Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
Medicina (Kaunas) ; 57(6)2021 May 31.
Article in English | MEDLINE | ID: mdl-34072775

ABSTRACT

Background and Objectives: Obstructive sleep apnea (OSA) is a common disorder with an increased risk for left ventricular and right ventricular dysfunction. Most studies to date have examined populations with manifest cardiovascular disease using echocardiography to analyze ventricular dysfunction with little or no reference to ventricular volumes or myocardial mass. Our aim was to explore these parameters with cardiac MRI. We hypothesized that there would be stepwise increase in left ventricular mass and right ventricular volumes from the unaffected, to the snoring and the OSA group. Materials and Methods: We analyzed cardiac MRI data from 4978 UK Biobank participants free from cardiovascular disease. Participants were allocated into three cohorts: with OSA, with self-reported snoring and without OSA or snoring (n = 118, 1886 and 2477). We analyzed cardiac parameters from balanced cine-SSFP sequences and indexed them to body surface area. Results: Patients with OSA were mostly males (47.3% vs. 79.7%; p < 0.001) with higher body mass index (25.7 ± 4.0 vs. 31.3 ± 5.3 kg/m²; p < 0.001) and higher blood pressure (135 ± 18 vs. 140 ± 17 mmHg; p = 0.012) compared to individuals without OSA or snoring. Regression analysis showed a significant effect for OSA in left ventricular end-diastolic index (LVEDVI) (ß = -4.9 ± 2.4 mL/m²; p = 0.040) and right ventricular end-diastolic index (RVEDVI) (ß = -6.2 ± 2.6 mL/m²; p = 0.016) in females and for right ventricular ejection fraction (RVEF) (ß = 1.7 ± 0.8%; p = 0.031) in males. A significant effect was discovered in snoring females for left ventricular mass index (LVMI) (ß = 3.5 ± 0.9 g/m²; p < 0.001) and in males for left ventricular ejection fraction (LVEF) (ß = 1.0 ± 0.3%; p = 0.001) and RVEF (ß = 1.2 ± 0.3%; p < 0.001). Conclusion: Our study suggests that OSA is highly underdiagnosed and that it is an evolving process with gender specific progression. Females with OSA show significantly lower ventricular volumes while males with snoring show increased ejection fractions which may be an early sign of hypertrophy. Separate prospective studies are needed to further explore the direction of causality.


Subject(s)
Biological Specimen Banks , Snoring , Female , Humans , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Male , Prospective Studies , Snoring/diagnostic imaging , Stroke Volume , United Kingdom , Ventricular Function, Left , Ventricular Function, Right
2.
J Cardiovasc Magn Reson ; 23(1): 5, 2020 12 17.
Article in English | MEDLINE | ID: mdl-33407573

ABSTRACT

BACKGROUND: Mitral valve (MV) and tricuspid valve (TV) apparatus geometry are essential to define mechanisms and etiologies of regurgitation and to inform surgical or transcatheter interventions. Given the increasing use of cardiovascular magnetic resonance (CMR) for the evaluation of valvular heart disease, we aimed to establish CMR-derived age- and sex-specific reference values for mitral annular (MA) and tricuspid annular (TA) dimensions and tethering indices derived from truly healthy Caucasian adults. METHODS: 5065 consecutive UK Biobank participants underwent CMR using cine balanced steady-state free precession imaging at 1.5 T. Participants with non-Caucasian ethnicity, prevalent cardiovascular disease and other conditions known to affect cardiac chamber size and function were excluded. Absolute and indexed reference ranges for MA and TA diameters and tethering indices were stratified by gender and age (45-54, 55-64, 65-74 years). RESULTS: Overall, 721 (14.2%) truly healthy participants aged 45-74 years (54% women) formed the reference cohort. Absolute MA and TA diameters, MV tenting length and MV tenting area, were significantly larger in men. Mean ± standard deviation (SD) end-diastolic and end-systolic MA diameters in the 3-chamber view (anteroposterior diameter) were 2.9 ± 0.4 cm (1.5 ± 0.2 cm/m2) and 3.3 ± 0.4 cm (1.7 ± 0.2 cm/m2) in men, and 2.6 ± 0.4 cm (1.6 ± 0.2 cm/m2) and 3.0 ± 0.4 cm (1.8 ± 0.2 cm/m2) in women, respectively. Mean ± SD end-diastolic and end-systolic TA diameters in the 4-chamber view were 3.2 ± 0.5 cm (1.6 ± 0.3 cm/m2) and 3.2 ± 0.5 cm (1.7 ± 0.3 cm/m2) in men, and 2.9 ± 0.4 cm (1.7 ± 0.2 cm/m2) and 2.8 ± 0.4 cm (1.7 ± 0.3 cm/m2) in women, respectively. With advancing age, end-diastolic TA diameter became larger and posterior MV leaflet angle smaller in both sexes. Reproducibility of measurements was good to excellent with an inter-rater intraclass correlation coefficient (ICC) between 0.92 and 0.98 and an intra-rater ICC between 0.90 and 0.97. CONCLUSIONS: We described age- and sex-specific reference ranges of MA and TA dimensions and tethering indices in the largest validated healthy Caucasian population. Reference ranges presented in this study may help to improve the distinction between normal and pathological states, prompting the identification of subjects that may benefit from advanced cardiac imaging for annular sizing and planning of valvular interventions.


Subject(s)
Magnetic Resonance Imaging, Cine , Mitral Valve/diagnostic imaging , Tricuspid Valve/diagnostic imaging , Age Factors , Aged , Cross-Sectional Studies , Female , Healthy Volunteers , Humans , Male , Middle Aged , Observer Variation , Predictive Value of Tests , Reference Values , Reproducibility of Results , Sex Factors , United Kingdom , White People
3.
J Cardiovasc Magn Reson ; 21(1): 18, 2019 03 14.
Article in English | MEDLINE | ID: mdl-30866968

ABSTRACT

BACKGROUND: The trend towards large-scale studies including population imaging poses new challenges in terms of quality control (QC). This is a particular issue when automatic processing tools such as image segmentation methods are employed to derive quantitative measures or biomarkers for further analyses. Manual inspection and visual QC of each segmentation result is not feasible at large scale. However, it is important to be able to automatically detect when a segmentation method fails in order to avoid inclusion of wrong measurements into subsequent analyses which could otherwise lead to incorrect conclusions. METHODS: To overcome this challenge, we explore an approach for predicting segmentation quality based on Reverse Classification Accuracy, which enables us to discriminate between successful and failed segmentations on a per-cases basis. We validate this approach on a new, large-scale manually-annotated set of 4800 cardiovascular magnetic resonance (CMR) scans. We then apply our method to a large cohort of 7250 CMR on which we have performed manual QC. RESULTS: We report results used for predicting segmentation quality metrics including Dice Similarity Coefficient (DSC) and surface-distance measures. As initial validation, we present data for 400 scans demonstrating 99% accuracy for classifying low and high quality segmentations using the predicted DSC scores. As further validation we show high correlation between real and predicted scores and 95% classification accuracy on 4800 scans for which manual segmentations were available. We mimic real-world application of the method on 7250 CMR where we show good agreement between predicted quality metrics and manual visual QC scores. CONCLUSIONS: We show that Reverse classification accuracy has the potential for accurate and fully automatic segmentation QC on a per-case basis in the context of large-scale population imaging as in the UK Biobank Imaging Study.


Subject(s)
Heart/diagnostic imaging , Image Interpretation, Computer-Assisted/standards , Magnetic Resonance Imaging/standards , Automation , Humans , Predictive Value of Tests , Quality Control , Reproducibility of Results , United Kingdom
4.
J Cardiovasc Magn Reson ; 20(1): 65, 2018 09 14.
Article in English | MEDLINE | ID: mdl-30217194

ABSTRACT

BACKGROUND: Cardiovascular resonance (CMR) imaging is a standard imaging modality for assessing cardiovascular diseases (CVDs), the leading cause of death globally. CMR enables accurate quantification of the cardiac chamber volume, ejection fraction and myocardial mass, providing information for diagnosis and monitoring of CVDs. However, for years, clinicians have been relying on manual approaches for CMR image analysis, which is time consuming and prone to subjective errors. It is a major clinical challenge to automatically derive quantitative and clinically relevant information from CMR images. METHODS: Deep neural networks have shown a great potential in image pattern recognition and segmentation for a variety of tasks. Here we demonstrate an automated analysis method for CMR images, which is based on a fully convolutional network (FCN). The network is trained and evaluated on a large-scale dataset from the UK Biobank, consisting of 4,875 subjects with 93,500 pixelwise annotated images. The performance of the method has been evaluated using a number of technical metrics, including the Dice metric, mean contour distance and Hausdorff distance, as well as clinically relevant measures, including left ventricle (LV) end-diastolic volume (LVEDV) and end-systolic volume (LVESV), LV mass (LVM); right ventricle (RV) end-diastolic volume (RVEDV) and end-systolic volume (RVESV). RESULTS: By combining FCN with a large-scale annotated dataset, the proposed automated method achieves a high performance in segmenting the LV and RV on short-axis CMR images and the left atrium (LA) and right atrium (RA) on long-axis CMR images. On a short-axis image test set of 600 subjects, it achieves an average Dice metric of 0.94 for the LV cavity, 0.88 for the LV myocardium and 0.90 for the RV cavity. The mean absolute difference between automated measurement and manual measurement is 6.1 mL for LVEDV, 5.3 mL for LVESV, 6.9 gram for LVM, 8.5 mL for RVEDV and 7.2 mL for RVESV. On long-axis image test sets, the average Dice metric is 0.93 for the LA cavity (2-chamber view), 0.95 for the LA cavity (4-chamber view) and 0.96 for the RA cavity (4-chamber view). The performance is comparable to human inter-observer variability. CONCLUSIONS: We show that an automated method achieves a performance on par with human experts in analysing CMR images and deriving clinically relevant measures.


Subject(s)
Heart Diseases/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Myocardial Contraction , Neural Networks, Computer , Stroke Volume , Ventricular Function, Left , Ventricular Function, Right , Aged , Automation , Databases, Factual , Deep Learning , Female , Heart Diseases/physiopathology , Humans , Male , Middle Aged , Observer Variation , Predictive Value of Tests , Reproducibility of Results
5.
J Cardiovasc Magn Reson ; 19(1): 18, 2017 Feb 03.
Article in English | MEDLINE | ID: mdl-28178995

ABSTRACT

BACKGROUND: Cardiovascular magnetic resonance (CMR) is the gold standard method for the assessment of cardiac structure and function. Reference ranges permit differentiation between normal and pathological states. To date, this study is the largest to provide CMR specific reference ranges for left ventricular, right ventricular, left atrial and right atrial structure and function derived from truly healthy Caucasian adults aged 45-74. METHODS: Five thousand sixty-five UK Biobank participants underwent CMR using steady-state free precession imaging at 1.5 Tesla. Manual analysis was performed for all four cardiac chambers. Participants with non-Caucasian ethnicity, known cardiovascular disease and other conditions known to affect cardiac chamber size and function were excluded. Remaining participants formed the healthy reference cohort; reference ranges were calculated and were stratified by gender and age (45-54, 55-64, 65-74). RESULTS: After applying exclusion criteria, 804 (16.2%) participants were available for analysis. Left ventricular (LV) volumes were larger in males compared to females for absolute and indexed values. With advancing age, LV volumes were mostly smaller in both sexes. LV ejection fraction was significantly greater in females compared to males (mean ± standard deviation [SD] of 61 ± 5% vs 58 ± 5%) and remained static with age for both genders. In older age groups, LV mass was lower in men, but remained virtually unchanged in women. LV mass was significantly higher in males compared to females (mean ± SD of 53 ± 9 g/m2 vs 42 ± 7 g/m2). Right ventricular (RV) volumes were significantly larger in males compared to females for absolute and indexed values and were smaller with advancing age. RV ejection fraction was higher with increasing age in females only. Left atrial (LA) maximal volume and stroke volume were significantly larger in males compared to females for absolute values but not for indexed values. LA ejection fraction was similar for both sexes. Right atrial (RA) maximal volume was significantly larger in males for both absolute and indexed values, while RA ejection fraction was significantly higher in females. CONCLUSIONS: We describe age- and sex-specific reference ranges for the left ventricle, right ventricle and atria in the largest validated normal Caucasian population.


Subject(s)
Atrial Function, Left , Atrial Function, Right , Biological Specimen Banks , Heart/diagnostic imaging , Heart/physiology , Magnetic Resonance Imaging/standards , Ventricular Function, Left , Ventricular Function, Right , White People , Age Factors , Aged , Female , Humans , Male , Middle Aged , Observer Variation , Predictive Value of Tests , Reference Values , Reproducibility of Results , Sex Factors , Stroke Volume , United Kingdom
6.
Front Cardiovasc Med ; 8: 816985, 2021.
Article in English | MEDLINE | ID: mdl-35242820

ABSTRACT

BACKGROUND: The quantitative measures used to assess the performance of automated methods often do not reflect the clinical acceptability of contouring. A quality-based assessment of automated cardiac magnetic resonance (CMR) segmentation more relevant to clinical practice is therefore needed. OBJECTIVE: We propose a new method for assessing the quality of machine learning (ML) outputs. We evaluate the clinical utility of the proposed method as it is employed to systematically analyse the quality of an automated contouring algorithm. METHODS: A dataset of short-axis (SAX) cine CMR images from a clinically heterogeneous population (n = 217) were manually contoured by a team of experienced investigators. On the same images we derived automated contours using a ML algorithm. A contour quality scoring application randomly presented manual and automated contours to four blinded clinicians, who were asked to assign a quality score from a predefined rubric. Firstly, we analyzed the distribution of quality scores between the two contouring methods across all clinicians. Secondly, we analyzed the interobserver reliability between the raters. Finally, we examined whether there was a variation in scores based on the type of contour, SAX slice level, and underlying disease. RESULTS: The overall distribution of scores between the two methods was significantly different, with automated contours scoring better than the manual (OR (95% CI) = 1.17 (1.07-1.28), p = 0.001; n = 9401). There was substantial scoring agreement between raters for each contouring method independently, albeit it was significantly better for automated segmentation (automated: AC2 = 0.940, 95% CI, 0.937-0.943 vs manual: AC2 = 0.934, 95% CI, 0.931-0.937; p = 0.006). Next, the analysis of quality scores based on different factors was performed. Our approach helped identify trends patterns of lower segmentation quality as observed for left ventricle epicardial and basal contours with both methods. Similarly, significant differences in quality between the two methods were also found in dilated cardiomyopathy and hypertension. CONCLUSIONS: Our results confirm the ability of our systematic scoring analysis to determine the clinical acceptability of automated contours. This approach focused on the contours' clinical utility could ultimately improve clinicians' confidence in artificial intelligence and its acceptability in the clinical workflow.

7.
Eur Heart J Cardiovasc Imaging ; 22(9): 1009-1016, 2021 08 14.
Article in English | MEDLINE | ID: mdl-33313691

ABSTRACT

AIMS: Data regarding the effects of regular alcohol consumption on cardiac anatomy and function are scarce. Therefore, we sought to determine the relationship between regular alcohol intake and cardiac structure and function as evaluated with cardiac magnetic resonance imaging. METHODS AND RESULTS: Participants of the UK Biobank who underwent cardiac magnetic resonance were enrolled in our analysis. Data regarding regular alcohol consumption were obtained from questionnaires filled in by the study participants. Exclusion criteria were poor image quality, missing, or incongruent data regarding alcohol drinking habits, prior drinking, presence of heart failure or angina, and prior myocardial infarction or stroke. Overall, 4335 participants (61.5 ± 7.5 years, 47.6% male) were analysed. We used multivariate linear regression models adjusted for age, ethnicity, body mass index, smoking, hypertension, diabetes mellitus, physical activity, cholesterol level, and Townsend deprivation index to examine the relationship between regular alcohol intake and cardiac structure and function. In men, alcohol intake was independently associated with marginally increased left ventricular end-diastolic volume [ß = 0.14; 95% confidence interval (CI) = 0.05-0.24; P = 0.004], left ventricular stroke volume (ß = 0.08; 95% CI = 0.03-0.14; P = 0.005), and right ventricular stroke volume (ß = 0.08; 95% CI = 0.02-0.13; P = 0.006). In women, alcohol consumption was associated with increased left atrium volume (ß = 0.14; 95% CI = 0.04-0.23; P = 0.006). CONCLUSION: Alcohol consumption is independently associated with a marginal increase in left and right ventricular volumes in men, but not in women, whereas alcohol intake showed an association with increased left atrium volume in women. Our results suggest that there is only minimal relationship between regular alcohol consumption and cardiac morphology and function in an asymptomatic middle-aged population.


Subject(s)
Biological Specimen Banks , Magnetic Resonance Imaging , Alcohol Drinking/epidemiology , Female , Heart Atria/diagnostic imaging , Humans , Magnetic Resonance Spectroscopy , Male , Middle Aged , Stroke Volume , United Kingdom/epidemiology , Ventricular Function, Left
8.
Front Cardiovasc Med ; 7: 105, 2020.
Article in English | MEDLINE | ID: mdl-32714943

ABSTRACT

Background: Convolutional neural network (CNN) based segmentation methods provide an efficient and automated way for clinicians to assess the structure and function of the heart in cardiac MR images. While CNNs can generally perform the segmentation tasks with high accuracy when training and test images come from the same domain (e.g., same scanner or site), their performance often degrades dramatically on images from different scanners or clinical sites. Methods: We propose a simple yet effective way for improving the network generalization ability by carefully designing data normalization and augmentation strategies to accommodate common scenarios in multi-site, multi-scanner clinical imaging data sets. We demonstrate that a neural network trained on a single-site single-scanner dataset from the UK Biobank can be successfully applied to segmenting cardiac MR images across different sites and different scanners without substantial loss of accuracy. Specifically, the method was trained on a large set of 3,975 subjects from the UK Biobank. It was then directly tested on 600 different subjects from the UK Biobank for intra-domain testing and two other sets for cross-domain testing: the ACDC dataset (100 subjects, 1 site, 2 scanners) and the BSCMR-AS dataset (599 subjects, 6 sites, 9 scanners). Results: The proposed method produces promising segmentation results on the UK Biobank test set which are comparable to previously reported values in the literature, while also performing well on cross-domain test sets, achieving a mean Dice metric of 0.90 for the left ventricle, 0.81 for the myocardium, and 0.82 for the right ventricle on the ACDC dataset; and 0.89 for the left ventricle, 0.83 for the myocardium on the BSCMR-AS dataset. Conclusions: The proposed method offers a potential solution to improve CNN-based model generalizability for the cross-scanner and cross-site cardiac MR image segmentation task.

9.
Med Image Anal ; 56: 26-42, 2019 08.
Article in English | MEDLINE | ID: mdl-31154149

ABSTRACT

Population imaging studies generate data for developing and implementing personalised health strategies to prevent, or more effectively treat disease. Large prospective epidemiological studies acquire imaging for pre-symptomatic populations. These studies enable the early discovery of alterations due to impending disease, and enable early identification of individuals at risk. Such studies pose new challenges requiring automatic image analysis. To date, few large-scale population-level cardiac imaging studies have been conducted. One such study stands out for its sheer size, careful implementation, and availability of top quality expert annotation; the UK Biobank (UKB). The resulting massive imaging datasets (targeting ca. 100,000 subjects) has put published approaches for cardiac image quantification to the test. In this paper, we present and evaluate a cardiac magnetic resonance (CMR) image analysis pipeline that properly scales up and can provide a fully automatic analysis of the UKB CMR study. Without manual user interactions, our pipeline performs end-to-end image analytics from multi-view cine CMR images all the way to anatomical and functional bi-ventricular quantification. All this, while maintaining relevant quality controls of the CMR input images, and resulting image segmentations. To the best of our knowledge, this is the first published attempt to fully automate the extraction of global and regional reference ranges of all key functional cardiovascular indexes, from both left and right cardiac ventricles, for a population of 20,000 subjects imaged at 50 time frames per subject, for a total of one million CMR volumes. In addition, our pipeline provides 3D anatomical bi-ventricular models of the heart. These models enable the extraction of detailed information of the morphodynamics of the two ventricles for subsequent association to genetic, omics, lifestyle habits, exposure information, and other information provided in population imaging studies. We validated our proposed CMR analytics pipeline against manual expert readings on a reference cohort of 4620 subjects with contour delineations and corresponding clinical indexes. Our results show broad significant agreement between the manually obtained reference indexes, and those automatically computed via our framework. 80.67% of subjects were processed with mean contour distance of less than 1 pixel, and 17.50% with mean contour distance between 1 and 2 pixels. Finally, we compare our pipeline with a recently published approach reporting on UKB data, and based on deep learning. Our comparison shows similar performance in terms of segmentation accuracy with respect to human experts.


Subject(s)
Heart Ventricles/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Models, Statistical , Neural Networks, Computer , Biological Specimen Banks , Female , Humans , Imaging, Three-Dimensional , Male , Pattern Recognition, Automated , United Kingdom
10.
PLoS One ; 14(10): e0223125, 2019.
Article in English | MEDLINE | ID: mdl-31644534

ABSTRACT

INTRODUCTION: Cardiovascular disease (CVD) is more common in women who have had pregnancy complications such as spontaneous pregnancy loss. We used cross-sectional data from the UK Biobank Imaging Enhancement Study to determine whether pregnancy loss is associated with cardiac or vascular remodelling in later life, which might contribute to this increased risk. METHODS: Pregnancy history was reported by women participating in UK Biobank between 2006 and 2010 at age 40-69 years using a self-completed touch-screen questionnaire. Associations between self-reported spontaneous pregnancy loss and cardiovascular measures, collected in women who participated in the Imaging Enhancement Study up to the end of 2015, were examined. Cardiac structure and function were assessed by magnetic resonance (CMR) steady-state free precession imaging at 1.5 Tesla. Carotid intima-media thickness (CIMT) measurements were taken for both common carotid arteries using a CardioHealth Station. Statistical associations with CMR and carotid measures were adjusted for age, BMI and other cardiovascular risk factors. RESULTS: Data were available on 2660 women of whom 111 were excluded because of pre-existing cardiovascular disease and 30 had no pregnancy information available. Of the remaining 2519, 446 were nulligravid and 2073 had a history of pregnancies, of whom 622 reported at least one pregnancy loss (92% miscarriages and 8% stillbirths) and 1451 reported no pregnancy loss. No significant differences in any cardiac or carotid parameters were evident in women who reported pregnancy loss compared to other groups (Table 1). CONCLUSION: Women who self-report pregnancy loss do not have significant differences in cardiac structure, cardiac function, or carotid structure in later life to explain their increased cardiovascular risk. This suggests any cardiovascular risks associated with pregnancy loss operate through other disease mechanisms. Alternatively, other characteristics of pregnancy loss, which we were not able to take account of, such as timing and number of pregnancy losses may be required to identify those at greatest cardiovascular risk.


Subject(s)
Abortion, Spontaneous/epidemiology , Biological Specimen Banks , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/etiology , Self Report , Adult , Aged , Cardiovascular Diseases/diagnostic imaging , Carotid Intima-Media Thickness , Confounding Factors, Epidemiologic , Female , Humans , Magnetic Resonance Imaging , Middle Aged , Pregnancy , Risk Factors , United Kingdom/epidemiology
11.
PLoS One ; 13(3): e0193124, 2018.
Article in English | MEDLINE | ID: mdl-29538386

ABSTRACT

BACKGROUND: Handgrip strength, a measure of muscular fitness, is associated with cardiovascular (CV) events and CV mortality but its association with cardiac structure and function is unknown. The goal of this study was to determine if handgrip strength is associated with changes in cardiac structure and function in UK adults. METHODS AND RESULTS: Left ventricular (LV) ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), mass (M), and mass-to-volume ratio (MVR) were measured in a sample of 4,654 participants of the UK Biobank Study 6.3 ± 1 years after baseline using cardiovascular magnetic resonance (CMR). Handgrip strength was measured at baseline and at the imaging follow-up examination. We determined the association between handgrip strength at baseline as well as its change over time and each of the cardiac outcome parameters. After adjustment, higher level of handgrip strength at baseline was associated with higher LVEDV (difference per SD increase in handgrip strength: 1.3ml, 95% CI 0.1-2.4; p = 0.034), higher LVSV (1.0ml, 0.3-1.8; p = 0.006), lower LVM (-1.0g, -1.8 --0.3; p = 0.007), and lower LVMVR (-0.013g/ml, -0.018 --0.007; p<0.001). The association between handgrip strength and LVEDV and LVSV was strongest among younger individuals, while the association with LVM and LVMVR was strongest among older individuals. CONCLUSIONS: Better handgrip strength was associated with cardiac structure and function in a pattern indicative of less cardiac hypertrophy and remodeling. These characteristics are known to be associated with a lower risk of cardiovascular events.


Subject(s)
Cardiovascular Diseases/physiopathology , Hand Strength , Stroke Volume , Ventricular Function, Left , Adult , Aged , Cardiovascular Diseases/mortality , Female , Humans , Male , Middle Aged , Prospective Studies
12.
PLoS One ; 13(3): e0194015, 2018.
Article in English | MEDLINE | ID: mdl-29518141

ABSTRACT

BACKGROUND: The effect of menopausal hormone therapy (MHT)-previously known as hormone replacement therapy-on cardiovascular health remains unclear and controversial. This cross-sectional study examined the impact of MHT on left ventricular (LV) and left atrial (LA) structure and function, alterations in which are markers of subclinical cardiovascular disease, in a population-based cohort. METHODS: Post-menopausal women who had never used MHT and those who had used MHT ≥3 years participating in the UK Biobank who had undergone cardiovascular magnetic resonance (CMR) imaging and free of known cardiovascular disease were included. Multivariable linear regression was performed to examine the relationship between cardiac parameters and MHT use ≥3 years. To explore whether MHT use on each of the cardiac outcomes differed by age, multivariable regression models were constructed with a cross-product of age and MHT fitted as an interaction term. RESULTS: Of 1604 post-menopausal women, 513 (32%) had used MHT ≥3 years. In the MHT cohort, median age at menopause was 50 (IQR: 45-52) and median duration of MHT was 8 years. In the non-MHT cohort, median age at menopause was 51 (IQR: 48-53). MHT use was associated with significantly lower LV end-diastolic volume (122.8 ml vs 119.8 ml, effect size = -2.4%, 95% CI: -4.2% to -0.5%; p = 0.013) and LA maximal volume (60.2 ml vs 57.5 ml, effect size = -4.5%, 95% CI: -7.8% to -1.0%; p = 0.012). There was no significant difference in LV mass. MHT use significantly modified the effect between age and CMR parameters; MHT users had greater decrements in LV end-diastolic volume, LV end-systolic volume and LA maximal volume with advancing age. CONCLUSIONS: MHT use was not associated with adverse, subclinical changes in cardiac structure and function. Indeed, significantly smaller LV and LA chamber volumes were observed which have been linked to favourable cardiovascular outcomes. These findings represent a novel approach to examining MHT's effect on the cardiovascular system.


Subject(s)
Cardiovascular Diseases/prevention & control , Heart Atria/drug effects , Heart Ventricles/drug effects , Hormone Replacement Therapy , Aging , Comorbidity , Cross-Sectional Studies , Female , Follow-Up Studies , Humans , Magnetic Resonance Imaging , Menopause , Middle Aged , Postmenopause , Risk Factors , Stroke Volume/drug effects , United Kingdom/epidemiology
13.
Int J Cardiovasc Imaging ; 34(2): 281-291, 2018 Feb.
Article in English | MEDLINE | ID: mdl-28836039

ABSTRACT

UK Biobank, a large cohort study, plans to acquire 100,000 cardiac MRI studies by 2020. Although fully-automated left ventricular (LV) analysis was performed in the original acquisition, this was not designed for unsupervised incorporation into epidemiological studies. We sought to evaluate automated LV mass and volume (Siemens syngo InlineVF versions D13A and E11C), against manual analysis in a substantial sub-cohort of UK Biobank participants. Eight readers from two centers, trained to give consistent results, manually analyzed 4874 UK Biobank cases for LV end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF) and LV mass (LVM). Agreement between manual and InlineVF automated analyses were evaluated using Bland-Altman analysis and the intra-class correlation coefficient (ICC). Tenfold cross-validation was used to establish a linear regression calibration between manual and InlineVF results. InlineVF D13A returned results in 4423 cases, whereas InlineVF E11C returned results in 4775 cases and also reported LVM. Rapid visual assessment of the E11C results found 178 cases (3.7%) with grossly misplaced contours or landmarks. In the remaining 4597 cases, LV function showed good agreement: ESV -6.4 ± 9.0 ml, 0.853 (mean ± SD of the differences, ICC) EDV -3.0 ± 11.6 ml, 0.937; SV 3.4 ± 9.8 ml, 0.855; and EF 3.5 ± 5.1%, 0.586. Although LV mass was consistently overestimated (29.9 ± 17.0 g, 0.534) due to larger epicardial contours on all slices, linear regression could be used to correct the bias and improve accuracy. Automated InlineVF results can be used for case-control studies in UK Biobank, provided visual quality control and linear bias correction are performed. Improvements between InlineVF D13A and InlineVF E11C show the field is rapidly advancing, with further improvements expected in the near future.


Subject(s)
Heart Diseases/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Stroke Volume , Ventricular Function, Left , Aged , Algorithms , Automation , Female , Heart Diseases/physiopathology , Humans , Linear Models , Male , Middle Aged , Observer Variation , Predictive Value of Tests , Reproducibility of Results , United Kingdom
14.
PLoS One ; 13(3): e0194434, 2018.
Article in English | MEDLINE | ID: mdl-29558496

ABSTRACT

BACKGROUND: Reduced lung function is common and associated with increased cardiovascular morbidity and mortality, even in asymptomatic individuals without diagnosed respiratory disease. Previous studies have identified relationships between lung function and cardiovascular structure in individuals with pulmonary disease, but the relationships in those free from diagnosed cardiorespiratory disease have not been fully explored. METHODS: UK Biobank is a prospective cohort study of community participants in the United Kingdom. Individuals self-reported demographics and co-morbidities, and a subset underwent cardiovascular magnetic resonance (CMR) imaging and spirometry. CMR images were analysed to derive ventricular volumes and mass. The relationships between CMR-derived measures and spirometry and age were modelled with multivariable linear regression, taking account of the effects of possible confounders. RESULTS: Data were available for 4,975 individuals, and after exclusion of those with pre-existing cardiorespiratory disease and unacceptable spirometry, 1,406 were included in the analyses. In fully-adjusted multivariable linear models lower FEV1 and FVC were associated with smaller left ventricular end-diastolic (-5.21ml per standard deviation (SD) change in FEV1, -5.69ml per SD change in FVC), end-systolic (-2.34ml, -2.56ml) and stroke volumes (-2.85ml, -3.11ml); right ventricular end-diastolic (-5.62ml, -5.84ml), end-systolic (-2.47ml, -2.46ml) and stroke volumes (-3.13ml, -3.36ml); and with lower left ventricular mass (-2.29g, -2.46g). Changes of comparable magnitude and direction were observed per decade increase in age. CONCLUSIONS: This study shows that reduced FEV1 and FVC are associated with smaller ventricular volumes and reduced ventricular mass. The changes seen per standard deviation change in FEV1 and FVC are comparable to one decade of ageing.


Subject(s)
Biological Specimen Banks , Heart/diagnostic imaging , Heart/physiopathology , Lung/physiopathology , Magnetic Resonance Imaging/methods , Myocardium/pathology , Female , Forced Expiratory Volume , Humans , Linear Models , Male , Middle Aged , Prospective Studies , Respiratory Function Tests/methods , Spirometry/methods , Stroke Volume , United Kingdom
15.
PLoS One ; 12(10): e0185114, 2017.
Article in English | MEDLINE | ID: mdl-28973022

ABSTRACT

AIMS: The UK Biobank is a large-scale population-based study utilising cardiovascular magnetic resonance (CMR) to generate measurements of atrial and ventricular structure and function. This study aimed to quantify the association between modifiable cardiovascular risk factors and cardiac morphology and function in individuals without known cardiovascular disease. METHODS: Age, sex, ethnicity (non-modifiable) and systolic blood pressure, diastolic blood pressure, smoking status, exercise, body mass index (BMI), high cholesterol, diabetes, alcohol intake (modifiable) were considered important cardiovascular risk factors. Multivariable regression models were built to ascertain the association of risk factors on left ventricular (LV), right ventricular (RV), left atrial (LA) and right atrial (RA) CMR parameters. RESULTS: 4,651 participants were included in the analysis. All modifiable risk factors had significant effects on differing atrial and ventricular parameters. BMI was the modifiable risk factor most consistently associated with subclinical changes to CMR parameters, particularly in relation to higher LV mass (+8.3% per SD [4.3 kg/m2], 95% CI: 7.6 to 8.9%), LV (EDV: +4.8% per SD, 95% CI: 4.2 to 5.4%); ESV: +4.4% per SD, 95% CI: 3.5 to 5.3%), RV (EDV: +5.3% per SD, 95% CI: 4.7 to 5.9%; ESV: +5.4% per SD, 95% CI: 4.5 to 6.4%) and LA maximal (+8.6% per SD, 95% CI: 7.4 to 9.7%) volumes. Increases in SBP were associated with higher LV mass (+6.8% per SD, 95% CI: 5.9 to 7.7%), LV (EDV: +4.5% per SD, 95% CI: 3.6 to 5.4%; ESV: +2.0% per SD, 95% CI: 0.8 to 3.3%) volumes. The presence of diabetes or high cholesterol resulted in smaller volumes and lower ejection fractions. CONCLUSIONS: Modifiable risk factors are associated with subclinical alterations in structure and function in all four cardiac chambers. BMI and systolic blood pressure are the most important modifiable risk factors affecting CMR parameters known to be linked to adverse outcomes.


Subject(s)
Biological Specimen Banks , Heart/diagnostic imaging , Radiographic Image Enhancement/methods , Aged , Body Mass Index , Female , Heart/anatomy & histology , Heart/physiology , Humans , Male , Middle Aged , Risk Factors , United Kingdom
SELECTION OF CITATIONS
SEARCH DETAIL