Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Arthrosc Tech ; 11(2): e223-e228, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35155117

ABSTRACT

This article describes a technique for arthroscopic fixation of an osteochondritis dissecans (OCD) lesion of the medial talar dome with headless compression screws. This technique involves creation of a medial transmalleolar portal using a guide and drill. The medial transmalleolar portal grants perpendicular access for screw fixation of OCD lesions in addition to the potential for osteochondral autograft transplantation (OAT). Advantages include access to the medial talar dome without performing a medial malleolar osteotomy. After completion of OCD fixation, an inverted osteochondral plug can be used to backfill the portal.

2.
Cartilage ; 13(1_suppl): 928S-936S, 2021 12.
Article in English | MEDLINE | ID: mdl-33855864

ABSTRACT

OBJECTIVE: To compare radius of curvature (RoC) of distal femur osteochondral autograft transfer (OAT) donor sites from the intercondylar notch and trochlear ridge with recipient sites on the distal and posterior condyles and evaluate differences between recipient sites. DESIGN: Nineteen cadaveric femurs were scanned with a 3-dimensional high-resolution sensor. Donor regions included the lateral (LTR) and medial trochlear ridges (MTR), and the lateral (LICN) and medial intercondylar notch (MICN). Recipient regions analyzed were the distal medial (DMFC), posterior medial (PMFC), distal lateral (DLFC), and posterior lateral femur condyle (PLFC). Six-millimeter OAT grafts were simulated, and average RoC of all regions was compared using an analysis of variance. Post hoc testing was performed using Fisher's least significant difference. RESULTS: We found no significant differences in RoC of the LICN compared with all 4 recipient sites (P = 0.19, 0.97, 0.11, and 0.75 for DLFC, PLFC, DMFC, and PMFC, respectively) or the LTR and MTR to the posterior condyles (LTR vs. PLFC and PMFC; P = 0.72, 0.47, MTR vs. PLFC and PMFC P = 0.39, 0.22, respectively). Significant differences were found for RoC of the MICN compared with each recipient site (P < 0.001) and between distal and posterior femoral condyles (DLFC vs. PLFC, P = 0.016; DMFC vs. PMFC, P = 0.023). CONCLUSION: The LICN is the ideal donor option for all recipient sites on the femoral condyles with respect to RoC of 6-mm OAT plugs. The MTR and LTR were acceptable donor sources for the posterior condyles, while the MICN was a poor match for all recipient sites. Additionally, the distal femur condyle and posterior femur condyle have different RoCs.


Subject(s)
Autografts , Femur/surgery , Intra-Articular Fractures , Radius , Transplant Donor Site , Aged , Cadaver , Female , Humans , Knee , Male , Middle Aged , Transplantation, Autologous
3.
Arthrosc Tech ; 10(10): e2357-e2363, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34754745

ABSTRACT

This article reviews a technique for arthroscopic fixation of an osteochondritis dissecans fragment with bone marrow aspirate concentrate augmentation. This technique involves safe harvest of bone marrow arthroscopically from the intercondylar notch, proper preparation and debridement of the parent bone, reduction of the progeny osteochondritis dissecans fragment, insertion of the bone marrow aspirate concentrate, and placement of multiple headless compression screws for fixation.

4.
Arthrosc Tech ; 9(7): e953-e957, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32714804

ABSTRACT

The purpose of this paper is to describe the rebar repair as a technique for repair of radial meniscus tears and compare the rebar technique with current techniques used for meniscus repairs. This technique consists of 4 sutures placed with the inside-out technique. First, the vertical mattress reinforcement sutures are placed anteriorly and posteriorly to the tear. Then, 2 parallel horizontal sutures are placed directly in juxtaposition to the vertical sutures, ensuring the needles pass on the side of the reinforcing stitch away from the tear. This technique is less technically challenging than other meniscus repair techniques that require drilling of a transtibial tunnel. Overall, the rebar technique offers a more optimal way for stabilizing the meniscus by using 2 reinforcement sutures that run with the circumferential fibers to help restore the natural hoop stress of the meniscus. Also, the placement of the vertical mattress sutures in the rebar technique offers more direct reinforcement to the horizontal mattress sutures as compared with other techniques, which reduces the risk of pull-out tears.

5.
Clin Biomech (Bristol, Avon) ; 77: 105065, 2020 07.
Article in English | MEDLINE | ID: mdl-32504897

ABSTRACT

BACKGROUND: Newer repair techniques of anterior cruciate ligament tears, including augmentation with internal brace, have shown promising clinical results. Few biomechanical studies exist comparing anterior cruciate ligament repair only versus repair with internal brace. The purpose of this study was to compare the load to failure and stiffness of anterior cruciate ligament repair with internal brace augmentation versus repair-only. METHODS: Proximal femoral avulsion type anterior cruciate ligament injuries were created in 20 cadaver knees. Anterior cruciate ligament repair-only or repair with internal brace was performed using arthroscopic tools. Load to failure and failure modes were collected, with calculations of stiffness and energy to failure performed. FINDINGS: The average load to failure for the internal brace group was higher than the repair-only group: 693 N (SD 248) versus 279 N (SD 91), P = .002. The stiffness and energy to failure values were higher for the internal brace group than the repair-only group: 83 N/mm versus 58 N/mm, P = .02 and 16.88 J (SD 12.44) versus 6.91 J (SD 2.49), P = .04, respectively. Failure modes differed between groups (P = .00097) with 80% failure in the repair-only due to suture pull through the anterior cruciate ligament and 90% failure in the internal brace group due to suture button pull through the femur. INTERPRETATION: There was higher load to failure, stiffness, and energy to failure for the internal brace group compared to the repair-only group, and a high positive correlation between bone density and load to failure for the internal brace group. CLINICAL SIGNIFICANCE: Anterior cruciate ligament repair with internal brace augmentation demonstrates significantly higher load to failure. It may be a useful adjunct to protect the anterior cruciate ligament repair from failure during the early stages of healing.


Subject(s)
Anterior Cruciate Ligament Reconstruction/methods , Braces , Mechanical Phenomena , Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Reconstruction/instrumentation , Biomechanical Phenomena , Cadaver , Female , Humans
6.
J Am Acad Orthop Surg ; 28(11): 436-450, 2020 Jun 01.
Article in English | MEDLINE | ID: mdl-32304401

ABSTRACT

The novel coronavirus pandemic, also known as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has placed an immense strain on healthcare systems across the entire world. Consequently, multiple federal and state governments have placed restrictions on hospitals such as limiting "elective surgery" and recommending social or physical distancing. We review the literature on several areas that have been affected including surgical selection, inpatient care, and physician well-being. These areas affecting inpatient paradigms include surgical priority, physical or social distancing, file sharing for online clinical communications, and physician wellness. During this crisis, it is important that orthopaedic departments place an emphasis on personnel safety and slowing the spread of the virus so that the department can still maintain vital functions. Physical distancing and emerging technologies such as inpatient telemedicine and online file sharing applications can enable orthopaedic programs to still function while attempting to protect medical staff and patients from the novel coronavirus spread. This literature review sought to provide evidence-based guidance to orthopaedic departments during an unprecedented time. Orthopaedic surgeons should follow the Centers for Disease Control and Prevention guidelines, wear personal protective equipment (PPE) when appropriate, have teams created using physical distancing, understand the department's policy on elective surgery, and engage in routines which enhance physician wellness.


Subject(s)
Communicable Disease Control/organization & administration , Coronavirus Infections , Pandemics/prevention & control , Personal Protective Equipment/statistics & numerical data , Pneumonia, Viral , Safety Management/organization & administration , COVID-19 , Coronavirus Infections/epidemiology , Elective Surgical Procedures/methods , Elective Surgical Procedures/statistics & numerical data , Female , Humans , Inpatients/statistics & numerical data , Male , Occupational Health , Orthopedic Procedures/statistics & numerical data , Orthopedic Procedures/trends , Patient Isolation/methods , Patient Safety , Patient Selection , Program Development , Program Evaluation , United States
7.
Arthrosc Sports Med Rehabil ; 2(5): e683-e696, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32838329

ABSTRACT

The COVID-19 pandemic swept across the world, altering the structure and existence of graduate medical education programs across all disciplines. Orthopaedic residency programs can adapt during these unprecedented times to continue providing meaningful education to trainees and to continue providing high-quality patient care, all while keeping both residents and patients safe from disease. The purpose of this review was to evaluate the literature and describe evidence-based changes that can be made in an orthopaedic residency program to ensure patient and resident safety while sustaining the principles of graduate medical education during the COVID-19 pandemic. We describe measures that can be enacted now or during future pandemics, including workforce and occupational modifications, personal protective equipment, telemedicine, online didactic education, resident wellness, return to elective surgery, and factors affecting medical students and fellows. After a review of these strategies, programs can make changes for sustainable improvements and adapt to be ready for second-wave events or future pandemics. LEVEL OF EVIDENCE: Level V.

8.
Orthop J Sports Med ; 8(10): 2325967120954808, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33062760

ABSTRACT

BACKGROUND: Patellar tendon ruptures have routinely been repaired with transosseous suture tunnels. The use of knotless suture anchors for repair has been suggested as an alternative. PURPOSE: To compare the load to failure and gap formation of patellar tendon repair at the inferior pole of the patella with knotless suture anchor tape versus transosseous sutures. A secondary objective was to investigate whether either technique shows an association between bone density and load to failure. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 20 human tibias with attached patellar and quadriceps tendons were sharply incised at the bone-tendon junction at the inferior pole of the patella. A total of 10 tendons were repaired using 2 knotless suture anchors in the inferior pole of the patella and a single suture tape with 2 core sutures. The other 10 tendons were repaired using No. 2 suture passed through 3 transosseous tunnels. A distracting force was then applied through the suture in the quadriceps tendon. Gap distance through load cycling at the repair site and maximum load at repair failure were then measured. Bone density was measured using computed tomography scanning. RESULTS: No difference was found in the mean load to failure of knotless patellar tendon repair versus transosseous suture repair (367.6 ± 112.2 vs 433.9 ± 99 N, respectively; P = .12). After 250 cycles, the mean repair site gap distance was 0.85 ± 0.45 mm for the knotless patellar tendon repair versus 2.94 ± 2.03 mm for the transosseous suture repair (P = .03). A small correlation, although not statistically significant, was found between bone density and load to failure for the knotless tape repair (R 2 = 0.228; P = .66). No correlation was found between bone density and load to failure for the transosseous repair (R 2 = 0.086; P = .83). CONCLUSION: Suture tape repair with knotless anchors for repair of patellar tendon rupture has comparable load to failure with less gap formation than transosseous suture repair. There is a small correlation between bone density and failure load for knotless anchor repair, which may benefit from further investigation. CLINICAL RELEVANCE: Using knotless suture anchors for patellar tendon rupture repair would allow for a smaller incision, less dissection, and likely shorter operating time.

9.
JBJS Case Connect ; 10(3): e19.00564, 2020.
Article in English | MEDLINE | ID: mdl-32910618

ABSTRACT

CASE: We report a case of a right knee lateral bucket-handle meniscal tear repair in a 25-year-old woman bilateral below-knee amputee. At the 4-year follow-up, the patient was ambulatory in a prosthesis with a successful outcome. CONCLUSION: Meniscus repair in below-knee amputees requires careful evaluation and surgical management. Specific consideration should be given to evaluating limb alignment, maintaining the stump integrity, surgical technique, modified bracing, and rehabilitation. This case report demonstrates that bucket-handle meniscus repair can be successful in a below-knee amputee.


Subject(s)
Amputees , Arthroscopy/methods , Tibial Meniscus Injuries/surgery , Adult , Female , Humans , Magnetic Resonance Imaging , Tibial Meniscus Injuries/diagnostic imaging
10.
J Exp Orthop ; 6(1): 38, 2019 Aug 22.
Article in English | MEDLINE | ID: mdl-31440855

ABSTRACT

BACKGROUND: Radial meniscus tears can cause the meniscus to be completely incompetent. This serious type of meniscus tear can be difficult to repair. Techniques have been developed that juxtapose the meniscus tear edges and are able to withstand high loads. The purpose of this study was to determine the load to failure of a reinforced suture bar repair (Rebar Repair) for radial meniscus tear and compare it to the parallel suture technique and cross-stitch technique and to compare mode of failure among all three groups. The hypothesis was that the Rebar Repair will have a higher load to failure than both the parallel technique and the cross-stitch technique and that the Rebar Repair would have a lower rate of suture cutting through the meniscus. METHODS: Forty-eight menisci were tested from 24 human knee specimens, with 16 menisci in each group evenly distributed between medial and lateral menisci. Radial mid body meniscal tears were recreated and repaired with one of three inside-out techniques: the 2-parallel suture technique, 2 cross-stitch sutures, and the Rebar Repair. The specimens were cycled between 5 N to 30 N and axially loaded to failure perpendicularly across the repair site. RESULTS: The average load to failure of the parallel group, cross-stitch group and Rebar Repair was 85.5 N ± 22.0, 76.2 N ± 28.8 and 124.1 N ± 27.1 respectively. The Rebar Repair had a higher load to failure than the parallel group (p < 0.01) and cross-stitch group (p < 0.01). There was no difference in the load to failure between the cross-stitch and parallel group (p = 0.49). The failure mechanism was different when comparing the 3 groups (p < 0.01). The predominant mode of failure for both the parallel and cross-stitch group was suture cutout through the meniscus (88% and 94% respectively). The Rebar Repair failed due to suture rupture in 50% and suture cutout through the meniscus in 50%. CONCLUSION: The Rebar Repair for radial meniscus tear has a higher load to failure and a lower rate of suture cutout through the meniscus than the parallel technique and cross-stitch technique. CLINICAL RELEVANCE: Radial meniscus tears lead to decreased hoop stresses of the meniscus and effectively a non-functional meniscus. Newer techniques may have a higher load to failure leading to more successful repairs.

11.
Hand (N Y) ; 12(6): 591-596, 2017 11.
Article in English | MEDLINE | ID: mdl-28719974

ABSTRACT

BACKGROUND: The aim of the study is to determine the accuracy of hand injections with and without the aid of ultrasound (U/S) into the carpal tunnel, thumb carpometacarpal (CMC) joint, first dorsal compartment (DC) and the radiocarpal (RC) joint. METHODS: Four participants of various level of experience injected the carpal tunnel, thumb CMC, first DC, and RC joint into 40 fresh frozen cadaver specimens with blue dye and radiographic contrast. Participants 1 and 2 were injected without U/S guidance, and participants 3 and 4 were injected with U/S guidance. A successful injection was determined by both fluoroscopy and dissection/direct observation. Additional information was recorded for each injection such as median nerve infiltration and evidence of thumb CMC arthrosis. RESULTS: The overall accuracy for carpal tunnel, thumb CMC, first DC, and RC injections were 95%, 63%, 90%, and 90%, respectively. Success was compared with and without U/S guidance. Success rates were similar for each injection site, except the thumb CMC joint, where U/S participants had 25% higher accuracy. In the setting of thumb CMC arthrosis, the incidence of success was 38% for participants with no U/S aid and 72% for participants with U/S aid. There was a significant difference between participants who used U/S with the participant with more U/S experience being more successful. CONCLUSION: Carpal tunnel, first DC, and RC injections had an accuracy of greater than 90%. Thumb CMC injections have a lower accuracy (63%) and one can improve accuracy with U/S. The accuracy of U/S-guided injections is dependent on the user and their experience.


Subject(s)
Carpometacarpal Joints/diagnostic imaging , Injections, Intra-Articular/methods , Ultrasonography, Interventional , Wrist Joint/diagnostic imaging , Cadaver , Clinical Competence , Coloring Agents , Contrast Media , Humans
SELECTION OF CITATIONS
SEARCH DETAIL