ABSTRACT
BACKGROUND: The emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants threatens progress toward control of the coronavirus disease 2019 (Covid-19) pandemic. In a phase 1-2 trial involving healthy adults, the NVX-CoV2373 nanoparticle vaccine had an acceptable safety profile and was associated with strong neutralizing-antibody and antigen-specific polyfunctional CD4+ T-cell responses. Evaluation of vaccine efficacy was needed in a setting of ongoing SARS-CoV-2 transmission. METHODS: In this phase 2a-b trial in South Africa, we randomly assigned human immunodeficiency virus (HIV)-negative adults between the ages of 18 and 84 years or medically stable HIV-positive participants between the ages of 18 and 64 years in a 1:1 ratio to receive two doses of either the NVX-CoV2373 vaccine (5 µg of recombinant spike protein with 50 µg of Matrix-M1 adjuvant) or placebo. The primary end points were safety and vaccine efficacy against laboratory-confirmed symptomatic Covid-19 at 7 days or more after the second dose among participants without previous SARS-CoV-2 infection. RESULTS: Of 6324 participants who underwent screening, 4387 received at least one injection of vaccine or placebo. Approximately 30% of the participants were seropositive for SARS-CoV-2 at baseline. Among 2684 baseline seronegative participants (94% HIV-negative and 6% HIV-positive), predominantly mild-to-moderate Covid-19 developed in 15 participants in the vaccine group and in 29 in the placebo group (vaccine efficacy, 49.4%; 95% confidence interval [CI], 6.1 to 72.8). Vaccine efficacy among HIV-negative participants was 60.1% (95% CI, 19.9 to 80.1). Of 41 sequenced isolates, 38 (92.7%) were the B.1.351 variant. Post hoc vaccine efficacy against B.1.351 was 51.0% (95% CI, -0.6 to 76.2) among the HIV-negative participants. Preliminary local and systemic reactogenicity events were more common in the vaccine group; serious adverse events were rare in both groups. CONCLUSIONS: The NVX-CoV2373 vaccine was efficacious in preventing Covid-19, with higher vaccine efficacy observed among HIV-negative participants. Most infections were caused by the B.1.351 variant. (Funded by Novavax and the Bill and Melinda Gates Foundation; ClinicalTrials.gov number, NCT04533399.).
Subject(s)
COVID-19 Vaccines/immunology , COVID-19/prevention & control , Immunogenicity, Vaccine , SARS-CoV-2 , Adolescent , Adult , Aged , Aged, 80 and over , Antibodies, Neutralizing/blood , COVID-19/epidemiology , COVID-19/immunology , COVID-19/virology , COVID-19 Serological Testing , COVID-19 Vaccines/adverse effects , Double-Blind Method , HIV Seronegativity , HIV Seropositivity , Humans , Middle Aged , SARS-CoV-2/isolation & purification , South Africa , Young AdultABSTRACT
BACKGROUND: NVX-CoV2373 is a recombinant severe acute respiratory syndrome coronavirus 2 (rSARS-CoV-2) nanoparticle vaccine composed of trimeric full-length SARS-CoV-2 spike glycoproteins and Matrix-M1 adjuvant. METHODS: We initiated a randomized, placebo-controlled, phase 1-2 trial to evaluate the safety and immunogenicity of the rSARS-CoV-2 vaccine (in 5-µg and 25-µg doses, with or without Matrix-M1 adjuvant, and with observers unaware of trial-group assignments) in 131 healthy adults. In phase 1, vaccination comprised two intramuscular injections, 21 days apart. The primary outcomes were reactogenicity; laboratory values (serum chemistry and hematology), according to Food and Drug Administration toxicity scoring, to assess safety; and IgG anti-spike protein response (in enzyme-linked immunosorbent assay [ELISA] units). Secondary outcomes included unsolicited adverse events, wild-type virus neutralization (microneutralization assay), and T-cell responses (cytokine staining). IgG and microneutralization assay results were compared with 32 (IgG) and 29 (neutralization) convalescent serum samples from patients with Covid-19, most of whom were symptomatic. We performed a primary analysis at day 35. RESULTS: After randomization, 83 participants were assigned to receive the vaccine with adjuvant and 25 without adjuvant, and 23 participants were assigned to receive placebo. No serious adverse events were noted. Reactogenicity was absent or mild in the majority of participants, more common with adjuvant, and of short duration (mean, ≤2 days). One participant had mild fever that lasted 1 day. Unsolicited adverse events were mild in most participants; there were no severe adverse events. The addition of adjuvant resulted in enhanced immune responses, was antigen dose-sparing, and induced a T helper 1 (Th1) response. The two-dose 5-µg adjuvanted regimen induced geometric mean anti-spike IgG (63,160 ELISA units) and neutralization (3906) responses that exceeded geometric mean responses in convalescent serum from mostly symptomatic Covid-19 patients (8344 and 983, respectively). CONCLUSIONS: At 35 days, NVX-CoV2373 appeared to be safe, and it elicited immune responses that exceeded levels in Covid-19 convalescent serum. The Matrix-M1 adjuvant induced CD4+ T-cell responses that were biased toward a Th1 phenotype. (Funded by the Coalition for Epidemic Preparedness Innovations; ClinicalTrials.gov number, NCT04368988).
Subject(s)
COVID-19 Vaccines/immunology , COVID-19/prevention & control , Spike Glycoprotein, Coronavirus/immunology , Adjuvants, Immunologic/administration & dosage , Adolescent , Adult , Antibodies, Neutralizing/immunology , Antibodies, Viral/immunology , COVID-19 Vaccines/adverse effects , Enzyme-Linked Immunosorbent Assay , Female , Humans , Immunization Schedule , Immunogenicity, Vaccine , Immunoglobulin G/immunology , Male , Middle Aged , Nanoparticles , Pandemics , Saponins , Th1 Cells/immunology , Vaccines, Synthetic/adverse effects , Vaccines, Synthetic/immunology , Young AdultABSTRACT
BACKGROUND: There is a paucity of data on COVID-19 vaccines in people living with HIV-1, who could be at increased risk of severe illness and death from COVID-19. We evaluated the safety and immunogenicity of a Matrix-M adjuvanted recombinant spike protein nanoparticle COVID-19 vaccine (NVX-CoV2373; Novavax) in HIV-negative people and people living with HIV-1. METHODS: In this randomised, observer-blinded, multicentre, placebo-controlled phase 2A/B trial in South Africa, participants aged 18-84 years, with and without underlying HIV-1, were enrolled from 16 sites and randomly assigned (1:1) to receive two intramuscular injections of NVX-CoV2373 or placebo, 21 days apart. People living with HIV-1 were on stable antiretroviral therapy and had an HIV-1 viral load of less than 1000 copies per mL. Vaccine dosage was 5 µg SARS-CoV-2 recombinant spike protein with 50 µg Matrix-M adjuvant, whereas 0·9% saline was used as placebo injection (volume 0·5 mL each). All study staff and participants remained masked to study group assignment. We previously reported an interim analysis on the efficacy and safety of the NVX-CoV2373 vaccine (coprimary endpoints). In this Article, we present an expanded safety analysis for the full cohort of participants and report on the secondary objective of vaccine immunogenicity in the full cohort of people living with HIV-1 and in HIV-negative individuals overall and stratified by baseline SARS-CoV-2 serostatus. This trial is registered with ClinicalTrials.gov, NCT04533399, and the Pan-African Clinical Trials Registry, PACTR202009726132275. FINDINGS: Participants were enrolled between Aug 17 and Nov 25, 2020. The safety analysis set included 4164 HIV-negative participants (2089 in the intervention group and 2075 in the placebo group) and 244 people living with HIV-1 (122 in the intervention group and 122 in the placebo group). 1422 (34·1%) of 4164 HIV-negative people and 83 (34·0%) of 244 people living with HIV-1 were categorised as baseline SARS-CoV-2-positive (ie, anti-spike IgG reactive at enrolment or had a reactive SARS-CoV-2 nucleic acid amplification test by 14 days after the second study vaccination). In the NVX-CoV2373 group, solicited local and systemic adverse events were more common in HIV-negative participants (427 [30·6%] local and 401 [28·7%] systemic) than in people living with HIV-1 (20 [25·3%] local and 20 [25·3%] systemic) among those who were baseline SARS-CoV-2-seronegative (naive). Of the serious adverse events that occurred among HIV-negative people (of whom, two [0·1%] were baseline SARS-CoV-2-negative and four [0·6%] were baseline SARS-CoV-2-positive) and people living with HIV-1 (for whom there were no serious adverse events) in the NVX-CoV2373 group, none were assessed as related to the vaccine. Among participants who were baseline SARS-CoV-2-negative in the NVX-CoV2373 group, the anti-spike IgG geometric mean titres (GMTs) and seroconversion rates (SCRs) were lower in people living with HIV-1 (n=62) than in HIV-negative people (n=1234) following the first vaccination (GMT: 508·6 vs 1195·3 ELISA units [EU]/mL; SCR: 51·6% vs 81·3%); and similarly so 14 days after the second vaccination for GMTs (14â420·5 vs 31â631·8 EU/mL), whereas the SCR was similar at this point (100·0% vs 99·3%). In the NVX-CoV2373 group, anti-spike IgG GMTs 14 days after the second vaccination were substantially higher in those who were baseline SARS-CoV-2-positive than in those who were baseline SARS-CoV-2-seronegative for HIV-negative participants (100â666·1 vs 31â631·8 EU/mL) and for people living with HIV-1 (98â399·5 vs 14â420·5 EU/mL). This was also the case for angiotensin-converting enzyme 2 receptor-binding antibody and neutralising antibody titres. INTERPRETATION: The safety of the NVX-CoV2373 vaccine in people living with HIV-1 was similar to that in HIV-negative participants. However, people living with HIV-1 not previously exposed to SARS-CoV-2 had attenuated humoral immune responses to NVX-CoV2373 compared with their HIV-negative vaccine counterparts, but not so if they were baseline SARS-CoV-2-positive. FUNDING: Novavax and the Bill & Melinda Gates Foundation; investigational vaccine manufacturing support was provided by the Coalition for Epidemic Preparedness Innovations.
Subject(s)
COVID-19 , HIV Infections , HIV Seropositivity , HIV-1 , Nanoparticles , Viral Vaccines , Adjuvants, Immunologic , Antibodies, Viral , COVID-19/prevention & control , COVID-19 Vaccines/adverse effects , Humans , Immunoglobulin G , SARS-CoV-2 , Spike Glycoprotein, CoronavirusABSTRACT
The overall efficacy of transthoracic biphasic shocks delivered for conversion of atrial fibrillation (AF) has been demonstrated. We compared 2 different energy waveforms, either the biphasic rectilinear (BRL) waveform or the biphasic truncated exponential (BTE) waveform, in the conversion of AF to sinus rhythm. The relation between energy required for the conversion of AF, the type of biphasic waveform, and patient characteristics were examined. Serum levels of cardiac troponin I were measured before and after cardioversion, as well as postprocedural skin erythema and discomfort. In this prospective trial, 101 patients (mean age 61 +/- 15 years, 72 men [71%]) referred for elective electrical cardioversion of AF were randomized to either a BTE or a BRL device. Shocks were delivered in a step-up fashion beginning with 50 J (then 100 J, 200 J, repeat 200 J, and then crossover to 360 J). One hundred patients were successfully converted to sinus rhythm (99% success rate). There was no difference in efficacy at any energy level used, regardless of the duration of the arrhythmia. In addition, there was no difference in cumulative success. Troponin I did not significantly increase after cardioversion, regardless of the total energy used. A positive correlation between skin erythema and skin discomfort after shock (24 to 48 hours) was seen with increasing cumulative energies. There was also a positive trend toward increasing energy requirements as chest circumference and body mass index increased. Thus, biphasic waveforms are safe and effective at converting AF to sinus rhythm. In this study population, there was no clinical difference between the BRL and the BTE waveforms.