Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Echocardiography ; 41(1): e15698, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38284664

ABSTRACT

BACKGROUND: Transaortic valve implant (TAVI) is the treatment of choice for severe aortic stenosis (AS). Some patients develop prosthesis patient mismatch (PPM) after TAVI. It is challenging to determine which patients are at risk for clinical deterioration. METHODS: We retrospectively measured echocardiographic parameters of left ventricular (LV) morphology and function, prosthetic aortic valve effective orifice area (iEOA) and hemodynamics in 313 patients before and 1 year after TAVI. Our objective was to compare the change in echocardiographic parameters associated with left ventricular reverse modeling in subjects with and without PPM. Our secondary objective was to evaluate echo parameters associated with PPM and the relationship to patient functional status and survival post-TAVI. RESULTS: We found that 82 (26.2%) of subjects had moderate and 37 (11.8%) had severe PPM post-TAVI. There was less relative improvement in LVEF with PPM (1.9 ± 21.3% vs. 8.2 + 30.1%, p = .045). LV GLS also exhibited less relative improvement in those with PPM (13.4 + 34.1% vs. 30.9 + 73.3%, p = .012). NYHA functional class improved in 84.3% of subjects by one grade or more. Echocardiographic markers of PPM were worse in those without improvement in NYHA class (mean AT/ET was .29 vs. .27, p = .05; DVI was .46 vs. .51, p = .021; and iEOA was .8 cm/m2 vs. .9 cm/m2 , p = .025). There was no association with PPM and survival. CONCLUSIONS: There was no improvement in LVEF and less improvement in LV GLS in those with PPM post-TAVI. Echocardiographic markers of PPM were present in those with lack of improvement in NYHA functional class.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Retrospective Studies , Ventricular Remodeling , Treatment Outcome , Echocardiography
2.
Ann Cardiothorac Surg ; 13(3): 275-282, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38841084

ABSTRACT

Background: The desire of patients to avoid anticoagulation, together with the potential of valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR), have resulted in the increasing use of bioprosthetic valves for aortic valve replacement (AVR). While patient-prosthesis mismatch (PPM) is known to be an adverse risk after AVR, few studies have addressed the effect of PPM on valve durability. This study evaluates the role of valve size and hemodynamics on long term durability after AVR with a Magna bioprosthesis. Methods: We performed a retrospective, single-center evaluation of patients who underwent a surgical AVR procedure between June 2004 through December 2022 using the Magna bioprosthesis. Perioperative information and long-term follow-up data were sourced from the institution's Society for Thoracic Surgeons Adult Cardiac Surgery Registry and outcomes database. Cumulative incidence of freedom from reintervention were estimated accounting for competing events. Group comparisons used Gray's test. Results: Among 2,100 patients, the mean patient age was 69 years (range, 22-95 years), of whom 98% had native aortic valve disease, 32.5% had concomitant coronary bypass grafting, and 19% had mitral valve surgery. Median follow-up was 5.8 (1.9-9.4) years, during which 116 reinterventions were performed, including 74 explants and 42 VIV procedures. Nine hundred and twenty-eight patients died prior to reintervention. Incidence of all cause reintervention was 1.2%, 4.5%, and 11.7% at 5, 10, and 15 years, respectively. Smaller valve size was associated with worse survival (P<0.001), but not with reintervention. Higher mean gradient at implant was associated with increased late reintervention [sub-distribution hazard ratio: 1.016; 95% confidence interval (CI): 1.005 to 1.028; P=0.0047, n=1,661]. Conclusions: While reintervention rates are low for the Magna prosthesis at 15 years, the analysis is confounded by the competing risk of death. PPM, as reflected physiologically by elevated post-operative valve gradients, portends an increased risk of intervention. Further study is necessary to elucidate the mechanism of early stenosis in patients who progress to reintervention.

3.
Article in English | MEDLINE | ID: mdl-38950772

ABSTRACT

OBJECTIVE: Aortic root replacement requires construction of a composite valve-graft and reimplantation of coronary arteries. This study assessed the feasibility of valve-in-valve transcatheter aortic valve implantation after aortic root replacement. METHODS: A retrospective review was conducted on 74 consecutive patients who received a composite valve-graft at a single institution from 2019 to 2021. Forty patients had bioprosthetic valves with adequate postoperative gated computed tomographic angiography scans. Computational simulations of balloon and self-expanding transcatheter valve deployments were performed. The modeled coronary distances were compared with traditional, manually measured valve-to-coronary distances. RESULTS: There was a statistically significant difference in the modeled versus manual measurements of valve to coronary distances for all patients regardless of valve type or coronary artery analyzed (P < .05). Most patients are low risk for coronary obstruction per 3-dimensional modeling, including those with a valve-to-coronary distance <4 mm. Only 1 patient (2.5%) was at risk for coronary obstruction for the left coronary artery using a balloon valve. No other valve combination was considered high risk of coronary obstruction. Five patients (12.5%) were at risk for possible valve stent deformation at the outflow, due to angulation at the graft anastomosis. CONCLUSIONS: Following aortic root replacement, all patients were candidates for valve-in-valve procedure using 1 or both types of transcatheter heart valves. Self-expanding valves may be at higher risk for stent frame deformation at graft anastomotic lines and balloon-expandable valves may be at higher risk of coronary obstruction.

4.
JACC Asia ; 4(4): 292-302, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38660112

ABSTRACT

Background: Sex-related disparities in clinical outcomes following transcatheter aortic valve replacement (TAVR) and the impact of sex on clinical outcomes after TAVR among different racial groups are undetermined. Objectives: This study assessed whether sex-specific differences in baseline clinical and anatomical characteristics affect clinical outcomes after TAVR and investigated the impact of sex on clinical outcomes among different racial groups. Methods: The TP-TAVR (Trans-Pacific TAVR) registry is a multinational cohort study of patients with severe aortic stenosis who underwent TAVR at 2 major centers in the United States and 1 major center in South Korea. The primary outcome was a composite of death from any cause, stroke, or rehospitalization after 1 year. Results: The incidence of the primary composite outcome was not significantly different between sexes (27.9% in men vs 28% in women; adjusted HR: 0.97; 95% CI: 0.79-1.20). This pattern was consistent in Asian (23.5% vs 23.3%; adjusted HR: 0.99; 95% CI: 0.69-1.41) and non-Asian (30.8% vs 31.6%; adjusted HR: 0.95; 95% CI: 0.72-1.24) cohorts, without a significant interaction between sex and racial group (P for interaction = 0.74). The adjusted risk for all-cause mortality was similar between sexes, regardless of racial group. However, the adjusted risk of stroke was significantly lower in male patients than in female patients, which was more prominent in the non-Asian cohort. Conclusions: Despite significantly different baseline and procedural characteristics, there were no sex-specific differences in the adjusted 1-year rates of primary composite outcomes and all-cause mortality, regardless of different racial groups. (Transpacific TAVR registry [TP-TAVR]; NCT03826264).

SELECTION OF CITATIONS
SEARCH DETAIL