Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Cytotherapy ; 26(6): 567-578, 2024 06.
Article in English | MEDLINE | ID: mdl-38493403

ABSTRACT

BACKGROUND AIMS: The CliniMACS Prodigy closed system is widely used for the manufacturing of chimeric antigen receptor T cells (CAR-T cells). Our study presents an extensive immunophenotypic and functional characterization and comparison of the properties of anti-CD19 CAR-T cell products obtained during long (11 days) and short (7 days) manufacturing cycles using the CliniMACS Prodigy system, as well as cell products manufactured from different donor sources of T lymphocytes: from patients, from patients who underwent HSCT, and from haploidentical donors. We also present the possibility of assessing the efficiency of transduction by an indirect method. METHODS: Seventy-six CD19 CAR-T cell products were manufactured using the CliniMACS Prodigy automated system. Immunophenotypic properties, markers of cell activation and exhaustion, antitumor, anti-CD19 specific activity in vitro of the manufactured cell products were evaluated. As an indirect method for assessing the efficiency of transduction, we used the method of functional assessment of cytokine secretion and expression of the CD107a marker after incubation of CAR-T cells with tumor targets. RESULTS: The CliniMACS Prodigy platform can produce a product of CD19 CAR-T cells with sufficient cell expansion (4.6 × 109 cells-median for long process [LP] and 1.6 × 109-for short process [SP]), transduction efficiency (43.5%-median for LP and 41.0%-for SP), represented mainly by T central memory cell population, with low expression of exhaustion markers, and with high specific antitumor activity in vitro. We did not find significant differences in the properties of the products obtained during the 7- and 11-day manufacturing cycles, which is in favor of reducing the duration of production to 7 days, which may accelerate CAR-T therapy. We have shown that donor sources for CAR-T manufacturing do not significantly affect the composition and functional properties of the cell product. CONCLUSIONS: This study demonstrates the possibility of using the CliniMACS Prodigy system with a shortened 7-day production cycle to produce sufficient amount of functional CAR-T cells. CAR transduction efficiency can be measured indirectly via functional assays.


Subject(s)
Antigens, CD19 , Immunotherapy, Adoptive , Receptors, Chimeric Antigen , T-Lymphocytes , Humans , Antigens, CD19/immunology , Immunotherapy, Adoptive/methods , Receptors, Chimeric Antigen/metabolism , Receptors, Chimeric Antigen/immunology , T-Lymphocytes/immunology , T-Lymphocytes/metabolism , Tissue Donors , Lymphocyte Activation , Immunophenotyping/methods
2.
Biochemistry (Mosc) ; 87(11): 1268-1276, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36509724

ABSTRACT

It has recently been shown that combination of arrestin and recoverin can serve as an effective urinary biomarker for renal cell carcinoma with sensitivity and specificity of over 92%. In this work, we studied the possibility of detecting these antigens in the urine in other urological oncological diseases - bladder cancer (BC) and prostate cancer (PCa). Urine samples from 40 BC patients and 40 PCa patients were analyzed using an ultrasensitive microarray immunoassay with a detection limit of 0.1 pg/ml. It was shown that in BC the sensitivity of determining combination of arrestin with recoverin is 58% (AUC 0.76, 95% CI 0.66-0.86), while in PCa it is 60% (AUC 0.7, 95% CI 0.68-0.88). It has been established that in patients with bladder and prostate cancer who had a positive test, these antigens are not detected in 90% of cases after removal of the tumor. In the future, the obtained results could become the basis for developing new approaches for timely detection of relapses of such diseases and treatment control, as well as for the development of new diagnostic methods.


Subject(s)
Prostatic Neoplasms , Urinary Bladder Neoplasms , Male , Humans , Urinary Bladder , Biomarkers, Tumor , Urinary Bladder Neoplasms/diagnosis , Prostatic Neoplasms/diagnosis , Sensitivity and Specificity , Antigens, Neoplasm
3.
Biochemistry (Mosc) ; 87(7): 658-666, 2022 Jul.
Article in English | MEDLINE | ID: mdl-36154884

ABSTRACT

Renal cell carcinoma (RCC) is the most common urological malignancy with a high mortality and low detection rate. One of the approaches to improving its diagnostics may be the search for new non-invasive biomarkers in liquid biopsy and development of more sensitive methods for their detection. Cancer-retina antigens, which are known to be aberrantly expressed in malignant tumors, are present in liquid biopsy at extremely low concentrations. Using the developed multiplex immunoassay with a detection limit of 0.1 pg/ml, urine and serum samples of 89 patients with RCC and 50 non-cancer patients were examined for the presence of cancer-retina antigens (arrestin, recoverin, rhodopsin kinase, and transducin); the difference between the RCC and control groups was evaluated with the χ2 test. The results showed high diagnostic efficiency of a combination of arrestin and recoverin: at a threshold of 0.1 pg/ml, the sensitivity was 96%, specificity 92%, and AUC = 0.96 (95% confidence interval, 0.93-0.99). Seven days after nephrectomy, the concentration of the antigens returned to the level characteristic of the control group. Therefore, arrestin in a combination with recoverin can serve as a diagnostic non-invasive urinary biomarker of RCC.


Subject(s)
Carcinoma, Renal Cell , Kidney Neoplasms , Arrestins , Biomarkers, Tumor , Carcinoma, Renal Cell/diagnosis , Carcinoma, Renal Cell/pathology , G-Protein-Coupled Receptor Kinase 1 , Humans , Kidney Neoplasms/diagnosis , Kidney Neoplasms/pathology , Recoverin , Retina , Transducin
4.
Anal Chem ; 93(2): 1126-1134, 2021 01 19.
Article in English | MEDLINE | ID: mdl-33305941

ABSTRACT

Among the key issues that are commonly associated with the development of microarray-based assays are nonspecific binding and diffusion constraints. Here we present a novel strategy addressing both of these challenges simultaneously. The essence of the method consists in blocking the microarray surface with a blocking agent containing a perfluoroalkyl chain and a disulfide linker. The resulting surface is hydrophobic, and no immiscible liquid layer remains on it upon cyclically draining and replenishing the sample solution, ensuring an efficient mass transfer of an analyte onto a microarray. Prior to the signal detection procedure, disulfide bonds are chemically cleaved, and the perfluoroalkyl chains are removed from the microarray surface along with nonspecifically adsorbed proteins, resulting in extremely low background. Using conventional fluorescent detection, we show a 30-fold increase in signal/background ratio compared to a common epoxy-modified glass substrate. The combination of this technique with magnetic beads detection results in a simple and ultrasensitive cholera toxin (CT) immunoassay. The limit of detection (LOD) is 1 fM, which is achieved with an analyte binding time of 1 h. Efficient mass transfer provides highly sensitive detection of whole virus particles despite their low diffusion coefficient. The achieved LOD for vaccinia virus is 104 particles in 1 mL of sample. Finally, we have performed for the first time the simultaneous detection of whole virus and CT protein biomarker in a single assay. The developed technique can be used for multiplex detection of trace amounts of pathogens of various natures.


Subject(s)
Cholera Toxin/analysis , Cystine/analogs & derivatives , Fluorescent Antibody Technique , Immunoassay , Protein Array Analysis , Cholera Toxin/metabolism , Cystine/chemical synthesis , Cystine/chemistry , Molecular Structure , Vaccinia virus/enzymology , Vaccinia virus/isolation & purification
5.
Anal Chem ; 91(17): 11209-11214, 2019 09 03.
Article in English | MEDLINE | ID: mdl-31361475

ABSTRACT

We present a multiplex microarray-based assay of DNA fragments, which allows the detection of less than 10000 DNA fragments in a sample of 100 µL (corresponding to ∼0.1 fM analyte concentration) in less than 5 min. High speed and sensitivity are due to three main features of the assay. First, biotinylated adapter oligonucleotides are hybridized to the DNA fragment. Second, it is electrophoretically concentrated from the sample onto the microarray. Third, biotin labels are detected by scanning the microarray surface with streptavidin-coated magnetic beads. Prior to analysis, dsDNA fragments and genomic DNA samples were first denatured and then annealed in the presence of blocking oligonucleotides, generating ssDNA fragments capable of hybridizing with oligonucleotide probes on the microarray. The multiplexity of the assay system was demonstrated by the simultaneous detection of the genomic DNAs of three microorganisms: E. coli, B. cereus, and M. neoaurum.


Subject(s)
DNA, Bacterial/genetics , Oligonucleotide Array Sequence Analysis , Bacillus cereus/genetics , Escherichia coli/genetics , Mycobacterium/genetics
6.
Sci Rep ; 11(1): 7827, 2021 04 09.
Article in English | MEDLINE | ID: mdl-33837223

ABSTRACT

Humans recognize individual faces regardless of variation in the facial view. The view-tuned face neurons in the inferior temporal (IT) cortex are regarded as the neural substrate for view-invariant face recognition. This study approximated visual features encoded by these neurons as combinations of local orientations and colors, originated from natural image fragments. The resultant features reproduced the preference of these neurons to particular facial views. We also found that faces of one identity were separable from the faces of other identities in a space where each axis represented one of these features. These results suggested that view-invariant face representation was established by combining view sensitive visual features. The face representation with these features suggested that, with respect to view-invariant face representation, the seemingly complex and deeply layered ventral visual pathway can be approximated via a shallow network, comprised of layers of low-level processing for local orientations and colors (V1/V2-level) and the layers which detect particular sets of low-level elements derived from natural image fragments (IT-level).


Subject(s)
Facial Recognition/physiology , Recognition, Psychology/physiology , Temporal Lobe/physiology , Visual Cortex/physiology , Visual Pathways/physiology , Animals , Brain Mapping , Face , Macaca fuscata , Nerve Net/physiology , Neurons/physiology
7.
Front Mol Biosci ; 7: 620687, 2020.
Article in English | MEDLINE | ID: mdl-33659273

ABSTRACT

The search for new diagnostic tests for cancer or ways to improve existing tests is primarily driven by the desire to identify the disease as early as possible. In this report, we summarize the current knowledge of the most promising diagnostic protein bladder cancer (BC) markers reported over the last decade. Unfortunately, analysis of published data suggests that a reliable, highly sensitive biomarker test-system based on ELISA for detecting BC has not yet been developed. The use of more sensitive assays to detect ultra-low concentrations of biomarkers not available for ELISA, could be very beneficial. Based on the literature and pilot experimental data, we conclude that a highly sensitive immunoassay using microarrays and magnetic labels, could be an effective and cheap technique suitable for the detection of diagnostically relevant BC biomarkers.

SELECTION OF CITATIONS
SEARCH DETAIL