Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 89
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Ann Surg ; 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38501239

ABSTRACT

OBJECTIVE: This study aimed to present the early and mid-term outcomes of fenestrated/branched thoracic endovascular aortic repair (f/bTEVAR) for aortic arch pathologies. BACKGROUND: f/bTEVAR represents a less invasive treatment option for aortic arch diseases. Previous published series showed decreased early mortality and morbidity compared to open repair. METHODS: A single-center retrospective analysis of consecutive patients, managed with f/bTEVAR (Cook Medical, Bloomington, IN, USA) between 01.09.11and 30.06.22 was conducted. Primary outcomes were technical success, 30-day mortality and stroke. Data during follow-up and factors affecting early mortality and stroke were analyzed. RESULTS: 209 patients were included (38.3% females; mean age 69.8±3.4years; mean aortic diameter 61±4.7 mm); 14.4% were managed urgently. Fenestrations/scallop configuration was used in 39.7%, branched devices in 55.5% and branch/scallop combination in 4.8%. Landing to zone 0 was performed in 65.5% and in zone 1 in 32.1%. Non-native aortas were used for landing in 39.2%. Technical success was 97.1% and 30-day mortality 9.5%. Strokes were identified in 10%; 5.7% major. Non-native proximal aortic landing zone was an independent protective factor for stroke (P=0.002). Post-operative stroke (P<0.001) and pericardial effusion (P<0.001) were independently related to 30-day mortality. The mean follow-up was 21±8 months. The estimated survival and freedom from reintervention rates were 79.5% (standard error; SE3.1%) and 47.1% (SE 4.3%) at 24months, respectively. CONCLUSIONS: f/bTEVAR presented high technical success and acceptable 30-day mortality. Non-native proximal landing zone was related to lower stroke rate. Half of patients needed a reintervention within the 24-month follow-up.

2.
J Vasc Surg ; 79(5): 1251-1261.e4, 2024 May.
Article in English | MEDLINE | ID: mdl-37757916

ABSTRACT

OBJECTIVE: Despite open surgical repair (OSR) of abdominal aortic aneurysms being considered as a durable solution, disease progression and para-anastomotic aneurysms may require further repair, and fenestrated and branched endovascular aneurysm repair (F/BEVAR) may be applied to address these pathologies. The aim of this systematic review was to assess technical success, mortality, and morbidity (acute kidney injury, spinal cord ischemia) at 30 days, and mortality and reintervention rates during the available follow-up, in patients managed with F/BEVAR after previous OSR. METHODS: The PRISMA statement was followed, and the study was pre-registered to the PROSPERO (CRD42022363214). The English literature was searched, via Ovid, using MEDLINE, EMBASE, and CENTRAL databases, through November 30, 2022. Observational studies and case series with ≥5 patients (2000-2022), reporting on F/BEVAR outcomes after OSR, were considered eligible. The Newcastle-Ottawa Scale and GRADE were used to assess the risk of bias and quality of evidence. The primary outcome was technical success, mortality, and morbidity at 30 days. Data on the outcomes of interest were synthesized using proportional meta-analysis. RESULTS: The initial search yielded 1694 articles. Eight retrospective studies (476 patients) were considered eligible. In 78.3% of cases, disease progression set the indication for reintervention. Technical success was estimated at 96% (95% confidence interval [CI], 89%-98%; I2 = 0%; 95% prediction interval [PI], 79%-99%). Thirty-day mortality was 2% (95% CI, 1%-9%; I2 = 0%; 95% PI, 0%-28%). The estimated spinal cord ischemia and acute kidney injury rates were 3% (95% CI, 1%-9%; I2 = 0%; 95% PI, 0%-30%) and 6% (95% CI, 2%-15%; I2 = 0%; 95% PI, 1%-40%), respectively. During follow-up, overall mortality was 5% (95% CI, 2%-12%; I2 = 34%; 95% PI, 0%-45%) and aorta-related mortality was 1% (95% CI, 0%-2%; I2 = 0%; 95% PI, 0%-3%). The rate of reinterventions was 16% (95% CI, 9%-26%; I2 = 22%; 95% PI, 3%-50%). CONCLUSIONS: According to the available literature, F/BEVAR after OSR may be performed with high technical success and low mortality and morbidity during the perioperative period. Follow-up aortic-related mortality was 1%, whereas the reintervention rates were within the standard range following F/BEVAR.

3.
J Vasc Surg ; 79(3): 457-468.e2, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38453660

ABSTRACT

BACKGROUND: Fenestrated and branched endovascular aortic repair (F/BEVAR) of thoracoabdominal aortic aneurysms (TAAAs) has shown high technical success and low early mortality rates. Aneurysm extent has been reported as a factor affecting outcomes. This study aimed to assess the early and midterm follow-up outcomes of patients managed by F/BEVAR for types I through III TAAAs. METHODS: A single-center retrospective analysis was conducted, including data from consecutive, elective and urgent (symptomatic and ruptured cases), patients treated for types I through III TAAAs, between October 1, 2011, and October 1, 2022, using F/BEVAR. Degenerative and postdissection TAAAs were included. Patients received prophylactic cerebrospinal fluid drainage (CSFD), except those under therapeutic anticoagulation, those who were hemodynamically unstable, or those with failed CSFD application. When an initial thoracic endovascular aortic repair was performed, as part of a staged procedure, no CSFD was used. Later stages and nonstaged procedures were performed under CSFD. Thirty-day mortality and major adverse events (MAEs) were analyzed. Kaplan-Meier estimates were used for follow-up outcomes. RESULTS: F/BEVAR for types I through III TAAAs was performed in 209 patients (56.9% males; mean age, 69.6 ± 3.2 years; mean aneurysm diameter, 65.2 ± 6.2 mm); 29.2% type I, 57.9% type II, and 12.9% type III. Urgent repair was performed in 26.7% of patients (56 cases; 23 ruptured and 33 symptomatic cases) and 153 were treated electively. Thirty-two patients (15.3%) were classified as American Society of Anesthesiologists (ASA) class IV. CSFD was used in 91% and staged thoracic endovascular aortic repair was performed in 51.2% of patients. Technical success was 93.8% (96.7% in elective vs 94.6% in urgent cases; P = .92). Thirty-day mortality was 11.0% (4.6% in elective vs 28.5% in urgent cases; P < .001) and MAEs were recorded in 17.2% of cases (7.8% in elective vs 42.8% in urgent cases; P < .001). Spinal cord ischemia rate was 20.5% (17.6% in elective vs 28.7% in urgent cases; P = .08), whereas 2.9% of patients presented paraplegia (1.3% in elective and 7.1% in urgent cases; P = .03). The mean follow-up was 16 ± 5 months. Survival was 75.0% (standard error, 4.0%) and freedom from reintervention was 73.3% (standard error, 4.4%) at 36 months. ASA IV and urgent repair were detected as independent factors related to early mortality and MAE, whereas ruptured aneurysm status was related to spinal cord ischemia evolution. CONCLUSIONS: Endovascular repair for types I through III TAAAs provides encouraging early outcomes in terms of mortality, MAE, and paraplegia, especially in an elective setting. Setting of repair and baseline ASA score should be taken into consideration during decision-making.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Spinal Cord Ischemia , Male , Humans , Aged , Female , Endovascular Aneurysm Repair , Blood Vessel Prosthesis , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Retrospective Studies , Risk Factors , Treatment Outcome , Endovascular Procedures/adverse effects , Spinal Cord Ischemia/etiology , Paraplegia/etiology
4.
J Vasc Surg ; 79(6): 1306-1314.e2, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38368998

ABSTRACT

OBJECTIVE: Radiation exposure during complex endovascular aortic repair may be associated with tangible adverse effects in patients and operators. This study aimed to identify the steps of highest radiation exposure during fenestrated endovascular aortic repair (FEVAR) and to investigate potential intraoperative factors affecting radiation exposure. METHODS: Prospective data of 31 consecutive patients managed exclusively with four-fenestration endografts between March 1, 2020, and July 1, 2022 were retrospectively analyzed. Leveraging the conformity of the applied technique, every FEVAR operation was considered a combination of six overall stages composed of 28 standardized steps. Intraoperative parameters, including air kerma, dose area product, fluoroscopy time, and number of digital subtraction angiographies (DSAs) and average angulations were collected and analyzed for each step. RESULTS: The mean procedure duration and fluoroscopy time was 140 minutes (standard deviation [SD], 32 minutes), and 40 minutes (SD, 9.1 minutes), respectively. The mean air kerma was 814 mGy (SD, 498 mGy), and the mean dose area product was 66.8 Gy cm2 (SD, 33 Gy cm2). The percentage of air kerma of the entire procedure was distributed throughout the following procedure stages: preparation (13.9%), main body (9.6%), target vessel cannulation (27.8%), stent deployment (29.1%), distal aortoiliac grafting (14.3%), and completion (5.3%). DSAs represented 23.0% of the total air kerma. Target vessel cannulation and stent deployment presented the highest mean lateral angulation (67 and 63 degrees, respectively). Using linear regression, each minute of continuous fluoroscopy added 18.9 mGy of air kerma (95% confidence interval, 17.6-20.2 mGy), and each DSA series added 21.1 mGy of air kerma (95% confidence interval, 17.9-24.3 mGy). Body mass index and lateral angulation were significantly associated with increased air kerma (P < .001). CONCLUSIONS: Cannulation of target vessels and bridging stent deployment are the steps requiring the highest radiation exposure during FEVAR cases. Optimized operator protection during these steps is mandatory.


Subject(s)
Blood Vessel Prosthesis Implantation , Endovascular Procedures , Radiation Dosage , Radiation Exposure , Humans , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Radiation Exposure/prevention & control , Radiation Exposure/adverse effects , Retrospective Studies , Male , Female , Aged , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Time Factors , Radiography, Interventional/adverse effects , Risk Factors , Blood Vessel Prosthesis , Aged, 80 and over , Stents , Treatment Outcome , Risk Assessment , Operative Time , Aortography , Middle Aged , Angiography, Digital Subtraction , Occupational Exposure/prevention & control , Occupational Exposure/adverse effects , Fluoroscopy , Endovascular Aneurysm Repair
5.
J Vasc Surg ; 2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38580160

ABSTRACT

OBJECTIVE: Fenestrated and branched thoracic endovascular repair (f/bTEVAR) have been successfully applied in patients with diverse aortic arch pathologies. The aim of this study is to present the early and mid-term outcomes of patients with native proximal aortic landing (NPAL) managed with f/bTEVAR. METHODS: A single-center retrospective analysis of patients with NPAL, managed with f/bTEVAR, between September 1, 2011, and June 30, 2022, was conducted. All patients were treated with custom-made devices (Cook Medical) with landing within Ishimaru zones 0 to 2. Primary outcomes were technical success, mortality, stroke, and retrograde type A dissection at 30 days. Follow-up outcomes were considered secondary. RESULTS: A total of 126 patients were included (69.8% males; mean age, 70.8 ± 4.2 years; 18.3% urgent). The main indications (60.4%) for repair were aortic arch (29.4%) and thoracoabdominal aortic aneurysms (31.0%). Seventy-two patients (57.1%) were managed with fTEVAR. Proximal landing in zone 0 and 1 was chosen in 97.6%. Technical success was 94.4%, and 30-day mortality was 11.9%. Strokes were diagnosed in 13.5% of patients and major strokes were identified in 7.9% cases. Retrograde type A dissection rate was 3.9%. The multivariate analysis confirmed landing in Ishimaru zone 0 as an independently related factor for stroke (P = .005), whereas stroke (P < .001), pericardial effusion (P < .001), and acute kidney injury (P < .001) were independently related to 30-day mortality. Mean follow-up was 17.5 ± 9.3 months. The estimated survival rate and the freedom from reintervention rate were 72.6% (standard error, 4.4%) and 46.4% (standard error, 6.0%) at 24-month follow-up, respectively. CONCLUSIONS: Stroke rate after endovascular arch repair was alarming among patients with NPAL. Proximal landing to zone 0 was related to higher risk of stroke. Reinterventions were common within the 24-month follow-up.

6.
J Endovasc Ther ; : 15266028241266158, 2024 Jul 26.
Article in English | MEDLINE | ID: mdl-39058232

ABSTRACT

PURPOSE: To describe the X-over reversed iliac extension technique in a patient with severe peripheral arterial disease (PAD) scheduled for inner branched endovascular aortic repair (iBEVAR). TECHNIQUE: A multimorbid 62-year-old male patient was planned for iBEVAR due to a 58 mm suprarenal aortic aneurysm. The patient had a previous right femoropopliteal bypass and stenting of the left iliac axis. At admission, he presented with recent onset severe left limb claudication, which was attributed to left iliac stent occlusion. To avoid the postoperative compression of the right common femoral artery (CFA) and preserve the patency of the bypass, a single left CFA access, followed by left iliac artery recanalization, was decided. The right iliac axis was catheterized with a Lunderquist wire using X-over access from the left CFA. An iliac extension (ZISL, 24-59, Cook Medical, Bloomington, USA) was reversed and resheathed on back-table and implanted in the right common iliac artery using the X-over technique. The left CFA access was used to complete the remaining steps of the procedure. The predischarge computed tomography angiography confirmed bilateral iliac artery and femoropopliteal bypass patency. CONCLUSION: The X-over reversed iliac extension technique may be applied in selected PAD patients, when undergoing complex endovascular aortic repair. CLINICAL IMPACT: As the number of patients with peripheral arterial disease (PAD) is expected to increase the upcoming decades, out of the box solutions may be needed to assist complex endovascular aortic management. The X over technique, which consist of the contralateral advancement of an on-table reversed iliac limb, was successfully applied in a patient with severe PAD and numerous previous peripheral interventions, who was managed with branched endovascular aortic repair . The X Over technique may provide an additional alternative in well-selected patients with demanding vascular access undergoing complex endovascular aortic procedures.

7.
J Endovasc Ther ; : 15266028241231905, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38380515

ABSTRACT

INTRODUCTION: Data on target vessel (TV)-related outcomes in patients managed with branched thoracic endovascular aortic repair (BTEVAR) are limited. This study aimed to present the TV-related outcomes of BTEVAR in patients managed for aortic arch pathologies at 30 days and during follow-up. METHODS: A retrospective analysis of consecutive patients, managed between September 1, 2011, and June 30, 2022, with custom-made aortic arch endografts (Cook Medical, Bloomington, IN, USA), presenting at least one branch configuration, were eligible. Primary outcomes were technical success, TV-related patency, and reinterventions at 30 days. RESULTS: In total, 255 TVs were revascularized using branches: 107 innominate arteries (IAs), 108 left common carotid arteries (LCCAs), and 40 left subclavian arteries (LSAs). Covered stents were used as bridging stents of which 10.2% were balloon expandable. Relining, using bare-metal stents (BMS), was performed in 14.0% of IAs, 35.2% of LCCAs, and 22.5% of LSAs. Technical success on case basis was 99.2%; no failure was related to unsuccessful TV bridging. At 30 day follow-up, no TV occlusion was detected. In 5.6% of cases, a type Ic or III endoleak, attributed to TVs, was recorded. Two patients needed early branch-related reintervention. The mean follow-up was 18.3±9.2 months. Freedom from TV instability was 94.6% (standard error [SE] 2.5%] at 12 months. No TV stenosis or occlusion was detected up to 48 months of follow-up. Freedom from TV-related reinterventions was 95.4% [SE 2.4%] at 12 months. CONCLUSION: TV stenosis or occlusion in BTEVAR cases is rare and TV-related reinterventions and instability events are mainly attributed to type Ic and III endoleak formation. CLINICAL IMPACT: Previous studies focusing on target vessel (TV) outcomes after endovascular aortic arch repair are limited. In this study, including 255 TVs revascularized using branched arch devices, bridging was performed with covered stents, of which 90% were self-expanding. Relining was at the discretion of the operator and was 14% for the innominate, 35.2% for the left common carotid and 22.5% for the left subclavian artery branches. No 30-day occlusion was detected. The freedom from TV instability was almost 95% at 12 months. TV instability and reintervention were mainly attributed to endoleaks type Ic and IIIc.

8.
J Endovasc Ther ; : 15266028241233163, 2024 Feb 18.
Article in English | MEDLINE | ID: mdl-38369733

ABSTRACT

PURPOSE: Blunt thoracic aortic injury (BTAI) represents a potentially life-threatening condition and thoracic endovascular aortic repair (TEVAR) is recommended as the first-line treatment (Class I level of evidence C) by the current guidelines. The aim of this systematic review was to determine the perioperative and mid-term follow-up outcomes of patients with BTAI treated with TEVAR. MATERIALS AND METHODS: We reviewed the English literature published between 2000 and 2022, via Ovid, using MEDLINE, EMBASE, and CENTRAL databases, until July 30, 2022. Observational studies and case series, with ≥5 patients, reporting on the perioperative and follow-up outcomes of patients who underwent TEVAR for BTAI were included. The Newcastle-Ottawa Scale was used to assess the risk of bias. Primary outcomes were technical success and 30-day mortality, cerebrovascular morbidity. Secondary outcomes were mortality and re-interventions during the mid-term follow-up. RESULTS: From 5201 articles identified by the literature search, 35 eligible studies were included in this review. All studies had a retrospective study design. In total, 991 patients were included. The mean age was 34.5±16.5 years (range=16-89 years). Technical success was 98.0% (odds ratio [OR], 95% confidence interval [CI]=0.98, 0.99, p<0.001, I2=0%). Mortality at 30 days was 5.0% (OR, 95% CI=0.03, 0.06, p<0.001, I2=5.56%). Spinal cord ischemia occurred in 1.0% (OR, 95% CI=0.01, 0.02, p<0.001, I2=0%) and stroke rate was 2.0% (OR, 95% CI=0.01, 0.02, p<0.001, I2=0%). The available follow-up was estimated at 29 months (range=3-119 months) with mortality rate at 2.0% (OR, 95% CI=0.01, 0.02, p<0.001, I2=0%) and re-intervention rate at 1.0% (OR, 95% CI=0.01, 0.02, p<0.001, I2=10.5%). CONCLUSION: Thoracic endovascular aortic repair showed high technical success and low early cerebrovascular morbidity and mortality rates. In the mid-term follow-up, the estimated mortality and re-intervention rates were also low. Furthermore, higher quality prospective studies are needed. CLINICAL IMPACT: Thoracic endovascular aortic repair (TEVAR) is recommended as the first line treatement in patients with blunt thoracic aortic injuries (BTAI). This systematic review of 35 retrospective studies and 991 patients showed high technical success (98.0%) with an associated 30-day mortality at 5.0% and low spinal cord ischemia (1%) and stroke rates (2.0%). Mid-term mortality and re-intervention rates reassure the effectiveness of TEVAR in BTAI cases.

9.
J Endovasc Ther ; : 15266028241267753, 2024 Aug 04.
Article in English | MEDLINE | ID: mdl-39097800

ABSTRACT

INTRODUCTION: Left subclavian artery (LSA) preservation during thoracic endovascular aortic repair (TEVAR) has been related to low morbidity. This study investigated the incidence of LSA stent compression in patients managed with fenestrated endovascular arch repair (f-Arch) and evaluated the impact of anatomic and technical factors on LSA stent outcomes. METHODS: A single-center retrospective analysis of patients managed with single-fenestration devices (Cook Medical, Bloomington, IN, USA) for LSA preservation, between January 1, 2012 and November 30, 2023, was conducted. Anatomic (arch type, bovine arch, distance between the LSA and most proximal bone structure, left common carotid artery and aortic lesion, take-off angle, diameter, thrombus, calcification, dissection, tortuosity) and technical parameters (stent type, diameter, length, relining, post-dilation) were evaluated. Stent compression was any ≥50% stenosis (using center luminal line) of the stent compared with its initial diameter. Clinical outcomes included stroke and upper limb ischemia at 30 days and follow-up. Technical outcomes included stent compression and need for reintervention. RESULTS: Fifty-four cases were included. Only balloon-expandable covered stents were used, and relining during the index procedure was performed in 18%. No stroke or arm ischemia was recorded. One stent compression was detected at 30 days. During follow-up, no stroke or arm ischemia was diagnosed. Nine cases (18%) presented stent compression, with a mean time of stent-compression diagnosis at 18 months (interquartile range [IQR]=37, range=1-58 months) after the index procedure. Five (56%) underwent secondary relining. Follow-up after reintervention was uneventful. Lower distance to the nearest bone structure (compression group [CG]: 11.7±8.9 mm vs non-compression group [NCG]: 23.0±7.8 mm, p=0.003) and higher tortuosity index (CG: 1.3±0.4 vs NCG: 1.2±0.1, p=0.03) were associated with LSA stent compression. CONCLUSION: LSA stent compression in patients managed with f-Arch affected 1 in 5 cases, without clinical consequences. Distance to the nearest bone structure and higher tortuosity were associated with LSA stent compression. CLINICAL IMPACT: Fenestrated endovascular arch repair for the preservation of the left subclavian artery (LSA) in patients needing landing within the aortic arch has been performed with encouraging outcomes. This analysis showed that LSA stent compression is met in 18% of patients, without though any clinical consequence. Pre-operative anatomic parameters, as lower distance to the nearest bone structure and higher tortuosity index affect negatively LSA stent performance while stent parameters seem to have no impact.

10.
J Endovasc Ther ; : 15266028241245341, 2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38597263

ABSTRACT

OBJECTIVES: Electrosurgery has been long used in endovascular procedures, with only case reports in the aortic field. Our aim is to present a case series with the use of an electrified wire to perform catheter-based electrosurgery by applying external current through an electrocautery pen. METHODS: Single-center retrospective case series of all patients undergoing complex aortic surgery from October 2020 to August 2023, in whom the electrified wire technique was used: (1) Perforation of a dissection flap or left subclavian artery (LSA) in situ endograft fenestration-a 0.014" polytetrafluoroethylene (PTFE) insulated guidewire is detached from the insulation with a scalpel at the end and a cautery pen is here attached with a clamp. A curved tip catheter or sheath is positioned against the aortic flap or the endograft (through a left brachial access in this case) and the wire pushed, crossing the flap by activating the electrocautery pen and (2) slicing a dissection flap ("powered cheese-wire technique")-after same preparation as above, the middle section of the 0.014 guidewire is removed from the PTFE and bent into a V-shape. Once in the aorta, the guidewire crosses from the true lumen (TL) to the false lumen (FL) and a through-and-through access is obtained. Sheaths are positioned against the flap from both sides and moved up or down while the electricity is activated, slicing the flap and communicating both lumens. Technical success and technical-related complications were evaluated. RESULTS: Eleven cases concerning aortic dissections and 1 case of aortic atresia were treated. Four patients presented urgently, whereas the rest were planned procedures. Seven cases underwent perforation of a dissection flap, 2 cases underwent the powered cheese-wire technique, in 2 cases for an LSA in situ fenestration, and in 1 case to cross an aortic atresia at the aortic isthmus. The technique was in all cases successfully applied. No complications related to the technique occurred. CONCLUSIONS: The "electrified wire" technique is a feasible and ready-available tool that can be safely used in complex aortic interventions, especially to perforate aortic tissue like dissection flaps or to perform in situ fenestrated repairs by perforation of the endograft fabric. CLINICAL IMPACT: The electrified wire technique described herein is a straightforward technique that uses readily available tools to perform electrosurgery. We present its use in complex aortic procedures. However, it could be envisioned for any vascular procedure that requires crossing of the vessel or even prosthetic material. As we have described in this series, when used along with an adequate properative planning, it can be a safe tool of great utility, as has already been demonstarted in the field of the interventional cardiology.

11.
J Endovasc Ther ; : 15266028241251985, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38708984

ABSTRACT

PURPOSE: The treatment of thoracoabdominal aortic aneurysms (TAAAs) using branched endovascular aortic repair (BEVAR) is safe and effective. During deployment, the superior mesenteric artery (SMA) branch can unintentionally open into the celiac trunk (CT) ostium and switched catheterization of the SMA from the CT branch and the CT from the SMA branch can be used as an alternative technique in these cases. This study aimed to investigate the outcome of exchanging the intended target vessels (TVs) for the CT and SMA branches during BEVAR. MATERIALS AND METHODS: A single-center retrospective analysis of patients with TAAAs who underwent BEVAR, using off-the-shelf or custom-made devices (CMDs), with an unintended exchange of TVs for the CT and SMA branches was performed. RESULTS: Between 2014 and 2023, 397 patients were treated with BEVAR for TAAA. Eighteen (4.5%) of those patients were treated with an exchange of TVs for the CT and SMA branches. T-branch was used in 9 cases (50%) and the remaining patients were treated with CMDs. Twelve patients were treated electively, 3 were symptomatic and 3 presented with rupture. Of 36 mesenteric TVs in those 18 patients, 34 (94%) were catheterized successfully, including all 18 SMAs and 16 of the 18 CTs. No branch stenosis or occlusion of the switched mesenteric TVs was detected during follow-up. During 30-day follow-up, 3 patients died and during a median follow-up of 3 (interquartile range [IQR]: 1-15) months 3 more patients died. None of the deaths or the 2 unintended reinterventions was induced by the mesenteric TV exchange. The median hospital stay was 14 (IQR: 9-22) days with a median of 4 (IQR: 2-11) days at the intensive care unit. CONCLUSION: The exchange of the mesenteric TVs for the CT and SMA branches during BEVAR with off-the-shelf and CMD endografts is feasible with good TV patency and freedom from TV-related reinterventions. This alternative technique should be considered in selected cases when direct catheterization via the intended branch is deemed more time-consuming or not feasible. CLINICAL IMPACT: This is the first description of using an exchange of target vessels for the celiac trunk and the superior mesenteric artery branches in patients with thoracoabdominal aortic aneurysms undergoing BEVAR, using off-the-shelf or custom-made devices. The high success rate as well as the good clinical results without any branch stenosis or occlusion during follow-up highlight the feasibility of this alternative technique. It could help in challenging cases when catheterization of the intended target vessels is not possible or too time consuming, resulting in higher success rates of BEVAR and better clinical results.

12.
J Endovasc Ther ; : 15266028241234497, 2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38409773

ABSTRACT

INTRODUCTION: The aim of this study is to present single-center outcomes in patients treated with in situ laser fenestration thoracic endovascular aortic repair (LFTEVAR) for various aortic arch pathologies and assess the impact of increasing experience. METHODS: The STrengthening the Reporting of OBservational studies in Epidemiology (STROBE) statement was followed. A retrospective analysis of prospectively collected single aortic center data was conducted, including baseline information and peri- and post-operative outcomes of consecutive patients managed with LFTEVAR for aortic arch pathologies. Patients were enrolled from April 1, 2017 to January 31, 2023. The cohort was dichotomized to compare early (2017-2019) and late experience (2020-2023). Primary outcomes were peri-operative mortality and cerebrovascular morbidity. RESULTS: Thirty patients were included (63.3% males, mean age 69.8±9.6 years); 21.4% presented with aortic ruptures. Aortic aneurysm involving the aortic arch was the most frequent pathology (53.3%). Forty target vessels (TVs) were revascularized, including 19 left subclavian arteries (47.5%) and 17 left common carotid arteries (42.5%). Double fenestrations were performed in 10 patients. The proximal landing zone was Ishimaru zone 0 in 5 patients (16.7%) and zone 1 in 13 patients (43.3%). Technical success was 93%. No spinal cord ischemia was recorded, and 3 patients (10%) suffered a post-operative stroke, of which 1 was major (3.3%). The median follow-up was 12 months (range=1-48 months). Thirty-day and follow-up mortality rates were 13.5% and 15.3%, respectively. Target vessel instability was 10%, of which 3.8% required reintervention. There was no statistically significant difference in outcomes between the early and late experience groups. CONCLUSIONS: Laser fenestration thoracic endovascular aortic repair of the aortic arch performed in experienced aortic centers is associated with low early mortality and stroke rates. It is a safe and effective therapeutic option in patients considered unfit for open repair. CLINICAL IMPACT: Custom-made devices for arch pathologies requiring urgent repair are not an option because of manufacturing delays. Off-the-shelf devices with single branch arch prostheses, and outside IFU techniques such as parallel-grafts and surgeon-modified endografts have been proposed in this setting. Another off-the-shelf alternative is in situ laser fenestration thoracic endovascular repair (LFTEVAR), which addresses many limitations of the other off-the-shelf options. Our study reports the outcomes of 30 patients treated with LFTEVAR, showing that it is a viable therapeutic option in patients considered unfit for open repair acknowledging that sufficient experience with complex endovascular aortic repair is mandatory to achieve acceptable outcomes in these high-risk patients with challenging aortic anatomies.

13.
Article in English | MEDLINE | ID: mdl-38697255

ABSTRACT

OBJECTIVE: Fenestrated or branched endovascular aortic repair (F/B-EVAR) is a valuable treatment in patients with chronic post-dissection thoraco-abdominal aneurysm (PD-TAAA). This study aimed to analyse early and follow up outcomes of F/B-EVAR in these patients. METHODS: Thirty day and follow up outcomes of consecutive patients with PD-TAAA treated with F/B-EVAR in a tertiary centre over eight years were analysed retrospectively. All patients presenting with PD-TAAA and managed with F/B-EVAR were eligible. A modified Crawford's classification system was used. Thirty day mortality and major adverse event (MAE) rates were analysed. Time to event data were estimated with Kaplan-Meier survival analysis. RESULTS: Fifty five patients (80% men, mean age 63.7 ± 7.7 years) were included: 12 (22%) were managed urgently; 25 (46%) for chronic type B aortic dissection; and the remainder for residual type A aortic dissection. Of these patients, 88% had undergone previous thoracic endovascular aortic repair. Prophylactic cerebrospinal fluid drainage (CSFD) was used in 91%. Fifteen (27%) patients were treated with F-EVAR, nine (16%) with fenestrations and branches, and 31 (56%) with B-EVAR. False lumen adjunctive procedures were used in 56%. Technical success was achieved in 96% of patients. The thirty day mortality rate was 7% and MAE rate was 20%. Spinal cord injury (SCI) grades 1 - 3 and grade 3 rates were 13% and 2%, respectively. Mean follow up was 33.0 ± 18.4 months. Survival and freedom from unscheduled re-intervention were 86% (standard error [SE] 5%) and 55% (SE 8%) at 24 months, respectively. Freedom from target vessel stenosis and occlusion was higher in F-EVAR at the 12 month follow up (p = .006) compared with B-EVAR. CONCLUSION: Fenestrated or branched endovascular repairs in patients with PD-TAAA showed high technical success, with acceptable early mortality and MAE rates. The SCI rate was > 10%, despite CSFD use and staged procedures. Almost a half of patients needed an unscheduled re-intervention within 24 months after F/B-EVAR.

14.
Eur J Vasc Endovasc Surg ; 67(6): 895-902, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38320646

ABSTRACT

OBJECTIVE: Iliac branch devices (IBDs) have shown good results but there is little evidence for the risk of internal iliac artery (IIA) endoleak, so there are no clear recommendations on the maximum diameter it should be. Based on limited evidence, it was hypothesised that an IIA of ≥ 11 mm in diameter presents an increased risk of type Ic endoleak. METHODS: This was a single centre, retrospective case control study. Patients undergoing an IBD with the main trunk of the IIA as the target vessel, between 2015 and 2021, were identified. Two groups were created: those with a main trunk diameter of < 11 mm; and those with a diameter of ≥ 11 mm. Technical success, freedom from type Ic endoleak, and re-intervention rates were compared. A receiver operating characteristic (ROC) curve was performed to show a cutoff IIA diameter value for risk of type Ic endoleak. Multivariate analysis was performed to assess the risk of type Ic endoleak and the presence of calcification, stenosis, and landing zone length in the IIA. RESULTS: There were 182 IBDs identified. The dilated IIA group (54 IBDs) had significantly lower technical success (91% vs. 98.4%; p = .002), lower freedom from type Ic endoleak (77% vs. 97.1% at 24 months; p = .001), and lower freedom from re-interventions (70% vs. 92.4% at 24 months; p = .002). The ROC curve showed that 10.5 mm was the cutoff diameter for type Ic endoleak. Moderate or severe calcification as well as landing zone length < 5 mm also correlated with type Ic endoleak. CONCLUSION: IBDs have a statistically significantly higher rate of technical failure, lower freedom from type Ic endoleak, and lower freedom from re-intervention when the IIA is ≥ 11 mm in diameter.


Subject(s)
Blood Vessel Prosthesis Implantation , Endoleak , Endovascular Procedures , Iliac Artery , Humans , Endoleak/etiology , Retrospective Studies , Male , Female , Aged , Iliac Artery/surgery , Iliac Artery/diagnostic imaging , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Risk Factors , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Aged, 80 and over , Blood Vessel Prosthesis , Risk Assessment , Treatment Outcome , Case-Control Studies , Dilatation, Pathologic , Prosthesis Design , Middle Aged , Stents/adverse effects
15.
Article in English | MEDLINE | ID: mdl-38677467

ABSTRACT

OBJECTIVE: Female sex is a risk factor for adverse events after endovascular aortic repair. Sex comparative early and midterm outcomes of fenestrated and branched endovascular aortic arch repair (F/B-Arch) are presented. METHODS: A single centre retrospective sex comparative analysis of consecutive patients managed with F/B-Arch was conducted according to STROBE. Primary outcomes were sex comparative technical success, death, and cerebrovascular morbidity at 30 days. Kaplan-Meier estimates were used for follow up outcomes. RESULTS: Among 209 patients, 38.3% were women. Coronary artery disease (p < .001) and previous myocardial infarction (p = .001) were more common in women. Non-native proximal aortic landing was higher in women (women: 51.3%; men: 31.8%, p = .005) and the aortic dissection rate was lower (28.8% vs. 48.1%, p = .005). Proximal landing to Ishimaru zones showed no difference (zone 0: p = .18; zone 1: p = .47; zone 2: p = .39). Graft configurations were equally distributed. In total, 416 supra-aortic trunks were bridged. The median number of revascularisations per patient was two (interquartile range 1, 3), with no difference between sexes (p = .54). Technical success (women: 97.5%; men: 96.9%, p = .80), 30 day mortality rate (women: 10%; men: 9.3%, p = .86), and cerebrovascular morbidity (women: 11.3%; men: 17.1%, p = .25) were similar. Women presented more access related complications (women: 32.5%; men: 16.3%, p = .006), without affecting access related re-interventions (p = .55). Survival (women: 81.1%, 95% confidence interval [CI] 76.3 - 85.9%; men: 79.8%, 95% CI 76.0 - 83.6%) and freedom from re-intervention (women: 56.6%, 95% CI 50.4 - 62.8%; men: 55.3%, 95% CI 50.1 - 60.5%) at 12 months were similar (log rank, p = .40 and p = .41, respectively). CONCLUSION: Both sexes presented similar outcomes after F/B-Arch. Appropriate patient selection may decrease the effect of sex in F/B-Arch outcomes.

16.
Ann Vasc Surg ; 104: 237-247, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38492732

ABSTRACT

BACKGROUND: Fenestrated (FEVAR) and chimney (ChEVAR) endovascular aortic repair have been applied in anatomically suitable complex aortic aneurysms. However, local hemodynamic changes may occur after repair. This study aimed to compare FEVAR's and ChEVAR's hemodynamic properties, focusing on visceral arteries. METHODS: Preoperative and postoperative computed tomography angiographies have been used to reconstruct patient-based models. Data of 3 patients, for each modality, were analyzed. Following geometric reconstruction, computational fluid dynamics simulations were used to extract near-wall and intravascular hemodynamic indicators, such as pressure drops, velocity, wall shear stress, time averaged wall shear stress, oscillatory shear index, relative residence time, and local normalized helicity. RESULTS: An overall improvement in hemodynamics was detected after repair, with either technique. Preoperatively, a disturbed prothrombotic wall shear stress profile was recorded in several zones of the sac. The local normalized helicity results showed a better organization of the helical structures at postoperative setting, decreasing thrombus formation, with both modalities. Similarly, time averaged wall shear stress increased and oscillatory shear index decreased postoperatively, signaling nondisturbed blood flow. The relative residence time was locally reduced. The flow in visceral arteries tended to be more streamlined in ChEVAR, compared to evident recirculation regions at renal and superior mesenteric artery fenestrations (P = 0.06). CONCLUSIONS: ChEVAR and FEVAR seem to improve hemodynamics toward normal values with a reduction of recirculation zones in the main graft and aortic branches. Visceral artery flow comparison revealed that ChEVAR tended to present lower recirculation regions at parallel grafts' entries while FEVAR showed less intense flow regurgitation in visceral stents.


Subject(s)
Blood Vessel Prosthesis Implantation , Blood Vessel Prosthesis , Computed Tomography Angiography , Endovascular Procedures , Hemodynamics , Models, Cardiovascular , Patient-Specific Modeling , Prosthesis Design , Stress, Mechanical , Humans , Endovascular Procedures/instrumentation , Endovascular Procedures/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Treatment Outcome , Blood Flow Velocity , Time Factors , Aortography , Regional Blood Flow , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/physiopathology , Aortic Aneurysm, Abdominal/diagnostic imaging , Aged , Male , Stents , Hydrodynamics , Endovascular Aneurysm Repair
17.
J Vasc Surg ; 77(6): 1806-1814.e2, 2023 06.
Article in English | MEDLINE | ID: mdl-36375726

ABSTRACT

BACKGROUND: A proximal seal extension, after previously failed standard endovascular abdominal aortic aneurysm repair (EVAR), has been described using various endovascular techniques. The aim of the present systematic review was to assess the technical success, 30-day mortality, and mortality and reintervention rates during the available follow-up for patients managed with endovascular methods after failed endovascular repair. METHODS: The present systematic review followed the PRISMA (preferred reporting items for systematic reviews and meta-analyses) statement and was preregistered at PROSPERO (no. CRD42022350436). A search of the English literature, via Ovid, using the MEDLINE, EMBASE, and CENTRAL databases, until June 15, 2022, was performed. Observational studies (2000-2022) and case series with at least five patients who had undergone fenestrated/branched EVAR (F/BEVAR) after failed EVAR were considered eligible. Technical success and mortality at 30 days and the mortality and reintervention rates during available follow-up had to have been reported. The Newcastle-Ottawa scale was used to assess the risk of bias. The primary outcome was technical success and mortality at 30 days. RESULTS: The initial search yielded 2558 reports. Ten studies were considered eligible, two of which were prospective. A total of 423 patients had undergone F/BEVAR after failed EVAR. The indication for reintervention was the presence of a type Ia endoleak in 44.9%. Technical success was reported in seven studies, and 319 of 336 interventions were considered successful (94.9%), according to each study's criteria. Of the 423 patients, 10 had died within 30 days (2.4%). Seven patients had presented with spinal cord ischemia (2.4%). Twenty-three acute kidney injury events were reported (6.8%). The mean follow-up was 18 months (range, 1-77 months). During follow-up, 47 deaths were reported (14.8%). Finally, 50 reinterventions of 303 procedures (16.5%) had been performed. CONCLUSIONS: According to the available literature, F/BEVAR after failed EVAR can be performed with high technical success and low mortality during the perioperative period. The midterm mortality and reintervention rates were acceptable. However, further data are needed to provide firm conclusions regarding the safety and durability of F/BEVAR after failed EVAR.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Blood Vessel Prosthesis , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Prospective Studies , Retrospective Studies , Treatment Outcome , Risk Factors , Prosthesis Design
18.
J Vasc Surg ; 78(4): 883-891.e1, 2023 10.
Article in English | MEDLINE | ID: mdl-37315908

ABSTRACT

OBJECTIVE: Spinal cord ischemia (SCI) is a devastating complication after thoracoabdominal aortic aneurysm (TAAA) repair. The benefit of prophylactic cerebrospinal fluid drainage (pCSFD) to prevent SCI is still under investigation. The aim of this study was to evaluate the SCI rate and the impact of pCSFD following complex endovascular repair (fenestrated or branched endovascular repair [F/BEVAR]) for type I to IV TAAA. METHODS: The STrengthening the Reporting of OBservational studies in Epidemiology (STROBE) statement was followed. A single-center retrospective study was conducted, including all consecutive patients, managed for TAAA type I to IV using F/BEVAR, between January 1, 2018, and November 1, 2022, for degenerative and post-dissection aneurysms. Patients with juxta- or pararenal aneurysms were excluded, as well as cases managed urgently for aortic rupture or acute dissection. After 2020, pCSFD in type I to III TAAAs was abandoned and replaced by therapeutic CSFD (tCSFD), performed only in patients presenting SCI. The primary outcome was the perioperative SCI rate for the entire cohort and the role of pCSFD for type I to III TAAAs. RESULTS: In total, 198 patients were included (mean age, 71.1±3.4 years; 81.8% males), including 50.5% with type I to III TAAA. The primary technical success was 94.9%. The perioperative mortality was 2.5%. and the major adverse cardiovascular event (MACE) rate was 10.6%; 4.5% presented SCI of any type (2.5% paraplegia). When comparing the SCI group with the remaining cohort, patients with SCI presented higher MACE (66.7% vs 7.9%; P < .001) rate and longer intensive care unit stay (3.5 vs 1 day; P = .002). Following type I to III repair, similar SCI, paraplegia, and paraplegia with no recovery rates were reported in the pCSFD and tCSFD groups (7.3% vs 5.1%; P = .66; 4.8% vs 3.3%; P = .72; and 2% vs 0%; P = .37). CONCLUSIONS: The incidence of SCI after TAAA I to IV endovascular repair was low. SCI was associated with significantly increased MACE and intensive care unit stay. The prophylactic use of CSFD in type I to III TAAAs was not associated with lower SCI rates and may not be justified routinely.


Subject(s)
Aneurysm , Aortic Aneurysm, Thoracic , Aortic Aneurysm, Thoracoabdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Spinal Cord Ischemia , Male , Humans , Aged , Female , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Retrospective Studies , Risk Factors , Endovascular Procedures/adverse effects , Spinal Cord Ischemia/diagnosis , Spinal Cord Ischemia/etiology , Spinal Cord Ischemia/prevention & control , Aneurysm/surgery , Drainage/adverse effects , Paraplegia/diagnosis , Paraplegia/etiology , Paraplegia/prevention & control , Treatment Outcome
19.
Rev Cardiovasc Med ; 24(2): 34, 2023 Feb.
Article in English | MEDLINE | ID: mdl-39077414

ABSTRACT

Background: Extended downstream endovascular management has been applied in acute complicated type B aortic dissection (acTBAD), distally to standard thoracic endovascular aortic repair (TEVAR), using bare metal stents, with or without lamina disruption, using balloon inflation. The aim of this systematic review was to assess technical success, 30-day mortality, and mortality during follow-up in patients with acTBAD managed with the Provisional Extension To Induce Complete Attachment (PETTICOAT) or stent-assisted balloon-induced intimal disruption and relamination (STABILISE) technique. Methods: The Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) 2020 statement was followed. A search of the English literature, via Ovid, using MEDLINE, EMBASE, and CENTRAL databases, until 30th August 2022, was executed. Randomized controlled trials and observational studies (published between 2000-2022), with ≥ 5 patients, reporting on technical success, 30-day mortality and mortality during the available follow-up among patients that underwent PETTICOAT or STABILISE technique for acTBAD were eligible. The Newcastle-Ottawa Scale was applied to assess the risk of bias. Primary outcomes were technical success and 30-day mortality, and secondary outcome was mortality during the available follow-up. Results: Thirteen studies were considered eligible, twelve in the quantitative analysis. In total, 418 patients with acTBAD managed with the PETTICOAT (83%) or STABILISE (17%) technique were included. Technical success ranged between 97-100%, 99% for the PETTICOAT and 100% for the STABILISE sub-cohort. Thirty-day mortality was estimated at 3.7% (12/321), 1.4% for the STABILISE and 4.4% for the PETTICOAT technique. All studies reported the mean available follow-up which was estimated at 20 months (range 3-168 months), 22 months (mean value) for the PETTICOAT and 17 months (mean value) for the STABILISE technique. Twenty-three patients died during follow-up, with an estimated mortality rate at 5.7% for the total cohort. The mortality during follow-up was 0% for the STABILISE and 7.0% for the PETTICOAT approach. Conclusions: Both, the PETTICOAT and STABILISE techniques presented less than 4% perioperative mortality in patients with acTBAD with high technical success rate. The mid-term mortality rate was at 6%. However, the heterogeneity in the available studies' highlights the need for further prospective studies, including larger volume and longer follow-up.

20.
J Endovasc Ther ; : 15266028221144589, 2023 Jan 09.
Article in English | MEDLINE | ID: mdl-36624612

ABSTRACT

PURPOSE: The aim is to present a case of in situ fenestrated thoracic endovascular repair, using a re-entry peripheral catheter, needing urgent repair due to recurrent episodes of hemoptysis because of an aorto-bronchial fistula after previous thoracic endovascular aortic repair (TEVAR). TECHNIQUE: A 74-year-old male with a previous TEVAR presented with hemoptysis, fever, and cachexia. An aorto-bronchial fistula and type Ia endoleak were depicted on computed tomography angiography (CTA). Due to the patient's frail general condition, a proximal TEVAR extension was planned, prior to thoracotomy for debridement, and long-term antibiotics. An in situ fenestrated TEVAR was performed to provide proximal sealing and revascularize the left common carotid and subclavian arteries. For fenestration creation, an Upstream Peripheral Go Back catheter (Bentley, Hechingen, Germany) was used. The Go Back catheter has been approved as a re-entry tool for complex peripheral arterial revascularization. In this case, both fenestrations were successfully created. Proximal seal and target vessel patency were confirmed on CTA. Thoracotomy confirmed aortic exclusion. A wedge lobectomy was performed in combination with pediculated omentectomy to exclude the exposed endograft. CONCLUSION: In urgent cases, where custom-made thoracic devices are unavailable, in situ fenestrations with the Go Back catheter are an alternative to laser fenestrations. CLINICAL IMPACT: Fenestrations are often required in acute TEVAR to achieve a proximal seal in the arch. In situ fenestrations with the Go Back catheter are an alternative to laser fenestrations and PMEGs in this setting.

SELECTION OF CITATIONS
SEARCH DETAIL