Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 158
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Lancet ; 402(10410): 1329-1337, 2023 Oct 14.
Article in English | MEDLINE | ID: mdl-37647928

ABSTRACT

BACKGROUND: The International Liaison Committee on Resuscitation has called for a randomised trial of delivery to a cardiac arrest centre. We aimed to assess whether expedited delivery to a cardiac arrest centre compared with current standard of care following resuscitated cardiac arrest reduces deaths. METHODS: ARREST is a prospective, parallel, multicentre, open-label, randomised superiority trial. Patients (aged ≥18 years) with return of spontaneous circulation following out-of-hospital cardiac arrest without ST elevation were randomly assigned (1:1) at the scene of their cardiac arrest by London Ambulance Service staff using a secure online randomisation system to expedited delivery to the cardiac catheter laboratory at one of seven cardiac arrest centres or standard of care with delivery to the geographically closest emergency department at one of 32 hospitals in London, UK. Masking of the ambulance staff who delivered the interventions and those reporting treatment outcomes in hospital was not possible. The primary outcome was all-cause mortality at 30 days, analysed in the intention-to-treat (ITT) population excluding those with unknown mortality status. Safety outcomes were analysed in the ITT population. The trial was prospectively registered with the International Standard Randomised Controlled Trials Registry, 96585404. FINDINGS: Between Jan 15, 2018, and Dec 1, 2022, 862 patients were enrolled, of whom 431 (50%) were randomly assigned to a cardiac arrest centre and 431 (50%) to standard care. 20 participants withdrew from the cardiac arrest centre group and 19 from the standard care group, due to lack of consent or unknown mortality status, leaving 411 participants in the cardiac arrest centre group and 412 in the standard care group for the primary analysis. Of 822 participants for whom data were available, 560 (68%) were male and 262 (32%) were female. The primary endpoint of 30-day mortality occurred in 258 (63%) of 411 participants in the cardiac arrest centre group and in 258 (63%) of 412 in the standard care group (unadjusted risk ratio for survival 1·00, 95% CI 0·90-1·11; p=0·96). Eight (2%) of 414 patients in the cardiac arrest centre group and three (1%) of 413 in the standard care group had serious adverse events, none of which were deemed related to the trial intervention. INTERPRETATION: In adult patients without ST elevation, transfer to a cardiac arrest centre following resuscitated cardiac arrest in the community did not reduce deaths. FUNDING: British Heart Foundation.


Subject(s)
Out-of-Hospital Cardiac Arrest , ST Elevation Myocardial Infarction , Adult , Humans , Male , Female , Adolescent , Out-of-Hospital Cardiac Arrest/therapy , Prospective Studies , Treatment Outcome , London/epidemiology , Randomized Controlled Trials as Topic
2.
Catheter Cardiovasc Interv ; 99(2): 391-396, 2022 02.
Article in English | MEDLINE | ID: mdl-34967091

ABSTRACT

BACKGROUND: The impact of COVID-19 on the diagnosis and management of nonculprit lesions remains unclear. OBJECTIVES: This study sought to evaluate the management and outcomes of patients with nonculprit lesions during the COVID-19 pandemic. METHODS: We conducted a retrospective observational analysis of consecutive primary percutaneous coronary intervention (PPCI) pathway activations across the heart attack center network in London, UK. Data from the study period in 2020 were compared with prepandemic data in 2019. The primary outcome was the rate of nonculprit lesion percutaneous coronary intervention (PCI) and secondary outcomes included major adverse cardiovascular events. RESULTS: A total of 788 patients undergoing PPCI were identified, 209 (60%) in 2020 cohort and 263 (60%) in 2019 cohort had nonculprit lesions (p = .89). There was less functional assessment of the significance of nonculprit lesions in the 2020 cohort compared to 2019 cohort; in 8% 2020 cohort versus 15% 2019 cohort (p = .01). There was no difference in rates of PCI for nonculprit disease in the 2019 and 2020 cohorts (31% vs 30%, p = .11). Patients in 2020 cohort underwent nonculprit lesion PCI sooner than the 2019 cohort (p < .001). At 6 months there was higher rates of unplanned revascularization (4% vs. 2%, p = .05) and repeat myocardial infarction (4% vs. 1%, p = .02) in the 2019 cohort compared to 2020 cohort. CONCLUSION: Changes to clinical practice during the COVID-19 pandemic were associated with reduced rates of unplanned revascularization and myocardial infarction at 6-months follow-up, and despite the pandemic, there was no difference in mortality, suggesting that it is not only safe but maybe more efficacious.


Subject(s)
COVID-19 , Myocardial Infarction , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , London/epidemiology , Myocardial Infarction/etiology , Pandemics , Percutaneous Coronary Intervention/adverse effects , Retrospective Studies , SARS-CoV-2 , ST Elevation Myocardial Infarction/diagnostic imaging , ST Elevation Myocardial Infarction/etiology , ST Elevation Myocardial Infarction/therapy , Treatment Outcome
3.
Catheter Cardiovasc Interv ; 97(4): E552-E559, 2021 03.
Article in English | MEDLINE | ID: mdl-32779877

