ABSTRACT
Conventional air quality monitoring systems, such as gas analysers, are commonly used in many developed and developing countries to monitor air quality. However, these techniques have high costs associated with both installation and maintenance. One possible solution to complement these techniques is the application of low-cost air quality sensors (LAQSs), which have the potential to give higher spatial and temporal data of gas pollutants with high precision and accuracy. In this paper, we present DiracSense, a custom-made LAQS that monitors the gas pollutants ozone (O3), nitrogen dioxide (NO2), and carbon monoxide (CO). The aim of this study is to investigate its performance based on laboratory calibration and field experiments. Several model calibrations were developed to improve the accuracy and performance of the LAQS. Laboratory calibrations were carried out to determine the zero offset and sensitivities of each sensor. The results showed that the sensor performed with a highly linear correlation with the reference instrument with a response-time range from 0.5 to 1.7 min. The performance of several calibration models including a calibrated simple equation and supervised learning algorithms (adaptive neuro-fuzzy inference system or ANFIS and the multilayer feed-forward perceptron or MLP) were compared. The field calibration focused on O3 measurements due to the lack of a reference instrument for CO and NO2. Combinations of inputs were evaluated during the development of the supervised learning algorithm. The validation results demonstrated that the ANFIS model with four inputs (WE OX, AE OX, T, and NO2) had the lowest error in terms of statistical performance and the highest correlation coefficients with respect to the reference instrument (0.8 < r < 0.95). These results suggest that the ANFIS model is promising as a calibration tool since it has the capability to improve the accuracy and performance of the low-cost electrochemical sensor.
ABSTRACT
Background: The success of mobile apps in improving the lifestyle of patients with noncommunicable diseases through self-management interventions is contingent upon the emerging growth in this field. While users of mobile health (mHealth) apps continue to grow in number, little is known about the quality of available apps that provide self-management for common noncommunicable diseases such as diabetes, hypertension, and obesity. Objective: We aimed to investigate the availability, characteristics, and quality of mHealth apps for common noncommunicable disease health management that included dietary aspects (based on the developer's description), as well as their features for promoting health outcomes and self-monitoring. Methods: A systematic search of English-language apps on the Google Play Store (Google LLC) and Apple App Store (Apple Inc) was conducted between August 7, 2022, and September 13, 2022. The search terms used included weight management, obesity, diabetes, hypertension, cardiovascular diseases, stroke, and diet. The selected mHealth apps' titles and content were screened based on the description that was provided. Apps that were not designed with self-management features were excluded. We analyzed the mHealth apps by category and whether they involved health care professionals, were based on scientific testing, and had self-monitoring features. A validated and multidimensional tool, the Mobile App Rating Scale (MARS), was used to evaluate each mHealth app's quality based on a 5-point Likert scale from 1 (inadequate) to 5 (excellent). Results: Overall, 42 apps were identified. Diabetes-specific mHealth apps accounted for 7% (n=3) of the market, hypertension apps for 12% (n=5), and general noncommunicable disease management apps for 21% (n=9). About 38% (n=16) of the apps were for managing chronic diseases, while 74% (n=31) were for weight management. Self-management features such as weight tracking, BMI calculators, diet tracking, and fluid intake tracking were seen in 86% (n=36) of the apps. Most mHealth apps (n=37, 88%) did not indicate whether there was involvement of health professionals in app development. Additionally, none of the apps reported scientific evidence demonstrating their efficacy in managing health. The overall mean MARS score was 3.2 of 5, with a range of 2.0 to 4.1. Functionality was the best-rated category (mean score 3.9, SD 0.5), followed by aesthetics (mean score 3.2, SD 0.9), information (mean score 3.1, SD 0.7), and engagement (mean score 2.9, SD 0.6). Conclusions: The quality of mHealth apps for managing chronic diseases was heterogeneous, with roughly half of them falling short of acceptable standards for both quality and content. The majority of apps contained scant information about scientific evidence and the developer's history. To increase user confidence and accomplish desired health outcomes, mHealth apps should be optimized with the help of health care professionals. Future studies on mHealth content analysis should focus on other diseases as well.
Subject(s)
Mobile Applications , Noncommunicable Diseases , Mobile Applications/standards , Mobile Applications/statistics & numerical data , Mobile Applications/trends , Humans , Noncommunicable Diseases/therapy , Disease Management , Telemedicine/statistics & numerical data , Telemedicine/standardsABSTRACT
The staggering innovations and emergence of numerous deep learning (DL) applications have forced researchers to reconsider hardware architecture to accommodate fast and efficient application-specific computations. Applications, such as object detection, image recognition, speech translation, as well as music synthesis and image generation, can be performed with high accuracy at the expense of substantial computational resources using DL. Furthermore, the desire to adopt Industry 4.0 and smart technologies within the Internet of Things infrastructure has initiated several studies to enable on-chip DL capabilities for resource-constrained devices. Specialized DL processors reduce dependence on cloud servers, improve privacy, lessen latency, and mitigate bandwidth congestion. As we reach the limits of shrinking transistors, researchers are exploring various application-specific hardware architectures to meet the performance and efficiency requirements for DL tasks. Over the past few years, several software optimizations and hardware innovations have been proposed to efficiently perform these computations. In this article, we review several DL accelerators, as well as technologies with emerging devices, to highlight their architectural features in application-specific integrated circuit (IC) and field-programmable gate array (FPGA) platforms. Finally, the design considerations for DL hardware in portable applications have been discussed, along with some deductions about the future trends and potential research directions to innovate DL accelerator architectures further. By compiling this review, we expect to help aspiring researchers widen their knowledge in custom hardware architectures for DL.
Subject(s)
Deep Learning , Neural Networks, Computer , Computers , SoftwareABSTRACT
The promising chemical, mechanical, and electrical properties of silver from nano scale to bulk level make it useful to be used in a variety of applications in the biomedical and electronic fields. Recently, several methods have been proposed and applied for the small-scale and mass production of silver in the form of nanoparticles, nanowires, and nanofibers. In this research, we have proposed a novel method for the fabrication of silver nano fibers (AgNFs) that is environmentally friendly and can be easily deployed for large-scale production. Moreover, the proposed technique is easy for device fabrication in different applications. To validate the properties, the synthesized silver nanofibers have been examined through Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and X-ray diffraction (XRD). Further, the synthesized silver nanofibers have been deposited over sensors for Relative humidity (RH), Ammonia (NH3), and temperature sensing applications. The sensor was of a resistive type, and found 4.3 kΩ for relative humidity (RH %) 30-90%, 400 kΩ for NH3 (40,000 ppm), and 5 MΩ for temperature sensing (69 °C). The durability and speed of the sensor verified through repetitive, response, and recovery tests of the sensor in a humidity and gas chamber. It was observed that the sensor took 13 s to respond, 27 s to measure the maximum value, and took 33 s to regain its minimum value. Furthermore, it was observed that at lower frequencies and higher concentration of NH3, the response of the device was excellent. Furthermore, the device has linear and repetitive responses, is cost-effective, and is easy to fabricate.
ABSTRACT
BACKGROUND: Diabetic Sensorimotor polyneuropathy (DSPN) is one of the major indelible complications in diabetic patients. Michigan neuropathy screening instrumentation (MNSI) is one of the most common screening techniques used for DSPN, however, it does not provide any direct severity grading system. METHOD: For designing and modeling the DSPN severity grading systems for MNSI, 19 years of data from Epidemiology of Diabetes Interventions and Complications (EDIC) clinical trials were used. Different Machine learning-based feature ranking techniques were investigated to identify the important MNSI features associated with DSPN diagnosis. A multivariable logistic regression-based nomogram was generated and validated for DSPN severity grading using the best performing top-ranked MNSI features. RESULTS: Top-10 ranked features from MNSI features: Appearance of Feet (R), Ankle Reflexes (R), Vibration perception (L), Vibration perception (R), Appearance of Feet (L), 10-gm filament (L), Ankle Reflexes (L), 10-gm filament (R), Bed Cover Touch, and Ulceration (R) were identified as important features for identifying DSPN by Multi-Tree Extreme Gradient Boost model. The nomogram-based prediction model exhibited an accuracy of 97.95% and 98.84% for the EDIC test set and an independent test set, respectively. A DSPN severity score technique was generated for MNSI from the DSPN severity prediction model. DSPN patients were stratified into four severity levels: absent, mild, moderate, and severe using the cut-off values of 17.6, 19.1, 20.5 for the DSPN probability less than 50%, 75%-90%, and above 90%, respectively. CONCLUSIONS: The findings of this work provide a machine learning-based MNSI severity grading system which has the potential to be used as a secondary decision support system by health professionals in clinical applications and large clinical trials to identify high-risk DSPN patients.
Subject(s)
Diabetes Mellitus, Type 2 , Diabetic Neuropathies , Polyneuropathies , Diabetic Neuropathies/diagnosis , Diabetic Neuropathies/epidemiology , Humans , Mass Screening , Michigan , NomogramsABSTRACT
Diabetes foot ulceration (DFU) and amputation are a cause of significant morbidity. The prevention of DFU may be achieved by the identification of patients at risk of DFU and the institution of preventative measures through education and offloading. Several studies have reported that thermogram images may help to detect an increase in plantar temperature prior to DFU. However, the distribution of plantar temperature may be heterogeneous, making it difficult to quantify and utilize to predict outcomes. We have compared a machine learning-based scoring technique with feature selection and optimization techniques and learning classifiers to several state-of-the-art Convolutional Neural Networks (CNNs) on foot thermogram images and propose a robust solution to identify the diabetic foot. A comparatively shallow CNN model, MobilenetV2 achieved an F1 score of â¼95% for a two-feet thermogram image-based classification and the AdaBoost Classifier used 10 features and achieved an F1 score of 97%. A comparison of the inference time for the best-performing networks confirmed that the proposed algorithm can be deployed as a smartphone application to allow the user to monitor the progression of the DFU in a home setting.
Subject(s)
Diabetes Mellitus , Diabetic Foot , Algorithms , Diabetic Foot/diagnostic imaging , Humans , Machine Learning , Neural Networks, Computer , ThermographyABSTRACT
This paper examines the impact of two important geometrical parameters, namely the thickness and source/drain extensions on the performance of low doped p-type double lateral gate junctionless transistors (DGJLTs). The three dimensional Technology Computer-Aided Design simulation is implemented to calculate the characteristics of the devices with different thickness and source/drain extension and based on that, the parameters such as threshold voltage, transconductance and resistance in saturation region are analyzed. In addition, simulation results provide a physical explanation for the variation of device characteristics given by the variation of geometric parameters, mainly based on investigation of the electric field components and the carries density variation. It is shown that, the variation of the carrier density is the main factor which affects the characteristics of the device when the device's thickness is varied. However, the electric field is mainly responsible for variation of the characteristics when the source/drain extension is changed.