Anal Chem ; 95(38): 14392-14401, 2023 09 26.
Article in English | MEDLINE | ID: mdl-37713676

ABSTRACT

Nuclear magnetic resonance (NMR) is a powerful technique with applications ranging from small molecule structure elucidation to metabolomics studies of living organisms. Typically, solution-state NMR requires a homogeneous liquid, and the whole sample is analyzed as a single entity. While adequate for homogeneous samples, such an approach is limited if the composition varies as would be the case in samples that are naturally heterogeneous or layered. In complex samples such as living organisms, magnetic susceptibility distortions lead to broad 1H line shapes, and thus, the additional spectral dispersion afforded by 2D heteronuclear experiments is often required for metabolite discrimination. Here, a novel, slice-selective 2D, 1H-13C heteronuclear single quantum coherence (HSQC) sequence was developed that exclusively employs shaped pulses such that only spins in the desired volume are perturbed. In turn, this permits multiple volumes in the tube to be studied during a single relaxation delay, increasing sensitivity and throughput. The approach is first demonstrated on standards and then used to isolate specific sample/sensor elements from a microcoil array and finally study slices within a living earthworm, allowing metabolite changes to be discerned with feeding. Overall, slice-selective NMR is demonstrated to have significant potential for the study of layered and other inhomogeneous samples of varying complexity. In particular, its ability to select subelements is an important step toward developing microcoil receive-only arrays to study environmental toxicity in tiny eggs, cells, and neonates, whereas localization in larger living species could help better correlate toxin-induced biochemical responses to the physical localities or organs involved.


Subject(s)
Eggs , Oligochaeta , Humans , Infant, Newborn , Animals , Nuclear Magnetic Resonance, Biomolecular , Hazardous Substances , Metabolomics
2.
Anal Chem ; 95(14): 5858-5866, 2023 04 11.
Article in English | MEDLINE | ID: mdl-36996326

ABSTRACT

Toxicity testing is currently undergoing a paradigm shift from examining apical end points such as death, to monitoring sub-lethal toxicity in vivo. In vivo nuclear magnetic resonance (NMR) spectroscopy is a key platform in this endeavor. A proof-of-principle study is presented which directly interfaces NMR with digital microfluidics (DMF). DMF is a "lab on a chip" method allowing for the movement, mixing, splitting, and dispensing of µL-sized droplets. The goal is for DMF to supply oxygenated water to keep the organisms alive while NMR detects metabolomic changes. Here, both vertical and horizontal NMR coil configurations are compared. While a horizontal configuration is ideal for DMF, NMR performance was found to be sub-par and instead, a vertical-optimized single-sided stripline showed most promise. In this configuration, three organisms were monitored in vivo using 1H-13C 2D NMR. Without support from DMF droplet exchange, the organisms quickly showed signs of anoxic stress; however, with droplet exchange, this was completely suppressed. The results demonstrate that DMF can be used to maintain living organisms and holds potential for automated exposures in future. However, due to numerous limitations of vertically orientated DMF, along with space limitations in standard bore NMR spectrometers, we recommend future development be performed using a horizontal (MRI style) magnet which would eliminate practically all the drawbacks identified here.


Subject(s)
Magnetic Resonance Imaging , Microfluidics , Magnetic Resonance Spectroscopy/methods , Metabolomics/methods , Lab-On-A-Chip Devices
3.
Anal Chem ; 95(37): 13932-13940, 2023 09 19.
Article in English | MEDLINE | ID: mdl-37676066

ABSTRACT

In environmental research, it is critical to understand how toxins impact invertebrate eggs and egg banks, which, due to their tiny size, are very challenging to study by conventional nuclear magnetic resonance (NMR) spectroscopy. Microcoil technology has been extensively utilized to enhance the mass-sensitivity of NMR. In a previous study, 5-axis computer numerical control (CNC) micromilling (shown to be a viable alternative to traditional microcoil production methods) was used to create a prototype copper slotted-tube resonator (STR). Despite the excellent limit of detection (LOD) of the resonator, the quality of the line shape was very poor due to the magnetic susceptibility of the copper resonator itself. This is best solved using magnetic susceptibility-matched materials. In this study, approaches are investigated that improve the susceptibility while retaining the versatility of coil milling. One method involves machining STRs from various copper/aluminum alloys, while the other involves machining ones from an aluminum 2011 alloy and electroplating them with copper. In all cases, combining copper and aluminum to produce resonators resulted in improved line shape and SNR compared to pure copper resonators due to their reduced magnetic susceptibility. However, the copper-plated aluminum resonators showed optimal performance from the devices tested. The enhanced LOD of these STRs allowed for the first 1H-13C heteronuclear multiple quantum coherence (HMQC) of a single intact 13C-labeled Daphnia magna egg (∼4 µg total biomass). This is a key step toward future screening programs that aim to elucidate the toxic processes in aquatic eggs.


Subject(s)
Aluminum , Copper , Animals , Alloys , Biomass , Daphnia
4.
Molecules ; 28(13)2023 Jun 29.
Article in English | MEDLINE | ID: mdl-37446742

ABSTRACT

With sensitivity being the Achilles' heel of nuclear magnetic resonance (NMR), the superior mass sensitivity offered by micro-coils can be an excellent choice for tiny, mass limited samples such as eggs and small organisms. Recently, complementary metal oxide semiconductor (CMOS)-based micro-coil transceivers have been reported and demonstrate excellent mass sensitivity. However, the ability of broadband CMOS micro-coils to study heteronuclei has yet to be investigated, and here their potential is explored within the lens of environmental research. Eleven nuclei including 7Li, 19F, 31P and, 205Tl were studied and detection limits in the low to mid picomole range were found for an extended experiment. Further, two environmentally relevant samples (a sprouting broccoli seed and a D. magna egg) were successfully studied using the CMOS micro-coil system. 13C NMR was used to help resolve broad signals in the 1H spectrum of the 13C enriched broccoli seed, and steady state free precession was used to improve the signal-to-noise ratio by a factor of six. 19F NMR was used to track fluorinated contaminants in a single D. magna egg, showing potential for studying egg-pollutant interactions. Overall, CMOS micro-coil NMR demonstrates significant promise in environmental research, especially when the future potential to scale to multiple coil arrays (greatly improving throughput) is considered.


Subject(s)
Environmental Pollutants , Fluorine , Magnetic Resonance Spectroscopy , Oxides , Semiconductors , Magnetic Resonance Spectroscopy/methods , Brassica/chemistry , Seeds/chemistry , Daphnia magna , Animals , Environmental Pollutants/analysis
5.
Magn Reson Chem ; 60(3): 386-397, 2022 03.
Article in English | MEDLINE | ID: mdl-34647646

ABSTRACT

Microcoils provide a cost-effective approach to improve detection limits for mass-limited samples. Single-sided planar microcoils are advantageous in comparison to volume coils, in that the sample can simply be placed on top. However, the considerable drawback is that the RF field that is produced by the coil decreases with distance from the coil surface, which potentially limits more complex multi-pulse NMR pulse sequences. Unfortunately, 1 H NMR alone is not very informative for intact biological samples due to line broadening caused by magnetic susceptibility distortions, and 1 H-13 C 2D NMR correlations are required to provide the additional spectral dispersion for metabolic assignments in vivo or in situ. To our knowledge, double-tuned single-sided microcoils have not been applied for the 2D 1 H-13 C analysis of intact 13 C enriched biological samples. Questions include the following: Can 1 H-13 C 2D NMR be performed on single-sided planar microcoils? If so, do they still hold sensitivity advantages over conventional 5 mm NMR technology for mass limited samples? Here, 2D 1 H-13 C HSQC, HMQC, and HETCOR variants were compared and then applied to 13 C enriched broccoli seeds and Daphnia magna (water fleas). Compared to 5 mm NMR probes, the microcoils showed a sixfold improvement in mass sensitivity (albeit only for a small localized region) and allowed for the identification of metabolites in a single intact D. magna for the first time. Single-sided planar microcoils show practical benefit for 1 H-13 C NMR of intact biological samples, if localized information within ~0.7 mm of the 1 mm I.D. planar microcoil surface is of specific interest.


Subject(s)
Daphnia , Magnetic Resonance Imaging , Animals , Magnetic Resonance Spectroscopy/methods , Nuclear Magnetic Resonance, Biomolecular
6.
Anal Chem ; 92(23): 15454-15462, 2020 12 01.
Article in English | MEDLINE | ID: mdl-33170641

