Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters

Database
Language
Journal subject
Affiliation country
Publication year range
1.
Eur Radiol ; 31(2): 640-649, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32870393

ABSTRACT

OBJECTIVES: Simultaneous multi-slice (SMS) imaging with short repetition time (TR) accelerates diffusion tensor imaging (DTI) acquisitions. However, its impact when combined with readout-segmented echo planar imaging (RESOLVE) on the cranial nerves given the challenging skull base/posterior fossa terrain is unexplored. We evaluated the reliability of trigeminal nerve DTI metrics using SMS with RESOLVE-DTI. METHODS: Eight healthy controls and six patients with unilateral trigeminal neuralgia (TN) underwent brain MRI scan. Three different RESOLVE-DTI protocols were performed on a 3-T MRI system: non-SMS (TR = 4330 ms), SMS with identical TR (4330 ms), and SMS with short TR (2400 ms). Pontine signal-to-noise ratio (SNR) and DTI metrics of the trigeminal nerve streamlines tracked by two independent raters using deterministic tractography and standardized tracking protocol were obtained. These were statistically analyzed and compared across the three protocols using intra-rater and inter-rater intraclass correlation coefficients (ICCs), one-way analysis of variance (ANOVA), post hoc analysis, and linear regression. RESULTS: On visual screening, there were no artifacts across the trigeminal nerves. All data also cleared objective image quality assurance analysis. Pontine SNR was similar for the two SMS protocols and higher for the non-SMS RESOLVE-DTI (F(2,36) = 4.40, p = 0.02). Intra-rater and inter-rater ICCs were very good (> 0.85). Trigeminal nerve DTI metrics were consistently measured by the three protocols, revealing significant linear relationships between non-SMS- and SMS-derived DTI metrics. CONCLUSION: SMS RESOLVE-DTI enables fast and reliable evaluation of microstructural integrity of the trigeminal nerve, with potential application in the clinical management of TN. KEY POINTS: • Readout-segmented diffusion-weighted echo planar imaging (RESOLVE-DTI) reduces image distortion artifacts in the posterior fossa but its long acquisition time limits clinical utility. • Simultaneous multi-slice (SMS) imaging combined with RESOLVE-DTI provides reliable trigeminal nerve tractography with potential applications in trigeminal neuralgia. • Two-fold-accelerated RESOLVE-DTI yields comparable trigeminal nerve streamlines and DTI metrics while near-halving acquisition time.


Subject(s)
Diffusion Tensor Imaging , Echo-Planar Imaging , Humans , Reproducibility of Results , Signal-To-Noise Ratio , Trigeminal Nerve/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL