Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters

Database
Language
Publication year range
1.
Heart Rhythm ; 21(2): 153-160, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37879547

ABSTRACT

BACKGROUND: Cardiac pacemaker implantation after orthotopic heart transplantation declined dramatically after development of the bicaval anastomosis technique. However, much less is known about the rate, indications, and predictors of device implantation procedures with the current surgical technique. OBJECTIVE: The purpose of this study was to evaluate the indications, patient characteristics, incidence, and survival related to cardiac implantable electronic device (CIED) implantation after heart transplantation. METHODS: This was a single-center study of 399 consecutive adult recipients of orthotopic heart transplants with bicaval anastomosis from 1991 to 2017. The primary end point was freedom from pacemaker or implantable cardioverter-defibrillator (ICD) implantation, and the secondary end point was all-cause mortality. RESULTS: At the time of transplantation, the mean age of recipients was 50 ± 12 years and that of donors 31 ± 12 years. CIEDs were implanted in 8% of recipients (n = 31): 11 pacemakers (35%) for sinus node dysfunction, 17 (55%) for high-grade heart block, and 3 ICDs (10%) for the primary prevention of sudden cardiac death. Early CIED implantation (<30 days) was rare and absent for sinus node dysfunction. The risk for CIED implantation increased progressively during follow-up (0-30 years; median 11 years), with low-, moderate-, and high-risk periods between 0 and 10, between 10 and 20, and between 20 and 30 years, respectively. Recipients receiving CIEDs survived longer after transplantation (21 years vs 13 years; P < .01). Recipients receiving pacemakers for heart block were more likely to receive older donor hearts at the time of transplantation. CONCLUSION: The risk of pacemaker implantation increases progressively, while ICD implantation is rare. Donor age is the predominant risk factor for subsequent heart block. Early sinus node dysfunction requiring permanent pacing is rare.


Subject(s)
Defibrillators, Implantable , Heart Transplantation , Pacemaker, Artificial , Adult , Humans , Middle Aged , Heart Transplantation/adverse effects , Follow-Up Studies , Sick Sinus Syndrome , Tissue Donors , Pacemaker, Artificial/adverse effects , Defibrillators, Implantable/adverse effects , Arrhythmias, Cardiac/etiology
SELECTION OF CITATIONS
SEARCH DETAIL