Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 47
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Monaldi Arch Chest Dis ; 94(1)2023 Apr 19.
Article in English | MEDLINE | ID: mdl-37074089

ABSTRACT

This study sought to compare the morbidity and mortality of redo aortic valve replacement (redo-AVR) versus valve-in-valve trans-catheter aortic valve implantation (valve-in-valve TAVI) for patients with a failing bioprosthetic valve. A multicenter UK retrospective study of redo-AVR or valve-in-valve TAVI for patients referred for redo aortic valve intervention due to a degenerated aortic bioprosthesis. Propensity score matching was performed for confounding factors. From July 2005 to April 2021, 911 patients underwent redo-AVR and 411 patients underwent valve-in-valve TAVI. There were 125 pairs for analysis after propensity score matching. The mean age was 75.2±8.5 years. In-hospital mortality was 7.2% (n=9) for redo-AVR versus 0 for valve-in-valve TAVI, p=0.002. Surgical patients suffered more post-operative complications, including intra-aortic balloon pump support (p=0.02), early re-operation (p<0.001), arrhythmias (p<0.001), respiratory and neurological complications (p=0.02 and p=0.03) and multi-organ failure (p=0.01). The valve-in-valve TAVI group had a shorter intensive care unit and hospital stay (p<0.001 for both). However, moderate aortic regurgitation at discharge and higher post-procedural gradients were more common after valve-in-valve TAVI (p<0.001 for both). Survival probabilities in patients who were successfully discharged from the hospital were similar after valve-in-valve TAVI and redo-AVR over the 6-year follow-up (log-rank p=0.26). In elderly patients with a degenerated aortic bioprosthesis, valve-in-valve TAVI provides better early outcomes as opposed to redo-AVR, although there was no difference in mid-term survival in patients successfully discharged from the hospital.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Aged , Aged, 80 and over , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Retrospective Studies , Aortic Valve Stenosis/surgery , Catheters , United Kingdom/epidemiology , Treatment Outcome , Risk Factors , Bioprosthesis/adverse effects
2.
Catheter Cardiovasc Interv ; 99(4): 1172-1180, 2022 03.
Article in English | MEDLINE | ID: mdl-34792842

ABSTRACT

BACKGROUND: The ACURATE neo™ is a novel, second-generation self-expanding supra-annular transcatheter heart valve (THV). The objective of this multi-centre registry is to assess the safety, clinical utility, and impact of 'learning-curve-experience' (LCE) on transcatheter aortic valve replacement outcomes in the United Kingdom (UK) and Ireland. METHODS: We prospectively collected data from seven ACURATE neo™ THV implanting centres (n = 484) between February 2016 and November 2020. We compared mortality rates and outcomes in the LCE group (n = 120) compared to next successive 120 cases. RESULTS: The mean age of the cohort was 81.9(SD: 6.1) years and the majority were in the moderate risk category (EuroSCORE-II):3.3(SD: 3). The 97.5% of cases were performed under local anesthetic. The valve was successfully deployed in 98.8% of cases. The survival rate at 30 days was 97.9%. The incidence of stroke was 2.5%. Life threatening bleeding occurred in 0.6% of cases and vascular access complications occurred in 21 (4.3%) patients. Implantation-related conduction abnormalities occurred in 8.3% but only 5.6% required a PPM. The successful valve deployment occurred in 96% of the patients in the LCE group compared to 100% in the other group (p = 0.04; OR-2[CI 1.7-2.3]). The mortality rates at 30 days (1.7% vs. 1.7%) and 1 year (1.9% vs. 2.7%) were comparable between the two groups. CONCLUSIONS: This study represents the largest published UK and Ireland real-world experience of the ACURATE neo™ valve. The procedural success rates and safety outcomes were excellent and endorse its utility in clinical practice. The LCE appears to have an impact on the successful valve deployment but without translating into short-term or long-term outcomes.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Humans , Ireland , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , United Kingdom
3.
Catheter Cardiovasc Interv ; 99(2): 305-313, 2022 02.
Article in English | MEDLINE | ID: mdl-33942478

ABSTRACT

OBJECTIVES: To describe outcomes following percutaneous coronary intervention (PCI) in patients who would usually have undergone coronary artery bypass grafting (CABG). BACKGROUND: In the United Kingdom, cardiac surgery for coronary artery disease (CAD) was dramatically reduced during the first wave of the COVID-19 pandemic. Many patients with "surgical disease" instead underwent PCI. METHODS: Between 1 March 2020 and 31 July 2020, 215 patients with recognized "surgical" CAD who underwent PCI were enrolled in the prospective UK-ReVasc Registry (ReVR). 30-day major cardiovascular event outcomes were collected. Findings in ReVR patients were directly compared to reference PCI and isolated CABG pre-COVID-19 data from British Cardiovascular Intervention Society (BCIS) and National Cardiac Audit Programme (NCAP) databases. RESULTS: ReVR patients had higher incidence of diabetes (34.4% vs 26.4%, P = .008), multi-vessel disease with left main stem disease (51.4% vs 3.0%, P < .001) and left anterior descending artery involvement (94.8% vs 67.2%, P < .001) compared to BCIS data. SYNTAX Score in ReVR was high (mean 28.0). Increased use of transradial access (93.3% vs 88.6%, P = .03), intracoronary imaging (43.6% vs 14.4%, P < .001) and calcium modification (23.6% vs 3.5%, P < .001) was observed. No difference in in-hospital mortality was demonstrated compared to PCI and CABG data (ReVR 1.4% vs BCIS 0.7%, P = .19; vs NCAP 1.0%, P = .48). Inpatient stay was half compared to CABG (3.0 vs 6.0 days). Low-event rates in ReVR were maintained to 30-day follow-up. CONCLUSIONS: PCI undertaken using contemporary techniques produces excellent short-term results in patients who would be otherwise CABG candidates. Longer-term follow-up is essential to determine whether these outcomes are maintained over time.


Subject(s)
COVID-19 , Coronary Artery Disease , Percutaneous Coronary Intervention , Coronary Artery Bypass , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Hirudins , Humans , Pandemics , Prospective Studies , Recombinant Proteins , Registries , SARS-CoV-2 , Treatment Outcome
4.
Am Heart J ; 242: 24-32, 2021 12.
Article in English | MEDLINE | ID: mdl-34450050

ABSTRACT

BACKGROUND: Obesity is a real public health problem and is of growing concern. People are resorting to surgical or endoscopic means to fight against overweight and obesity. In recent years, there has been a marked increase in the use of these means and in particular the insertion of a gastric balloon which seems to present less risk than surgical methods. Renal complications from intragastric balloon placement are extremely rare. We report here the case of compression of the left renal vein revealed by lumbar pain and hematuria in an overweight 39-year-old woman who benefited from the balloon gastric placement one month before symptoms. The scanner made the diagnosis and showed a good evolution after the withdrawal of the balloon. METHODS: This was a prespecified and retrospective analysis of all consecutive patients who underwent FFR assessment for intermediate coronary lesions between January 2014 and December 2015. The primary endpoint was defined as the 1-year composite of cardiac death, vessel-related myocardial infarction, and clinically-driven target vessel revascularization. RESULTS: In 1554 lesions (23% in women), FFR was lower in men [0.83 ±0.09 vs 0.85 ±0.08, P = .004] driven by LAD values (for LAD P < .001, LCx or RCA P> .40). In proximal lesions (PLs), FFR was lower in men [0.83 ±0.10 vs 0.85 ±0.08, P = .004] with comparable values in non-PLs [0.84 ±0.09 vs 0.85 ±0.08, P = .36]. In PLs, the primary endpoint was higher in women [HR(adjusted) 3.18 (1.08-9.37), P = .035] with comparable outcomes in non-PLs (P = .032 for interaction). In deferred lesions, the primary endpoint was higher in women [HR(adjusted) 2.73 (1.10-6.74), P = .03] with no differences in revascularized lesions across sex (P = .02 for interaction). Results were consistent when using propensity score matching analysis. CONCLUSIONS: There is a sex-based difference in FFR, particularly in stenoses subtending large myocardium, and more evident in deferred lesions.


Subject(s)
Fractional Flow Reserve, Myocardial , Gastric Balloon , Overweight , Adult , Female , Gastric Balloon/adverse effects , Humans , Male , Overweight/surgery , Retrospective Studies , Sex Factors , Treatment Outcome
5.
Catheter Cardiovasc Interv ; 95(7): 1340-1346, 2020 06 01.
Article in English | MEDLINE | ID: mdl-31713325

ABSTRACT

OBJECTIVES: The United Kingdom and Ireland Implanters' registry is a multicenter registry which reports on real-world experience with new transcatheter heart valves. BACKGROUND: The Evolut PRO (Medtronic, Minneapolis, MN) transcatheter aortic valve is a self-expanding transcatheter aortic valve with an outer pericardial wrap, designed to minimize paravalvular regurgitation. METHODS: Between July 2017 and December 2018, clinical, procedural, and 30-day outcome data were prospectively collected from all patients receiving the Evolut PRO valve across nine participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2 (VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 317 patients underwent implantation. Mean age was 81.8 ± 6.4 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.5 ± 1.8%. Iliofemoral access was used in 99.1% of patients. Device success was 91.2%. Mean gradient was 7.6 ± 4.7 mmHg and effective orifice area 1.9 ± 0.7 cm2 . The incidence of moderate paravalvular regurgitation was 1.7% and there was no severe paravalvular regurgitation. A new permanent pacemaker was implanted in 17.8% of patients without a pacemaker at baseline. Early safety was demonstrated in 92.7%. At 30 days, all-cause mortality was 0.6%, stroke 3.8%, and major vascular complication 2.8%. CONCLUSIONS: Real-world experience of the Evolut PRO transcatheter aortic valve demonstrated favorable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis , Pericardium/transplantation , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Humans , Ireland , Male , Prosthesis Design , Registries , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United Kingdom
6.
Cardiovasc Drugs Ther ; 34(5): 659-662, 2020 10.
Article in English | MEDLINE | ID: mdl-32488426

ABSTRACT

BACKGROUND: The prognostic role of procedural complexity when discontinuing aspirin in patients on oral anticoagulation undergoing percutaneous coronary intervention (PCI) has never been studied. METHODS: Ischaemic events were compared in 256 consecutive patients according to procedural complexity and aspirin on discharge. PCI complexity was defined according to the high-risk features for ischaemic events in the current guidelines RESULTS: Forty percent patients had stable presentation. In patients with complex PCI, ischaemic events were significantly higher when discharged without aspirin (adjusted HR 3.66, (95% CI 1.07 to 12.47), P = 0.038). This was driven from both target vessel failure and de-novo coronary lesions. Ischaemic events were comparable between patients with complex PCI on aspirin and those who underwent non-complex PCI. CONCLUSIONS: Procedural complexity in patients with indication for oral anticoagulation undergoing PCI should be factored in when deciding optimal antithrombotic therapies. Aspirin discontinuation in patients with high-risk PCI features should be discouraged.


Subject(s)
Anticoagulants/administration & dosage , Aspirin/administration & dosage , Fibrinolytic Agents/administration & dosage , Myocardial Ischemia/therapy , Percutaneous Coronary Intervention , Thrombosis/prevention & control , Administration, Oral , Aged , Aged, 80 and over , Anticoagulants/adverse effects , Aspirin/adverse effects , Drug Administration Schedule , Female , Fibrinolytic Agents/adverse effects , Humans , Male , Myocardial Ischemia/diagnosis , Myocardial Ischemia/mortality , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Risk Factors , Thrombosis/etiology , Thrombosis/mortality , Time Factors , Treatment Outcome
7.
Catheter Cardiovasc Interv ; 93(4): 751-757, 2019 03 01.
Article in English | MEDLINE | ID: mdl-30394657

ABSTRACT

OBJECTIVES: The UK & Ireland Implanters' registry is a multicenter registry which reports on real-world experience with novel transcatheter heart valves. BACKGROUND: The 34 mm Evolut R transcatheter aortic valve is a self-expanding and fully recapturable transcatheter aortic valve, designed to treat patients with a large aortic annulus. METHODS: Between January 2017 and April 2018, clinical, procedural and 30-day outcome data were prospectively collected from all patients receiving the 34 mm Evolut R valve across 17 participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2(VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 217 patients underwent attempted implant. Mean age was 79.5 ± 8.8 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.2% ± 3.4%. Iliofemoral access was used in 91.2% of patients. Device success was 79.7%. Mean gradient was 7.0 ± 4.6 mmHg and effective orifice area 2.0 ± 0.6 cm2 . Paravalvular regurgitation was more than mild in 7.2%. A new permanent pacemaker was implanted in 15.7%. Early safety was demonstrated in 91.2%. At 30 days, all-cause mortality was 3.2%, stroke 3.7%, and major vascular complication 2.3%. CONCLUSIONS: Real-world experience of the 34 mm Evolut R transcatheter aortic valve demonstrated acceptable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Hemodynamics , Humans , Ireland , Male , Postoperative Complications/mortality , Postoperative Complications/therapy , Prosthesis Design , Registries , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , United Kingdom
8.
J Card Surg ; 34(4): 161-166, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30803038

ABSTRACT

With a rise in the aging population, mitral annular calcification is increasingly encountered with an incidence of 10% in over 70 years old. This with increasing patient comorbidities presents a technical challenge due to the risk of atrioventricular disruption which is associated with high operative mortality of up to 75%. We describe two cases of severe mitral disease with marked annular calcification successfully treated with a balloon expandable transcatheter valve which was deployed on cardiopulmonary bypass via a trans-atrial approach.


Subject(s)
Calcinosis/surgery , Cardiac Catheterization/methods , Heart Valve Prolapse , Heart Valve Prosthesis Implantation/methods , Mitral Valve Stenosis/surgery , Mitral Valve/surgery , Aged , Calcinosis/complications , Cardiopulmonary Bypass , Female , Humans , Mitral Valve Stenosis/etiology , Severity of Illness Index , Treatment Outcome
9.
J Soc Cardiovasc Angiogr Interv ; 3(7): 102017, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39132006

ABSTRACT

Background: Chronic total occlusion (CTO) remains the most complex anatomical subset of lesions in percutaneous coronary intervention (PCI), often requiring advanced techniques and technologies, including the use of microcatheters. Methods: The BIOMICS study is a premarket first-in-human prospective, multicenter, open-label, single-arm trial investigating the safety and efficacy of a novel coronary microcatheter (BioMC, Biosensors International) in 100 patients with symptoms of ischemia undergoing elective CTO-PCI. The primary efficacy end point of the study was device success defined according to the CTO-ARC (Chronic Total Occlusion Academic Research Consortium) criteria namely the ability of the microcatheter to successfully facilitate placement of a guide wire beyond the occluded coronary segment. The primary safety end point was the incidence of in-hospital cardiac death or myocardial infarction at hospital discharge. Results: Hundred patients were recruited between March 2022 and January 2023. The primary efficacy end point was achieved in 75% of patients (95% CI, 65.3%-83.1%; P < .0001 for superiority compared to the prespecified performance goal of 54%). The primary safety end point of in-hospital cardiac death or myocardial infarction was observed in 2% of the patients. There were no study device-related coronary perforations or device failures. Conclusions: The use of a novel coronary microcatheter during CTO-PCI was associated with a high device success and an excellent safety profile.

10.
J Invasive Cardiol ; 2024 Mar 06.
Article in English | MEDLINE | ID: mdl-38471155

ABSTRACT

OBJECTIVES: Cardiac surgery for coronary artery disease was dramatically reduced during the first wave of the COVID-19 pandemic. Many patients with disease ordinarily treated with coronary artery bypass grafting (CABG) instead underwent percutaneous coronary intervention (PCI). We sought to describe 12-month outcomes following PCI in patients who would typically have undergone CABG. METHODS: Between March 1 and July 31, 2020, patients who received revascularization with PCI when CABG would have been the primary choice of revascularization were enrolled in the prospective, multicenter UK-ReVasc Registry. We evaluated the following major adverse cardiovascular events at 12 months: all-cause mortality, myocardial infarction, repeat revascularization, stroke, major bleeding, and stent thrombosis. RESULTS: A total of 215 patients were enrolled across 45 PCI centers in the United Kingdom. Twelve-month follow up data were obtained for 97% of the cases. There were 9 deaths (4.3%), 5 myocardial infarctions (2.4%), 12 repeat revascularizations (5.7%), 1 stroke (0.5%), 3 major bleeds (1.4%), and no cases of stent thrombosis. No difference in the primary endpoint was observed between patients who received complete vs incomplete revascularization (residual SYNTAX score £ 8 vs > 8) (P = .22). CONCLUSIONS: In patients with patterns of coronary disease in whom CABG would have been the primary therapeutic choice outside of the pandemic, PCI was associated with acceptable outcomes at 12 months of follow-up. Contemporary randomized trials that compare PCI to CABG in such patient cohorts may be warranted.

11.
Interv Cardiol ; 17: e09, 2022 Jan.
Article in English | MEDLINE | ID: mdl-35891630

ABSTRACT

Spontaneous coronary artery dissection (SCAD) is a less common cause of acute coronary syndrome. Pregnancy-related SCAD is uncommon, but often presents with a more severe phenotype. This report describes a 30-year-old woman with an anterior ST elevation MI, presenting 1 day postpartum. Left main stem (LMS) SCAD with extensive intramural haematoma (IMH) and resultant LMS occlusion was confirmed by angiography and intravascular imaging. Given the extent of disease, the patient underwent emergency cardiac surgery. Coronary flow was initially improved by decompressing the IMH using cutting balloons. The coronary wires were successfully left in situ during transfer in an effort to both maintain flow and allow the surgeon to identify true LMS. Ideally, SCAD can be managed conservatively given the risk of intervention worsening IMH, and hence myocardial ischaemia/MI. However, emergency revascularisation is indicated in cases of persistent ischaemia. This case demonstrates percutaneous therapies to bridge towards and help with subsequent surgical revascularisation.

12.
J Invasive Cardiol ; 34(5): E380-E389, 2022 05.
Article in English | MEDLINE | ID: mdl-35394450

ABSTRACT

OBJECTIVES: To define the optimal implantation of the Sapien 3 (Edwards Lifesciences) transcatheter heart valve (THV), this study systematically analyzed the predeployment fluoroscopic THV position and correlated this to clinical outcomes. METHODS: This was an observational study of 279 patients treated with the Sapien 3 THV. Fluoroscopic imaging was used to categorize patients into low (n = 147), intermediate (n = 86), and high (n = 46) implantation zones. These zones were based on the relationship of the balloon marker and radiolucent line of the valve frame (line of lucency) to the annular plane at deployment. The primary outcome was the rate of permanent pacemaker implantation (PPI) at 30 days. The secondary outcomes were the rates of new left bundle-branch block (LBBB) in-hospital and all-cause mortality at 1 year. RESULTS: In the high, intermediate, and low groups, 30-day PPI rates were 4.3%, 8.1%, and 8.8% (P=.62); in-hospital LBBB rates were 10.9%, 26.7%, and 32.0% (P=.02); and all-cause mortality rates at 1 year were 3.1%, 7.3%, and 12.5% (P=.14), respectively. No differences were observed with respect to procedural success/complications or THV performance between the groups. CONCLUSION: This study demonstrates fewer conduction abnormalities for Sapien 3 valves positioned within a higher zone defined fluoroscopically by the line of lucency and balloon marker.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Bundle-Branch Block/etiology , Heart Valve Prosthesis/adverse effects , Humans , Transcatheter Aortic Valve Replacement/adverse effects
13.
J Electrocardiol ; 44(4): 432-8, 2011.
Article in English | MEDLINE | ID: mdl-21529821

ABSTRACT

UNLABELLED: Of patients who present with ischemic-type chest pain and a negative cardiac troponin T (cTnT) at first medical contact, there are patients at a very early stage of infarction. The aim of this research was to assess heart fatty acid-binding protein (H-FABP), a novel marker of myocyte necrosis, in combination with the 80-lead body surface potential map (BSPM) in the early diagnosis of acute myocardial infarction (AMI). METHODS: In this prospective study, consecutive patients presenting with acute ischemic-type chest pain between 2003 and 2006 were enrolled. At first medical contact, blood was sampled for cTnT and H-FABP; in addition, a 12-lead electrocardiogram (ECG) and BSPM were recorded. A second cTnT was sampled 12 hours or more after presentation. Peak cTnT 0.03 µg/L or higher diagnosed AMI. Elevated H-FABP was 5 ng/mL or higher. A cardiologist blinded to both the clinical details and 12-lead ECG interpreted the BSPM. RESULTS: Enrolled were 407 patients (age 62 ± 13 years; 70% men). Of these 407, 180 had cTnT less than 0.03 µg/L at presentation. Acute myocardial infarction occurred in 52 (29%) of 180 patients. Of these 180 patients, 27 had ST-segment elevation (STE) on ECG, 104 had STE on BSPM (sensitivity, 88%; specificity, 55%), and 95 (53%) had H-FABP elevation. The proportion with elevated H-FABP was higher in the AMI group compared with non-AMI group (P < .001). Body surface potential map STE was significantly associated with H-FABP elevation (P < .001). Of those with initial cTnT less than 0.03 µg/L, the c-statistic for the receiver operating characteristic curve distinguishing AMI from non-AMI using H-FABP alone was 0.644 (95% confidence interval [CI], 0.521-0.771), using BSPM alone was 0.716 (95% CI, 0.638-0.793), and using the combination of BSPM and H-FABP was 0.812 (95% CI, 0.747-0.876; P < .001). CONCLUSION: In patients with acute ischemic-type chest pain who have a normal cTnT at presentation, the combination of H-FABP and BSPM at first assessment identifies those with early AMI (c-statistic, 0.812; P < .001), thus allowing earlier triage to reperfusion therapy and secondary prevention.


Subject(s)
Body Surface Potential Mapping/methods , Fatty Acid-Binding Proteins/blood , Myocardial Infarction/blood , Myocardial Infarction/diagnosis , Aged , Biomarkers/blood , Chi-Square Distribution , Early Diagnosis , Electrocardiography , Fatty Acid Binding Protein 3 , Female , Humans , Male , Middle Aged , Prospective Studies , ROC Curve , Time Factors , Troponin T/blood
14.
J Electrocardiol ; 44(4): 425-31, 2011.
Article in English | MEDLINE | ID: mdl-21704220

ABSTRACT

BACKGROUND: For the assessment of patients with chest pain, the 12-lead electrocardiogram (ECG) is the initial investigation. Major management decisions are based on the ECG findings, both for attempted coronary artery revascularization and risk stratification. The aim of this study was to determine if the current 6 precordial leads (V(1)-V(6)) are optimally located for the detection of ST-segment elevation in ST-segment elevation myocardial infarction (STEMI). METHODS: We analyzed 528 (38% anterior [200], 44% inferior [233], and 18% lateral [95]) patients with STEMI with both a 12-lead ECG and an 80-lead body surface map (BSM) ECG (Prime ECG, Heartscape Technologies, Bangor, Northern Ireland). Body surface map was recorded within 15 minutes of the 12-lead ECG during the acute event and before revascularization. ST-segment elevation of each lead on the BSM was compared with the corresponding 12-lead precordial leads (V(1)-V(6)) for anterior STEMI. In addition, for lateral STEMI, leads I and aVL of the BSM were also compared; and limb leads II, III, aVF of the BSM were compared with inferior unipolar BSM leads for inferior STEMI. Leads with the greatest mean ST-segment elevation were selected, and significance was determined by analysis of variance of the mean ST segment. RESULTS: For anterior STEMI, leads V(1), V(2), 32, 42, 51, and 57 had the greatest mean ST elevation. These leads are located in the same horizontal plane as that of V(1) and V(2). Lead 32 had a significantly greater mean ST elevation than the corresponding precordial lead V(3) (P = .012); and leads 42, 51, and 57 were also significantly greater than corresponding leads V(4), V(5), V(6), respectively (P < .001). Similar findings were also found for lateral STEMI. For inferior STEMI, the limb leads of the BSM (II, III, and aVF) had the greatest mean ST-segment elevation; and lead III was significantly superior to the inferior unipolar leads (7, 17, 27, 37, 47, 55, and 61) of the BSM (P < .001). CONCLUSION: Leads placed on a horizontal strip, in line with leads V(1) and V(2), provided the optimal placement for the diagnosis of anterior and lateral STEMI and appear superior to leads V(3), V(4), V(5), and V(6). This is of significant clinical interest, not only for ease and replication of lead placement but also may lead to increased recruitment of patients eligible for revascularization with none or borderline ST-segment elevation on the initial 12-lead ECG.


Subject(s)
Electrocardiography/instrumentation , Myocardial Infarction/diagnosis , Aged , Analysis of Variance , Body Surface Potential Mapping , Female , Humans , Male , Middle Aged , Myocardial Infarction/physiopathology , Retrospective Studies
15.
JTCVS Tech ; 10: 254-261, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34977731

ABSTRACT

BACKGROUND: Transcatheter mitral valve implantation (TMVI) for native mitral valve pathology with severe mitral annular calcification has emerged as an alternative treatment option to conventional mitral valve surgery. The objective of this study was to evaluate patients who were referred for TMVI with severe mitral annular calcification and their procedural outcomes. METHODS: Retrospective analysis of patients from 2017 to 2020 referred for TMVI was carried out. Demographic characteristic details; surgical strategy; perioperative complications; and hospital stay, including 30-day and 1-year mortality, were analyzed. RESULTS: Eleven patients were referred for consideration of TMVI. The 8 patients who underwent TMVI had a median age of 74 years (range, 57-80 years), the median Society of Thoracic Surgeons score was 4.6 (range, 2.4-10.9), and European System for Cardiac Operative Risk Evaluation II score was 5.2% (2%-10.1%). The median cardiopulmonary bypass time and crossclamp times were 170 minutes (range, 150-248 minutes) and 152 minutes (range, 118-214 minutes), respectively. The median hospital stay was 29 days (range, 2-40 days). Thirty-day in hospital mortality was 12%, whereas 1-year mortality was 25%. There was symptomatic improvement with downgrade of New York Heart Association functional class from III or IV to I or II. The 3 patients who were turned down had a median age of 73 years, median Society of Thoracic Surgeons score was 13.4, and median European System for Cardiac Operative Risk Evaluation II score was 5.72%. They were alive at 12 months follow-up from the date of surgical assessment; however, all with New York Heart Association functional class III or IV symptoms. CONCLUSIONS: We describe a series demonstrating the technical consideration and capability of transatrial TMVI to treat mitral annular calcification and native mitral valve disease. Our results are favorable when compared with TMVI global registry data for transseptal or transapical approach.

16.
Can J Cardiol ; 36(1): 112-118, 2020 01.
Article in English | MEDLINE | ID: mdl-31785992

ABSTRACT

BACKGROUND: Tools are needed to identify patients at increased risk after transcatheter aortic valve replacement (TAVR). Indexed stroke volume (SVi) is an echocardiographic measurement that is used for low-gradient aortic stenosis. We studied whether low SVi is a high-risk marker in patients with high-gradient aortic stenosis (HG-AS) and assessed the relationship between SVi and left ventricle (LV) systolic function in contributing to this risk. METHODS: A total of 816 consecutive patients who underwent TAVR were screened, and only patients with HG-AS were included. Low flow (LF) was defined as SVi ≤ 35 mL/m2. The primary endpoint was defined as a combination of all-cause mortality and readmission with heart failure at 1 year. RESULTS: Of the 476 patients with HG-AS, 215 (45%) had LF. They had higher N-terminal pro b-type natriuretic peptide (NTproBNP) (2565 [1037-5492] vs 1730 [818-3575], P = 0.006) and smaller indexed valve area (0.30 ± 0.10 vs 0.37 ± 0.10 cm2/m2, P < 0.001) when compared with normal flow patients. The primary endpoint was higher in LF patients (hazard ratio, 1.49; 95% confidence interval, 1.01-2.21; P = 0.045). There were no statistical differences in the individual components of death (13.0% vs 8.9%, P = 0.16) or heart failure (14.9% vs 10.1%, P = 0.12). When stratified according to LV function, low SVi was associated with future adverse events in patients with reduced function (hazard ratio, 3.37; 95% confidence interval, 1.26-8.98; P = 0.015) with comparable clinical outcomes in those with preserved function. LF was an independent predictor of adverse events in the reduced LV function subgroup. CONCLUSIONS: SVi can further characterize patients with HG-AS and may help to identify those who are at increased risk after TAVR.


Subject(s)
Aortic Valve Stenosis/physiopathology , Stroke Volume/physiology , Transcatheter Aortic Valve Replacement , Ventricular Function, Left/physiology , Aged, 80 and over , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Echocardiography , Female , Follow-Up Studies , Humans , Male , Prognosis , Retrospective Studies , Risk Factors , Severity of Illness Index , Systole
17.
J Am Heart Assoc ; 9(15): e016990, 2020 08 04.
Article in English | MEDLINE | ID: mdl-32715844

ABSTRACT

Background Despite the availability of guidelines for the performance of transcatheter aortic valve implantation (TAVI), current treatment pathways vary between countries and institutions, which impact on the mean duration of postprocedure hospitalization. Methods and Results This was a prospective, multicenter registry of 502 patients to validate the appropriateness of discharge timing after transfemoral TAVI, using prespecified risk criteria from FAST-TAVI (Feasibility and Safety of Early Discharge After Transfemoral [TF] Transcatheter Aortic Valve Implantation), based on hospital events within 1-year after discharge. The end point-a composite of all-cause mortality, vascular access-related complications, permanent pacemaker implantation, stroke, cardiac rehospitalization, kidney failure, and major bleeding-was reached in 27.0% of patients (95% CI, 23.3-31.2) within 1 year after intervention; 7.5% (95% CI, 5.5-10.2) had in-hospital complications before discharge and 19.6% (95% CI, 16.3-23.4) within 1 year after discharge. Overall mortality within 1 year after discharge was 7.3% and rates of cardiac rehospitalization 13.5%, permanent pacemaker implantation 4.2%, any stroke 1.8%, vascular-access-related complications 0.7%, life-threatening bleeding 0.7%, and kidney failure 0.4%. Composite events within 1 year after discharge were observed in 18.8% and 24.3% of patients with low risk of complications/early (≤3 days) discharge and high risk and discharged late (>3 days) (concordant discharge), respectively. Event rate in patients with discordant discharge was 14.3% with low risk but discharged late and increased to 50.0% in patients with high risk but discharged in ≤3 days. Conclusions The FAST-TAVI risk assessment provides a tool for appropriate, risk-based discharge that was validated with the 1-year event rate after transfemoral TAVI. Registration URL: https://www.ClinicalTrials.gov; Unique identifier: NCT02404467.


Subject(s)
Patient Discharge , Postoperative Complications/epidemiology , Registries , Transcatheter Aortic Valve Replacement/statistics & numerical data , Europe/epidemiology , Humans , Prospective Studies
18.
Eur Heart J ; 29(23): 2843-50, 2008 Dec.
Article in English | MEDLINE | ID: mdl-18682444

ABSTRACT

AIMS: To evaluate the role of novel biomarkers in early detection of acute myocardial infarction (MI) in patients admitted with acute chest pain. METHODS AND RESULTS: A prospective study of 664 patients presenting to two coronary care units with chest pain was conducted over 3 years from 2003. Patients were assessed on admission: clinical characteristics, ECG (electrocardiogram), renal function, cardiac troponin T (cTnT), heart fatty acid binding protein (H-FABP), glycogen phosphorylase-BB, NT-pro-brain natriuretic peptide, D-dimer, hsCRP (high sensitivity C-reactive protein), myeloperoxidase, matrix metalloproteinase-9, pregnancy associated plasma protein-A, soluble CD40 ligand. A > or = 12 h cTnT sample was also obtained. MI was defined as cTnT > or = 0.03 microg/L. In patients presenting <4 h of symptom onset, sensitivity of H-FABP for MI was significantly higher than admission cTnT (73 vs. 55%; P = 0.043). Specificity of H-FABP was 71%. None of the other biomarkers challenged cTnT. Combined use of H-FABP and cTnT (either one elevated initially) significantly improved the sensitivities of H-FABP or cTnT (85%; P < or = 0.004). This combined approach also improved the negative predictive value, negative likelihood ratio, and the risk ratio. CONCLUSION: Assessment of H-FABP within the first 4 h of symptoms is superior to cTnT for detection of MI, and is a useful additional biomarker for patients with acute chest pain.


