Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Publication year range
1.
NMR Biomed ; 28(2): 180-7, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25476994

ABSTRACT

One of the key challenges in the study of health-related aerosols is predicting and monitoring sites of particle deposition in the respiratory tract. The potential health risks of ambient exposure to environmental or workplace aerosols and the beneficial effects of medical aerosols are strongly influenced by the site of aerosol deposition along the respiratory tract. Nuclear medicine is the only current modality that combines quantification and regional localization of aerosol deposition, and this technique remains limited by its spatial and temporal resolutions and by patient exposure to radiation. Recent work in MRI has shed light on techniques to quantify micro-sized magnetic particles in living bodies by the measurement of associated static magnetic field variations. With regard to lung MRI, hyperpolarized helium-3 may be used as a tracer gas to compensate for the lack of MR signal in the airways, so as to allow assessment of pulmonary function and morphology. The extrathoracic region of the human respiratory system plays a critical role in determining aerosol deposition patterns, as it acts as a filter upstream from the lungs. In the present work, aerosol deposition in a mouth-throat phantom was measured using helium-3 MRI and compared with single-photon emission computed tomography. By providing high sensitivity with high spatial and temporal resolutions, phase-contrast helium-3 MRI offers new insights for the study of particle transport and deposition.


Subject(s)
Aerosols/administration & dosage , Contrast Media , Helium , Magnetic Resonance Imaging/methods , Respiratory System/anatomy & histology , Humans , Imaging, Three-Dimensional , Iron/metabolism , Magnetic Fields , Phantoms, Imaging , Tomography, Emission-Computed, Single-Photon , Tomography, X-Ray Computed
2.
Magn Reson Med ; 72(4): 1072-8, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24407833

ABSTRACT

PURPOSE: In MR-velocity phase-contrast measurements, increasing the encoding bipolar gradient, i.e., decreasing the field of speed, usually improves measurement precision. However, in gases, fast diffusion during the bipolar gradient pulses may dramatically decrease the signal-to-noise ratio, thus degrading measurement precision. These two effects are contradictory. This work aims at determining the optimal sequence parameters to improve the velocity measurement precision. THEORY AND METHODS: This work presents the theoretical optimization of bipolar gradient parameters (duration and amplitude) to improve velocity measurement precision. An analytical approximation is given as well as a numerical optimization. It is shown that the solution depends on the diffusion coefficient and T2 *. Experimental validation using hyperpolarized (3) He diluted in various buffer gases ((4) He, N2 , and SF6 ) is presented at 1.5 Tesla (T) in a straight pipe. RESULTS: Excellent agreement was found with the theoretical results for prediction of optimal field of speed and good agreement was found for the precision in measured velocity, but for SF6 buffered gas. CONCLUSION: The theoretical predictions were validated, providing a way to optimize velocity mapping in gases.


Subject(s)
Algorithms , Helium/analysis , Helium/chemistry , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Rheology/methods , Contrast Media/analysis , Contrast Media/chemistry , Diffusion , Isotopes/analysis , Isotopes/chemistry , Radiopharmaceuticals/analysis , Radiopharmaceuticals/chemistry , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL