N Engl J Med ; 389(18): 1660-1671, 2023 Nov 02.
Article in English | MEDLINE | ID: mdl-37634148

ABSTRACT

BACKGROUND: Catheter-based pulmonary vein isolation is an effective treatment for paroxysmal atrial fibrillation. Pulsed field ablation, which delivers microsecond high-voltage electrical fields, may limit damage to tissues outside the myocardium. The efficacy and safety of pulsed field ablation as compared with conventional thermal ablation are not known. METHODS: In this randomized, single-blind, noninferiority trial, we assigned patients with drug-refractory paroxysmal atrial fibrillation in a 1:1 ratio to undergo pulsed field ablation or conventional radiofrequency or cryoballoon ablation. The primary efficacy end point was freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation. The primary safety end point included acute and chronic device- and procedure-related serious adverse events. RESULTS: A total of 305 patients were assigned to undergo pulsed field ablation, and 302 were assigned to undergo thermal ablation. At 1 year, the primary efficacy end point was met (i.e., no events occurred) in 204 patients (estimated probability, 73.3%) who underwent pulsed field ablation and 194 patients (estimated probability, 71.3%) who underwent thermal ablation (between-group difference, 2.0 percentage points; 95% Bayesian credible interval, -5.2 to 9.2; posterior probability of noninferiority, >0.999). Primary safety end-point events occurred in 6 patients (estimated incidence, 2.1%) who underwent pulsed field ablation and 4 patients (estimated incidence, 1.5%) who underwent thermal ablation (between-group difference, 0.6 percentage points; 95% Bayesian credible interval, -1.5 to 2.8; posterior probability of noninferiority, >0.999). CONCLUSIONS: Among patients with paroxysmal atrial fibrillation receiving a catheter-based therapy, pulsed field ablation was noninferior to conventional thermal ablation with respect to freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation and with respect to device- and procedure-related serious adverse events at 1 year. (Funded by Farapulse-Boston Scientific; ADVENT ClinicalTrials.gov number, NCT04612244.).


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/classification , Atrial Fibrillation/surgery , Bayes Theorem , Catheter Ablation/adverse effects , Catheter Ablation/methods , Pulmonary Veins/surgery , Recurrence , Single-Blind Method , Tachycardia/etiology , Treatment Outcome
2.
Circulation ; 2024 Sep 11.
Article in English | MEDLINE | ID: mdl-39258362

ABSTRACT

BACKGROUND: Evidence from clinical trials of early pulsed field ablation (PFA) systems in treating atrial fibrillation has demonstrated their promising potential to reduce complications associated with conventional thermal modalities while maintaining efficacy. However, the lack of a fully integrated mapping system, a staple technology of most modern electrophysiology procedures, poses limitations in lesion creation and workflow options. A novel variable-loop PFA catheter integrated with an electroanatomic mapping system has been developed that allows for real-time nonfluoroscopic procedural guidance and lesion indexing as well as feedback of tissue-to-catheter proximity. ADMIRE (Assessment of Safety and Effectiveness in Treatment Management of Atrial Fibrillation With the Bosense-Webster Irreversible Electroporation Ablation System), a multicenter, single-arm, Food and Drug Administration investigational device exemption study, evaluated the long-term safety and effectiveness of this integrated PFA system in a large United States-based drug-refractory symptomatic paroxysmal atrial fibrillation patient population. METHODS: Using the PFA catheter with a compatible electroanatomic mapping system, patients with drug-refractory symptomatic paroxysmal atrial fibrillation underwent pulmonary vein isolation. The primary safety end point was primary adverse event within 7 days of ablation. The primary effectiveness end point was a composite end point that included 12-month freedom from documented atrial tachyarrhythmia (ie, atrial fibrillation, atrial tachycardia, atrial flutter) episodes, failure to achieve pulmonary vein isolation, use of a nonstudy catheter for pulmonary vein isolation, repeat procedure (except for one redo during blanking), taking a new or previously failed class I or III antiarrhythmic drug at higher dose after blanking, or direct current cardioversion after blanking. RESULTS: At 30 centers, 277 patients with paroxysmal atrial fibrillation (61.5±10.3 years of age; 64.3% male) in the pivotal cohort underwent PFA. More than 25% of the procedures were performed without fluoroscopy. Median (Q1, Q3) pulmonary vein isolation procedure, fluoroscopy, and transpired PFA application times were 81.0 (61.0, 112.0), 7.1 (0.00, 14.3), and 31.0 (24.8, 40.9) minutes, respectively. The primary adverse event rate was 2.9% (8 of 272), with the most common complication being pericardial tamponade. The 12-month primary effectiveness end point was 74.6%. The 1-year freedom from atrial fibrillation, atrial tachycardia, or atrial flutter recurrence rate after blanking was 75.4%. Substantial improvements in quality of life were observed as early as 3 months after the procedure, concurrent with a reduction in multiple health care use measures. CONCLUSIONS: ADMIRE confirmed the safety and effectiveness of the variable-loop PFA catheter, with short procedure and PFA application times and low fluoroscopy exposure. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT05293639.

3.
Eur Heart J ; 2024 Sep 26.
Article in English | MEDLINE | ID: mdl-39322413

ABSTRACT

Recent advances in techniques, technologies and proven superiority over anti-arrhythmic drugs have made catheter ablation the cornerstone of management for atrial fibrillation (AF), which has shown a steady increase in prevalence in the ageing population worldwide. The aim of therapeutic interventions is to achieve stable sinus rhythm that would improve the quality of life and reduce the risk of AF-associated complications. Pulmonary veins (PVs) were first described as the source of initiation of ectopic triggers driving AF, which led to the establishment of PV isolation (PVI) as the most widely practiced procedure to treat AF. Antral PVI is still recognized as the stand-alone ablation strategy for newly diagnosed paroxysmal AF (PAF). However, in non-PAF patients, PVI seems to be inadequate and several adjunctive strategies, including ablation of left atrial posterior wall and non-PV triggers, AF mapping and ablation of rotors and drivers, ethanol infusion of vein of Marshall and renal denervation, etc. have been reported with mixed results. Recent trials have also documented the benefits of early rhythm control in preventing cardiovascular events in addition to slowing the progression of PAF to more persistent forms. Similarly, very late relapse of the arrhythmia after successful PVI has drawn attention to the critical role of non-PV triggers and highlighted their relevance as potential ablation targets during repeat procedures. Ablation technology is also under constant evolution with the introduction of non-thermal energy sources and new tools to create durable lesions. This review summarizes the indications, advancements, and future perspective of AF ablation.

4.
Circulation ; 147(19): 1422-1432, 2023 05 09.
Article in English | MEDLINE | ID: mdl-36877118

ABSTRACT

BACKGROUND: Pulsed field ablation uses electrical pulses to cause nonthermal irreversible electroporation and induce cardiac cell death. Pulsed field ablation may have effectiveness comparable to traditional catheter ablation while preventing thermally mediated complications. METHODS: The PULSED AF pivotal study (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF) was a prospective, global, multicenter, nonrandomized, paired single-arm study in which patients with paroxysmal (n=150) or persistent (n=150) symptomatic atrial fibrillation (AF) refractory to class I or III antiarrhythmic drugs were treated with pulsed field ablation. All patients were monitored for 1 year using weekly and symptomatic transtelephonic monitoring; 3-, 6-, and 12-month ECGs; and 6- and 12-month 24-hour Holter monitoring. The primary effectiveness end point was freedom from a composite of acute procedural failure, arrhythmia recurrence, or antiarrhythmic escalation through 12 months, excluding a 3-month blanking period to allow recovery from the procedure. The primary safety end point was freedom from a composite of serious procedure- and device-related adverse events. Kaplan-Meier methods were used to evaluate the primary end points. RESULTS: Pulsed field ablation was shown to be effective at 1 year in 66.2% (95% CI, 57.9 to 73.2) of patients with paroxysmal AF and 55.1% (95% CI, 46.7 to 62.7) of patients with persistent AF. The primary safety end point occurred in 1 patient (0.7%; 95% CI, 0.1 to 4.6) in both the paroxysmal and persistent AF cohorts. CONCLUSIONS: PULSED AF demonstrated a low rate of primary safety adverse events (0.7%) and provided effectiveness consistent with established ablation technologies using a novel irreversible electroporation energy to treat patients with AF. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04198701.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Prospective Studies , Treatment Outcome , Anti-Arrhythmia Agents/therapeutic use , Electrocardiography , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
5.
J Cardiovasc Electrophysiol ; 35(8): 1601-1613, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38887842

ABSTRACT

INTRODUCTION: Four-dimensional (4D) intracardiac echocardiography (ICE) is a novel cardiac imaging modality that has been applied to various workflows, including catheter ablation, tricuspid valve repair, and left atrial appendage occlusion (LAAO). The use of this type of advanced ICE imaging may ultimately allow for the replacement of transesophageal echocardiography (TEE) for LAAO, providing comparable imaging quality while eliminating the need for general anesthesia. METHODS: Based on our initial clinical experience with 4D ICE in LAAO, we have developed an optimized workflow for the use of the NUVISION™ 4D ICE Catheter in conjunction with the GE E95 and S70N Ultrasound Systems in LAAO. In this manuscript, we provide a step-by-step guide to using 4D ICE in conjunction with compatible imaging consoles. We have also evaluated the performance of 4D ICE with the NUVISION Ultrasound Catheter versus TEE in one LAAO case and present those results here. RESULTS: In our comparison of 4D ICE using our optimized workflow with TEE in an LAAO case, ICE LAA measurements were similar to those from TEE. The best image resolution was seen via ICE in 2-dimensional and multislice modes (triplane and biplane). The FlexiSlice multiplanar reconstruction tool, which creates an en-face image derived from a 4D volume set, also provided valuable information but yielded slightly lower image quality, as expected for these volume-derived images. For this case, comparable images were obtained with TEE and ICE but with less need to reposition the ICE catheter. CONCLUSION: The use of optimized 4D ICE catheter workflow recommendations allows for efficient LAAO procedures, with higher resolution imaging, comparable to TEE.


Subject(s)
Atrial Appendage , Echocardiography, Four-Dimensional , Echocardiography, Transesophageal , Workflow , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Predictive Value of Tests , Cardiac Catheterization/instrumentation , Ultrasonography, Interventional , Male
6.
Article in English | MEDLINE | ID: mdl-39099135

ABSTRACT

INTRODUCTION: Hemostasis following large-bore femoral vein access remains a challenge. Manual compression has been the standard of care but requires bedside staff, prolonged bed rest, and longer length of stay. The LockeT is an external compression device that attempts to address these issues while achieving venous hemostasis. OBJECTIVES: We evaluate postprocedural hemostasis and vascular closure outcomes after using LockeT following cardiac electrophysiologic procedures. METHODS: We performed a single-center, observational study of patients who underwent vascular closure for electrophysiology procedures using LockeT. Postprocedural outcomes were subsequently analyzed. RESULTS: We studied 102 patients (N) for whom LockeT was used to close 182 separate vascular access sites (n). Common procedures were atrial fibrillation ablation (56.9%, N = 58) and left atrial appendage occlusion (28.4%, N = 29). Most often, 8-Fr [48.3% (n = 126)], 11-Fr [27.2% (n = 71)], and 8.5-Fr [16.9% (n = 44)] sheaths were used, with an average procedure time of 82.1 ± 29.4 min. Hemostasis was achieved in 97.8% (n = 187) of all LockeT cases. Time to ambulation and discharge were 3.93 ± 1.10 h and 8.1 ± 4.4 h, respectively. No major complications were noted. Postprocedurally, 52% (N = 53) of patients were discharged on the same day. There were no differences in hemostasis (p = .859) or ambulation times (p = .202) between procedure types. CONCLUSION: The LockeT can effectively close venous access sites with no major complications.

7.
J Cardiovasc Electrophysiol ; 35(2): 278-287, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38073051

ABSTRACT

INTRODUCTION: Transvenous lead extraction (TLE), while mostly a safe procedure, has risk of serious periprocedural complications. As such, overnight hospitalization remains a routine practice. In our center, we routinely discharge patients on the same day following an uncomplicated TLE. METHODS: This is a retrospective study of 265 consecutive patients who underwent uncomplicated TLE in our center between 2019 and 2021. Same-day discharge (SDD) patients are compared with those who stayed at least overnight for observation after the TLE procedure (non-SDD group). To assess the safety of an SDD strategy after uncomplicated TLE, the main study endpoint was to compare the rate of major procedure-related complications at 1-, 7-, and 30-days. To identify the factors influencing the operator's decision to discharge the patient on the same day, the secondary endpoint was to analyze clinical and procedural predictors of SDD. RESULTS: A total of 153 patients were discharged the same day after uncomplicated TLE (SDD), while 112 stayed at least overnight after the procedure (non-SDD). There was no significant difference in major procedure-related complications at 1-day (SDD 0% vs. non-SDD 1.8%, p value = ns), while patients in the SDD group had a lower rate of 7- and 30-day complications when compared with those in the non-SDD group (2.1% vs. 8.2%, p value = .0308; and 3.5% vs. 16%, p value = .0049, respectively). Noninfectious indication for TLE (OR 16.1, 95% confidence interval [CI] 4.29-77.6) and procedure end time before 12:00 (OR 2.82, 95% CI 1.11-7.27) were the only independent predictors of SDD. CONCLUSION: SDD discharge following uncomplicated TLE in selected patients (i.e., those without device infection and when the TLE procedure is completed in the morning) is feasible and safe.


Subject(s)
Hospitalization , Patient Discharge , Humans , Device Removal , Feasibility Studies , Retrospective Studies , Treatment Outcome
8.
J Cardiovasc Electrophysiol ; 35(7): 1422-1428, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38751010

ABSTRACT

INTRODUCTION: Both atrial fibrillation (AF) and amyloidosis increase stroke risk. We evaluated the best anticoagulation strategy in AF patients with coexistent amyloidosis. METHODS: Consecutive AF patients with concomitant amyloidosis were divided into two groups based on the postablation stroke-prophylaxis approach; group 1: left atrial appendage occlusion (LAAO) in eligible patients and group 2: oral anticoagulation (OAC). Group 1 patients were further divided into Gr. 1A: LAAO + half-does NOAC (HD-NOAC) for 6 months followed by aspirin 81 mg/day and Gr. 1B: LAAO + HD-NOAC. In group 1 patients, with complete occlusion at the 45-day transesophageal echocardiogram, patients were switched to aspirin, 81 mg/day at 6 months. In case of leak, or dense "smoke" in the left atrium (LA) or enlarged LA, they were placed on long-term half-dose (HD) NOAC. Group 2 patients remained on full-dose NOAC during the whole study period. RESULTS: A total of 92 patients were included in the analysis; group 1: 56 and group 2: 36. After the 45-day TEE, 31 patients from group 1 remained on baby-aspirin and 25 on HD NOAC. At 1-year follow-up, four stroke, one TIA and six device-thrombus were reported in group 1A, compared to none in patients in group 1B (5/31 vs. 0/25, p = .03). No bleeding events were reported in group 1, whereas group 2 had five bleeding events (one subdural hematoma, one retinal hemorrhage, and four GI bleedings). Additionally, one stroke was reported in group 2 that happened during brief discontinuation of OAC. CONCLUSION: In patients with coexistent AF and amyloidosis, half-dose NOAC following LAAO was observed to be the safest stroke-prophylaxis strategy.


Subject(s)
Amyloidosis , Anticoagulants , Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Stroke , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/complications , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Male , Female , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Atrial Appendage/surgery , Aged , Middle Aged , Treatment Outcome , Stroke/prevention & control , Stroke/etiology , Stroke/diagnosis , Catheter Ablation/adverse effects , Anticoagulants/administration & dosage , Anticoagulants/adverse effects , Risk Factors , Time Factors , Amyloidosis/complications , Amyloidosis/diagnosis , Amyloidosis/diagnostic imaging , Hemorrhage/chemically induced , Administration, Oral , Retrospective Studies , Risk Assessment , Aspirin/administration & dosage , Aspirin/adverse effects , Drug Administration Schedule , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/complications , Cardiomyopathies/diagnosis
9.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38584468

ABSTRACT

AIMS: Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS: After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION: Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.


Subject(s)
Atrial Fibrillation , Cardiac Catheters , Catheter Ablation , Pulmonary Veins , Recurrence , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Catheter Ablation/methods , Catheter Ablation/instrumentation , Male , Female , Middle Aged , Aged , Treatment Outcome , Equipment Design , Electrophysiologic Techniques, Cardiac , Time Factors , Heart Rate , Action Potentials
10.
Europace ; 26(9)2024 Aug 30.
Article in English | MEDLINE | ID: mdl-39150065

ABSTRACT

AIMS: Pulsed-field ablation (PFA) is a novel, myocardial-selective, non-thermal ablation modality used to target cardiac arrhythmias. Although prompt electrogram (EGM) signal disappearance is observed immediately after PFA application in the pulmonary veins, whether this finding results in adequate transmural lesions is unknown. The aim of this study is to check whether application repetition and catheter-tissue contact impact lesion formation during PFA. METHODS AND RESULTS: A circular loop PFA catheter was used to deliver repeated energy applications with various levels of contact force. A benchtop vegetal potato model and a beating heart ventricular myocardial model were utilized to evaluate the impact of application repetition, contact force, and catheter repositioning on contiguity and lesion depth. Lesion development occurred over 18 h in the vegetal model and over 6 h in the porcine model. Lesion formation was found to be dependent on application repetition and contact. In porcine ventricles, single and multiple stacked applications led to a lesion depth of 3.5 ± 0.7 and 4.4 ± 1.3 mm, respectively (P = 0.002). Furthermore, the greater the catheter-tissue contact, the more contiguous and deeper the lesions in the vegetal model (1.0 ± 0.9 mm with no contact vs. 5.4 ± 1.4 mm with 30 g of force; P = 0.0001). CONCLUSION: Pulsed-field ablation delivered via a circular catheter showed that both repetition and catheter contact led independently to deeper lesion formation. These findings indicate that endpoints for effective PFA are related more to PFA biophysics than to mere EGM attenuation.


