ABSTRACT
Nucleic acid amplification for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA in respiratory samples is the standard method for diagnosis. The majority of this testing is centralized and therefore has turnaround times of several days. Point-of-care (POC) testing with rapid turnaround times would allow more effective triage in settings where patient management and infection control decisions need to be made rapidly. The inclusivity and specificity of the Simple AMplification-Based Assay (SAMBA) II SARS-CoV-2 test were determined by both in silico analyses of the primers and probes and wet testing. The SAMBA II SARS-CoV-2 test was evaluated for performance characteristics. Clinical performance was evaluated in residual combined throat/nose swabs and compared to that of the Public Health England real-time PCR assay targeting the RdRp gene. The SAMBA II SARS-CoV-2 test has an analytical sensitivity of 250 copies/ml for detecting two regions of the genome (open reading frame 1ab [ORF1ab] and nucleocapsid protein [N]). The clinical performance was evaluated in 172 residual combined nose/throat swabs provided by the Clinical Microbiology and Public Health Laboratory, Addenbrooke's Hospital, Cambridge (CMPHL), which showed an estimated positive percent agreement of 98.9% (95% confidence interval [CI], 93.83 to 99.97) and negative percent agreement of 96.4% (95% CI, 89.92 to 99.26) compared to testing by the CMPHL. The data show that the SAMBA II SARS-CoV-2 test performs equivalently to the centralized testing methods, but with a shorter turnaround time of 86 to 101 min. Point-of-care tests such as SAMBA should enable rapid patient management and effective implementation of infection control measures.
Subject(s)
COVID-19 Testing/methods , COVID-19/diagnosis , Coronavirus Nucleocapsid Proteins/genetics , Nucleic Acid Amplification Techniques/methods , Viral Proteins/genetics , Humans , Molecular Diagnostic Techniques/methods , Point-of-Care Testing , Polyproteins/genetics , RNA, Viral/genetics , SARS-CoV-2/genetics , Sensitivity and SpecificityABSTRACT
BACKGROUND: Early and accurate detection of Listeria in foods is vital. Current methods require 24 h enrichment for detection. OBJECTIVE: This study aimed to demonstrate enhanced early detection of Listeria in mixed leafy greens using Sample6 DETECT™ HT/L, a phage-based detection system. METHODS: A method comparison between the reference method (U.S. Food and Drug Administration Bacteriological Analytical Manual Chapter 10) for the detection of Listeria spp. and the Sample6 DETECT HT/L using a new proprietary R2 Medium was performed in mixed leafy greens. RESULTS: Using the R2 Medium enrichment with Sample6 DETECT HT/L, detection of L. innocua was possible at 12 h (with a centrifugation step), and L. monocytogenes was detected by 18 h, with equivalent performance as the 24 h enrichments using the reference method detection. The Sample6 DETECT HT/L gave an equivalent performance for L. innocua at 15 h as the reference method at 24 h. Detection was accomplished by the addition of reagents in the kit, following the package insert, and reading results in a detection chamber using a 96-well plate reader that detects a fluorescent signal. CONCLUSIONS: Results indicate the new R2 Medium and Sample6 DETECT HT/L allowed for earlier detection of Listeria spp. in mixed leafy greens. HIGHLIGHTS: Sample6 DETECT HT/L with the new R2 Medium allowed the early detection of Listeria spp. and may be applied in other food matrices and environmental samples.
Subject(s)
Bacteriophages , Listeria monocytogenes , Listeria , Culture Media , Food MicrobiologyABSTRACT
Background: Dairy products are common sources of Listeria outbreaks, and early detection of the pathogen is critical to prevent outbreaks of illnesses and financial losses for dairy producers. Objective: This study aimed to evaluate Sample6 Detect HT/L for effective detection of Listeria monocytogenes and L. innocua in ice cream. Methods: Performance of the Sample6 DETECT HT/L was compared with U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM) Chapter 10 method for detection of Listeria spp. in ice cream using an unpaired study design. Results: R2-enriched samples tested with Sample6 Detect HT/L performed as well as the reference method at all time points tested from 15 to 24 h. R2 is a proprietary blend for use with the test kit that helps with early detection. All the dPODC values (Sample6 Detect HT/L presumptive and confirmed results) equaled zero, indicating 100% concordance between the methods. Both Sample6 Detect HT/L and FDA BAM results showed low dPODC values, with confidence intervals indicating no significant differences between Sample6 Detect HT/L and reference method results. Conclusions: Sample6 Detect HT/L is suitable to detect Listeria spp. in ice cream, even with a 12 h enrichment. Sample6 Detect HT/L demonstrated equivalent detection of L. monocytogenes and L. innocua from R2-enriched samples as expected with 15 and 18 h enrichment when compared with the 24 h FDA BAM method for L. monocytogenes. Highlights: These results indicate that Sample6 Detect HT/L, primarily developed for environmental samples, can be used to detect Listeria spp. in ice cream with less incubation time, resulting in faster detection.
Subject(s)
Food Contamination/analysis , Ice Cream/microbiology , Listeria monocytogenes/isolation & purification , Bacteriophage Typing/methods , Food Microbiology/methodsABSTRACT
The Microfilm™ Test System is intended for quantitative microbiology and consists of three types of Microfilms for aerobic plate count (Microfilm APC), total coliform and Escherichia coli count (Microfilm TCEc), and yeast and mold count (Microfilm YMC). This study evaluated the performance of the Microfilm Test System against International Organization for Standardization (ISO) methods on 20 food matrixes and 2 environmental surfaces. Ruggedness, robustness, and stability were also determined, while inclusivity and exclusivity studies were performed on Microfilm TCEc and YMC. An independent laboratory evaluated the performance on four food matrixes and one environmental surface. No significant differences and high correlation coefficients were observed between the Microfilm Test System and the corresponding ISO methods (ISO 4833-1:2013 for APC, ISO 4832:2006 for total coliform count, ISO 16649-2: 2001 for E. coli, and ISO 21527 Part 1 and Part 2 for YMC) in spiked food matrixes and environmental samples. These results were corroborated by the independent laboratory. Inclusivity and exclusivity studies for Microfilm TCEc showed expected results for all the E. coli strains tested (blue-violet or violet color), while the related coliforms showed the expected blue-green colonies on the Microfilm. Similarly, all 100 fungal strains tested showed typical growth on Microfilm YMC. Exclusivity testing on Microfilm TCEc and YMC showed no growth of nontarget organisms. Robustness and ruggedness studies showed no significant differences in mean difference counts at varying incubation temperatures and times. Stability studies on three lots of the Microfilm Test System showed that it is stable at 2-25°C for 12 months and at 45°C for 6 weeks.
Subject(s)
Colony Count, Microbial/methods , Escherichia coli/isolation & purification , Food Analysis/methods , Fungi/isolation & purification , Environmental Monitoring/methods , Escherichia coli/growth & development , Escherichia coli Infections/microbiology , Food Microbiology , Fungi/growth & development , Humans , Mycoses/microbiology , Surface Properties , Yeasts/growth & development , Yeasts/isolation & purificationABSTRACT
Background: Listeria contamination is a major concern in the ice cream industry; therefore, early and accurate detection is vital. Current detection methods require about a 24 h enrichment period for detection. Objective: Enhance the early detection of Listeria in ice cream using the highly sensitive isothermal ribosomal RNA-based Roka/Atlas Listeria Detection Assay. Methods: The R2 Medium was developed for Listeria enrichment by Molecular Epidemiology, Inc. (Seattle, WA). Comparative growth curve studies were performed on the new R2 Medium for Listeria and the currently validated media for the Roka Listeria Detection Assay. Subsequently, a method comparison between the Roka Listeria Detection Assay and the U.S. Food and Drug Administration's (FDA) Bacteriological Analytical Manual (BAM) Chapter 10 reference method on ice cream was carried out. Results: The R2 Medium supports the growth of L. monocytogenes better than Buffered Listeria Enrichment Broth, Demi-Fraser broth, and Modified University of Vermont Broth, as indicated by the faster growth rate of the organism. When used as an enrichment medium in a method comparison study of ice cream, the results showed that R2 Medium-enriched samples tested with the Roka Listeria Detection Assay gave an equivalent performance compared with the 24 h FDA-BAM reference method at 10 and 18 h post-enrichment for Listeria. Conclusions: The results from this study indicate that the new R2 Medium and the highly sensitive Roka Listeria Detection Assay allowed for the rapid detection of Listeria species in ice cream in 13 h. Highlights: The Roka Listeria Detection Assay, in conjunction with a new media formulation (R2 Medium), allowed for the early detection of Listeria in ice cream and may be applied in other food matrixes and environmental samples.