ABSTRACT
BACKGROUND: Five- to 10-year outcomes of a modular head-neck adapter system with ceramic heads in revision hip arthroplasty on large populations are still lacking. A registry study about modular adapter system with Delta ceramic head in revisions was designed, aiming to assess (1) the survival rates of the device, (2) the reasons for re-revisions of the device, and (3) a comparison to factory assembled titanium sleeve and Delta head cohort in revision hips. METHODS: Using a regional arthroplasty registry, we investigated the modular adapter system with a ceramic head in revision hips. Demographics, implant features, and reasons for revision were recorded. Survival rates and reasons for re-revision were assessed. The modular adapter system with the ceramic ball was compared to a factory-assembled ceramic titanium-sleeved head in revisions, acting as a control group. There were 354 revisions included at a mean follow-up of 5 years (range, 0 to 13). RESULTS: The 5- and 7-year survival rates were 87.9% and 86.9%, respectively. Dislocations (2.8%) and cup aseptic loosening (4.2%) were the 2 most frequent reasons for re-revision. No breakage of the adapter system or the ceramic head occurred. A femoral neck failed (0.3%). No implant features, offset (P = .088) or skirted (P = .870) tapers, impacted on failures. No differences between the 2 cohorts were found regarding survival rates (P = .696) and reasons for re-revision (dislocations, P = .983; cup aseptic loosening, P = .296). CONCLUSION: The modular head neck adapter system with a ceramic head seems to be a valid option in revisions at 5 and 7 years, without additional risk of implant breakage in this registry.
Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Titanium , Prosthesis Failure , Prosthesis Design , Reoperation , Registries , CeramicsABSTRACT
INTRODUCTION: The current strategy for modular neck failures in total hip arthroplasty (THA) is calibrated on CrCo neck failures. Stem revision is usually required, but the procedure is challenging and achieves modest outcomes (up to 20% of re-revisions at short-term). No study reports revision strategies and outcomes after Ti neck failures. Aims of the study were to evaluate: (1) demographic and implant features of the cohort to be revised, (2) intra-operative findings and surgical revision strategies and (3) clinical and radiological post-revision outcomes. MATERIALS AND METHODS: Hospital database was enquired about revisions due to Ti neck failures in primary THAs. Sixty-five revisions were enrolled (all with the same modular system). Neck exchange was attempted as the first-line treatment. Patients were clinically and radiographically evaluated after revision. RESULTS: The revision cohort encompassed fatigue neck fractures occurred 4.4 ± 2.6 years after THA: patients < 65 years and/or > 80 kg (98.5%) were predominant. Fifty-three neck exchanges were performed (81.5%). Eleven failures required stem revisions (16.9%), generally due to demanding neck extraction. Six complications occurred after neck exchange (11.3%), among them 2 acute infections requiring surgery (3.8%). Among stem revisions, one aseptic loosening and one neck re-fracture (18.5%) required re-revisions. At a mean follow-up of 7.1 ± 4 years, the neck exchange cohort achieved a mean HHS of 89.1 ± 6.3 (stem revisions: 84.1 ± 10.9). CONCLUSIONS: Revisions for Ti neck failures were predominantly performed due to fatigue fractures. In case of failures, neck exchange is a feasible procedure in most of the cases, with good outcomes at 7 years. LEVEL OF EVIDENCE: Level IV, retrospective case series.
Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis/adverse effects , Titanium , Retrospective Studies , Prosthesis Design , Reoperation , Prosthesis Failure , Treatment Outcome , Follow-Up StudiesABSTRACT
INTRODUCTION: Condylar constrained knee arthroplasties (CCKAs) and rotating hinge knee arthroplasties (RHKAs) achieved good outcomes in complex primary total knee arthroplasties (TKAs); however, long-term comparative studies are few. Using an arthroplasty registry, we sought to assess and compare in CCKAs and RHKAs: (1) the intra-operative rates of complications, (2) the survival rates, (3) the reasons for revision, and (4) the adjusted hazard ratios for failure. MATERIALS AND METHODS: 1432 constrained implants in primary TKAs performed for non-oncological indications were included: 703 RHKAs, 729 CCKAs. The two groups were comparable regarding age and gender. Kaplan-Meier curves were used to compare survival rates, multivariate analyses to assess the hazard ratios for failures. RESULTS: The mean follow-up was 4.1 years (range 0-16.3) for CCKAs and 6.8 years (0-18.1) for RHKAs. The intra/peri-operative complications were similar in both the cohorts, with similar rates of femoral and tibial fractures. 10-year implant survival rates were similar in both the cohorts (91.9%, CI 95% 89.2-93.9% in RHKAs; 93.4%, CI 95% 90.3-95.6% in CCKAs). Periprosthetic infection was the most common reason for revision in the two cohorts, followed by aseptic loosening. Breakage occurred in 3 RHKAs (0.4%). CCKAs and RHKAs had a similar distribution of revision causes. Males aged less than 60 had significantly more failures, regardless the constraint degree. Unstemmed CCKAs significantly failed more than RHKAs and stemmed CCKAs. CONCLUSIONS: Both modern CCKAs and RHKAs are viable long-term solutions in complex primary TKAs. More failures should be expected in males aged less than 60. LEVEL OF EVIDENCE: IV, Therapeutic study.
Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Male , Humans , Arthroplasty, Replacement, Knee/adverse effects , Knee Joint/surgery , Prosthesis Design , Reoperation/adverse effects , Prosthesis Failure , Treatment Outcome , Knee Prosthesis/adverse effects , Retrospective Studies , Follow-Up StudiesABSTRACT
BACKGROUND: Stem choice in total hip arthroplasty (THA) for hip dysplasia is still controversial. The aims of the study were to evaluate (1) which stem design provided the highest percentage of adequate reconstructions in THA for dysplasia and (2) any correlation between the reconstructions provided by the stems and the native femoral morphology. MATERIALS AND METHODS: 150 CT scans including 200 adult dysplastic hips were randomly selected. Using the 3D CT-based software Hip-Op for surgical planning, the native hip anatomy was studied. Then, a single wedge tapered stem, an anatomical stem and a conical tapered stem were simulated in every hip. An adequate reconstruction of hip biomechanics was obtained when combined anteversion, offset restoration, coronal and sagittal tilt, canal filling and leg lengthening were inside the normal ranges. RESULTS: Conical stems achieved the highest percentage of adequate reconstructions (87%, p < 0.0001). The anatomical stem was the worst performer. Single wedge and anatomical stem acceptability was mainly influenced by the combined anteversion. Stem anteversion was correlated with the femoral anteversion (fair correlation), the calcar femorale (fair) and the mediolateral femoral diameter at isthmus (poor). When the femoral anteversion was ≥ 25°, combined anteversion was very acceptable for the conical stem (99.2%), whereas the rate of acceptable combined anteversion for the single wedge tapered stem was 71.4%, and that for the anatomical stem was 51.6% (p < 0.0001). CONCLUSIONS: Stem choice in developmental hip dysplasia is mainly driven by appropriate combined anteversion, which is dependent on the coronal and axial femoral morphologies. As a rule of thumb, tapered stems are adequate when femoral anteversion is < 25°; conical stems should be adopted for higher anteversions. LEVEL OF EVIDENCE: IV.
Subject(s)
Arthroplasty, Replacement, Hip , Developmental Dysplasia of the Hip , Hip Dislocation, Congenital , Hip Prosthesis , Adult , Femur/anatomy & histology , Femur/diagnostic imaging , Femur/surgery , Hip Dislocation, Congenital/diagnostic imaging , Hip Dislocation, Congenital/surgery , Humans , Retrospective Studies , Software , Tomography, X-Ray ComputedABSTRACT
INTRODUCTION: Total hip arthroplasty (THA) is the standard procedure for post-traumatic osteoarthritis (OA) of the hip after acetabular fracture. However, it is not as simple as a primary THA, challenging the surgeon with anatomical deformity and intra and postoperative complications. In the current literature, there is a lack of studies reporting long-term results. May ceramic-on-ceramic (CoC) bearings provide good clinical and radiological outcomes at a long-term follow-up in patients undergoing THA following acetabular fracture? MATERIALS AND METHODS: We retrospectively analyzed 68 patients (mean age 47 years [range 22-75)] who underwent cementless modular neck stem THA, all implants CoC bearings (50 previously operatively treated and 18 non-operatively treated) after a specific CT study protocol at our Institute since 2000-2008. Clinical outcomes, prosthetic components' osseointegration, survival rate, and reasons for revision were analyzed. Minimum clinical and radiological follow-up was 10 years. RESULTS: HHS improved significantly after surgery from 37.6 ± 14.1 to 88.4 ± 11.6. 8 revision surgeries were performed, none for infection: we reported 2 stem aseptic loosening, 2 periprosthetic femoral fractures and 4 modular neck fractures. One implant noise (third-generation ceramic coupling) was described. Cup osseointegration was present (according to Moore the presence of at least 3 radiological criteria defines an effective osseointegration) in 67 patients (98.5%). After a 10 years follow-up, survival rate resulted 88.4%, sensibly higher than most of results reported in the current literature. CONCLUSION: The high survival rate may be related to CoC: no osteolysis and no infections were reported. Also acetabular cup loosening incidence was sensibly lower (1.47%) among loosening rate described by other authors. Clinical and radiological outcomes were decent, probably due to modular prosthesis design. Modular necks are a solution which can help achieving a proper functional reconstruction of the hip (offset, center of rotation), but should be avoided in young and overweight patients because of the high risk of fracture. CoC bearings in THAs in post-traumatic OA after acetabular fracture showed good results despite the fact that specific ceramic-related issues have to be considered.
Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip , Fractures, Bone/surgery , Hip Prosthesis , Osteoarthritis, Hip/surgery , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/instrumentation , Arthroplasty, Replacement, Hip/statistics & numerical data , Ceramics , Humans , Prosthesis Design , Retrospective Studies , Treatment OutcomeABSTRACT
OBJECTIVE: The aim of the study was to assess the safety, efficacy and feasibility of stapled transanal procedures performed by a new dedicated device, TST STARR Plus, for tailored transanal stapled surgery. METHODS: All the consecutive patients admitted to eight referral centres affected by prolapses with III-IV degrees haemorrhoids or obstructed defecation syndrome (ODS) with rectocele and/or rectal intussusception that underwent stapled transanal resection with TST STARR plus were included in the present study. Haemostatic stitches for bleeding of the suture line, specimen volume, operative time, hospital stay and perioperative complications were recorded. RESULTS: From 1 November 2012 to 31 March 2013, 160 consecutive patients (96 females) were enrolled in the study. In 94 patients, the prolapse was over the half of the circular anal dilator (CAD). The mean duration of the procedure was 25 min. The mean resected volume of the specimen was 13.3 cm(3), the mean hospital stay was 2.2 days. In 88 patients (55%), additional stitches on the suture line were needed (mean 2.1). Suture line dehiscence was reported in four cases, with intraoperative reinforcement. Bleeding was reported in seven patients (5%). Urgency after 30 days was reported in one patient. No major complication occurred. CONCLUSIONS: The new device seems to be safe and effective for a tailored approach to anorectal prolapse due to haemorrhoids or obstructed defecation.
Subject(s)
Constipation/surgery , Hemorrhoids/surgery , Intestinal Obstruction/surgery , Rectal Diseases/surgery , Surgical Stapling/instrumentation , Anal Canal/surgery , Defecation , Feasibility Studies , Female , Hemostatic Techniques , Humans , Length of Stay , Male , Operative Time , Pain/etiology , Patient Satisfaction , Prolapse , Surgical Stapling/adverse effects , SyndromeABSTRACT
Cementless primary stems in revision hip arthroplasties may be conservative options to preserve bone stock and provide adequate reconstruction of the hip biomechanics. However, there is still little evidence about indications, limitations, and outcomes. This narrative review showed that conventional standard stems were adopted in different revision settings, up to Paprosky IIIA grade bone defects. In cases of acceptable metaphyseal bone stock, when a scratch fit of at least 4 cm can be achieved, a conventional cementless stem may be an adequate solution. Mid-term clinical and radiographic outcomes and survival rates were similar to long revision stems, whereas complications, surgical time, and costs were lower among conventional stems. However, unsuitable contexts for conventional stems included canal diameters larger than 18 mm and failed revision stems with cortical weakening. Even short stems can be considered in revisions, in order to preserve bone stock and stay proximal to femoral remodeling zones and bone/cement plugs. Short stems were successfully adopted up to Paprosky IIIA bone defects, achieving mid-term survival rates not inferior to long revision stems. Ageing, osteoporosis, and intraoperative femoral fractures were the main negative prognostic factors. In very select cases, a downsizing technique (from longer to shorter stems) may be adopted to simplify the procedure and reduce complications.
ABSTRACT
BACKGROUND: There is a paucity of data regarding the post-operative influence of total hip arthroplasty (THA) on the axial and coronal alignments of the ipsilateral knee. A CT study was designed to assess the post-THA changes in axial and coronal knee alignments in low-grade dysplastic hips. METHODS: Forty Crowe I-II dysplastic hips in 37 patients were assessed: a pre-operative CT scan from the fourth lumbar vertebra to the tibial plateaus was compared to a similar post-operative CT scan performed after a minimum of 2 years after THA. RESULTS: THA implantation caused significant post-operative changes in terms of the rotation height (2 mm lowering; p = 0.003); center of rotation medialization (10 mm medialization; p < 0.001); femoral offset (11 mm increase; p < 0.001); femoral antetorsion (22° internal rotation; p < 0.001), and hip internal rotation (9° internal rotation; p < 0.001). The femoral axis angle deviated in the valgus (5.5° ± 1.1°, p < 0.001) and the mechanical lateral distal femoral angle deviated in the varus (86° ± 2.7°, p = 0.001). The pelvic-tibial alignment changed from 88.2° ± 11.7° to 96° ± 9.3° (p < 0.001). Patellar alignment was not influenced. CONCLUSIONS: In conclusion, THA imposes significant changes in low-grade dysplastic hips: all the modifications tend to neutralize the coronal alignment and, mostly, the rotational alignment, without substantial and durable variations of the patellofemoral joint. Large clinical trials should confirm whether radiological changes impact anterior knee pain and patellar stability.
ABSTRACT
Little is known about dynamic changes of femoral anatomy after total hip arthroplasty (THA), in particular about sagittal femoral bowing (SFB). A 3D CT study was designed to evaluate the chronological changes of SFB after cementless femoral stem implantation for primary THA. Ten patients who underwent unilateral primary THA with a cementless femoral stem, with 2 consecutive CT scans (extending from the fourth lumbar vertebra to the tibial plateaus), performed before THA and at least 3 years after THA, were enrolled. The 3D models of femurs were created using image segmentation software. Using the two CT scans, SFB values of the proximal and middle thirds were calculated on the replaced and untreated sides by two different observers. Eight anatomical stems and two conical stems were involved. The post-operative CT was performed at an average follow-up of 6.5 years after THA (range: 3-12.5). The measurements performed by the two observers did not differ in the proximal and middle regions. A significant difference between the pre-operative and post-operative SFB compared to the untreated side was found in the proximal femur segment (p = 0.004). Use of a cementless stem in THA induced chronological changes in SFB of the proximal femur, after a minimum timespan of 3 years.
ABSTRACT
BACKGROUND: Ceramic bearings are used in total hip arthroplasty due to their excellent wear behaviour and biocompatibility. The major concern related to their use is material brittleness, which significantly impacts on the risk of fracture of ceramic components. Fracture toughness improvement has contributed to the decrease in fracture rate, at least of the prosthetic head. However, the root cause behind these rare events is not fully understood. This study evaluated head fracture occurrence in a sizeable cohort of patients with fourth-generation ceramic-on-ceramic implants and described the circumstances reported by patients in the rare cases of head fracture. METHODS: The clinical survivorship of 29,495 hip prostheses, with fourth-generation ceramic bearings, was determined using data from a joint replacement registry. The average follow-up period was 5.2 years (range 0.1-15.6). Retrieval analysis was performed in one case for which the ceramic components were available. RESULTS: Clinical outcomes confirmed the extremely low fracture rate of fourth-generation ceramic heads: only two out of 29,495 heads fractured. The two fractures, both involving 36 mm heads, occurred without a concurrent or previous remarkable trauma. Considering the feature of the fractured head, a multi-stage crack growth mechanism has been hypothesized to occur following damage at the head-neck taper interface. CONCLUSIONS: Surgeons must continue to pay attention to the assembly of the femoral head: achieving a proper head seating on a clean taper is a prerequisite to decrease the risk of occurrence of any damage process within head-neck junction, which may cause high stress concentration at the contact surface, promoting crack nucleation and propagation even in toughened ceramics.
Subject(s)
Arthroplasty, Replacement, Hip , Fractures, Bone , Hip Prosthesis , Arthroplasty, Replacement, Hip/instrumentation , Ceramics , Femur Head , Hip Prosthesis/adverse effects , Humans , Prosthesis Design , Prosthesis FailureABSTRACT
PURPOSE: The aim is to compare the results of isolated hip arthroscopy in patients with borderline dysplasia with Lateral center edge angle (LCEA) between 18° and 25° with a control group of patients with normal LCEA (> 25°). METHODS: Fifty hip arthroscopies performed in 45 patients were retrospectively evaluated. Exclusion criteria were: age > 40, hip arthritis > grade 2 according to Tonnis classification, femoral head avascular necrosis, pediatric's orthopaedics conditions and true dysplasia with LCEA < 18°.Two groups were identified: group A with 15 hips with LCEA between 25° and 18° and Group control B made of 35 hips with LCEA > 25°. RESULTS: The groups were homogeneous for demography and pre-operative WOMAC and HOOS. Osteoplasty for CAM were performed in 100% of patients in both groups, only in 12 hips (34.4%) in group B we had both femoral and acetabular osteoplasty. Labral repair was performed in 86% of patients in group A, in 60% of patients in group B, capsular plication in 93% of group A, in 5% of case of group B. WOMAC and HOOS statically significant improved in both groups at final follow-up (24 months). No cases in both groups required conversion to total hip arthroplasty. Clinical outcomes of study group were comparable to the control group. CONCLUSION: Even if the present small series is not conclusive, we suggest isolated arthroscopic management of patients with FAI and LCEA between 18° and 25°, but capsular plication and careful labral management are strongly recommended. LEVEL OF EVIDENCE: Level IV.
ABSTRACT
Background: total hip replacement (THR) is a rare surgical option in children and adolescents with disabling hip diseases. The aim of this study is to report results from a retrospective cohort of patients aged 18 years or less who underwent cementless Ceramic-on-Ceramic (CoC) THR at a single institution, investigating clinical and radiographic outcomes, survival rates, and reasons for revision of the implants. Materials and methods: we queried the Registry of Prosthetic Orthopedic Implants (RIPO) to identify all children and adolescents undergoing THR between 2000 and 2019 at a single Institution. Inclusion criteria were patients undergoing cementless CoC THR, aged less than 18 years at surgery, followed for at least 2 years. Sixty-eight patients (74 hips) matched all the inclusion criteria and were enrolled in the study. We assessed the clinical and radiographic outcomes, the rate of complications, the survival rate, and reasons for revision of the implants. Results: The mean follow-up was 6.6 ± 4.4 years (range 2-20). The most frequent reason for THR was post-traumatic or chemotherapy-induced avascular necrosis (38%). The overall survival rate of the cohort was 97.6% (95% CI: 84.9-99.7%) at 5 years of follow-up, 94.4% (95% CI: 79.8-98.6%) at 10 years and 15 years of follow-up. Two THR in two patients (2.7%) required revision. With the numbers available, Cox regression analysis could not detect any significant interaction between preoperative or intraoperative variables and implant survivorship (p-value 0.242 to 0.989)." The average HOOS was 85 ± 14.3 (range 30.6-100). Overall, 23 patients (48%) reported excellent HOOS scores (>90 points), 21 patients (44%) reported acceptable HOOS scores (60-90 points) while 4 patients (8%) reported poor outcomes (<60 points). Twenty-one patients (43%) were regularly involved into moderate- to high-intensity sport activities (UCLA ≥ 6). Conclusions: Cementless CoC THR is a successful procedure in children and teenagers, having demonstrated high implant survivorship and low rates of complications and failure. A meticulous preoperative planning and implant selection is mandatory, to avoid implant malposition, which is the main reason of failure and revision in these cases. Further studies are needed to assess the impact of the THR on the psychosocial wellbeing of teenagers, as well as risks and benefits and cost-effectiveness in comparison to the hip preserving surgical procedures.