Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Trials ; 25(1): 331, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38773658

ABSTRACT

BACKGROUND: Self-monitoring of glucose is an essential component of type 1 diabetes (T1D) management. In recent years, continuous glucose monitoring (CGM) has provided an alternative to daily fingerstick testing for the optimisation of insulin dosing and general glucose management in people with T1D. While studies have been conducted to evaluate the impact of CGM on clinical outcomes in the US, Europe and Australia, there are limited data available for low- and middle-income countries (LMICs) and further empirical evidence is needed to inform policy decision around their use in these countries. METHODS: This trial was designed as a pragmatic, parallel-group, open-label, multicentre, three-arm, randomised (1:1:1) controlled trial of continuous or periodic CGM device use versus standard of care in people with T1D in South Africa and Kenya. The primary objective of this trial will be to assess the impact of continuous or periodic CGM device use on glycaemic control as measured by change from baseline glycosylated haemoglobin (HbA1c). Additional assessments will include clinical outcomes (glucose variation, time in/below/above range), safety (adverse events, hospitalisations), quality of life (EQ-5D, T1D distress score, Glucose Monitoring Satisfaction Survey for T1D), and health economic measures (incremental cost-effectiveness ratios, quality adjusted life years). DISCUSSION: This trial aims to address the substantial evidence gap on the impact of CGM device use on clinical outcomes in LMICs, specifically South Africa and Kenya. The trial results will provide evidence to inform policy and treatment decisions in these countries. TRIAL REGISTRATION: NCT05944731 (Kenya), July 6, 2023; NCT05944718 (South Africa), July 13, 2023.


Subject(s)
Diabetes Mellitus, Type 1 , Glycated Hemoglobin , Humans , Blood Glucose/analysis , Continuous Glucose Monitoring/instrumentation , Cost-Benefit Analysis , Diabetes Mellitus, Type 1/diagnosis , Diabetes Mellitus, Type 1/drug therapy , Glycated Hemoglobin/analysis , Glycemic Control/instrumentation , Hypoglycemic Agents/therapeutic use , Implementation Science , Insulin/therapeutic use , Kenya , Multicenter Studies as Topic , Pragmatic Clinical Trials as Topic , Quality of Life , South Africa , Treatment Outcome
2.
Int J Public Health ; 67: 1604918, 2022.
Article in English | MEDLINE | ID: mdl-36090834

ABSTRACT

Objectives: To understand the public's perceptions around rapid SARS-CoV-2 antigen self-testing in Kenya, including the drivers of acceptability, willingness to pay, and adherence to hygiene and prevention recommendations following a positive self-test. Methods: A household-based, cross-sectional survey, using a 35-item questionnaire, was conducted in Mombasa and Taita-Taveta counties, Kenya, during August 2021. Individuals aged ≥18 years were enrolled using a stratified sampling approach. Results: There were 419 participants (mean age 35.7 years). A minority (10.5%) had ever tested for SARS-CoV-2. If SARS-CoV-2 self-testing were available, 39.9% and 41.5% would be likely and very likely, respectively, to use it. If unavailable free-of-charge, 63.01% would pay for it. Multivariate analyses suggested that people in rural areas (Coefficient 0.30, 95%CI: 0.11-0.48, p = 0.002), aged 36-55 (Coefficient 0.21, 95%CI: 0.03-0.40, p = 0.023), and employed full time (Coefficient 0.32, 95%CI: 0.06-0.58, p = 0.016) would have more odds to adhere to recommended hygiene and prevention actions. Conclusion: SARS-CoV-2 self-testing was considered acceptable. Availability of self-testing could expand access to COVID-19 testing in Kenya, particularly among rural communities who have limited access to testing, and among mildly symptomatic individuals.


Subject(s)
COVID-19 , HIV Infections , Adolescent , Adult , COVID-19/diagnosis , COVID-19/prevention & control , COVID-19 Testing , Cross-Sectional Studies , Humans , Kenya , SARS-CoV-2 , Self-Testing
3.
Sci Rep ; 12(1): 18069, 2022 10 27.
Article in English | MEDLINE | ID: mdl-36302782

ABSTRACT

Despite the availability of highly sensitive polymerase chain reaction (PCR)-based methods, the dearth of remotely deployable diagnostic tools circumvents the early and accurate detection of individuals with post-kala-azar dermal leishmaniasis (PKDL). Here, we evaluate a design-locked loop-mediated isothermal amplification (LAMP) assay to diagnose PKDL. A total of 76 snip-skin samples collected from individuals with probable PKDL (clinical presentation and a positive rK39 rapid diagnostic test (RDT)) were assessed by microscopy, qPCR, and LAMP. An equal number of age and sex-matched healthy controls were included to determine the specificity of the LAMP assay. The LAMP assay with a Qiagen DNA extraction (Q-LAMP) showed a promising sensitivity of 72.37% (95% CI: 60.91-82.01%) for identifying the PKDL cases. LAMP assay sensitivity declined when the DNA was extracted using a boil-spin method. Q-qPCR showed 68.42% (56.75-78.61%) sensitivity, comparable to LAMP and with an excellent agreement, whereas the microscopy exhibited a weak sensitivity of 39.47% (28.44-51.35%). When microscopy and/or qPCR were considered the gold standard, Q-LAMP exhibited an elevated sensitivity of 89.7% (95% CI: 78.83-96.11%) for detection of PKDL cases and Bayesian latent class modeling substantiated the excellent sensitivity of the assay. All healthy controls were found to be negative. Notwithstanding the optimum efficiency of the LAMP assay towards the detection of PKDL cases, further optimization of the boil-spin method is warranted to permit remote use of the assay.


Subject(s)
Leishmania donovani , Leishmaniasis, Cutaneous , Leishmaniasis, Visceral , Parasites , Skin Diseases, Parasitic , Animals , Humans , Leishmaniasis, Visceral/diagnosis , Leishmania donovani/genetics , Parasites/genetics , Leishmaniasis, Cutaneous/diagnosis , Leishmaniasis, Cutaneous/parasitology , Bayes Theorem , Real-Time Polymerase Chain Reaction
5.
J Trop Med ; 2012: 340538, 2012.
Article in English | MEDLINE | ID: mdl-22545057

ABSTRACT

Human African trypanosomiasis is a debilitating disease prevalent in rural sub-Saharan Africa. Control of this disease almost exclusively relies on chemotherapy that should be driven by accurate diagnosis, given the unacceptable toxicity of the few available drugs. Unfortunately, the available diagnostics are characterised by low sensitivities due to the inherent low parasitaemia in natural infections. Demonstration of the trypanosomes in body fluids, which is a prerequisite before treatment, often follows complex algorithms. In this paper, we review the available diagnostics and explore recent advances towards development of novel point-of-care diagnostic tests.

SELECTION OF CITATIONS
SEARCH DETAIL