Subject(s)
Cardiac Catheters , Catheter Ablation , Equipment Design , Catheter Ablation/methods , Catheter Ablation/instrumentation , Animals , Swine , Heart Ventricles/physiopathology , Heart Ventricles/surgery , Models, Animal , Sus scrofa , Time Factors
11.
Europace ; 26(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38305503

ABSTRACT

AIMS: When it occurs, pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is associated with significant morbidity. Even mild-to-moderate PV narrowing may have long-term implications. Unlike thermal ablation energies, such as radiofrequency (RF) or cryothermy, pulsed field ablation (PFA) is a non-thermal modality associated with less fibrotic proliferation. Herein, we compared the effects of PFA vs. thermal ablation on PV narrowing after AF ablation. METHODS AND RESULTS: ADVENT was a multi-centre, randomized, single-blind study comparing PFA (pentaspline catheter) with thermal ablation-force-sensing RF or cryoballoon (CB)-to treat drug-refractory paroxysmal AF. Pulmonary vein diameter and aggregate cross-sectional area were obtained by baseline and 3-month imaging. The pre-specified, formally tested, secondary safety endpoint compared a measure of PV narrowing between PFA vs. thermal groups, with superiority defined by posterior probability > 0.975. Among subjects randomized to PFA (n = 305) or thermal ablation (n = 302), 259 PFA and 255 thermal ablation (137 RF and 118 CB) subjects had complete baseline and 3-month PV imaging. No subject had significant (≥70%) PV stenosis. Change in aggregate PV cross-sectional area was less with PFA (-0.9%) than thermal ablation (-12%, posterior probability > 0.999)-primarily driven by the RF sub-cohort (-19.5%) vs. CB sub-cohort (-3.3%). Almost half of all PFA PV diameters did not decrease, but the majority (80%) of RF PVs decreased, regardless of PV anatomic location. CONCLUSION: In this first randomized comparison of PFA vs. thermal ablation, PFA resulted in less PV narrowing-thereby underscoring the qualitatively differential and favourable impact of PFA on PV tissue.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Stenosis, Pulmonary Vein , Humans , Pulmonary Veins/surgery , Constriction, Pathologic/complications , Constriction, Pathologic/surgery , Single-Blind Method , Treatment Outcome , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Catheter Ablation/adverse effects , Catheter Ablation/methods , Stenosis, Pulmonary Vein/diagnostic imaging , Stenosis, Pulmonary Vein/etiology
12.
Europace ; 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-39351961

ABSTRACT

BACKGROUND AND AIMS: Rhythm control of non-paroxysmal atrial fibrillation (AF) is significantly more challenging, as a result of arrhythmia perpetuation promoting atrial substrate changes and AF maintenance. We describe a tailored ablation strategy targeting multiple left atrial (LA) sites via a pentaspline pulsed field ablation (PFA) catheter in persistent AF sustained beyond 6 months (PerAF>6m) and long-standing persistent AF (LSPAF). METHODS: The ablation protocol included the following stages: pulmonary vein antral and posterior wall isolation plus anterior roof line ablation (Stage 1); electrogram-guided substrate ablation (Stage 2); atrial tachyarrhythmia regionalization and ablation (Stage 3). RESULTS: Seventy-two [age:68±10years, 61.1%males; AF history: 25 (18-45) months] patients with PerAF>6m (52.8%) and LSPAF (47.2%) underwent their first PFA via the FarapulseTM system. LA substrate ablation (Stage 1 and 2) led to AF termination in 95.8% of patients. AF organized into a left-sided atrial flutter (AFlu) in 46 (74.2%) patients. The PFA catheter was used to identify LA sites showing diastolic, low-voltage electrograms and entrainment from its splines was performed to confirm the pacing site was inside the AFlu circuit. Left AFlu termination was achieved in all cases via PFA delivery. Total procedural and LA dwell times were 112±25min and 59±22 min, respectively. Major complications occurred in 2 (2.8%) patients. Single-procedure success rate was 74.6% after 14.9±2.7 months of follow-up; AF-free survival was 89.2%. CONCLUSIONS: In our cohort, PFA-based AF substrate ablation led to AF termination in 95.8% of cases. Very favorable clinical outcomes were observed during >1year of follow-up.

13.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38587017

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Latin America , Treatment Outcome , Catheters , Asia , Catheter Ablation/adverse effects , Catheter Ablation/methods
14.
Cardiology ; : 1-8, 2024 Jul 22.
Article in English | MEDLINE | ID: mdl-38986462

ABSTRACT

INTRODUCTION: Patients undergoing left atrial appendage occlusion (LAAO) are at increased risk for bleeding or thromboembolic events. Concurrently, biomarkers are of growing importance in risk stratification for atrial fibrillation patients. We aimed to evaluate the association of hematological markers and clinical characteristics with the occurrence of thromboembolic and bleeding events following LAAO. METHODS: Seven implanting centers retrospectively gathered data on hematological markers (i.e., platelet count [PC], mean platelet volume [MPV], and fibrinogen) prior to LAAO. Prespecified thromboembolic and major bleeding outcomes were collected and the association with pre-procedural hematological markers and clinical characteristics was evaluated using Cox regression analysis. RESULTS: In total, 1,315 patients were included (74 ± 9 years, 36% female, CHA2DS2-VASc 4.3 ± 1.5, HAS-BLED 3.3 ± 1.1). Over a total follow-up duration of 2,682 patient years, 77 thromboembolic events and 107 major bleeding events occurred after LAAO. Baseline PC was the only biomarker showing a signal for a relation to thromboembolic events (HR 1.18, 95% CI: 1.00-1.39) per 50*109 increment, p = 0.056). Thrombotic event rates, including device-related thrombus, increased within higher PC quartiles. Thromboembolism was associated with age (HR 1.05, 95% CI: 1.00-1.10, per year increase) and prior thromboembolism (HR 2.08, 95% CI: 1.07-4.03), but with none of the biomarkers in multivariate analysis. No association of any of the hematological markers with major bleeding was observed. Major bleeding following LAAO was associated with prior major bleeding (HR 5.27, 95% CI: 2.71-10.22), renal disease (HR 1.93, 95% CI: 1.17-3.18), and discharge on dual antiplatelet therapy (DAPT) (HR 1.71, 95% CI: 1.05-2.77). CONCLUSION: Most thrombotic events occurred in the highest PC quartile, but no association of any of the hematological markers with thromboembolism or major bleeding was observed in our analysis. In multivariate analysis, older age and prior thromboembolism were associated with thromboembolism. Prior major bleeding, renal disease and discharge on DAPT were multivariate predictors of major bleeding after LAAO.

15.
Medicina (Kaunas) ; 60(1)2024 Jan 03.
Article in English | MEDLINE | ID: mdl-38256355

ABSTRACT

Pediatric cardiomyopathies (CMs) and electrical diseases constitute a heterogeneous spectrum of disorders distinguished by structural and electrical abnormalities in the heart muscle, attributed to a genetic variant. They rank among the main causes of morbidity and mortality in the pediatric population, with an annual incidence of 1.1-1.5 per 100,000 in children under the age of 18. The most common conditions are dilated cardiomyopathy (DCM) and hypertrophic cardiomyopathy (HCM). Despite great enthusiasm for research in this field, studies in this population are still limited, and the management and treatment often follow adult recommendations, which have significantly more data on treatment benefits. Although adult and pediatric cardiac diseases share similar morphological and clinical manifestations, their outcomes significantly differ. This review summarizes the latest evidence on genetics, clinical characteristics, management, and updated outcomes of primary pediatric CMs and electrical diseases, including DCM, HCM, arrhythmogenic right ventricular cardiomyopathy (ARVC), Brugada syndrome (BrS), catecholaminergic polymorphic ventricular tachycardia (CPVT), long QT syndrome (LQTS), and short QT syndrome (SQTS).


Subject(s)
Cardiomyopathy, Dilated , Cardiomyopathy, Hypertrophic , Heart Diseases , Long QT Syndrome , Adult , Child , Humans , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/genetics , Heart , Cardiomyopathy, Dilated/epidemiology , Cardiomyopathy, Dilated/genetics
16.
Am Heart J ; 264: 123-132, 2023 10.
Article in English | MEDLINE | ID: mdl-37279840

ABSTRACT

BACKGROUND: Percutaneous left atrial appendage (LAA) closure (LAAC) was developed as a nonpharmacologic alternative to oral anticoagulants (OACs) in patients with atrial fibrillation (AF) who are at an increased risk for stroke or systemic embolism. The Watchman device permanently seals off the LAA to prevent thrombi from escaping into the circulation. Previous randomized trials have established the safety and efficacy of LAAC compared to warfarin. However, direct OACs (DOACs) have become the preferred pharmacologic strategy for stroke prevention in patients with AF, and there is limited data comparing Watchman FLX to DOACs in a broad AF patient population. CHAMPION-AF is designed to prospectively determine whether LAAC with Watchman FLX is a reasonable first-line alternative to DOACs in patients with AF who are indicated for OAC therapy. STUDY DESIGN: A total of 3,000 patients with a CHA2DS2-VASc score ≥2 (men) or ≥3 (women) were randomized to Watchman FLX or DOAC in a 1:1 allocation at 142 global clinical sites. Patients in the device arm were to be treated with DOAC and aspirin, DOAC alone, or DAPT for at least 3 months postimplant followed by aspirin or P2Y12 inhibitor for 1-year. Control patients were required to take an approved DOAC for the duration of the trial. Clinical follow-up visits are scheduled at 3- and 12-months, and then annually through 5 years; LAA imaging is required at 4 months in the device group. Two primary end points will be evaluated at 3 years: (1) composite of stroke (ischemic/hemorrhagic), cardiovascular death, and systemic embolism compared for noninferiority, and (2) nonprocedural bleeding (International Society on Thrombosis and Haemostasis [ISTH] major and clinically relevant nonmajor bleeding) tested for superiority in the device arm against DOACs. The third primary noninferiority end point is the composite of ischemic stroke and systemic embolism at 5 years. Secondary end points include 3- and 5-year rates of (1) ISTH-defined major bleeding and (2) the composite of cardiovascular death, all stroke, systemic embolism, and nonprocedural ISTH bleeding. CONCLUSIONS: This study will prospectively evaluate whether LAAC with the Watchman FLX device is a reasonable alternative to DOACs in patients with AF. CLINICAL TRIAL REGISTRATION: NCT04394546.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Embolism , Stroke , Male , Humans , Female , Atrial Fibrillation/complications , Atrial Fibrillation/drug therapy , Treatment Outcome , Follow-Up Studies , Atrial Appendage/surgery , Anticoagulants/therapeutic use , Stroke/etiology , Stroke/prevention & control , Stroke/epidemiology , Hemorrhage/chemically induced , Hemorrhage/complications , Aspirin/therapeutic use , Embolism/prevention & control
17.
J Cardiovasc Electrophysiol ; 34(8): 1690-1697, 2023 08.
Article in English | MEDLINE | ID: mdl-37417961

ABSTRACT

INTRODUCTION: Transseptal puncture (TSP) to allow for large delivery sheath left atrial (LA) access remains a challenging aspect of LA appendage closure (LAAC) in patients with prior history of TSP, thick or lipomatous septum, atrial septal aneurysms, or other complex cardiac anatomies. This study investigates the use of the VersaCross large access (VLA) system (Baylis Medical/Boston Scientific) to improve procedural efficiency of LAAC compared to the standard needle workflow. METHODS AND RESULTS: Fifty LAAC procedures using WATCHMAN FLX between November 2021 and September 2022 were retrospectively analyzed comparing the VLA workflow (n = 25) to the standard needle workflow (n = 25). Study primary endpoint was time to procedural efficiency, and secondary endpoints included TSP time, acute LAAC success, fluoroscopy use, device recaptures, and periprocedural complications. Acute LAAC was successfully completed in all cases with no intraprocedural complications. TSP time was faster, but not significant, using the VLA workflow compared to the standard RF needle workflow (2.6 ± 1.1 min vs. 3.0 ± 1.8 min, p = 0.38). Time to WATCHMAN sheath in LA from TSP was 27% faster (1.5 ± 0.8 min vs. 2.1 ± 0.9 min; p = 0.03), and time to WATCHMAN release from TSP was 19% faster (10.5. ± 2.5 min vs. 13.0 ± 3.7 min; p = 0.01) with the VLA workflow. Overall procedure time was 15% faster (30.4 ± 5.1 min vs. 36.0 ± 6.6 min; p = 0.003) using VLA. Fluoroscopy time was 25% lower (4.0 ± 2.2 min vs. 5.5 ± 2.3 min; p = 0.003) and fluoroscopy dose was 60% lower (97.0 ± 91.7 mGy vs. 241.8 ± 240.6 mGy; p = 0.01) and more consistent [F-test, p ˂ 0.0001] using the VLA workflow compared to the needle workflow. CONCLUSION: The VLA system streamlines LAAC procedures, improving LAAC efficiency and reducing fluoroscopy use by allowing for de novo dilation of the septum for large-bore delivery sheaths, and reducing device exchanges and delivery sheath manipulation.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Retrospective Studies , Cardiac Catheterization , Heart Atria , Treatment Outcome
18.
J Cardiovasc Electrophysiol ; 34(12): 2493-2503, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37870157

ABSTRACT

INTRODUCTION: The prospective, nonrandomized, multicenter Q-FFICIENCY study demonstrated the safety and 12-month efficacy of paroxysmal atrial fibrillation (AF) ablation with the novel QDOT MICRO temperature-controlled, contact force-sensing, radiofrequency (RF) catheter. Participants underwent pulmonary vein isolation with very high-power short-duration (vHPSD) mode (90 W, ≤4 s) alone or combined with conventional-power temperature-controlled (CPTC) mode (25-50 W). This study aimed to assess quality-of-life (QOL) and healthcare utilization (HCU) benefits experienced by Q-FFICIENCY study participants. METHODS: Besides evaluating procedural efficiency, QOL and HCU were assessed through 12 months postablation via Atrial Fibrillation Effect on Quality-of-Life Tool (AFEQT) score, antiarrhythmic drug (AAD) use, and incidence of cardioversion and cardiovascular hospitalization. RESULTS: Of 191 participants enrolled, 166 were ablated with the new catheter. Compared to baseline, statistically significant, clinically meaningful improvements in composite and subcategories of AFEQT scores were observed at 3 months and sustained through 12 months (12-month increase, 29.3-44.2 points). Class I/III AAD use decreased from 97.6% (162/166) at baseline to 19.6% (31/158) during Months 6-12, representing a significant 79.9% reduction. The cardioversion rate significantly declined by 93.9% from 31.3% (12 months preablation) to 1.9% (evaluation period). One-year Kaplan-Meier estimates of freedom from all-cause and cardiovascular hospitalization were 80.9% (95% confidence interval [CI], 74.8%-86.9%) and 88.8% (95% CI, 84.0%-93.7%), respectively. CONCLUSIONS: Paroxysmal AF ablation with the novel temperature-controlled RF catheter in vHPSD mode, alone or with CPTC mode, led to clinically meaningful improvement in QOL and significant reduction in AAD use, cardioversion, and cardiovascular hospitalization.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Prospective Studies , Quality of Life , Temperature , Treatment Outcome , Catheters , Anti-Arrhythmia Agents/therapeutic use , Pulmonary Veins/surgery , Patient Acceptance of Health Care , Catheter Ablation/adverse effects
19.
J Cardiovasc Electrophysiol ; 34(10): 2136-2144, 2023 10.
Article in English | MEDLINE | ID: mdl-36069138

ABSTRACT

This article reviews the latest available data in regard to the diagnosis, management, and intervention of both central and peri-device leaks that arise after left atrial appendage closure (LAAC). The aim of this article is to have a better understanding of both addressing leaks arising after LAAC, and which interventions and closure methods are best served for each type of residual leak based on etiology, size, and operator experience.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Treatment Outcome , Cardiac Catheterization/adverse effects
20.
J Cardiovasc Electrophysiol ; 34(5): 1216-1227, 2023 05.
Article in English | MEDLINE | ID: mdl-37087672

ABSTRACT

INTRODUCTION: The assessment of the ventricular myocardial substrate critically depends on the size of mapping electrodes, their orientation with respect to wavefront propagation, and interelectrode distance. We conducted a dual-center study to evaluate the impact of microelectrode mapping in patients undergoing catheter ablation (CA) of ventricular tachycardia (VT). METHODS: We included 21 consecutive patients (median age, 68 [12], 95% male) with structural heart disease undergoing CA for electrical storm (n = 14) or recurrent VT (n = 7) using the QDOT Micro catheter and a multipolar catheter (PentaRay, n = 9). The associations of peak-to-peak maximum standard bipolar (BVc ) and minibipolar (PentaRay, BVp ) with microbipolar (BVµMax ) voltages were respectively tested in sinus rhythm with mixed effect models. Furthermore, we compared the features of standard bipolar (BE) and microbipolar (µBE) electrograms in sinus rhythm at sites of termination with radiofrequency energy. RESULTS: BVµMax was moderately associated with both BVc (ß = .85, p < .01) and BVp (ß = .56, p < .01). BVµMax was 0.98 (95% CI: 0.93-1.04, p < .01) mV larger than corresponding BVc , and 0.27 (95% CI: 0.16-0.37, p < .01) mV larger than matching BVp in sinus rhythm, with higher percentage differences in low voltage regions, leading to smaller endocardial dense scar (2.3 [2.7] vs. 12.1 [17] cm2 , p < .01) and border zone (3.2 [7.4] vs. 4.8 [20.1] cm2 , p = .03) regions in microbipolar maps compared to standard bipolar maps. Late potentials areas were nonsignificantly greater in microelectrode maps, compared to standard electrode maps. At sites of VT termination (n = 14), µBE were of higher amplitude (0.9 [0.8] vs. 0.4 [0.2] mV, p < .01), longer duration (117 [66] vs. 74 [38] ms, p < .01), and with greater number of peaks (4 [2] vs. 2 [1], p < .01) in sinus rhythm compared to BE. CONCLUSION: microelectrode mapping is more sensitive than standard bipolar mapping in the identification of viable myocytes in SR, and may facilitate recognition of targets for CA.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Male , Aged , Female , Microelectrodes , Treatment Outcome , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/complications , Arrhythmias, Cardiac/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cicatrix