Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 58
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Surg Endosc ; 38(7): 4006-4013, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38862822

ABSTRACT

BACKGROUND: Mediumweight (40-60 g/m2) polypropylene (MWPP) mesh has been shown to be safe and effective in CDC class II-III retromuscular ventral hernia repairs (RMVHR). However, MWPP has the potential to fracture, and it is possible that heavyweight (> 75 g/m2) polypropylene mesh has similar outcomes in this context. However, there is limited data on HWPP mesh performance in clean-contaminated and contaminated scenarios. We aimed to compare HWPP to MWPP mesh in CDC class II-III wounds during open RMVHR. METHODS: The Abdominal Core Health Quality Collaborative database was retrospectively queried for a cohort of patients who underwent open RMVHR with MWPP or HWPP mesh placed in CDC class II/III wounds from 2012 to 2023. Mesh types were compared using a 3:1 propensity score-matched analysis. Covariates for matching included CDC classification, BMI, diabetes, smoking within 1 year, hernia, and mesh width. Primary outcome of interest included wound complications. Secondary outcomes included reoperations and readmissions at 30 days. RESULTS: A total of 1496 patients received MWPP or HWPP (1378 vs. 118, respectively) in contaminated RMVHR. After propensity score matching, 351 patients remained in the mediumweight and 117 in the heavyweight mesh group. There were no significant differences in surgical site infection (SSI) rates (13.4% vs. 14.5%, p = 0.877), including deep SSIs (0.3% vs. 0%, p = 1), surgical site occurrence rates (17.9% vs. 22.2%, p = 0.377), surgical site occurrence requiring procedural intervention (16% vs. 17.9%, p = 0.719), mesh removal (0.3% vs. 0%, p = 1), reoperations (4.6% vs. 2.6%, p = 0.428), or readmissions (12.3% vs. 9.4%, p = 0.504) at 30 days. CONCLUSION: HWPP mesh was not associated with increased wound morbidity, mesh excisions, reoperations, or readmissions in the early postoperative period compared with MWPP mesh in open RMVHR for CDC II/III cases. Longer follow-up will be necessary to determine if HWPP mesh may be a suitable alternative to MWPP mesh in contaminated scenarios.


Subject(s)
Hernia, Ventral , Herniorrhaphy , Polypropylenes , Surgical Mesh , Surgical Wound Infection , Humans , Hernia, Ventral/surgery , Retrospective Studies , Surgical Mesh/adverse effects , Male , Female , Herniorrhaphy/methods , Herniorrhaphy/adverse effects , Middle Aged , Surgical Wound Infection/epidemiology , Surgical Wound Infection/etiology , Aged , Treatment Outcome , Patient Readmission/statistics & numerical data , Reoperation/statistics & numerical data , Postoperative Complications/epidemiology , Postoperative Complications/etiology
2.
Surg Endosc ; 38(4): 2019-2026, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38424284

ABSTRACT

INTRODUCTION: Intraperitoneal onlay mesh (IPOM) placement for small to medium-sized hernias has garnered negative attention due to perceived long-term risk of mesh-related complications. However, sparse data exists supporting such claims after minimally invasive (MIS) IPOM repairs and most is hindered by the lack of long-term follow-up. We sought to report long-term outcomes and mesh-related complications of MIS IPOM ventral hernia repairs. METHODS AND PROCEDURES: Adult patients who underwent MIS IPOM ventral hernia repair at our institution were identified in the Abdominal Core Health Quality Collaborative database from October 2013 to October 2020. Outcomes included hernia recurrence and mesh-related complications or reoperations up to 6 years postoperatively. RESULTS: A total of 325 patients were identified. The majority (97.2%) of cases were elective, non-recurrent (74.5%), and CDC class I (99.4%). Mean hernia width was 4.16 ± 3.86 cm. Median follow-up was 3.6 (IQR 2.8-5) years. Surgeon-entered or patient-reported follow-up was available for 253 (77.8%) patients at 3 years or greater postoperatively. One patient experienced an early small bowel obstruction and was reoperated on within 30 days. Two-hundred forty-five radiographic examinations were available up to 6 years postoperatively. Twenty-seven patients had hernia recurrence on radiographic examination up to 6 years postoperatively. During long-term follow-up, two mesh-related complications required reoperations: mesh removed for chronic pain and mesh removal at the time of colon surgery for perforated cancer. Sixteen additional patients required reoperation within 6 years for the following reasons: hernia recurrence (n = 5), unrelated intraabdominal pathology (n = 9), obstructed port site hernia (n = 1), and adhesive bowel obstruction unrelated to the prosthesis (n = 1). The rate of reoperation due to intraperitoneal mesh complications was 0.62% (2/325) with up to 6 year follow-up. CONCLUSION: Intraperitoneal mesh for repair of small to medium-sized hernias has an extremely low rate of long-term mesh-related complications. It remains a safe and durable option for hernia surgeons.


Subject(s)
Digestive System Surgical Procedures , Hernia, Ventral , Incisional Hernia , Intestinal Obstruction , Laparoscopy , Adult , Humans , Surgical Mesh/adverse effects , Hernia, Ventral/surgery , Herniorrhaphy/adverse effects , Prostheses and Implants , Intestinal Obstruction/surgery , Incisional Hernia/surgery , Recurrence
3.
Surg Endosc ; 38(6): 3433-3440, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38710888

ABSTRACT

INTRODUCTION: Fixation of mesh during minimally invasive inguinal hernia repair is thought to contribute to chronic post-herniorrhaphy groin pain (CGP). In contrast to permanent tacks, absorbable tacks are hypothesized to minimize the likelihood of CGP. This study aimed to compare the rates of CGP after laparoscopic inguinal hernia repair between absorbable versus permanent fixation at maximum follow-up. METHODS: This is a post hoc analysis of a randomized controlled trial in patients undergoing laparoscopic inguinal hernia repair (NCT03835351). All patients were contacted at maximum follow-up after surgery to administer EuraHS quality of life (QoL) surveys. The pain and restriction of activity subdomains of the survey were utilized. The primary outcome was rate of CGP, as defined by a EuraHS QoL pain domain score ≥ 4 measured at ≥ 1 year postoperatively. The secondary outcomes were pain and restriction of activity domain scores and hernia recurrence at maximum follow-up. RESULTS: A total of 338 patients were contacted at a mean follow-up of 28 ± 11 months. 181 patients received permanent tacks and 157 patients received absorbable tacks during their repair. At maximum follow-up, the rates of CGP (27 [15%] vs 28 [18%], P = 0.47), average pain scores (1.78 ± 4.38 vs 2.32 ± 5.40, P = 0.22), restriction of activity scores (1.39 ± 4.32 vs 2.48 ± 7.45, P = 0.18), and the number of patients who reported an inguinal bulge (18 [9.9%] vs 15 [9.5%], P = 0.9) were similar between patients with permanent versus absorbable tacks. On multivariable analysis, there was no significant difference in the odds of CGP between the two groups (OR 1.23, 95% CI [0.60, 2.50]). CONCLUSION: Mesh fixation with permanent tacks does not appear to increase the risk of CGP after laparoscopic inguinal hernia repair when compared to fixation with absorbable tacks. Prospective trials are needed to further evaluate this relationship.


Subject(s)
Absorbable Implants , Chronic Pain , Groin , Hernia, Inguinal , Herniorrhaphy , Laparoscopy , Pain, Postoperative , Surgical Mesh , Humans , Hernia, Inguinal/surgery , Laparoscopy/methods , Laparoscopy/adverse effects , Herniorrhaphy/methods , Herniorrhaphy/adverse effects , Male , Pain, Postoperative/etiology , Middle Aged , Female , Groin/surgery , Chronic Pain/etiology , Aged , Quality of Life , Follow-Up Studies , Adult
4.
Surgeon ; 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38862376

ABSTRACT

INTRODUCTION: As hospitals strive to reduce their environmental footprint, there is an ongoing debate over the environmental implications of reusable versus disposable linens in operating rooms (ORs). This research aimed to compare the environmental impact of reusable versus single-use OR bed covers and lift sheets using life cycle assessment (LCA) methodology. METHODS: LCA is an established tool with rigorous methodology that uses science-based processes to measure environmental impact. This study compared the impacts of three independent system scenarios at a single large academic hospital: reusable bed covers with 50 laundry cycles and subsequent landfill disposal (System 1), single-use bed covers with waste landfill disposal (System 2), and single-use bed covers with waste disposal using incineration (System 3). RESULTS: The total carbon footprint of System 1 for 50 uses was 19.83 â€‹kg carbon dioxide equivalents (CO2-eq). System 2 generated 64.99 â€‹kg CO2-eq. For System 3, the total carbon footprint was 108.98 â€‹kg CO2-eq. The raw material extraction for all the material to produce an equivalent 50 single-use OR bed cover kits was tenfold more carbon-intensive than the reusable bed cover. Laundering one reusable OR bed cover 50 times was more carbon intensive (12.12 â€‹kg CO2-eq) than landfill disposal of 50 single-use OR bed covers (2.52 â€‹kg CO2-eq). DISCUSSION: Our analysis demonstrates that one reusable fabric-based OR bed cover laundered 50 times, despite the carbon and water-intensive laundering process, exhibits a markedly lower carbon footprint than its single-use counterparts. The net difference is 45.16 â€‹kg CO2-eq, equivalent to driving 115 miles in an average gasoline-powered passenger vehicle. This stark contrast underscores the efficacy of adopting reusable solutions to mitigate environmental impact within healthcare facilities.

5.
Surg Endosc ; 37(12): 9347-9350, 2023 12.
Article in English | MEDLINE | ID: mdl-37640951

ABSTRACT

BACKGROUND: Tension-free abdominal closure is a primary tenet of laparotomy. But this concept neglects the baseline tension of the abdominal wall. Ideally, abdominal closure should be tailored to restore native physiologic tension. We sought to quantify the tension needed to re-establish the linea alba in patients undergoing exploratory laparotomy. METHODS: Patients without ventral hernias undergoing laparotomy at a single institution were enrolled from December 2021 to September 2022. Patients who had undergone prior laparotomy were included. Exclusion criteria included prior incisional hernia repair, presence of an ostomy, large-volume ascites, and large intra-abdominal tumors. After laparotomy, a sterilizable tensiometer measured the quantitative tension needed to bring the fascial edge to the midline. Outcomes included the force needed to bring the fascial edge to the midline and the association of BMI, incision length, and prior lateral incisions on abdominal wall tension. RESULTS: This study included 86 patients, for a total of 172 measurements (right and left for each patient). Median patient BMI was 26.4 kg/m2 (IQR 22.9;31.5), and median incision length was 17.0 cm (IQR 14;20). Mean tension needed to bring the myofascial edge to the midline was 0.97 lbs. (SD 1.03). Mixed-effect multivariable regression modeling found that increasing BMI and greater incision length were associated with higher abdominal wall tension (coefficient 0.04, 95% CI [0.01,0.07]; p = 0.004, coefficient 0.04, 95% CI [0.01,0.07]; p = 0.006, respectively). CONCLUSION: In patients undergoing laparotomy, the tension needed to re-establish the linea alba is approximately 1.94 lbs. A quantitative understanding of baseline abdominal wall tension may help surgeons tailor abdominal closure in complex scenarios, including ventral hernia repairs and open or burst abdomens.


Subject(s)
Abdominal Wall , Hernia, Ventral , Surgical Wound , Humans , Abdominal Wall/surgery , Hernia, Ventral/surgery , Abdominal Muscles/surgery , Laparotomy , Fascia
6.
Surg Endosc ; 37(1): 723-728, 2023 01.
Article in English | MEDLINE | ID: mdl-35578051

ABSTRACT

INTRODUCTION: Robotic inguinal hernia repair is growing in popularity among general surgeons despite little high-quality evidence supporting short- or long-term advantages over traditional laparoscopic inguinal hernia repair. The original RIVAL trial showed increased operative time, cost, and surgeon frustration for the robotic approach without advantages over laparoscopy. Here we report the 1- and 2-year outcomes of the trial. METHODS: This is a multi-center, patient-blinded, randomized clinical study conducted at six sites from 2016 to 2019, comparing laparoscopic versus robotic transabdominal preperitoneal (TAPP) inguinal hernia repair with follow-up at 1 and 2 years. Outcomes include pain (visual analog scale), neuropathic pain (Leeds assessment of neuropathic symptoms and signs pain scale), wound morbidity, composite hernia recurrence (patient-reported and clinical exam), health-related quality of life (36-item short-form health survey), and physical activity (physical activity assessment tool). RESULTS: Early trial participation included 102 patients; 83 (81%) completed 1-year follow-up (45 laparoscopic vs. 38 robotic) and 77 (75%) completed 2-year follow-up (43 laparoscopic vs. 34 robotic). At 1 and 2 years, pain was similar for both groups. No patients in either treatment arm experienced neuropathic pain. Health-related quality of life and physical activity were similar for both groups at 1 and 2 years. No long-term wound morbidity was seen for either repair type. At 2 years, there was no difference in hernia recurrence (1 laparoscopic vs. 1 robotic; P = 1.0). CONCLUSIONS: Laparoscopic and robotic inguinal hernia repairs have similar long-term outcomes when performed by surgeons with experience in minimally invasive inguinal hernia repairs.


Subject(s)
Hernia, Inguinal , Laparoscopy , Neuralgia , Robotic Surgical Procedures , Humans , Hernia, Inguinal/surgery , Quality of Life , Herniorrhaphy , Neuralgia/surgery , Surgical Mesh
7.
J Chem Phys ; 149(7): 072321, 2018 Aug 21.
Article in English | MEDLINE | ID: mdl-30134701

ABSTRACT

We present the reservoir pH replica exchange (R-pH-REM) method for constant pH simulations. The R-pH-REM method consists of a two-step procedure; the first step involves generation of one or more reservoirs of conformations. Each reservoir is obtained from a standard or enhanced molecular dynamics simulation with a constrained (fixed) protonation state. In the second step, fixed charge constraints are relaxed, as the structures from one or more reservoirs are periodically injected into a constant pH or a pH-replica exchange (pH-REM) simulation. The benefit of this two-step process is that the computationally intensive part of conformational search can be decoupled from constant pH simulations, and various techniques for enhanced conformational sampling can be applied without the need to integrate such techniques into the pH-REM framework. Simulations on blocked Lys, KK, and KAAE peptides were used to demonstrate an agreement between pH-REM and R-pH-REM simulations. While the reservoir simulations are not needed for these small test systems, the real need arises in cases when ionizable molecules can sample two or more conformations separated by a large energy barrier, such that adequate sampling is not achieved on a time scale of standard constant pH simulations. Such problems might be encountered in protein systems that exploit conformational transitions for function. A hypothetical case is studied, a small molecule with a large torsional barrier; while results of pH-REM simulations depend on the starting structure, R-pH-REM calculations on this model system are in excellent agreement with a theoretical model.


Subject(s)
Algorithms , Dipeptides/chemistry , Lysine/chemistry , Oligopeptides/chemistry , Hydrogen-Ion Concentration , Molecular Dynamics Simulation , Protein Conformation
8.
J Comput Chem ; 36(1): 62-7, 2015 Jan 05.
Article in English | MEDLINE | ID: mdl-25362883

ABSTRACT

Recent availability of large publicly accessible databases of chemical compounds and their biological activities (PubChem, ChEMBL) has inspired us to develop a web-based tool for structure activity relationship and quantitative structure activity relationship modeling to add to the services provided by CHARMMing (www.charmming.org). This new module implements some of the most recent advances in modern machine learning algorithms-Random Forest, Support Vector Machine, Stochastic Gradient Descent, Gradient Tree Boosting, so forth. A user can import training data from Pubchem Bioassay data collections directly from our interface or upload his or her own SD files which contain structures and activity information to create new models (either categorical or numerical). A user can then track the model generation process and run models on new data to predict activity.


Subject(s)
Internet , Quantitative Structure-Activity Relationship , User-Computer Interface , Algorithms , Artificial Intelligence , Databases, Factual , Models, Molecular , Software
9.
PLoS Comput Biol ; 10(7): e1003739, 2014 Jul.
Article in English | MEDLINE | ID: mdl-25058418

ABSTRACT

A module for fast determination of reduction potentials, E°, of redox-active proteins has been implemented in the CHARMM INterface and Graphics (CHARMMing) web portal (www.charmming.org). The free energy of reduction, which is proportional to E°, is composed of an intrinsic contribution due to the redox site and an environmental contribution due to the protein and solvent. Here, the intrinsic contribution is selected from a library of pre-calculated density functional theory values for each type of redox site and redox couple, while the environmental contribution is calculated from a crystal structure of the protein using Poisson-Boltzmann continuum electrostatics. An accompanying lesson demonstrates a calculation of E°. In this lesson, an ionizable residue in a [4Fe-4S]-protein that causes a pH-dependent E° is identified, and the E° of a mutant that would test the identification is predicted. This demonstration is valuable to both computational chemistry students and researchers interested in predicting sequence determinants of E° for mutagenesis.


Subject(s)
Computational Biology/education , Computational Biology/methods , Electron Transport , Internet , Proteins/chemistry , Proteins/metabolism , Oxidation-Reduction , Thermodynamics
10.
PLoS Comput Biol ; 10(7): e1003738, 2014 Jul.
Article in English | MEDLINE | ID: mdl-25058338

ABSTRACT

A lesson utilizing a coarse-grained (CG) Go-like model has been implemented into the CHARMM INterface and Graphics (CHARMMing) web portal (www.charmming.org) to the Chemistry at HARvard Macromolecular Mechanics (CHARMM) molecular simulation package. While widely used to model various biophysical processes, such as protein folding and aggregation, CG models can also serve as an educational tool because they can provide qualitative descriptions of complex biophysical phenomena for a relatively cheap computational cost. As a proof of concept, this lesson demonstrates the construction of a CG model of a small globular protein, its simulation via Langevin dynamics, and the analysis of the resulting data. This lesson makes connections between modern molecular simulation techniques and topics commonly presented in an advanced undergraduate lecture on physical chemistry. It culminates in a straightforward analysis of a short dynamics trajectory of a small fast folding globular protein; we briefly describe the thermodynamic properties that can be calculated from this analysis. The assumptions inherent in the model and the data analysis are laid out in a clear, concise manner, and the techniques used are consistent with those employed by specialists in the field of CG modeling. One of the major tasks in building the Go-like model is determining the relative strength of the nonbonded interactions between coarse-grained sites. New functionality has been added to CHARMMing to facilitate this process. The implementation of these features into CHARMMing helps automate many of the tedious aspects of constructing a CG Go model. The CG model builder and its accompanying lesson should be a valuable tool to chemistry students, teachers, and modelers in the field.


Subject(s)
Computational Biology/education , Computational Biology/methods , Internet , Protein Folding , Software , Molecular Dynamics Simulation , Proteins/chemistry , Proteins/metabolism , User-Computer Interface
11.
PLoS Comput Biol ; 10(7): e1003719, 2014 Jul.
Article in English | MEDLINE | ID: mdl-25057988

ABSTRACT

This article describes the development, implementation, and use of web-based "lessons" to introduce students and other newcomers to computer simulations of biological macromolecules. These lessons, i.e., interactive step-by-step instructions for performing common molecular simulation tasks, are integrated into the collaboratively developed CHARMM INterface and Graphics (CHARMMing) web user interface (http://www.charmming.org). Several lessons have already been developed with new ones easily added via a provided Python script. In addition to CHARMMing's new lessons functionality, web-based graphical capabilities have been overhauled and are fully compatible with modern mobile web browsers (e.g., phones and tablets), allowing easy integration of these advanced simulation techniques into coursework. Finally, one of the primary objections to web-based systems like CHARMMing has been that "point and click" simulation set-up does little to teach the user about the underlying physics, biology, and computational methods being applied. In response to this criticism, we have developed a freely available tutorial to bridge the gap between graphical simulation setup and the technical knowledge necessary to perform simulations without user interface assistance.


Subject(s)
Computational Biology/education , Computer Simulation , Computer-Assisted Instruction/methods , Databases, Protein , Internet , Models, Molecular , Software
12.
J Chem Inf Model ; 55(11): 2308-14, 2015 Nov 23.
Article in English | MEDLINE | ID: mdl-26509288

ABSTRACT

Proteins often exist only as apo structures (unligated) in the Protein Data Bank, with their corresponding holo structures (with ligands) unavailable. However, apoproteins may not represent the amino-acid residue arrangement upon ligand binding well, which is especially problematic for molecular docking. We developed the ProBiS-CHARMMing web interface by connecting the ProBiS ( http://probis.cmm.ki.si ) and CHARMMing ( http://www.charmming.org ) web servers into one functional unit that enables prediction of protein-ligand complexes and allows for their geometry optimization and interaction energy calculation. The ProBiS web server predicts ligands (small compounds, proteins, nucleic acids, and single-atom ligands) that may bind to a query protein. This is achieved by comparing its surface structure against a nonredundant database of protein structures and finding those that have binding sites similar to that of the query protein. Existing ligands found in the similar binding sites are then transposed to the query according to predictions from ProBiS. The CHARMMing web server enables, among other things, minimization and potential energy calculation for a wide variety of biomolecular systems, and it is used here to optimize the geometry of the predicted protein-ligand complex structures using the CHARMM force field and to calculate their interaction energies with the corresponding query proteins. We show how ProBiS-CHARMMing can be used to predict ligands and their poses for a particular binding site, and minimize the predicted protein-ligand complexes to obtain representations of holoproteins. The ProBiS-CHARMMing web interface is freely available for academic users at http://probis.nih.gov.


Subject(s)
Proteins/metabolism , Software , Binding Sites , Databases, Protein , Internet , Ligands , Models, Biological , Molecular Docking Simulation , Protein Binding , Protein Conformation , Protein Interaction Maps , Proteins/chemistry , Small Molecule Libraries/chemistry , Small Molecule Libraries/pharmacology , Thermodynamics
13.
J Chem Phys ; 142(6): 064501, 2015 Feb 14.
Article in English | MEDLINE | ID: mdl-25681917

ABSTRACT

The anomalous behavior in the partial molar volumes of ethanol-water mixtures at low concentrations of ethanol is studied using molecular dynamics simulations. Previous work indicates that the striking minimum in the partial molar volume of ethanol VE as a function of ethanol mole fraction XE is determined mainly by water-water interactions. These results were based on simulations that used one water model for the solute-water interactions but two different water models for the water-water interactions. This is confirmed here by using two more water models for the water-water interactions. Furthermore, the previous work indicates that the initial decrease is caused by association of the hydration shells of the hydrocarbon tails, and the minimum occurs at the concentration where all of the hydration shells are touching each other. Thus, the characteristics of the hydration of the tail that cause the decrease and the features of the water models that reproduce this type of hydration are also examined here. The results show that a single-site multipole water model with a charge distribution that mimics the large quadrupole and the p-orbital type electron density out of the molecular plane has "brittle" hydration with hydrogen bonds that break as the tails touch, which reproduces the deep minimum. However, water models with more typical site representations with partial charges lead to flexible hydration that tends to stay intact, which produces a shallow minimum. Thus, brittle hydration may play an essential role in hydrophobic association in water.

14.
J Surg Educ ; 81(7): 912-917, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38749811

ABSTRACT

OBJECTIVE: Since the inception of Ken Lee Memorial Fellowship (KLMF) in 2013, our institution has achieved 10 years of trainee led sustainability projects. The ability of health care organizations to drive sustainability depends on organizational and human capacity. This qualitative study presents the first decade of sustainability fellows' projects, the challenges associated with implementing them, and the environmental and cost impact of these initiatives. DESIGN, SETTING, PARTICIPANTS: All residents in the General Surgery residency program at the Cleveland Clinic, a quaternary hospital, regardless of postgraduate year (PGY) level, are invited to apply for the KLMF program with a short project proposal. One fellow is selected per year. Each project since the program's inception was reviewed qualitatively, relying on data derived from observation, interview of prior fellows, and supervising staff, and analysis of documentation from the annual fellow presentation and abstract, Grand Rounds recording, and fellowship leadership. RESULTS: A targeted approach by each sustainability fellow is encouraged, with the following action cycle for change implementation throughout the 1-year fellowship: identification and discovery of an issue, collaborative planning of an intervention, implementation of the intervention, and evaluation. Projects range from water and waste reduction to education of surgical staff, with positive implications for environmental stewardship in our hospital. However, multiple barriers to completing, scaling, and maintaining sustainability initiatives remain, as demonstrated by challenges faced by our Ken Lee Fellows. CONCLUSIONS: Our goal is that this intensive educational experience within the framework of a graduate medical education curriculum will ensure future generations of surgeons who are thoughtful leaders in environmental stewardship.


Subject(s)
Fellowships and Scholarships , General Surgery , Leadership , Fellowships and Scholarships/organization & administration , Humans , General Surgery/education , Internship and Residency/organization & administration , Education, Medical, Graduate , Conservation of Natural Resources
15.
Surgery ; 175(3): 799-805, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37716868

ABSTRACT

BACKGROUND: Mesh has been the acceptable standard for incisional hernia repair regardless of hernia size. It is not clear whether there is a size of incisional hernias in whom repair would be best performed without mesh. This study aims to compare outcomes of mesh versus suture repairs for incisional hernias <2 cm in size. METHODS: Incisional hernia repairs from 2012 to 2021 for hernias ≤2 cm in width were queried from the Abdominal Core Health Quality Collaborative. Those with 1-year follow up were considered. Hernia recurrence was defined using composite hernia recurrence, which combines both clinical and patient reported outcomes. Propensity score matching was performed between mesh and non-mesh using body mass index, smoking, diabetes, and drains as covariates. RESULTS: A total of 352 patients met inclusion criteria. After propensity score matching, there were 132 repairs with mesh and 71 without. There was no difference in recurrence rates at 1 year between mesh and non-mesh repairs (15% vs 24%, P = .12). Mesh was associated with a higher rate of 30-day postoperative complications (11% vs 1%, P = .017). There were no differences in 1-year quality of life scores. CONCLUSION: The repair of incisional hernias ≤2 cm without mesh results in similar recurrence rates, similar quality of life scores, and lower postoperative early complications compared with repairs with mesh. Our findings suggest that there may be select patients with small incisional hernias that could reasonably undergo incisional hernia repair without mesh. Longer-term follow-up is needed to confirm ideal candidates and durability of these repairs.


Subject(s)
Hernia, Ventral , Incisional Hernia , Humans , Incisional Hernia/surgery , Incisional Hernia/complications , Surgical Mesh/adverse effects , Propensity Score , Quality of Life , Herniorrhaphy/adverse effects , Herniorrhaphy/methods , Hernia, Ventral/surgery , Hernia, Ventral/etiology , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Complications/surgery , Abdominal Core , Sutures/adverse effects , Recurrence
16.
Surgery ; 175(3): 806-812, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37741776

ABSTRACT

BACKGROUND: Morbid obesity, with a body mass index 35 kg/m2, is a commonly used cutoff for denying elective transversus abdominis release. Although obesity is linked to short-term wound morbidity, its effect on long-term outcomes remains unknown, calling into question if a cutoff is justified. We sought to compare 1-year recurrence rates after transversus abdominis release based on body mass index and to evaluate short- and long-term outcomes. METHODS: Patients undergoing open, clean transversus abdominis release from August 2014 to January 2022 at our institution with 1-year follow-up completed were identified. Univariate and multivariable analyses were performed to determine the association of body mass index with 90-day wound events, 1-year hernia recurrence, and hernia-specific quality of life. Covariates included body mass index, diabetes, recurrent hernia, hernia width, fascial closure, surgical site occurrence requiring procedural intervention, previous abdominal wall surgical site infection, inflammatory bowel disease, mesh weight, and mesh-to-hernia size ratio. RESULTS: A total of 1,089 patients were included. Increasing body mass index was associated with surgical site infection (adjusted odds ratio = 1.59; 95% confidence interval, 1.14-1.77; P < .01) and surgical site occurrence (adjusted odds ratio = 1.42; 95% confidence interval, 1.13-1.74; P < .01) but was not associated with surgical site occurrence requiring procedural intervention. Hernia width was associated with surgical site occurrence (adjusted odds ratio = 1.4; 95% confidence interval, 1.08-1.82; P < .01) and surgical site occurrence requiring procedural intervention (adjusted odds ratio = 1.4; 95% confidence interval, 1.08-1.82; P = .01). Hernia recurrence rate at 1 year was lower for the body mass index ≥35 kg/m2 group (7% vs 12%; P = .02). Hernia width (odds ratio = 1.33; 95% confidence interval, 1.02-1.74; P = .04) was associated with recurrence; body mass index was not (P = .11). Both groups experienced significant improvement in hernia-specific quality of life at 1 year. CONCLUSION: Morbid obesity is associated with 90-day wound morbidity; however, short-term complications did not translate to higher reoperation or long-term recurrence rates. The impact of body mass index on hernia recurrence is likely overstated. An arbitrary body mass index cutoff of 35 kg/m2 should not be used to deny symptomatic patients abdominal wall reconstruction.


Subject(s)
Abdominal Wall , Hernia, Ventral , Obesity, Morbid , Humans , Abdominal Wall/surgery , Hernia, Ventral/surgery , Hernia, Ventral/etiology , Surgical Wound Infection/etiology , Body Mass Index , Quality of Life , Obesity, Morbid/complications , Obesity, Morbid/surgery , Treatment Outcome , Herniorrhaphy/adverse effects , Surgical Mesh/adverse effects , Recurrence , Retrospective Studies
17.
Am J Surg ; 230: 21-25, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37914661

ABSTRACT

INTRODUCTION: Guidelines recommend MIS repairs for females with inguinal hernias, despite limited evidence. We investigated rates of femoral hernias intraoperatively noted during MIS and Lichtenstein repairs in females. METHODS: ACHQC was queried for adult females undergoing inguinal hernia repair between January 2014-November 2022. Outcomes included identified femoral hernia and size, hernia recurrence, quality of life, and sex-based recurrence. RESULTS: 1357 and 316 females underwent MIS and Lichtenstein inguinal repair respectively. Femoral hernias were identified more frequently in MIS than open repairs (27%vs12%; (p â€‹< â€‹0.001). Most femoral hernias in MIS (61%) and Lichtenstein repairs (62%) were <1.5 â€‹cm(p â€‹< â€‹0.001). Identification rates of femoral hernias >3 â€‹cm were 1% overall(p â€‹= â€‹0.09). Surgeon and patient-reported recurrences were similar between approaches at 1-5-years for females(p â€‹> â€‹0.05 for all) and similar between sexes(p â€‹> â€‹0.05). CONCLUSION: Most incidental femoral hernias are small and both repair approaches demonstrated similar outcomes. The recommendation for MIS inguinal hernia repairs in females is potentially overstated.


Subject(s)
Hernia, Femoral , Hernia, Inguinal , Laparoscopy , Adult , Female , Humans , Hernia, Inguinal/diagnosis , Hernia, Inguinal/surgery , Hernia, Femoral/diagnosis , Hernia, Femoral/surgery , Quality of Life , Recurrence , Herniorrhaphy , Surgical Mesh
18.
Am J Surg ; 229: 52-56, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37833195

ABSTRACT

INTRODUCTION: Many studies identify active smoking as a significant risk factor for postoperative wound and mesh complications in patients undergoing abdominal wall reconstruction surgery. However, our group conducted an analysis using data from the ACHQC database, which revealed similar rates of surgical site infection (SSI) and surgical site occurrence requiring procedural intervention (SSOPI) between active smokers and non-smokers As a result, the Cl eveland Clinic Center for Abdominal Core Health instituted a policy change where active smokers were no longer subject to surgical delay. Our study aims to evaluate the impact of active smoking on the outcomes of these patients. METHODS: We identified active smoking patients who had undergone open, elective, clean ventral hernia repair (VHR) with transversus abdominis release (TAR) and permanent synthetic mesh at Cleveland Clinic Foundation. Propensity matching was performed to create a 1:3 ratio of "current-smokers" and "never-smokers" and compared wound complications and all 30-day morbidity between the two groups. RESULTS: 106 current-smokers and 304 never-smokers were matched. Demographics were similar between the two groups after matching, with the exception of chronic obstructive pulmonary disease (COPD) (22.1% vs. 13.4%, p â€‹< â€‹.001) and body mass index (BMI) (31.1 vs. 32.6, p â€‹= â€‹.02). Rates of SSI (12.2% vs. 6.9%, p â€‹= â€‹.13), SSO (21.7% vs. 13.2%, p â€‹= â€‹.052), SSOPI (11.3% vs. 6.3%, p â€‹= â€‹.13), and reoperation (1.9% vs. 3.9%, p â€‹= â€‹.53) were not significantly different between active smokers and never-smokers correspondingly. One case (0.3%) of partial mesh excision was observed in the never-smokers group (p â€‹= â€‹1). The current-smokers group exhibited a significantly higher incidence of pneumonia compared to the never-smokers group (5.7% vs. 0.7%, p â€‹= â€‹.005). CONCLUSION: Our study revealed that operating on active smokers did result in a slight increase in wound morbidity, although it did not reach statistical significance. Additionally, pulmonary complications were higher in the smoking group. Notably, we did not see any mesh infections in the smoking group during early follow up. We believe that this data is important for shared decision making on patients that are actively smoking contemplating elective hernia repair.


Subject(s)
Abdominal Wall , Hernia, Ventral , Smoking Cessation , Humans , Abdominal Wall/surgery , Lifting , Surgical Wound Infection/epidemiology , Surgical Wound Infection/prevention & control , Surgical Wound Infection/etiology , Hernia, Ventral/complications , Herniorrhaphy/adverse effects , Surgical Mesh/adverse effects , Retrospective Studies , Treatment Outcome
19.
Surgery ; 176(1): 148-153, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38641542

ABSTRACT

BACKGROUND: Abdominal wall reconstruction requires extensive dissection of the abdominal wall, exposure of the retroperitoneum, and aggressive chemoprophylaxis to reduce the risk of thromboembolic complications. The need for early anticoagulation puts patients at risk for bleeding. We aimed to quantify postoperative blood loss, incidence of transfusion and reoperation, and associated risk factors in patients undergoing complex abdominal wall reconstruction. METHODS: All patients underwent a posterior component separation with transversus abdominis release and placement of retromuscular mesh for ventral hernias <20 cm wide and were enrolled in a clinical trial assessing the utility of trans-fascial mesh fixation. A post hoc analysis was performed to quantify postoperative hemoglobin drop, blood transfusions, and procedural interventions for ongoing bleeding during the first 30 postoperative days. Multivariate logistic regression was used to identify predictors of transfusion. RESULTS: In 325 patients, hemoglobin decreased by 3.61 (±1.58) g/dL postoperatively. Transfusion incidence was 9.5% (n = 31), and 3.1% (n = 10) required a surgical intervention for bleeding. Initiation of therapeutic anticoagulation postoperatively resulted in a higher likelihood of requiring surgical intervention for bleeding (odds ratio 10.4 [95% confidence interval 2.75-43.8], P < .01). Use of perioperative therapeutic anticoagulation was associated with higher rates of transfusion (odds ratio 3.51 [95% confidence interval 1.34-8.53], P < .01). Neither intraoperative blood loss nor operative times were associated with an increased transfusion requirement or need for operative intervention. CONCLUSION: Patients undergoing transversus abdominis release are at a high risk of postoperative bleeding that can require transfusion and reoperation. Patients requiring postoperative therapeutic anticoagulation are at particularly high risk.


Subject(s)
Abdominal Wall , Blood Transfusion , Hernia, Ventral , Postoperative Hemorrhage , Humans , Male , Female , Middle Aged , Postoperative Hemorrhage/etiology , Postoperative Hemorrhage/epidemiology , Postoperative Hemorrhage/prevention & control , Postoperative Hemorrhage/therapy , Blood Transfusion/statistics & numerical data , Abdominal Wall/surgery , Aged , Hernia, Ventral/surgery , Surgical Mesh/adverse effects , Anticoagulants/therapeutic use , Herniorrhaphy/adverse effects , Herniorrhaphy/methods , Reoperation/statistics & numerical data , Risk Factors , Adult , Plastic Surgery Procedures/adverse effects , Plastic Surgery Procedures/methods , Incidence , Logistic Models
20.
JAMA Surg ; 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38865142

ABSTRACT

Importance: Durable parastomal hernia repair remains elusive. There is limited evidence comparing the durability of the open retromuscular Sugarbaker and keyhole mesh configurations. Objective: To determine if the open retromuscular Sugarbaker mesh placement technique would lower parastomal hernia recurrence rates. Design, Setting, and Participants: In this single-center, randomized clinical trial, 150 patients with a permanent stoma and associated parastomal hernia who were candidates for open retromuscular parastomal hernia repair were enrolled and randomized from April 2019 to April 2022 and followed up for 2 years. Interventions: Following intraoperative assessment to determine the feasibility of either technique, enrolled patients were randomized to receive either retromuscular Sugarbaker or keyhole synthetic mesh placement. Main Outcomes and Measures: The primary outcome was parastomal hernia recurrence at 2 years. Secondary outcomes included mesh-related complications, wound complications, reoperations, as well as patient-reported pain, abdominal wall-specific quality of life, stoma-specific quality of life, and decision regret at 1 year and 2 years. Results: A total of 150 patients were randomized, and with 91% follow-up at 2 years, there were 13 (17%) parastomal hernia recurrences in the retromuscular Sugarbaker arm and 18 (24%) in the keyhole arm (adjusted risk difference, -0.029; 95% CI, -0.17 to 0.153, and adjusted risk ratio, 0.87; 95% CI, 0.42 to 1.69). There were no statistically significant differences between the Sugarbaker and keyhole groups regarding reoperations for recurrence (2 vs 7, respectively), nonhernia intra-abdominal pathology (4 vs 10, respectively), stoma necrosis (1 vs 0, respectively), mesh-related complications (4 vs 1, respectively), patient-reported pain, abdominal wall-specific quality of life, stoma-specific quality of life, and decision regret at any time point. Conclusions and Relevance: In the setting of open parastomal hernia repair, a retromuscular Sugarbaker mesh placement technique was not superior to a keyhole configuration 2 years after repair. Further innovation is necessary to improve parastomal hernia repair outcomes. Trial Registration: ClinicalTrials.gov Identifier: NCT03972553.

SELECTION OF CITATIONS
SEARCH DETAIL