hospital and ICU LOS in the Normosol™-R cohort; however, the data were not statistically significant. CONCLUSIONS: This study was unable to detect any difference in outcomes between sepsis patients who received intravenous fluid resuscitation with either a balanced crystalloid (Normosol™-R) or normal saline, except for a decreased rate of hyperchloremia.
ABSTRACT
The effect of the conformation of a polymeric pseudostationary phase on performance and selectivity in electrokinetic chromatography was studied using an amphiphilic pH-responsive polymer that forms compact intramolecular aggregates (unimer micelles) at low pH and a more open conformation at high pH. The change in conformation was found to affect the electrophoretic mobility, retention, selectivity, and separation efficiency. The low-pH conformer has higher electrophoretic mobility and greater affinity for most solutes. The unimer micelle conformation was also found to provide a solvation environment more like that of micelles and other amphiphilic self-associative polymers studied previously. It was not possible to fully characterize the effect of conformation on efficiency, but very hydrophobic solutes with long alkyl chains appeared to migrate with better efficiency when the unimer micelle conformation was employed. The results imply that polymers with a carefully optimized lipophilic-hydrophilic balance that allow self-association will perform better as pseudostationary phases. In addition, the results show that electrokinetic chromatography is a useful method for determining the changes in solvation environment provided by stimuli-responsive polymers with changes in the conditions.