Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Language
Journal subject
Affiliation country
Publication year range
1.
Rev Argent Microbiol ; 47(1): 57-61, 2015.
Article in Spanish | MEDLINE | ID: mdl-25686652

ABSTRACT

Vertical transmission is the main route of HIV infection in childhood. Because of the persistence of maternal HIV antibodies, virologic assays that directly detect HIV are required to diagnose HIV infection in infants younger than 18 months of age. The sensitivity of HIV RNA/DNA assays increases as the child becomes older. These tests have specificity values greater than 95%. The aim of this study was to evaluate the performance of the COBAS Taqman HIV-1 Test, v1.0 assay (Roche) and its concordance with a Multiplex Nested-PCR. Of 341 samples processed, 15 were positive and 326 negative by both methods. Sensitivity and specificity overall values for the viral load assay were 88.2% and 100%, respectively. Our results indicate that the COBAS Taqman assay evaluated could be used as an alternative method to diagnose HIV congenital infection.


Subject(s)
HIV Infections/diagnosis , HIV Infections/transmission , Infectious Disease Transmission, Vertical , AIDS Serodiagnosis , HIV Infections/virology , Humans , Infant , Infant, Newborn , Polymerase Chain Reaction , Viral Load
2.
Rev. argent. microbiol ; Rev. argent. microbiol;47(1): 57-61, Mar. 2015.
Article in Spanish | LILACS, BINACIS | ID: biblio-1171813

ABSTRACT

La transmisión vertical es la principal vía de contagio del HIV en la edad pediátrica. El diagnóstico de la infección congénita antes de los 18meses se realiza mediante ensayos virológicos: detección de genoma viral como ARN plasmático y ADN proviral. La sensibilidad de estos ensayos varía según la edad del niño, con valores de especificidad mayores al 95%. El objetivo de este trabajo fue evaluar el desempeño del ensayo de carga viral (CV) COBAS Taqman HIV-1 Test, v1.0 (Roche), y su concordancia con una PCR múltiple anidada in-house para la detección del ADN proviral. De 341 muestras procesadas, 15 resultaron positivas y 326 negativas por ambas metodologías. Para la metodología de CV, la sensibilidad general fue del 88,2% y la especificidad del 100%. Nuestros resultados indican que la metodología de CV evaluada puede utilizarse como técnica alternativa para el diagnóstico de infección congénita por HIV


Vertical transmission is the main route of HIV infection in childhood. Because of the persistence of maternal HIV antibodies, virologic assays that directly detect HIV are required to diagnose HIV infection in infants younger than 18months of age. The sensitivity of HIV RNA/DNA assays increases as the child becomes older. These tests have specificity values greater than 95%. The aim of this study was to evaluate the performance of the COBAS Taqman HIV-1 Test, v1.0 assay (Roche) and its concordance with a Multiplex Nested-PCR. Of 341 samples processed, 15 were positive and 326 negative by both methods. Sensitivity and specificity overall values for the viral load assay were 88.2% and 100%, respectively. Our results indicate that the COBAS Taqman assay evaluated could be used as an alternative method to diagnose HIV congenital infection


Subject(s)
Humans , Male , Female , Infant, Newborn , Infant , Acquired Immunodeficiency Syndrome/congenital , Viral Load/genetics , Reagent Kits, Diagnostic/statistics & numerical data , Acquired Immunodeficiency Syndrome/diagnosis , Viral Load/methods
3.
Rev. argent. microbiol ; 47(1): 57-61, 2015 Jan-Mar.
Article in Spanish | BINACIS | ID: bin-133760

ABSTRACT

Vertical transmission is the main route of HIV infection in childhood. Because of the persistence of maternal HIV antibodies, virologic assays that directly detect HIV are required to diagnose HIV infection in infants younger than 18months of age. The sensitivity of HIV RNA/DNA assays increases as the child becomes older. These tests have specificity values greater than 95


. The aim of this study was to evaluate the performance of the COBAS Taqman HIV-1 Test, v1.0 assay (Roche) and its concordance with a Multiplex Nested-PCR. Of 341 samples processed, 15 were positive and 326 negative by both methods. Sensitivity and specificity overall values for the viral load assay were 88.2


and 100


, respectively. Our results indicate that the COBAS Taqman assay evaluated could be used as an alternative method to diagnose HIV congenital infection.

SELECTION OF CITATIONS