ABSTRACT

The superior mass sensitivity of microcoil technology in nuclear magnetic resonance (NMR) spectroscopy provides potential for the analysis of extremely small-mass-limited samples such as eggs, cells, and tiny organisms. For optimal performance and efficiency, the size of the microcoil should be tailored to the size of the mass-limited sample of interest, which can be costly as mass-limited samples come in many shapes and sizes. Therefore, rapid and economic microcoil production methods are needed. One method with great potential is 5-axis computer numerical control (CNC) micromilling, commonly used in the jewelry industry. Most CNC milling machines are designed to process larger objects and commonly have a precision of >25 µm (making the machining of common spiral microcoils, for example, impossible). Here, a 5-axis MiRA6 CNC milling machine, specifically designed for the jewelry industry, with a 0.3 µm precision was used to produce working planar microcoils, microstrips, and novel microsensor designs, with some tested on the NMR in less than 24 h after the start of the design process. Sample wells could be built into the microsensor and could be machined at the same time as the sensors themselves, in some cases leaving a sheet of Teflon as thin as 10 µm between the sample and the sensor. This provides the freedom to produce a wide array of designs and demonstrates 5-axis CNC micromilling as a versatile tool for the rapid prototyping of NMR microsensors. This approach allowed the experimental optimization of a prototype microstrip for the analysis of two intact adult Daphnia magna organisms. In addition, a 3D volume slotted-tube resonator was produced that allowed for 2D 1H-13C NMR of D. magna neonates and exhibited 1H sensitivity (nLODω600 = 1.49 nmol s1/2) close to that of double strip lines, which themselves offer the best compromise between concentration and mass sensitivity published to date.


Subject(s)
Costs and Cost Analysis , Magnetic Resonance Spectroscopy/economics , Magnetic Resonance Spectroscopy/instrumentation , Microtechnology/instrumentation , Animals , Daphnia/chemistry , Equipment Design , Mechanical Phenomena , Time Factors
8.
J Magn Reson ; 361: 107653, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38471414

ABSTRACT

Nuclear magnetic resonance (NMR) based 13C tracing has broad applications across medical and environmental research. As many biological and environmental samples are heterogeneous, they experience considerable spectral overlap and relatively low signal. Here a 1D 1H-12C/13C is introduced that uses "in-phase/opposite-phase" encoding to simultaneously detect and discriminate both protons attached to 12C and 13C at full 1H sensitivity in every scan. Unlike traditional approaches that focus on the 12C/13C satellite ratios in a 1H spectrum, this approach creates separate sub-spectra for the 12C and 13C bound protons. These spectra can be used for both quantitative and qualitative analysis of complex samples with significant spectral overlap. Due to the presence of the 13C dipole, faster relaxation of the 1H-13C pairs results in slight underestimation compared to the 1H-12C pairs. However, this is easily compensated for, by collecting an additional reference spectrum, from which the absolute percentage of 13C can be calculated by difference. When combined with the result, 12C and 13C percent enrichment in both 1H-12C and 1H-13C fractions are obtained. As the approach uses isotope filtered 1H NMR for detection, it retains nearly the same sensitivity as a standard 1H spectrum. Here, a proof-of-concept is performed using simple mixtures of 12C and 13C glucose, followed by suspended algal cells with varying 12C /13C ratios representing a complex mixture. The results consistently return 12C/13C ratios that deviate less than 1 % on average from the expected. Finally, the sequence was used to monitor and quantify 13C% enrichment in Daphnia magna neonates which were fed a 13C diet over 1 week. The approach helped reveal how the organisms utilized the 12C lipids they are born with vs. the 13C lipids they assimilate from their diet during growth. Given the experiments simplicity, versatility, and sensitivity, we anticipate it should find broad application in a wide range of tracer studies, such as fluxomics, with applications spanning various disciplines.


Subject(s)
Isotopes , Protons , Magnetic Resonance Spectroscopy/methods , Complex Mixtures , Lipids
9.
Sci Signal ; 11(533)2018 06 05.
Article in English | MEDLINE | ID: mdl-29871911

ABSTRACT

The transient receptor potential (TRP) family is a large family of widely expressed ion channels that regulate the intracellular concentration of ions and metals and respond to various chemical and physical stimuli. TRP subfamily M member 7 (TRPM7) is unusual in that it contains both an ion channel and a kinase domain. TRPM7 is a divalent cation channel with preference for Ca2+ and Mg2+ It is required for the survival of DT40 cells, a B cell line; however, deletion of TRPM7 in T cells does not impair their development. We found that expression of TRPM7 was required for B cell development in mice. Mice that lacked TRPM7 in B cells failed to generate peripheral B cells because of a developmental block at the pro-B cell stage. The loss of TRPM7 kinase activity alone did not affect the proportion of peripheral mature B cells or the development of B cells in the bone marrow. However, supplementation with a high concentration of extracellular Mg2+ partially rescued the development of TRPM7-deficient B cells in vitro. Thus, our findings identify a critical role for TRPM7 ion channel activity in B cell development.


Subject(s)
B-Lymphocytes/cytology , B-Lymphocytes/physiology , Lymphopoiesis , Magnesium/metabolism , Myeloid Cells/physiology , TRPM Cation Channels/physiology , Animals , Cells, Cultured , Female , Mice , Mice, Inbred C57BL , Myeloid Cells/cytology