Subject(s)
Angina, Unstable/diagnosis , Fatty Acid-Binding Proteins/metabolism , Myocardial Infarction/diagnosis , Natriuretic Peptide, Brain/metabolism , Troponin T/metabolism , Biomarkers/metabolism , Chest Pain/etiology , Electrocardiography , Epidemiologic Methods , Fatty Acid Binding Protein 3 , Female , Humans , Male , Middle Aged , Prognosis
19.
World J Cardiol ; 11(7): 189-194, 2019 Jul 26.
Article in English | MEDLINE | ID: mdl-31565194

ABSTRACT

BACKGROUND: High-speed rotational atherectomy (HSRA) is most commonly used to modify calcified coronary artery lesions to facilitate stent deployment and expansion. The use of HSRA as an emergency rescue technique to release a fractured micro-catheter has not been described. We report the use of HSRA in a case of a fracture trapped corsair tip that was impeding coronary flow causing a ST elevation myocardial infarct. CASE SUMMARY: A 79 years old male was scheduled for elective percutaneous coronary intervention (PCI) to his left anterior descending artery (LAD). Given its calcific nature, a decision was made for upfront rotablation. During procedural preparations, the tip of an employed micro-catheter was separated from the shaft resulting in obstructing coronary flow and ST-segment elevation. The consensus was for an attempt bail out PCI strategy. A rotafloppy wire was advanced to the distal LAD using a corsair micro-catheter which was placed proximal to the occlusion site. Modification of the mid LAD segment was performed, resulting in mobilising the corsair tip, and deflecting it to a small diagonal branch. Following serial predilation, the procedure was completed using two overlapping drug eluting stents, jailing the corsair tip in the diagonal branch. The patient made uneventful recovery and was clinically stable at one year follow up. CONCLUSION: HSRA may be offered as a bailed-out strategy to rescue fractured and jailed micro-catheter tip in high risk surgical cases.

20.
Cardiovasc Revasc Med ; 20(12): 1048-1052, 2019 Dec.
Article in English | MEDLINE | ID: mdl-30745059

ABSTRACT

BACKGROUND: Competitive flow from saphenous vein grafts (SVG) that remain patent following percutaneous coronary intervention (PCI) of the native vessel may compromise durability of the reconstructed vessel. SVG sacrifice has been advocated, but the safety and longer-term outcomes of this are unknown. METHODS: We retrospectively reviewed all post-bypass patients who following successful PCI of the native vessel underwent attempted saphenous vein graft (SVG) closure between January 2014 and July 2018 in two institutions. The co-primary end-points of interest were safety and target lesion failure (TLF), defined as a composite of cardiac death, target vessel recurrent myocardial infarction or clinically driven target lesion revascularisation (TLR). RESULTS: Of the 33 consecutive patients included, the reconstructed native vessel was a chronic total occlusion (CTO) in 93.9% of patients (n = 31) with a mean J-CTO score of 3.2 (±1.1) SVG closure was successful in 97.0% of patients (n = 32). Amplatzer Vascular Plugs (AVP; Abbott Vascular) were used in all patients with most grafts closed by a single plug (72.7%). The average procedure time was 20.1 min with evidence of a short learning curve. Over a mean follow up of 602 (±393) days from the date of SVG closure, the incidence of TLF was 9.1% (n = 3). There was an additional case of targe vessel failure (TVF) due to progression of native vessel disease not treated at the index procedure. SVG closure resulted in only 1 episode of "slow flow" that was transient and self-resolving. There were no other associated peri-procedural or in-hospital complications. CONCLUSION: Following native vessel PCI, SVG sacrifice may be considered to terminate the potentially deleterious effects of residual competitive flow. In selected cases, this approach achieves high success rate and favourable longer-term outcomes.


Subject(s)
Coronary Artery Bypass , Coronary Artery Disease/therapy , Coronary Occlusion/therapy , Percutaneous Coronary Intervention , Saphenous Vein/transplantation , Aged , Chronic Disease , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass/mortality , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Artery Disease/physiopathology , Coronary Circulation , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/mortality , Coronary Occlusion/physiopathology , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Retrospective Studies , Risk Factors , Saphenous Vein/diagnostic imaging , Saphenous Vein/physiopathology , Time Factors , Treatment Outcome , United Kingdom , Vascular Patency
SELECTION OF CITATIONS
SEARCH DETAIL