ABSTRACT

OBJECTIVES: We sought to identify baseline demographics and procedural factors that might independently predict in-hospital stroke following transcatheter aortic valve implantation (TAVI). BACKGROUND: Stroke is a recognized, albeit infrequent, complication of TAVI. Established predictors of procedure-related in-hospital stroke; however, remain poorly defined. METHODS: We conducted an observational cohort analysis of the multicenter UK TAVI registry. The primary outcome measure was the incidence of in-hospital stroke. RESULTS: A total of 8,652 TAVI procedures were performed from 2007 to 2015. There were 205 in-hospital strokes reported by participating centers equivalent to an overall stroke incidence of 2.4%. Univariate analysis showed that the implantation of balloon-expandable valves caused significantly fewer strokes (balloon-expandable 96/4,613 [2.08%] vs. self-expandable 95/3,272 [2.90%]; p = .020). After multivariable analysis, prior cerebrovascular disease (CVD) (odds ratio [OR] 1.51, 95% confidence interval [CI 1.05-2.17]; p = .03), advanced age at time of operation (OR 1.02 [0.10-1.04]; p = .05), bailout coronary stenting (OR 5.94 [2.03-17.39]; p = .008), and earlier year of procedure (OR 0.93 [0.87-1.00]; p = .04) were associated with an increased in-hospital stroke risk. There was a reduced stroke risk in those who had prior cardiac surgery (OR 0.62 [0.41-0.93]; p = .01) and a first-generation balloon-expandable valve implanted (OR 0.72 [0.53-0.97]; p = .03). In-hospital stroke significantly increased 30-day (OR 5.22 [3.49-7.81]; p < .001) and 1-year mortality (OR 3.21 [2.15-4.78]; p < .001). CONCLUSIONS: In-hospital stroke after TAVI is associated with substantially increased early and late mortality. Factors independently associated with in-hospital stroke were previous CVD, advanced age, no prior cardiac surgery, and deployment of a predominantly first-generation self-expandable transcatheter heart valve.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Cohort Studies , Hospitals , Humans , Stroke/epidemiology , Stroke/etiology , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , United Kingdom/epidemiology
4.
Catheter Cardiovasc Interv ; 97(3): 516-526, 2021 02 15.
Article in English | MEDLINE | ID: mdl-32865860

ABSTRACT

OBJECTIVE: To evaluate the incidence, predictors and outcomes of female patients with patient-prosthesis mismatch (PPM) following transcatheter aortic valve intervention (TAVI) for severe aortic stenosis (AS). BACKGROUND: Female AS TAVI recipients have a significantly lower mortality than surgical aortic valve replacement (SAVR) recipients, which could be attributed to the potentially lower PPM rates. TAVI has been associated with lower rates of PPM compared to SAVR. PPM in females post TAVI has not been investigated to date. METHODS: The WIN-TAVI (Women's INternational Transcatheter Aortic Valve Implantation) registry is a multicenter registry of women undergoing TAVR for severe symptomatic AS. Two hundred and fifty patients with detailed periprocedural and follow-up echocardiographic investigations were included in the WIN-TAVI echocardiographic sub-study. PPM was defined as per European guidelines stratified by the presence of obesity. RESULTS: The incidence of PPM in our population was 32.8%. Patients with PPM had significantly higher BMI (27.4 ± 6.1 vs. 25.2 ± 5.0, p = .002), smaller sized valves implanted (percentage of TAVI ≤23 mm 61% vs. 29.2%, PPM vs. no PPM, p < .001) and were more often treated with balloon expandable valves (48.3 vs. 32.5%, p < .001) rather than self expanding ones (26.3 vs. 52.8%, <.001). BMI (OR = 1.08; 95%CI 1.02-1.14, p = .011) and valve size ≤23 mm (OR = 3.00 95%CI 1.14-7.94, p = .027) were the only independent predictors of PPM. There was no significant interaction between valve size and valve type (p = .203). No significant differences were observed in 1-year mortality or major adverse cardiovascular events. CONCLUSIONS: PPM in females undergoing TAVI occurs in one third of patients. BMI and valve size ≤23 mm are independent predictors. Larger registries are required to determine the impact of PPM on future clinical outcomes.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/epidemiology , Aortic Valve Stenosis/surgery , Female , Humans , Postoperative Complications , Prevalence , Registries , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
5.
Catheter Cardiovasc Interv ; 98(3): E444-E452, 2021 09.
Article in English | MEDLINE | ID: mdl-33502784

ABSTRACT

OBJECTIVES: To determine whether a permanent pacemaker (PPM) in situ can enhance survival after transcatheter aortic valve implantation (TAVI), in a predominantly inoperable or high risk cohort. BACKGROUND: New conduction disturbances are the most frequent complication of TAVI, often necessitating PPM implantation before hospital discharge. METHODS: We performed an observational cohort analysis of the UK TAVI registry (2007-2015). Primary and secondary endpoints were 30-day post-discharge all-cause mortality and long-term survival, respectively. RESULTS: Of 8,651 procedures, 6,815 complete datasets were analyzed. A PPM at hospital discharge, irrespective of when implantation occurred (PPM 1.68% [22/1309] vs. no PPM 1.47% [81/5506], odds ratio [OR] 1.14, 95% confidence interval [CI] 0.71-1.84; p = .58), or a PPM implanted peri- or post-TAVI only (PPM 1.44% [11/763] vs. no PPM 1.47% [81/5506], OR 0.98 [0.51-1.85]; p = .95) did not significantly reduce the primary endpoint. Patients with a PPM at discharge were older, male, had right bundle branch block at baseline, were more likely to have received a first-generation self-expandable prosthesis and had experienced more peri- and post-procedural complications including bailout valve-in-valve rescue, bleeding and acute kidney injury. A Cox proportional hazards model demonstrated significantly reduced long-term survival in all those with a PPM, irrespective of implantation timing (hazard ratio [HR] 1.14 [1.02-1.26]; p = .019) and those receiving a PPM only at the time of TAVI (HR 1.15 [1.02-1.31]; p = .032). The reasons underlying this observation warrant further investigation. CONCLUSIONS: A PPM did not confer a survival advantage in the first 30 days after hospital discharge following TAVI.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Aftercare , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Male , Patient Discharge , Postoperative Complications , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
6.
Perfusion ; 36(6): 547-558, 2021 09.
Article in English | MEDLINE | ID: mdl-33427055

ABSTRACT

The COVID-19 pandemic has altered our approach to inpatient echocardiography delivery. There is now a greater focus to address key clinical questions likely to make an immediate impact in management, particularly during the period of widespread infection. Handheld echocardiography (HHE) can be used as a first-line assessment tool, limiting scanning time and exposure to high viral load. This article describes a potential role for HHE during a pandemic. We propose a protocol with a reporting template for a focused core dataset necessary in delivering an acute echocardiography service in the setting of a highly contagious disease, minimising risk to the operator. We cover the scenarios typically encountered in the acute cardiology setting and how an expert trained echocardiography team can identify such pathologies using a limited imaging format and include cardiac presentations encountered in those patients acutely unwell with COVID-19.


Subject(s)
COVID-19 , Cardiology , Echocardiography , Humans , Pandemics , SARS-CoV-2
7.
Circulation ; 140(24): 1971-1980, 2019 12 10.
Article in English | MEDLINE | ID: mdl-31707827

ABSTRACT

BACKGROUND: Dobutamine stress echocardiography is widely used to test for ischemia in patients with stable coronary artery disease. In this analysis, we studied the ability of the prerandomization stress echocardiography score to predict the placebo-controlled efficacy of percutaneous coronary intervention (PCI) within the ORBITA trial (Objective Randomised Blinded Investigation With Optimal Medical Therapy of Angioplasty in Stable Angina). METHODS: One hundred eighty-three patients underwent dobutamine stress echocardiography before randomization. The stress echocardiography score is broadly the number of segments abnormal at peak stress, with akinetic segments counting double and dyskinetic segments counting triple. The ability of prerandomization stress echocardiography to predict the placebo-controlled effect of PCI on response variables was tested by using regression modeling. RESULTS: At prerandomization, the stress echocardiography score was 1.56±1.77 in the PCI arm (n=98) and 1.61±1.73 in the placebo arm (n=85). There was a detectable interaction between prerandomization stress echocardiography score and the effect of PCI on angina frequency score with a larger placebo-controlled effect in patients with the highest stress echocardiography score (Pinteraction=0.031). With our sample size, we were unable to detect an interaction between stress echocardiography score and any other patient-reported response variables: freedom from angina (Pinteraction=0.116), physical limitation (Pinteraction=0.461), quality of life (Pinteraction=0.689), EuroQOL 5 quality-of-life score (Pinteraction=0.789), or between stress echocardiography score and physician-assessed Canadian Cardiovascular Society angina class (Pinteraction=0.693), and treadmill exercise time (Pinteraction=0.426). CONCLUSIONS: The degree of ischemia assessed by dobutamine stress echocardiography predicts the placebo-controlled efficacy of PCI on patient-reported angina frequency. The greater the downstream stress echocardiography abnormality caused by a stenosis, the greater the reduction in symptoms from PCI. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02062593.


Subject(s)
Coronary Artery Disease/drug therapy , Dobutamine/pharmacology , Echocardiography, Stress/drug effects , Ischemia/drug therapy , Aged , Angina, Stable/diagnosis , Angina, Stable/drug therapy , Coronary Artery Disease/diagnosis , Dobutamine/administration & dosage , Exercise Tolerance/drug effects , Female , Humans , Ischemia/etiology , Ischemia/physiopathology , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Quality of Life
8.
N Engl J Med ; 376(19): 1824-1834, 2017 05 11.
Article in English | MEDLINE | ID: mdl-28317458

ABSTRACT

BACKGROUND: Coronary revascularization guided by fractional flow reserve (FFR) is associated with better patient outcomes after the procedure than revascularization guided by angiography alone. It is unknown whether the instantaneous wave-free ratio (iFR), an alternative measure that does not require the administration of adenosine, will offer benefits similar to those of FFR. METHODS: We randomly assigned 2492 patients with coronary artery disease, in a 1:1 ratio, to undergo either iFR-guided or FFR-guided coronary revascularization. The primary end point was the 1-year risk of major adverse cardiac events, which were a composite of death from any cause, nonfatal myocardial infarction, or unplanned revascularization. The trial was designed to show the noninferiority of iFR to FFR, with a margin of 3.4 percentage points for the difference in risk. RESULTS: At 1 year, the primary end point had occurred in 78 of 1148 patients (6.8%) in the iFR group and in 83 of 1182 patients (7.0%) in the FFR group (difference in risk, -0.2 percentage points; 95% confidence interval [CI], -2.3 to 1.8; P<0.001 for noninferiority; hazard ratio, 0.95; 95% CI, 0.68 to 1.33; P=0.78). The risk of each component of the primary end point and of death from cardiovascular or noncardiovascular causes did not differ significantly between the groups. The number of patients who had adverse procedural symptoms and clinical signs was significantly lower in the iFR group than in the FFR group (39 patients [3.1%] vs. 385 patients [30.8%], P<0.001), and the median procedural time was significantly shorter (40.5 minutes vs. 45.0 minutes, P=0.001). CONCLUSIONS: Coronary revascularization guided by iFR was noninferior to revascularization guided by FFR with respect to the risk of major adverse cardiac events at 1 year. The rate of adverse procedural signs and symptoms was lower and the procedural time was shorter with iFR than with FFR. (Funded by Philips Volcano; DEFINE-FLAIR ClinicalTrials.gov number, NCT02053038 .).


Subject(s)
Acute Coronary Syndrome/physiopathology , Coronary Stenosis/physiopathology , Coronary Stenosis/therapy , Fractional Flow Reserve, Myocardial , Percutaneous Coronary Intervention/methods , Acute Coronary Syndrome/diagnostic imaging , Aged , Angina Pectoris/diagnostic imaging , Angina Pectoris/physiopathology , Cardiovascular Diseases/mortality , Coronary Angiography , Coronary Stenosis/diagnostic imaging , Female , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/epidemiology , Retreatment , Severity of Illness Index
9.
Catheter Cardiovasc Interv ; 96(7): E747-E754, 2020 12.
Article in English | MEDLINE | ID: mdl-31631520

ABSTRACT

Trans-Axillary Transcatheter Aortic Valve Replacement (TAVR) has become established as the safest arterial approach when femoral arterial anatomy is unfavorable. Although a left sided axillary approach is generally preferred, patient specific factors may require use of the right axillary artery. In this case series we describe procedural modifications that are required to overcome the challenge of restricted space in the ascending aorta for in situ valve preparation of balloon-expandable valve systems when a right sided trans-Axillary approach is taken. These steps permit implantation of both the Edwards LifeSciences Sapien 3 and Ultra prostheses via the right trans-Axillary approach, allowing patients a greater range of valve options when this arterial route is required for TAVR.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Axillary Artery , Catheterization, Peripheral , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Catheterization, Peripheral/adverse effects , Female , Humans , Male , Prosthesis Design , Punctures , Severity of Illness Index , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
10.
J Thromb Thrombolysis ; 50(1): 82-89, 2020 Jul.
Article in English | MEDLINE | ID: mdl-31605280

ABSTRACT

The optimal antithrombotic therapy for patients undergoing TAVI with concomitant indication for oral anticoagulation remains unclear. In this high-risk population group, there is a paucity of data with regards to the use of DOACs. In the present study we compared long-term clinical outcomes of TAVI patients requiring anticoagulation, treated with warfarin versus DOACs. Consecutive patients, who underwent TAVI with indication for oral anticoagulation from the multicenter ATLAS registry were studied and divided in two groups depending on the chosen anticoagulation regimen, warfarin vs. DOACs. 30-day survival, as well as estimated 1 and 2-year all-cause mortality were compared between groups. The secondary endpoint included in-hospital major or life-threatening bleeding. The study group included 217 patients (102 treated with warfarin; 115 treated with DOACs). Kaplan-Meier estimated survival was found to be statistically similar in the warfarin and DOAC groups (90.6% vs. 93.7% for 1-year and 84.5% vs. 88.5%, for 2-year survival, respectively, Plog-rank = 0.984). Adjusted hazard ratio for all cause mortality was similar between the two groups (HRwarfarin vs. DOAC = 1.15; 95% CI 0.33 to 4.04, p = 0.829). Propensity matching revealed similar results. At 30-days, all-cause mortality was found to be comparable between the two groups. With regards to BARC defined bleeding complications, major and life-threatening complications did not differ between the two anticoagulation groups (6% vs. 8% for warfarin and DOACs respectively, p = 0.857). DOACs seem to demonstrate a similar safety and efficacy profile compared to warfarin in TAVI patients with a concomitant indication for oral anticoagulation.


Subject(s)
Aortic Valve Stenosis/surgery , Factor Xa Inhibitors , Hemorrhage , Long Term Adverse Effects , Postoperative Complications , Thrombosis , Transcatheter Aortic Valve Replacement/adverse effects , Warfarin , Aged, 80 and over , Anticoagulants/administration & dosage , Anticoagulants/adverse effects , Blood Coagulation/drug effects , Factor Xa Inhibitors/administration & dosage , Factor Xa Inhibitors/adverse effects , Female , Hemorrhage/chemically induced , Hemorrhage/diagnosis , Hemorrhage/prevention & control , Humans , Long Term Adverse Effects/diagnosis , Long Term Adverse Effects/etiology , Long Term Adverse Effects/mortality , Male , Patient Selection , Postoperative Complications/blood , Postoperative Complications/mortality , Postoperative Complications/prevention & control , Prognosis , Registries/statistics & numerical data , Survival Analysis , Thrombosis/blood , Thrombosis/etiology , Thrombosis/mortality , Thrombosis/prevention & control , Transcatheter Aortic Valve Replacement/methods , Warfarin/administration & dosage , Warfarin/adverse effects
11.
Eur Heart J ; 40(31): 2620-2629, 2019 08 14.
Article in English | MEDLINE | ID: mdl-31220238

ABSTRACT

AIMS: The public reporting of healthcare outcomes has a number of potential benefits; however, unintended consequences may limit its effectiveness as a quality improvement process. We aimed to assess whether the introduction of individual operator specific outcome reporting after percutaneous coronary intervention (PCI) in the UK was associated with a change in patient risk factor profiles, procedural management, or 30-day mortality outcomes in a large cohort of consecutive patients. METHODS AND RESULTS: This was an observational cohort study of 123 780 consecutive PCI procedures from the Pan-London (UK) PCI registry, from January 2005 to December 2015. Outcomes were compared pre- (2005-11) and post- (2011-15) public reporting including the use of an interrupted time series analysis. Patients treated after public reporting was introduced were older and had more complex medical problems. Despite this, reported in-hospital major adverse cardiovascular and cerebrovascular events rates were significantly lower after the introduction of public reporting (2.3 vs. 2.7%, P < 0.0001). Interrupted time series analysis demonstrated evidence of a reduction in 30-day mortality rates after the introduction of public reporting, which was over and above the existing trend in mortality before the introduction of public outcome reporting (35% decrease relative risk 0.64, 95% confidence interval 0.55-0.77; P < 0.0001). CONCLUSION: The introduction of public reporting has been associated with an improvement in outcomes after PCI in this data set, without evidence of risk-averse behaviour. However, the lower reported complication rates might suggest a change in operator behaviour and decision-making confirming the need for continued surveillance of the impact of public reporting on outcomes and operator behaviour.


Subject(s)
Acute Coronary Syndrome/surgery , Angina, Stable/surgery , Cardiologists/psychology , Interrupted Time Series Analysis/methods , Patient Care Management/statistics & numerical data , Acute Coronary Syndrome/diagnosis , Aged , Angina, Stable/diagnosis , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/mortality , Case-Control Studies , Cerebrovascular Disorders/epidemiology , Cerebrovascular Disorders/mortality , Clinical Decision-Making/ethics , Female , Hospital Mortality/trends , Humans , Male , Mandatory Reporting/ethics , Middle Aged , Patient Care Management/ethics , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Percutaneous Coronary Intervention/statistics & numerical data , Professional Misconduct/statistics & numerical data , Prospective Studies , Quality Improvement/standards , Registries , Risk Factors , Treatment Outcome , United Kingdom/epidemiology
12.
Circulation ; 138(17): 1780-1792, 2018 10 23.
Article in English | MEDLINE | ID: mdl-29789302

ABSTRACT

BACKGROUND: There are no data on how fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) are associated with the placebo-controlled efficacy of percutaneous coronary intervention (PCI) in stable single-vessel coronary artery disease. METHODS: We report the association between prerandomization invasive physiology within ORBITA (Objective Randomised Blinded Investigation With Optimal Medical Therapy of Angioplasty in Stable Angina), a placebo-controlled trial of patients who have stable angina with angiographically severe single-vessel coronary disease clinically eligible for PCI. Patients underwent prerandomization research FFR and iFR assessment. The operator was blinded to these values. Assessment of response variables, treadmill exercise time, stress echocardiography score, symptom frequency, and angina severity were performed at prerandomization and blinded follow-up. Effects were calculated by analysis of covariance. The ability of FFR and iFR to predict placebo-controlled changes in response variables was tested by using regression modeling. RESULTS: Invasive physiology data were available in 196 patients (103 PCI and 93 placebo). At prerandomization, the majority had Canadian Cardiovascular Society class II or III symptoms (150/196, 76.5%). Mean FFR and iFR were 0.69±0.16 and 0.76±0.22, respectively; 97% had ≥1 positive ischemia tests. The estimated effect of PCI on between-arm prerandomization-adjusted total exercise time was 20.7 s (95% confidence interval [CI], -4.0 to 45.5; P=0.100) with no interaction of FFR ( Pinteraction=0.318) or iFR ( Pinteraction=0.523). PCI improved stress echocardiography score more than placebo (1.07 segment units; 95% CI, 0.70-1.44; P<0.00001). The placebo-controlled effect of PCI on stress echocardiography score increased progressively with decreasing FFR ( Pinteraction<0.00001) and decreasing iFR ( Pinteraction<0.00001). PCI did not improve angina frequency score significantly more than placebo (odds ratio, 1.64; 95% CI, 0.96-2.80; P=0.072) with no detectable evidence of interaction with FFR ( Pinteraction=0.849) or iFR ( Pinteraction=0.783). However, PCI resulted in more patient-reported freedom from angina than placebo (49.5% versus 31.5%; odds ratio, 2.47; 95% CI, 1.30-4.72; P=0.006) but neither FFR ( Pinteraction=0.693) nor iFR ( Pinteraction=0.761) modified this effect. CONCLUSIONS: In patients with stable angina and severe single-vessel disease, the blinded effect of PCI was more clearly seen by stress echocardiography score and freedom from angina than change in treadmill exercise time. Moreover, the lower the FFR or iFR, the greater the magnitude of stress echocardiographic improvement caused by PCI. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02062593.


Subject(s)
Angina, Stable/therapy , Cardiac Catheterization , Coronary Artery Disease/therapy , Coronary Stenosis/therapy , Fractional Flow Reserve, Myocardial , Percutaneous Coronary Intervention , Adrenergic beta-1 Receptor Agonists/administration & dosage , Aged , Angina, Stable/diagnosis , Angina, Stable/physiopathology , Coronary Angiography , Coronary Artery Disease/diagnosis , Coronary Artery Disease/physiopathology , Coronary Stenosis/diagnosis , Coronary Stenosis/physiopathology , Dobutamine/administration & dosage , Echocardiography, Stress/methods , Exercise Test , Exercise Tolerance , Female , Health Status , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Predictive Value of Tests , Progression-Free Survival , Quality of Life , Recovery of Function , Severity of Illness Index , Time Factors , United Kingdom
13.
Lancet ; 391(10115): 31-40, 2018 01 06.
Article in English | MEDLINE | ID: mdl-29103656

ABSTRACT

BACKGROUND: Symptomatic relief is the primary goal of percutaneous coronary intervention (PCI) in stable angina and is commonly observed clinically. However, there is no evidence from blinded, placebo-controlled randomised trials to show its efficacy. METHODS: ORBITA is a blinded, multicentre randomised trial of PCI versus a placebo procedure for angina relief that was done at five study sites in the UK. We enrolled patients with severe (≥70%) single-vessel stenoses. After enrolment, patients received 6 weeks of medication optimisation. Patients then had pre-randomisation assessments with cardiopulmonary exercise testing, symptom questionnaires, and dobutamine stress echocardiography. Patients were randomised 1:1 to undergo PCI or a placebo procedure by use of an automated online randomisation tool. After 6 weeks of follow-up, the assessments done before randomisation were repeated at the final assessment. The primary endpoint was difference in exercise time increment between groups. All analyses were based on the intention-to-treat principle and the study population contained all participants who underwent randomisation. This study is registered with ClinicalTrials.gov, number NCT02062593. FINDINGS: ORBITA enrolled 230 patients with ischaemic symptoms. After the medication optimisation phase and between Jan 6, 2014, and Aug 11, 2017, 200 patients underwent randomisation, with 105 patients assigned PCI and 95 assigned the placebo procedure. Lesions had mean area stenosis of 84·4% (SD 10·2), fractional flow reserve of 0·69 (0·16), and instantaneous wave-free ratio of 0·76 (0·22). There was no significant difference in the primary endpoint of exercise time increment between groups (PCI minus placebo 16·6 s, 95% CI -8·9 to 42·0, p=0·200). There were no deaths. Serious adverse events included four pressure-wire related complications in the placebo group, which required PCI, and five major bleeding events, including two in the PCI group and three in the placebo group. INTERPRETATION: In patients with medically treated angina and severe coronary stenosis, PCI did not increase exercise time by more than the effect of a placebo procedure. The efficacy of invasive procedures can be assessed with a placebo control, as is standard for pharmacotherapy. FUNDING: NIHR Imperial Biomedical Research Centre, Foundation for Circulatory Health, Imperial College Healthcare Charity, Philips Volcano, NIHR Barts Biomedical Research Centre.


Subject(s)
Angina, Stable/surgery , Coronary Stenosis/surgery , Percutaneous Coronary Intervention , Aged , Angina, Stable/complications , Angina, Stable/diagnostic imaging , Coronary Angiography , Coronary Stenosis/complications , Coronary Stenosis/diagnostic imaging , Double-Blind Method , Exercise Tolerance , Female , Humans , Male , Middle Aged , Treatment Outcome , United Kingdom
14.
Catheter Cardiovasc Interv ; 93(4): 751-757, 2019 03 01.
Article in English | MEDLINE | ID: mdl-30394657

ABSTRACT

OBJECTIVES: The UK & Ireland Implanters' registry is a multicenter registry which reports on real-world experience with novel transcatheter heart valves. BACKGROUND: The 34 mm Evolut R transcatheter aortic valve is a self-expanding and fully recapturable transcatheter aortic valve, designed to treat patients with a large aortic annulus. METHODS: Between January 2017 and April 2018, clinical, procedural and 30-day outcome data were prospectively collected from all patients receiving the 34 mm Evolut R valve across 17 participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2(VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 217 patients underwent attempted implant. Mean age was 79.5 ± 8.8 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.2% ± 3.4%. Iliofemoral access was used in 91.2% of patients. Device success was 79.7%. Mean gradient was 7.0 ± 4.6 mmHg and effective orifice area 2.0 ± 0.6 cm2 . Paravalvular regurgitation was more than mild in 7.2%. A new permanent pacemaker was implanted in 15.7%. Early safety was demonstrated in 91.2%. At 30 days, all-cause mortality was 3.2%, stroke 3.7%, and major vascular complication 2.3%. CONCLUSIONS: Real-world experience of the 34 mm Evolut R transcatheter aortic valve demonstrated acceptable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Hemodynamics , Humans , Ireland , Male , Postoperative Complications/mortality , Postoperative Complications/therapy , Prosthesis Design , Registries , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United Kingdom
15.
Eur Heart J ; 39(18): 1638-1649, 2018 05 07.
Article in English | MEDLINE | ID: mdl-29590333

ABSTRACT

Aims: The efficacy of patent foramen ovale (PFO) closure for cryptogenic stroke has been controversial. We undertook a meta-analysis of randomized controlled trials (RCTs) comparing device closure with medical therapy to prevent recurrent stroke for patients with PFO. Methods and results: We systematically identified all RCTs comparing device closure to medical therapy for cryptogenic stroke in patients with PFO. The primary efficacy endpoint was recurrent stroke, analysed on an intention-to-treat basis. The primary safety endpoint was new onset atrial fibrillation (AF). Five studies (3440 patients) were included. In all, 1829 patients were randomized to device closure and 1611 to medical therapy. Across all patients, PFO closure was superior to medical therapy for prevention of stroke [hazard ratio (HR) 0.32, 95% confidence interval (95% CI) 0.13-0.82; P = 0.018, I2 = 73.4%]. The risk of AF was significantly increased with device closure [risk ratio (RR) 4.68, 95% CI 2.19-10.00, P<0.001, heterogeneity I2 = 27.5%)]. In patients with large shunts, PFO closure was associated with a significant reduction in stroke (HR 0.33, 95% CI 0.16-0.72; P = 0.005), whilst there was no significant reduction in stroke in patients with a small shunt (HR 0.90, 95% CI 0.50-1.60; P = 0.712). There was no effect from the presence or absence of an atrial septal aneurysm on outcomes (P = 0.994). Conclusion: In selected patients with cryptogenic stroke, PFO closure is superior to medical therapy for the prevention of further stroke: this is particularly true for patients with moderate-to-large shunts. Guidelines should be updated to reflect this.


Subject(s)
Foramen Ovale, Patent/drug therapy , Foramen Ovale, Patent/surgery , Septal Occluder Device , Stroke/prevention & control , Foramen Ovale, Patent/complications , Humans , Randomized Controlled Trials as Topic , Recurrence , Stroke/etiology , Treatment Outcome
16.
J Stroke Cerebrovasc Dis ; 28(10): 104277, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31327683

ABSTRACT

Transcatheter Aortic Valve Implantation (TAVI) is an increasingly treatment modality for severe aortic stenosis, which is associated with a considerable peri-procedural risk of stroke. To date, the clinical safety and efficacy of Tissue plasminogen activator (tPA) and mechanical thrombectomy in stroke post-TAVI is not established. We describe 2 cases of patients with stroke after TAVI who received tPA therapy and mechanical thrombectomy.


Subject(s)
Fibrinolytic Agents/administration & dosage , Stroke/therapy , Thrombectomy/methods , Thrombolytic Therapy/methods , Transcatheter Aortic Valve Replacement/adverse effects , Administration, Intravenous , Aged, 80 and over , Humans , Male , Stroke/diagnostic imaging , Stroke/etiology , Stroke/physiopathology , Treatment Outcome
17.
Circulation ; 134(13): 934-44, 2016 Sep 27.
Article in English | MEDLINE | ID: mdl-27587432

ABSTRACT

BACKGROUND: Paravalvular leak (PVL) occurs in 5% to 17% of patients following surgical valve replacement. Percutaneous device closure represents an alternative to repeat surgery. METHODS: All UK and Ireland centers undertaking percutaneous PVL closure submitted data to the UK PVL Registry. Data were analyzed for association with death and major adverse cardiovascular events (MACE) at follow-up. RESULTS: Three hundred eight PVL closure procedures were attempted in 259 patients in 20 centers (2004-2015). Patient age was 67±13 years; 28% were female. The main indications for closure were heart failure (80%) and hemolysis (16%). Devices were successfully implanted in 91% of patients, via radial (7%), femoral arterial (52%), femoral venous (33%), and apical (7%) approaches. Nineteen percent of patients required repeat procedures. The target valve was mitral (44%), aortic (48%), both (2%), pulmonic (0.4%), or transcatheter aortic valve replacement (5%). Preprocedural leak was severe (61%), moderate (34%), or mild (5.7%) and was multiple in 37%. PVL improved postprocedure (P<0.001) and was none (33.3%), mild (41.4%), moderate (18.6%), or severe (6.7%) at last follow-up. Mean New York Heart Association class improved from 2.7±0.8 preprocedure to 1.6±0.8 (P<0.001) after a median follow-up of 110 (7-452) days. Hospital mortality was 2.9% (elective), 6.8% (in-hospital urgent), and 50% (emergency) (P<0.001). MACE during follow-up included death (16%), valve surgery (6%), late device embolization (0.4%), and new hemolysis requiring transfusion (1.6%). Mitral PVL was associated with higher MACE (hazard ratio [HR], 1.83; P=0.011). Factors independently associated with death were the degree of persisting leak (HR, 2.87; P=0.037), New York Heart Association class (HR, 2.00; P=0.015) at follow-up and baseline creatinine (HR, 8.19; P=0.001). The only factor independently associated with MACE was the degree of persisting leak at follow-up (HR, 3.01; P=0.002). CONCLUSION: Percutaneous closure of PVL is an effective procedure that improves PVL severity and symptoms. Severity of persisting leak at follow-up is independently associated with both MACE and death. Percutaneous closure should be considered as an alternative to repeat surgery.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve/surgery , Postoperative Complications/etiology , Prosthesis Failure/adverse effects , Transcatheter Aortic Valve Replacement , Adult , Aged , Aged, 80 and over , Cardiac Catheterization/methods , Female , Heart Failure/etiology , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Ireland , Male , Middle Aged , Reoperation/methods , Transcatheter Aortic Valve Replacement/methods , United Kingdom
18.
Eur Heart J ; 37(26): 2029-36, 2016 Jul 07.
Article in English | MEDLINE | ID: mdl-26908949

ABSTRACT

AIMS: Migraine with aura and patent foramen ovale (PFO) are associated. The Percutaneous Closure of PFO in Migraine with Aura (PRIMA) trial is a multicentre, randomized trial to investigate the effect of percutaneous PFO closure in patients refractory to medical treatment. METHODS: Migraine with aura patients and PFO who were unresponsive to preventive medications were randomized to PFO closure or medical treatment. Both groups were given acetylsalicylic acid 75-100 mg/day for 6 months and clopidogrel 75 mg/day for 3 months. The primary endpoint was reduction in monthly migraine days during months 9-12 after randomization compared with a 3-month baseline phase before randomization. The committee reviewing the headache diaries were blinded to treatment assignment. RESULTS: One hundred and seven patients were randomly allocated to treatment with an Amplatzer PFO Occluder (N = 53) or control with medical management (N = 54). The trial was terminated prematurely because of slow enrolment. Eighty-three patients (40 occluder, 43 control) completed 12-month follow-up. Mean migraine days at baseline were 8 (±4.7 SD) in the closure group and 8.3 (±2.4) in controls. The primary endpoint was negative with -2.9 days after PFO closure vs. -1.7 days in control group (P = 0.17). Patent foramen ovale closure caused five adverse events without permanent sequelae. CONCLUSION: In patients with refractory migraine with aura and PFO, PFO closure did not reduce overall monthly migraine days.


Subject(s)
Foramen Ovale, Patent , Migraine Disorders , Humans , Septal Occluder Device , Treatment Outcome
19.
Am J Physiol Heart Circ Physiol ; 310(5): H619-27, 2016 Mar 01.
Article in English | MEDLINE | ID: mdl-26683900

ABSTRACT

Wave intensity analysis (WIA) has found particular applicability in the coronary circulation where it can quantify traveling waves that accelerate and decelerate blood flow. The most important wave for the regulation of flow is the backward-traveling decompression wave (BDW). Coronary WIA has hitherto always been calculated from invasive measures of pressure and flow. However, recently it has become feasible to obtain estimates of these waveforms noninvasively. In this study we set out to assess the agreement between invasive and noninvasive coronary WIA at rest and measure the effect of exercise. Twenty-two patients (mean age 60) with unobstructed coronaries underwent invasive WIA in the left anterior descending artery (LAD). Immediately afterwards, noninvasive LAD flow and pressure were recorded and WIA calculated from pulsed-wave Doppler coronary flow velocity and central blood pressure waveforms measured using a cuff-based technique. Nine of these patients underwent noninvasive coronary WIA assessment during exercise. A pattern of six waves were observed in both modalities. The BDW was similar between invasive and noninvasive measures [peak: 14.9 ± 7.8 vs. -13.8 ± 7.1 × 10(4) W·m(-2)·s(-2), concordance correlation coefficient (CCC): 0.73, P < 0.01; cumulative: -64.4 ± 32.8 vs. -59.4 ± 34.2 × 10(2) W·m(-2)·s(-1), CCC: 0.66, P < 0.01], but smaller waves were underestimated noninvasively. Increased left ventricular mass correlated with a decreased noninvasive BDW fraction (r = -0.48, P = 0.02). Exercise increased the BDW: at maximum exercise peak BDW was -47.0 ± 29.5 × 10(4) W·m(-2)·s(-2) (P < 0.01 vs. rest) and cumulative BDW -19.2 ± 12.6 × 10(3) W·m(-2)·s(-1) (P < 0.01 vs. rest). The BDW can be measured noninvasively with acceptable reliably potentially simplifying assessments and increasing the applicability of coronary WIA.


Subject(s)
Blood Pressure Determination , Coronary Circulation , Coronary Vessels/physiology , Echocardiography, Doppler, Color , Echocardiography, Doppler, Pulsed , Exercise/physiology , Aged , Arterial Pressure , Blood Flow Velocity , Blood Pressure Determination/instrumentation , Brachial Artery/physiology , Cardiac Catheterization , Coronary Vessels/diagnostic imaging , Exercise Test , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Reproducibility of Results , Sphygmomanometers , Time Factors
20.
J Heart Valve Dis ; 25(5): 552-556, 2016 09.
Article in English | MEDLINE | ID: mdl-28238236

ABSTRACT

Transcatheter aortic valve implantation (TAVI) is currently the treatment of choice for patients with severe aortic stenosis (AS) who are unsuitable for surgical aortic valve replacement (SAVR), and is an acceptable alternative for those at high and intermediate surgical risk. In published TAVI registries and meta-analyses, whilst women are significantly older they present with fewer comorbidities compared to men (including coronary artery disease, peripheral vascular disease, diabetes and chronic obstructive pulmonary disease). In response to chronic pressure overload from AS, women have been shown to develop greater levels of left ventricular hypertrophy than men, as well as having a greater preservation of LV ejection fraction (LVEF) and less fibrosis. Following aortic valve replacement, women have been shown to have a faster regression of myocardial hypertrophy, with a significant improvement in LVEF. Following TAVI, female gender seems to be associated with a significantly lower one-year mortality. In the current viewpoint, it is discussed whether these findings reflect a true differential treatment response to TAVI among women, or simply the higher comorbidity burden among males undergoing TAVI.


Subject(s)
Aortic Valve Stenosis/surgery , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Aortic Valve Stenosis/mortality , Comorbidity , Humans , Male , Risk Factors , Sex Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL