Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 38
Filter
Add more filters

Country/Region as subject
Publication year range
1.
J Neurooncol ; 139(1): 145-152, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29767308

ABSTRACT

INTRODUCTION: Pseudoprogression (PsP) is a diagnostic dilemma in glioblastoma (GBM) after chemoradiotherapy (CRT). Magnetic resonance imaging (MRI) features may fail to distinguish PsP from early true progression (eTP), however clinical findings may aid in their distinction. METHODS: Sixty-seven patients received CRT for GBM between 2003 and 2016, and had pre- and post-treatment imaging suitable for retrospective evaluation using RANO criteria. Patients with signs of progression within the first 12-weeks post-radiation (P-12) were selected. Lesions that improved or stabilized were defined as PsP, and lesions that progressed were defined as eTP. RESULTS: The median follow up for all patients was 17.6 months. Signs of progression developed in 35/67 (52.2%) patients within P-12. Of these, 20/35 (57.1%) were subsequently defined as eTP and 15/35 (42.9%) as PsP. MRI demonstrated increased contrast enhancement in 84.2% of eTP and 100% of PsP, and elevated CBV in 73.7% for eTP and 93.3% for PsP. A decrease in FLAIR was not seen in eTP patients, but was seen in 26.7% PsP patients. Patients with eTP were significantly more likely to require increased steroid doses or suffer clinical decline than PsP patients (OR 4.89, 95% CI 1.003-19.27; p = 0.046). KPS declined in 25% with eTP and none of the PsP patients. CONCLUSIONS: MRI imaging did not differentiate eTP from PsP, however, KPS decline or need for increased steroids was significantly more common in eTP versus PsP. Investigation and standardization of clinical assessments in response criteria may help address the diagnostic dilemma of pseudoprogression after frontline treatment for GBM.


Subject(s)
Brain Neoplasms/diagnostic imaging , Brain Neoplasms/therapy , Glioblastoma/diagnostic imaging , Glioblastoma/therapy , Magnetic Resonance Imaging , Brain/diagnostic imaging , Chemoradiotherapy , Contrast Media , Disease Progression , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Steroids/therapeutic use , Treatment Outcome
2.
Oncology (Williston Park) ; 31(3): 182-8, 2017 Mar 15.
Article in English | MEDLINE | ID: mdl-28299754

ABSTRACT

Radiation therapy continues to be a key component in the management of pediatric malignancies. Increasing the likelihood of cure while minimizing late treatment toxicity in these young patients remains the primary goal. Within the realm of central nervous system neoplasms, efforts to further improve the efficacy of radiation therapy continue, while balancing risks of damage to uninvolved tissue. Radiation therapy can result in second malignancies, as well as cerebrovascular, neurotoxic, neurocognitive, endocrine, psychosocial, and quality-of-life effects. In this article we describe these acute and late effects and their implications, and we highlight strategies that have emerged to reduce both the volume of tissue that is irradiated and the radiation dose delivered. The feasibility, efficacy, and risks of these newer approaches to radiation therapy continue to be evaluated and monitored; robust outcome data are needed.


Subject(s)
Central Nervous System Neoplasms/radiotherapy , Cranial Irradiation/adverse effects , Radiation Injuries/therapy , Survivors , Adult , Age Factors , Central Nervous System Neoplasms/diagnosis , Child , Humans , Quality of Life , Radiation Dosage , Radiation Injuries/diagnosis , Radiation Injuries/etiology , Radiation Injuries/psychology , Risk Factors , Survivors/psychology , Time Factors , Treatment Outcome
3.
Oncology (Williston Park) ; 31(3): 224-6, 228, 2017 Mar 15.
Article in English | MEDLINE | ID: mdl-28299759

ABSTRACT

Newer approaches in the field of radiation therapy have raised the bar in the treatment of central nervous system (CNS) malignancies, with recognized advances that have aimed to increase the therapeutic index by improving conformality of the radiation dose to the planned target volume. Beyond these advances, the continued evolution of more effective systems for delivery of radiation to the CNS may offer further benefit not only to adults but also to pediatric patients, a cohort of the population that may be more sensitive to the long-term effects of radiation. This article describes several novel irradiation techniques under investigation that hold promise in the pediatric population. These include newer approaches to intensity-modulated radiation therapy; stereotactic radiosurgery and radiation therapy; particle therapy, most notably proton therapy, which may be of particular benefit in enabling young patients to avoid radiation-related adverse effects; and radioimmunotherapy strategies that spare healthy tissue from radiotoxicity by delivering therapy directly to tumor tissue. Although emerging strategies for the delivery of radiation therapy hold promise for improved outcomes in pediatric patients, there must be rigorous long-term evaluation of consequences associated with the various techniques employed, to weigh risks, benefits, and impact on quality of life.


Subject(s)
Central Nervous System Neoplasms/radiotherapy , Cranial Irradiation/methods , Radiation Dosage , Radioimmunotherapy , Radiosurgery , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated , Survivors , Adult , Age Factors , Central Nervous System Neoplasms/diagnosis , Child , Cranial Irradiation/adverse effects , Humans , Quality of Life , Radiation Injuries/etiology , Radiation Injuries/prevention & control , Radiosurgery/adverse effects , Radiotherapy, Intensity-Modulated/adverse effects , Risk Factors , Time Factors , Treatment Outcome
4.
J Appl Clin Med Phys ; 17(3): 100-110, 2016 05 08.
Article in English | MEDLINE | ID: mdl-27167266

ABSTRACT

The dose measurements of the small field sizes, such as conical collimators used in stereotactic radiosurgery (SRS), are a significant challenge due to many factors including source occlusion, detector size limitation, and lack of lateral electronic equilibrium. One useful tool in dealing with the small field effect is Monte Carlo (MC) simulation. In this study, we report a comparison of Monte Carlo simulations and measurements of output factors for the Varian SRS system with conical collimators for energies of 6 MV flattening filter-free (6 MV) and 10 MV flattening filter-free (10 MV) on the TrueBeam accelerator. Monte Carlo simulations of Varian's SRS system for 6 MV and 10 MV photon energies with cones sizes of 17.5 mm, 15.0 mm, 12.5 mm, 10.0 mm, 7.5 mm, 5.0 mm, and 4.0 mm were performed using EGSnrc (release V4 2.4.0) codes. Varian's version-2 phase-space files for 6 MV and 10 MV of TrueBeam accelerator were utilized in the Monte Carlo simulations. Two small diode detectors Edge (Sun Nuclear) and Small Field Detector (SFD) (IBA Dosimetry) were applied to measure the output factors. Significant errors may result if detector correction factors are not applied to small field dosimetric measurements. Although it lacked the machine-specific kfclin,fmsrQclin,Qmsr correction factors for diode detectors in this study, correction factors were applied utilizing published studies conducted under similar conditions. For cone diameters greater than or equal to 12.5 mm, the differences between output factors for the Edge detector, SFD detector, and MC simulations are within 3.0% for both energies. For cone diameters below 12.5 mm, output factors differences exhibit greater variations.


Subject(s)
Algorithms , Monte Carlo Method , Phantoms, Imaging , Radiometry/instrumentation , Radiosurgery , Computer Simulation , Humans , Photons , Radiotherapy Planning, Computer-Assisted , Water
5.
Article in English | MEDLINE | ID: mdl-38428681

ABSTRACT

PURPOSE: NCT03253744 is a phase 1 trial with the primary objective to identify the maximum tolerated dose (MTD) of salvage stereotactic body radiation therapy (SBRT) in patients with local prostate cancer recurrence after brachytherapy. Additional objectives included biochemical control and imaging response. METHODS AND MATERIALS: This trial was initially designed to test 3 therapeutic dose levels (DLs): 40 Gy (DL1), 42.5 Gy (DL2), and 45 Gy (DL3) in 5 fractions. Intensity modulation was used to deliver the prescription dose to the magnetic resonance imaging and prostate-specific membrane antigen-based positron emission tomography imaging-defined gross tumor volume while simultaneously delivering 30 Gy to an elective volume defined by the prostate gland. This phase 1 trial followed a 3+3 design with a 3-patient expansion at the MTD. Toxicities were scored until trial completion at 2 years post-SBRT using Common Terminology Criteria for Adverse Events version 5.0. Escalation was halted if 2 dose limiting toxicities occurred, defined as any persistent (>4 days) grade 3 toxicity occurring within the first 3 weeks after SBRT or any grade ≥3 genitourinary (GU) or grade 4 gastrointestinal toxicity thereafter. RESULTS: Between August 2018 and January 2023, 9 patients underwent salvage SBRT and were observed for a median of 22 months (Q1-Q3, 20-43 months). No grade 3 to 5 adverse events related to study treatment were observed; thus, no dose limiting toxicities occurred during the observation period. Escalation was halted by amendment given excellent biochemical control in DL1 and DL2 in the setting of a high incidence of clinically significant late grade 2 GU toxicity. Therefore, the MTD was considered 42.5 Gy in 5 fractions (DL2). One- and 2-year biochemical progression-free survival were 100% and 86%, representing a single patient in the trial cohort with biochemical failure (prostate-specific antigen [PSA] nadir + 2.0) at 20 months posttreatment. CONCLUSIONS: The MTD of salvage SBRT for the treatment of intraprostatic radiorecurrence after brachytherapy was 42.5 Gy in 5 fractions producing an 86% 2-year biochemical progression-free survival rate, with 1 poststudy failure at 20 months. The most frequent clinically significant toxicity was late grade 2 GU toxicity.

6.
Pract Radiat Oncol ; 13(6): 540-550, 2023.
Article in English | MEDLINE | ID: mdl-37442430

ABSTRACT

PURPOSE: NCT03253744 was a phase 1 trial to identify the maximum tolerated dose (MTD) of image-guided, focal, salvage stereotactic body radiation therapy (SBRT) for patients with locally radiorecurrent prostate cancer. Additional objectives included biochemical control and imaging response. METHODS AND MATERIALS: The trial design included 3 dose levels (DLs): 40 Gy (DL1), 42.5 Gy (DL2), and 45 Gy (DL3) in 5 fractions delivered ≥48 hours apart. The prescription dose was delivered to the magnetic resonance- and prostate-specific membrane antigen imaging-defined tumor volume. Dose escalation followed a 3+3 design with a 3-patient expansion at the MTD. Toxicities were scored until 2 years after completion of SBRT using Common Terminology Criteria for Adverse Events, version 5.0, criteria. Escalation was halted if 2 dose-limiting toxicities occurred, defined as any persistent (>4 days) grade 3 toxicity occurring within the first 3 weeks after SBRT and any grade 3 genitourinary (GU) or grade 4 gastrointestinal (GI) toxicity thereafter. RESULTS: Between August 2018 and May 2022, 8 patients underwent salvage focal SBRT, with a median follow-up of 35 months. No dose-limiting toxic effects were observed on DL1. Two patients were enrolled in DL2 and experienced grade 3 GU toxicities, prompting de-escalation and expansion (n = 6) at the MTD (DL1). The most common toxicities observed were grade ≥2 GU toxicities, with only a single grade 2 GI toxicity and no grade ≥3 GI toxicities. One patient experienced biochemical failure (prostate-specific antigen nadir + 2.0) at 33 months. CONCLUSIONS: The MTD for focal salvage SBRT for isolated intraprostatic radiorecurrence was 40 Gy in 5 fractions, producing a 100% 24-month biochemical progression free survival, with 1 poststudy failure at 33 months. The most frequent clinically significant toxicity was late grade ≥2 GU toxicity.


Subject(s)
Prostatic Neoplasms , Radiosurgery , Male , Humans , Radiosurgery/adverse effects , Radiosurgery/methods , Prostatic Neoplasms/surgery , Urogenital System/radiation effects , Prostate-Specific Antigen , Magnetic Resonance Imaging , Salvage Therapy/methods
7.
Adv Radiat Oncol ; 7(5): 100902, 2022.
Article in English | MEDLINE | ID: mdl-35847548

ABSTRACT

Purpose: Optimal management of patients with prostate cancer (PCa) to achieve bowel and bladder reproducibility for radiation therapy (RT) and the appropriate planning target volume (PTV) expansions for use with modern image guidance is uncertain. We surveyed American Society of Radiation Oncology radiation oncologists to ascertain practice patterns for definitive PCa RT with respect to patient instructions and set up, daily image guidance, and subsequent PTV expansions. Methods and Materials: A pattern of practice survey was sent to American Society of Radiation Oncology radiation oncologists who self-identified as specializing in PCa. Respondents identified the fractionation regimens routinely used, and their practices regarding diet, bowel, and bladder instructions for patients with PCa before RT simulation and throughout treatment. Questions regarding PTV margins, daily set up practices, and use of image guidance were included. Results: Of 190 respondents, 158 reported using conventional fractionation (CFx), 49 moderate hypofractionation (MHFx), and 61 stereotactic body radiation therapy (SBRT). Diet modifications during RT were advised by 84% of respondents, treatment with full bladder by 96%, and bowel instructions by 78%. Prescription of bowel medication was higher for respondents using SBRT (95.1%) versus those using CFx/MHFx (55.1%; 34.7%). The most common implantable device reported was fiducial markers, with increased use in SBRT (86.0%; 68.9%) versus CFx/MHFx. Cone beam computed tomography was the most common daily imaging technique across fractionation regimens. SBRT showed correlation between PTV margin expansions, fiducial marker use, and image guidance. Conclusions: Survey results indicate heterogeneity in treatment modality, dose, patient instructions, and PTV expansions used by radiation oncologists in the treatment of patients with PCa. Further investigation to define appropriate patient instructions on bowel preparation to maximize target reproducibility in PCa is needed, as is continued guidance on evidence-based approaches for image guidance and PTV margin selection.

8.
Adv Radiat Oncol ; 7(6): 101024, 2022.
Article in English | MEDLINE | ID: mdl-36420197

ABSTRACT

Purpose: This phase 1 trial aimed to identify the maximally tolerated hypofractionated dose schedule for postoperative radiation therapy (PORT) after radical prostatectomy. Secondary objectives included biochemical control and quality of life (QoL) measures. Methods and Materials: Patients were treated on 1 of 3 dose levels (DLs): 56.4 Gy in 20 fractions (DL1), 51.2 Gy in 15 fractions (DL2), and 44.2 Gy in 10 fractions (DL3). Treatment was delivered to the prostate bed without pelvic nodal irradiation. Dose escalation followed a standard 3 + 3 design with an expansion for 6 additional patients at the maximally tolerated hypofractionated dose schedule. Acute dose-limiting toxicity (DLT) was defined as grade 3 toxicity lasting >4 days within 21 days of PORT completion; late DLT was defined as grade 4 gastrointestinal (GI) or genitourinary (GU) toxicity. Results: Between January 2018 and August 2019, 15 patients underwent radiation treatment: 3 on DL1, 3 on DL2, and 9 on DL3. The median follow-up was 24 months. There were no DLTs, and the maximally tolerated hypofractionated dose schedule was identified as DL3. Two of the 15 patients (13.3%) experienced biochemical failure (prostate-specific antigen >0.1). Ten of 15 patients (67%) had grade 2+ acute toxicities, consisting of transient GI toxicities. Three patients experienced late grade 2+ GI toxicity, and 5 patients experienced late grade 2+ GU toxicity. Late grade 3 GU toxicity occurred in 2 patients. There were no grade 4+ acute or late toxicities. There were no significant differences in GI measures of QoL, however, there was an increase in GU symptoms and corresponding decrease in GU QoL between 12 and 24 months. Conclusions: The maximum tolerated hypofractionated dose schedule for hypofractionated PORT to the prostate bed was determined to be 44.2 Gy in 10 daily fractions. The most frequent clinically significant toxicities were late grade 2+ GU toxicities, which corresponded to a worsening of late GU QoL.

9.
J Appl Clin Med Phys ; 12(4): 3589, 2011 Nov 15.
Article in English | MEDLINE | ID: mdl-22089016

ABSTRACT

Current estimation of radiation dose from computed tomography (CT) scans on patients has relied on the measurement of Computed Tomography Dose Index (CTDI) in standard cylindrical phantoms, and calculations based on mathematical representations of "standard man". Radiation dose to both adult and pediatric patients from a CT scan has been a concern, as noted in recent reports. The purpose of this study was to investigate the feasibility of adapting a radiation treatment planning system (RTPS) to provide patient-specific CT dosimetry. A radiation treatment planning system was modified to calculate patient-specific CT dose distributions, which can be represented by dose at specific points within an organ of interest, as well as organ dose-volumes (after image segmentation) for a GE Light Speed Ultra Plus CT scanner. The RTPS calculation algorithm is based on a semi-empirical, measured correction-based algorithm, which has been well established in the radiotherapy community. Digital representations of the physical phantoms (virtual phantom) were acquired with the GE CT scanner in axial mode. Thermoluminescent dosimeter (TLDs) measurements in pediatric anthropomorphic phantoms were utilized to validate the dose at specific points within organs of interest relative to RTPS calculations and Monte Carlo simulations of the same virtual phantoms (digital representation). Congruence of the calculated and measured point doses for the same physical anthropomorphic phantom geometry was used to verify the feasibility of the method. The RTPS algorithm can be extended to calculate the organ dose by calculating a dose distribution point-by-point for a designated volume. Electron Gamma Shower (EGSnrc) codes for radiation transport calculations developed by National Research Council of Canada (NRCC) were utilized to perform the Monte Carlo (MC) simulation. In general, the RTPS and MC dose calculations are within 10% of the TLD measurements for the infant and child chest scans. With respect to the dose comparisons for the head, the RTPS dose calculations are slightly higher (10%-20%) than the TLD measurements, while the MC results were within 10% of the TLD measurements. The advantage of the algebraic dose calculation engine of the RTPS is a substantially reduced computation time (minutes vs. days) relative to Monte Carlo calculations, as well as providing patient-specific dose estimation. It also provides the basis for a more elaborate reporting of dosimetric results, such as patient specific organ dose volumes after image segmentation.


Subject(s)
Thermoluminescent Dosimetry/methods , Tomography, X-Ray Computed/methods , Feasibility Studies , Humans , Phantoms, Imaging , Radiation Dosage , Tomography, X-Ray Computed/instrumentation
10.
Radiat Oncol ; 16(1): 32, 2021 Feb 10.
Article in English | MEDLINE | ID: mdl-33568190

ABSTRACT

BACKGROUND: Prostate Membrane Specific Antigen (PSMA) positron emission tomography (PET) and multiparametric MRI (mpMRI) have shown high accuracy in identifying recurrent lesions after definitive treatment in prostate cancer (PCa). In this study, we aimed to outline patterns of failure in a group of post-prostatectomy patients who received adjuvant or salvage radiation therapy (PORT) and subsequently experienced biochemical recurrence, using 18F-PSMA PET/CT and mpMRI. METHODS: PCa patients with biochemical failure post-prostatectomy, and no evident site of recurrence on conventional imaging, were enrolled on two prospective trials of first and second generation 18F-PSMA PET agents (18F-DCFBC and 18F-DCFPyL) in combination with MRI between October 2014 and December 2018. The primary aim of our study is to characterize these lesions with respect to their location relative to previous PORT field and received dose. RESULTS: A total of 34 participants underwent 18F-PSMA PET imaging for biochemical recurrence after radical prostatectomy and PORT, with 32/34 found to have 18F-PSMA avid lesions. On 18F-PSMA, 17/32 patients (53.1%) had metastatic disease, 8/32 (25.0%) patients had locoregional recurrences, and 7/32 (21.9%) had local failure in the prostate fossa. On further exploration, we noted 6/7 (86%) of prostate fossa recurrences were in-field and were encompassed by 100% isodose lines, receiving 64.8-72 Gy. One patient had marginal failure encompassed by the 49 Gy isodose. CONCLUSIONS: 18F-PSMA PET imaging demonstrates promise in identifying occult PCa recurrence after PORT. Although distant recurrence was the predominant pattern of failure, in-field recurrence was noted in approximately 1/5th of patients. This should be considered in tailoring radiotherapy practice after prostatectomy. Trial registration www.clinicaltrials.gov , NCT02190279 and NCT03181867. Registered July 12, 2014, https://clinicaltrials.gov/ct2/show/NCT02190279 and June 8 2017, https://clinicaltrials.gov/ct2/show/NCT03181867 .


Subject(s)
Molecular Imaging/methods , Neoplasm Recurrence, Local/pathology , Positron-Emission Tomography/methods , Prostatectomy/adverse effects , Prostatic Neoplasms/pathology , Radiotherapy/adverse effects , Aged , Antigens, Surface/metabolism , Combined Modality Therapy , Follow-Up Studies , Glutamate Carboxypeptidase II/metabolism , Humans , Male , Middle Aged , Neoplasm Recurrence, Local/diagnostic imaging , Neoplasm Recurrence, Local/metabolism , Neoplasm Recurrence, Local/therapy , Prospective Studies , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/metabolism , Prostatic Neoplasms/therapy , Retrospective Studies , Treatment Failure
11.
J Appl Clin Med Phys ; 12(1): 3306, 2010 Oct 07.
Article in English | MEDLINE | ID: mdl-21330976

ABSTRACT

The purpose was to evaluate and correct the co-registration of diagnostic PET/CT and MRI/MRI images for stereotactic radiosurgery (SRS) using 3D volumetric image registration (3DVIR). The 3DVIR utilizes the homogeneity of color distribution over a volumetric anatomical landmark as the registration criterion with submillimeter accuracy. Fifty-three PET/CT and MRI (T1, T2 and FLAIR) image sets of patients with brain lesions were acquired sequentially from a hybrid PET/CT or an MRI scanner with common diagnostic head holding devices. Twenty-five sets of head 18F-FDG-PET/CT images were scanned over a 10-minute interval and 14 whole-body sets were scanned over a 30-minute interval. Fourteen sets of MRI images were acquired, and each 3-modal image set (T1, T2 and FLAIR) was scanned in sequence at time 0, ~5 and ~20 minutes. The misalignments in these "co-registered" images were evaluated and corrected using the 3DVIR. Using the head immobilization devices commonly found in diagnostic PET/CT and MRI/MRI imaging, 80%-100% of these "co-registered" images were identified as misaligned. For PET/CT, the magnitude of misalignment was 0.4° ± 0.5° and 0.7 ± 0.4 mm for 10-minute scans, and 0.8° ± 1.2° and 2.7 ± 1.7 mm for 30-minute scans. For MRI/MRI, the magnitude was 0.2° ± 0.4° and 0.3 ± 0.2 mm for 5-minute scan intervals, and 1.1° ± 0.7° and 1.2 ± 1.4 mm for 20-minute intervals. Small, but significant, misalignment is present in the co-registered diagnostic PET/CT and MRI/MRI images and can be corrected in SRS treatment planning using the volumetric image registration for improved target localization within the clinical error tolerance.


Subject(s)
Head/diagnostic imaging , Magnetic Resonance Imaging/methods , Positron-Emission Tomography/methods , Radiosurgery/methods , Tomography, X-Ray Computed/methods , Artifacts , Fluorodeoxyglucose F18 , Humans , Imaging, Three-Dimensional , Motion , Phantoms, Imaging , Time Factors
12.
Med Phys ; 47(7): 3044-3053, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32277478

ABSTRACT

PURPOSE: Gliomas are the most common primary tumor of the brain and are classified into grades I-IV of the World Health Organization (WHO), based on their invasively histological appearance. Gliomas grading plays an important role to determine the treatment plan and prognosis prediction. In this study we propose two novel methods for automatic, non-invasively distinguishing low-grade (Grades II and III) glioma (LGG) and high-grade (grade IV) glioma (HGG) on conventional MRI images by using deep convolutional neural networks (CNNs). METHODS: All MRI images have been preprocessed first by rigid image registration and intensity inhomogeneity correction. Both proposed methods consist of two steps: (a) three-dimensional (3D) brain tumor segmentation based on a modification of the popular U-Net model; (b) tumor classification on segmented brain tumor. In the first method, the slice with largest area of tumor is determined and the state-of-the-art mask R-CNN model is employed for tumor grading. To improve the performance of the grading model, a two-dimensional (2D) data augmentation has been implemented to increase both the amount and the diversity of the training images. In the second method, denoted as 3DConvNet, a 3D volumetric CNNs is applied directly on bounding image regions of segmented tumor for classification, which can fully leverage the 3D spatial contextual information of volumetric image data. RESULTS: The proposed schemes were evaluated on The Cancer Imaging Archive (TCIA) low grade glioma (LGG) data, and the Multimodal Brain Tumor Image Segmentation (BraTS) Benchmark 2018 training datasets with fivefold cross validation. All data are divided into training, validation, and test sets. Based on biopsy-proven ground truth, the performance metrics of sensitivity, specificity, and accuracy are measured on the test sets. The results are 0.935 (sensitivity), 0.972 (specificity), and 0.963 (accuracy) for the 2D Mask R-CNN based method, and 0.947 (sensitivity), 0.968 (specificity), and 0.971 (accuracy) for the 3DConvNet method, respectively. In regard to efficiency, for 3D brain tumor segmentation, the program takes around ten and a half hours for training with 300 epochs on BraTS 2018 dataset and takes only around 50 s for testing of a typical image with a size of 160 × 216 × 176. For 2D Mask R-CNN based tumor grading, the program takes around 4 h for training with around 60 000 iterations, and around 1 s for testing of a 2D slice image with size of 128 × 128. For 3DConvNet based tumor grading, the program takes around 2 h for training with 10 000 iterations, and 0.25 s for testing of a 3D cropped image with size of 64 × 64 × 64, using a DELL PRECISION Tower T7910, with two NVIDIA Titan Xp GPUs. CONCLUSIONS: Two effective glioma grading methods on conventional MRI images using deep convolutional neural networks have been developed. Our methods are fully automated without manual specification of region-of-interests and selection of slices for model training, which are common in traditional machine learning based brain tumor grading methods. This methodology may play a crucial role in selecting effective treatment options and survival predictions without the need for surgical biopsy.


Subject(s)
Brain Neoplasms , Glioma , Brain Neoplasms/diagnostic imaging , Glioma/diagnostic imaging , Humans , Image Processing, Computer-Assisted , Machine Learning , Magnetic Resonance Imaging , Neural Networks, Computer
13.
Phys Med Biol ; 54(7): 1963-78, 2009 Apr 07.
Article in English | MEDLINE | ID: mdl-19265201

ABSTRACT

An external respiratory surrogate that not only highly correlates with but also quantitatively predicts internal tidal volume should be useful in guiding four-dimensional computed tomography (4DCT), as well as 4D radiation therapy (4DRT). A volumetric surrogate should have advantages over external fiducial point(s) for monitoring respiration-induced motion of the torso, which deforms in synchronization with a patient-specific breathing pattern. This study establishes a linear relationship between the external torso volume change (TVC) and lung air volume change (AVC) by validating a proposed volume conservation hypothesis (TVC = AVC) throughout the respiratory cycle using 4DCT and spirometry. Fourteen patients' torso 4DCT images and corresponding spirometric tidal volumes were acquired to examine this hypothesis. The 4DCT images were acquired using dual surrogates in ciné mode and amplitude-based binning in 12 respiratory stages, minimizing residual motion artifacts. Torso and lung volumes were calculated using threshold-based segmentation algorithms and volume changes were calculated relative to the full-exhalation stage. The TVC and AVC, as functions of respiratory stages, were compared, showing a high correlation (r = 0.992 +/- 0.005, p < 0.0001) as well as a linear relationship (slope = 1.027 +/- 0.061, R(2) = 0.980) without phase shift. The AVC was also compared to the spirometric tidal volumes, showing a similar linearity (slope = 1.030 +/- 0.092, R(2) = 0.947). In contrast, the thoracic and abdominal heights measured from 4DCT showed relatively low correlation (0.28 +/- 0.44 and 0.82 +/- 0.30, respectively) and location-dependent phase shifts. This novel approach establishes the foundation for developing an external volumetric respiratory surrogate.


Subject(s)
Body Size , Movement , Respiration , Tomography, X-Ray Computed/methods , Abdomen/anatomy & histology , Abdomen/physiology , Air , Gases , Gastrointestinal Tract/diagnostic imaging , Gastrointestinal Tract/metabolism , Humans , Linear Models , Lung/anatomy & histology , Lung/physiology , Pressure , Reproducibility of Results , Sensitivity and Specificity , Thorax/anatomy & histology , Thorax/physiology , Tidal Volume
14.
Phys Med Biol ; 54(13): 4113-30, 2009 Jul 07.
Article in English | MEDLINE | ID: mdl-19521009

ABSTRACT

An analytical approach to predict respiratory diaphragm motion should have advantages over a correlation-based method, which cannot adapt to breathing pattern changes without re-calibration for a changing correlation and/or linear coefficient. To quantitatively calculate the diaphragm motion, a new expandable 'piston' respiratory (EPR) model was proposed and tested using 4DCT torso images of 14 patients. The EPR model allows two orthogonal lung motions (with a few volumetric constraints): (1) the lungs expand (DeltaV(EXP)) with the same anterior height variation as the thoracic surface, and (2) the lungs extend (DeltaV(EXT)) with the same inferior distance as the volumetrically equivalent 'piston' diaphragm. A volume conservation rule (VCR) established previously (Li et al 2009 Phys. Med. Biol. 54 1963-78) was applied to link the external torso volume change (TVC) to internal lung volume change (LVC) via lung air volume change (AVC). As the diaphragm moves inferiorly, the vacant space above the diaphragm inside the rib cage should be filled by lung tissue with a volume equal to DeltaV(EXT) (=LVC-DeltaV(EXP)), while the volume of non-lung tissues in the thoracic cavity should conserve. It was found that DeltaV(EXP) accounted for 3-24% of the LVC in these patients. The volumetric shape of the rib cage, characterized by the variation of cavity volume per slice over the piston motion range, deviated from a hollow cylinder by -1.1% to 6.0%, and correction was made iteratively if the variation is >3%. The predictions based on the LVC and TVC (with a conversion factor) were compared with measured diaphragm displacements (averaged from six pivot points), showing excellent agreements (0.2 +/- 0.7 mm and 0.2 +/- 1.2 mm, respectively), which are within clinically acceptable tolerance. Assuming motion synchronization between the piston and points of interest along the diaphragm, point motion was estimated but at higher uncertainty ( approximately 10% +/- 4%). This analytical approach provides a patient-independent technique to calculate the patient-specific diaphragm motion, using the anatomical and respiratory volumetric constraints.


Subject(s)
Diaphragm/physiology , Imaging, Three-Dimensional/methods , Models, Biological , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Thoracic/methods , Respiratory Mechanics/physiology , Thorax/physiology , Algorithms , Computer Simulation , Diaphragm/diagnostic imaging , Humans , Organ Size/physiology , Tomography, X-Ray Computed/methods
15.
Med Phys ; 46(4): 1634-1647, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30723944

ABSTRACT

PURPOSE: For computed tomography (CT) systems in which noise is nonstationary, a local noise power spectrum (NPS) is often needed to characterize its noise property. We have previously developed a data-efficient radial NPS method to estimate the two-dimensional (2D) local NPS for filtered back projection (FBP)-reconstructed fan-beam CT utilizing the polar separability of CT NPS. In this work, we extend this method to estimate three-dimensional (3D) local NPS for feldkamp-davis-kress (FDK)-reconstructed cone-beam CT (CBCT) volumes. METHODS: Starting from the 2D polar separability, we analyze the CBCT geometry and FDK image reconstruction process to derive the 3D expression of the polar separability for CBCT local NPS. With the polar separability, the 3D local NPS of CBCT can be decomposed into a 2D radial NPS shape function and a one-dimensional (1D) angular amplitude function with certain geometrical transforms. The 2D radial NPS shape function is a global function characterizing the noise correlation structure, while the 1D angular amplitude function is a local function reflecting the varying local noise amplitudes. The 3D radial local NPS method is constructed from the polar separability. We evaluate the accuracy of the 3D radial local NPS method using simulated and real CBCT data by comparing the radial local NPS estimates to a reference local NPS in terms of normalized mean squared error (NMSE) and a task-based performance metric (lesion detectability). RESULTS: In both simulated and physical CBCT examples, a very small NMSE (<5%) was achieved by the radial local NPS method from as few as two scans, while for the traditional local NPS method, about 20 scans were needed to reach this accuracy. The results also showed that the detectability-based system performances computed using the local NPS estimated with the NPS method developed in this work from two scans closely reflected the actual system performance. CONCLUSIONS: The polar separability greatly reduces the data dimensionality of the 3D CBCT local NPS. The radial local NPS method developed based on this property is shown to be capable of estimating the 3D local NPS from only two CBCT scans with acceptable accuracy. The minimum data requirement indicates the potential utility of local NPS in CBCT applications even for clinical situations.


Subject(s)
Algorithms , Cone-Beam Computed Tomography/methods , Four-Dimensional Computed Tomography/methods , Image Processing, Computer-Assisted/methods , Lung Neoplasms/diagnostic imaging , Phantoms, Imaging , Humans , Signal-To-Noise Ratio
16.
J Appl Clin Med Phys ; 9(4): 17-36, 2008 Jul 09.
Article in English | MEDLINE | ID: mdl-19020479

ABSTRACT

Registration is critical for image-based treatment planning and image-guided treatment delivery. Although automatic registration is available, manual, visual-based image fusion using three orthogonal planar views (3P) is always employed clinically to verify and adjust an automatic registration result. However, the 3P fusion can be time consuming, observer dependent, as well as prone to errors, owing to the incomplete 3-dimensional (3D) volumetric image representations. It is also limited to single-pixel precision (the screen resolution). The 3D volumetric image registration (3DVIR) technique was developed to overcome these shortcomings. This technique introduces a 4th dimension in the registration criteria beyond the image volume, offering both visual and quantitative correlation of corresponding anatomic landmarks within the two registration images, facilitating a volumetric image alignment, and minimizing potential registration errors. The 3DVIR combines image classification in real-time to select and visualize a reliable anatomic landmark, rather than using all voxels for alignment. To determine the detection limit of the visual and quantitative 3DVIR criteria, slightly misaligned images were simulated and presented to eight clinical personnel for interpretation. Both of the criteria produce a detection limit of 0.1 mm and 0.1 degree. To determine the accuracy of the 3DVIR method, three imaging modalities (CT, MR and PET/CT) were used to acquire multiple phantom images with known spatial shifts. Lateral shifts were applied to these phantoms with displacement intervals of 5.0+/-0.1 mm. The accuracy of the 3DVIR technique was determined by comparing the image shifts determined through registration to the physical shifts made experimentally. The registration accuracy, together with precision, was found to be: 0.02+/-0.09 mm for CT/CT images, 0.03+/-0.07 mm for MR/MR images, and 0.03+/-0.35 mm for PET/CT images. This accuracy is consistent with the detection limit, suggesting an absence of detectable systematic error. This 3DVIR technique provides a superior alternative to the 3P fusion method for clinical applications.


Subject(s)
Magnetic Resonance Imaging/methods , Positron-Emission Tomography/methods , Tomography, X-Ray Computed/methods , Algorithms , Automation , Computer Simulation , Diagnostic Imaging/methods , Head/diagnostic imaging , Humans , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Models, Statistical , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted/methods , Reproducibility of Results
17.
Int J Radiat Oncol Biol Phys ; 68(5): 1402-9, 2007 Aug 01.
Article in English | MEDLINE | ID: mdl-17467921

ABSTRACT

PURPOSE: To report a new technique for the spinal component of craniospinal irradiation (CSI) in the supine position, to describe a verification procedure for this method, and to compare this technique with conventional plans. METHODS AND MATERIALS: Twelve patients were treated between 1998 and 2006 with CSI using a novel technique. Sixteen children were treated with a conventional field arrangement. All patients were followed for outcomes and toxicity. CSI was delivered using a posteroanterior (PA) intensity-modulated radiation therapy (IMRT) spinal field matched to conventional, opposed lateral cranial fields. Treatment plans were generated for each patient using the IMRT technique and a standard PA field technique. The resulting dosimetry was compared to determine target homogeneity, maximum dose to normal tissues, and total monitor units delivered. RESULTS: Evaluation of the spinal IMRT technique compared with a standard PA technique reveals a 7% reduction in the target volume receiving > or =110% of the prescribed dose and an 8% increase in the target volume receiving > or =95% of the prescribed dose. Although target homogeneity was improved, the maximum dose delivered in the paraspinal muscles was increased by approximately 8.5% with spinal IMRT compared to the PA technique. Follow-up evaluations revealed no unexpected toxicity associated with the IMRT technique. CONCLUSIONS: A new technique of spine IMRT is presented in combination with a quality assurance method. This method improves target dose uniformity compared to the conventional CSI technique. Longer follow-up will be required to determine any benefit with regard to toxicity and disease control.


Subject(s)
Brain Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/methods , Spinal Neoplasms/radiotherapy , Supine Position , Adolescent , Adult , Child , Child, Preschool , Female , Humans , Male , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/standards , Spinal Cord/radiation effects , Spine/radiation effects
18.
Med Phys ; 44(10): 5234-5243, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28736864

ABSTRACT

PURPOSE: Gliomas are rapidly progressive, neurologically devastating, largely fatal brain tumors. Magnetic resonance imaging (MRI) is a widely used technique employed in the diagnosis and management of gliomas in clinical practice. MRI is also the standard imaging modality used to delineate the brain tumor target as part of treatment planning for the administration of radiation therapy. Despite more than 20 yr of research and development, computational brain tumor segmentation in MRI images remains a challenging task. We are presenting a novel method of automatic image segmentation based on holistically nested neural networks that could be employed for brain tumor segmentation of MRI images. METHODS: Two preprocessing techniques were applied to MRI images. The N4ITK method was employed for correction of bias field distortion. A novel landmark-based intensity normalization method was developed so that tissue types have a similar intensity scale in images of different subjects for the same MRI protocol. The holistically nested neural networks (HNN), which extend from the convolutional neural networks (CNN) with a deep supervision through an additional weighted-fusion output layer, was trained to learn the multiscale and multilevel hierarchical appearance representation of the brain tumor in MRI images and was subsequently applied to produce a prediction map of the brain tumor on test images. Finally, the brain tumor was obtained through an optimum thresholding on the prediction map. RESULTS: The proposed method was evaluated on both the Multimodal Brain Tumor Image Segmentation (BRATS) Benchmark 2013 training datasets, and clinical data from our institute. A dice similarity coefficient (DSC) and sensitivity of 0.78 and 0.81 were achieved on 20 BRATS 2013 training datasets with high-grade gliomas (HGG), based on a two-fold cross-validation. The HNN model built on the BRATS 2013 training data was applied to ten clinical datasets with HGG from a locally developed database. DSC and sensitivity of 0.83 and 0.85 were achieved. A quantitative comparison indicated that the proposed method outperforms the popular fully convolutional network (FCN) method. In terms of efficiency, the proposed method took around 10 h for training with 50,000 iterations, and approximately 30 s for testing of a typical MRI image in the BRATS 2013 dataset with a size of 160 × 216 × 176, using a DELL PRECISION workstation T7400, with an NVIDIA Tesla K20c GPU. CONCLUSIONS: An effective brain tumor segmentation method for MRI images based on a HNN has been developed. The high level of accuracy and efficiency make this method practical in brain tumor segmentation. It may play a crucial role in both brain tumor diagnostic analysis and in the treatment planning of radiation therapy.


Subject(s)
Brain Neoplasms/diagnostic imaging , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging , Neural Networks, Computer , Glioma/diagnostic imaging , Humans
20.
Radiat Oncol ; 12(1): 191, 2017 Nov 29.
Article in English | MEDLINE | ID: mdl-29187219

ABSTRACT

PURPOSE/OBJECTIVES: Despite mounting evidence for the use of re-irradiation (re-RT) in recurrent high grade glioma, optimal patient selection criteria for re-RT remain unknown. We present a novel scoring system based on radiobiology principles including target independent factors, the likelihood of target control, and the anticipated organ at risk (OAR) toxicity to allow for proper patient selection in the setting of recurrent glioma. MATERIALS/METHODS: Thirty one patients with recurrent glioma who received re-RT (2008-2016) at NCI - NIH were included in the analysis. A novel scoring system for overall survival (OS) and progression free survival (PFS) was designed to include:1) target independent factors (age, KPS (Karnofsky Performance Status), histology, presence of symptoms), 2) target control, and 3) OAR toxicity risk. Normal tissue complication probability (NTCP) calculations were performed using the Lyman model. Kaplan-Meier analysis was performed for overall survival (OS) and progression free survival (PFS) for comparison amongst variables. RESULTS: No patient, including those who received dose to OAR above the published tolerance dose, experienced any treatment related grade 3-5 toxicity with a median PFS and OS from re-RT of 4 months (0.5-103) and 6 months (0.7-103) respectively. Based on cumulative maximum doses the average NTCP was 25% (0-99%) for the chiasm, 21% (0-99%) for the right optic nerve, 6% (0-92%) for the left optic nerve, and 59% (0-100%) for the brainstem. The independent factor and target control scores were each statistically significant for OS and the combination of independent factors plus target control was also significant for both OS (p = 0.02) and PFS (p = 0.006). The anticipated toxicity risk score was not statistically significant. CONCLUSION: Our scoring system may represent a novel approach to patient selection for re-RT in recurrent high grade glioma. Further validation in larger patient cohorts including compilation of doses to tumor and OAR may help refine this further for inclusion into clinical trials and general practice.


Subject(s)
Brain Neoplasms/pathology , Glioma/pathology , Neoplasm Recurrence, Local/pathology , Organs at Risk/radiation effects , Re-Irradiation/mortality , Adolescent , Adult , Aged , Brain Neoplasms/radiotherapy , Female , Glioma/radiotherapy , Humans , Karnofsky Performance Status , Male , Middle Aged , Neoplasm Recurrence, Local/radiotherapy , Prognosis , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/methods , Survival Rate , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL