Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 153
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Magn Reson Med ; 92(4): 1392-1403, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38725240

ABSTRACT

PURPOSE: A method is proposed to quantify cerebral blood volume ( v b $$ {v}_b $$ ) and intravascular water residence time ( τ b $$ {\tau}_b $$ ) using MR fingerprinting (MRF), applied using a spoiled gradient echo sequence without the need for contrast agent. METHODS: An in silico study optimized an acquisition protocol to maximize the sensitivity of the measurement to v b $$ {v}_b $$ and τ b $$ {\tau}_b $$ changes. Its accuracy in the presence of variations in T 1 , t $$ {\mathrm{T}}_{1,t} $$ , T 1 , b $$ {\mathrm{T}}_{1,b} $$ , and B 1 $$ {\mathrm{B}}_1 $$ was evaluated. The optimized protocol (scan time of 19 min) was then tested in a exploratory healthy volunteer study (10 volunteers, mean age 24 ± $$ \pm $$ 3, six males) at 3 T with a repeat scan taken after repositioning to allow estimation of repeatability. RESULTS: Simulations show that assuming literature values for T 1 , b $$ {\mathrm{T}}_{1,b} $$ and T 1 , t $$ {\mathrm{T}}_{1,t} $$ , no variation in B 1 $$ {\mathrm{B}}_1 $$ , while fitting only v b $$ {v}_b $$ and τ b $$ {\tau}_b $$ , leads to large errors in quantification of v b $$ {v}_b $$ and τ b $$ {\tau}_b $$ , regardless of noise levels. However, simulations also show that matching T 1 , t $$ {\mathrm{T}}_{1,t} $$ , T 1 , b $$ {\mathrm{T}}_{1,b} $$ , B 1 + $$ {\mathrm{B}}_1^{+} $$ , v b $$ {v}_b $$ and τ b $$ {\tau}_b $$ , simultaneously is feasible at clinically achievable noise levels. Across the healthy volunteers, all parameter quantifications fell within the expected literature range. In addition, the maps show good agreement between hemispheres suggesting physiologically relevant information is being extracted. Expected differences between white and gray matter T 1 , t $$ {\mathrm{T}}_{1,t} $$ (p < 0.0001) and v b $$ {v}_b $$ (p < 0.0001) are observed, T 1 , b $$ {\mathrm{T}}_{1,b} $$ and τ b $$ {\tau}_b $$ show no significant differences, p = 0.4 and p = 0.6, respectively. Moderate to excellent repeatability was seen between repeat scans: mean intra-class correlation coefficient of T 1 , t : 0 . 91 $$ {\mathrm{T}}_{1,t}:0.91 $$ , T 1 , b : 0 . 58 $$ {\mathrm{T}}_{1,b}:0.58 $$ , v b : 0 . 90 $$ {v}_b:0.90 $$ , and τ b : 0 . 96 $$ {\tau}_b:0.96 $$ . CONCLUSION: We demonstrate that regional simultaneous quantification of v b $$ {v}_b $$ , τ b $$ {\tau}_b $$ , T 1 , b , T 1 , t $$ {\mathrm{T}}_{1,b},{T}_{1,t} $$ , and B 1 + $$ {\mathrm{B}}_1^{+} $$ using MRF is feasible in vivo.


Subject(s)
Blood-Brain Barrier , Computer Simulation , Magnetic Resonance Imaging , Water , Humans , Male , Magnetic Resonance Imaging/methods , Blood-Brain Barrier/diagnostic imaging , Blood-Brain Barrier/metabolism , Adult , Female , Brain/diagnostic imaging , Young Adult , Image Processing, Computer-Assisted/methods , Healthy Volunteers , Reproducibility of Results , Algorithms
2.
Magn Reson Med ; 91(3): 972-986, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38013206

ABSTRACT

PURPOSE: To demonstrate proof-of-concept of a T2 *-sensitized oxygen-enhanced MRI (OE-MRI) method at 3T by assessing signal characteristics, repeatability, and reproducibility of dynamic lung OE-MRI metrics in healthy volunteers. METHODS: We performed sequence-specific simulations for protocol optimisation and acquired free-breathing OE-MRI data from 16 healthy subjects using a dual-echo RF-spoiled gradient echo approach at 3T across two institutions. Non-linear registration and tissue density correction were applied. Derived metrics included percent signal enhancement (PSE), ∆R2 * and wash-in time normalized for breathing rate (τ-nBR). Inter-scanner reproducibility and intra-scanner repeatability were evaluated using intra-class correlation coefficient (ICC), repeatability coefficient, reproducibility coefficient, and Bland-Altman analysis. RESULTS: Simulations and experimental data show negative contrast upon oxygen inhalation, due to substantial dominance of ∆R2 * at TE > 0.2 ms. Density correction improved signal fluctuations. Density-corrected mean PSE values, aligned with simulations, display TE-dependence, and an anterior-to-posterior PSE reduction trend at TE1 . ∆R2 * maps exhibit spatial heterogeneity in oxygen delivery, featuring anterior-to-posterior R2 * increase. Mean T2 * values across 32 scans were 0.68 and 0.62 ms for pre- and post-O2 inhalation, respectively. Excellent or good agreement emerged from all intra-, inter-scanner and inter-rater variability tests for PSE and ∆R2 *. However, ICC values for τ-nBR demonstrated limited agreement between repeated measures. CONCLUSION: Our results demonstrate the feasibility of a T2 *-weighted method utilizing a dual-echo RF-spoiled gradient echo approach, simultaneously capturing PSE, ∆R2 * changes, and oxygen wash-in during free-breathing. The excellent or good repeatability and reproducibility on intra- and inter-scanner PSE and ∆R2 * suggest potential utility in multi-center clinical applications.


Subject(s)
Magnetic Resonance Imaging , Oxygen , Humans , Reproducibility of Results , Feasibility Studies , Magnetic Resonance Imaging/methods , Lung/diagnostic imaging
3.
Magn Reson Med ; 91(3): 955-971, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37984456

ABSTRACT

PURPOSE: Dynamic lung oxygen-enhanced MRI (OE-MRI) is challenging due to the presence of confounding signals and poor signal-to-noise ratio, particularly at 3 T. We have created a robust pipeline utilizing independent component analysis (ICA) to automatically extract the oxygen-induced signal change from confounding factors to improve the accuracy and sensitivity of lung OE-MRI. METHODS: Dynamic OE-MRI was performed on healthy participants using a dual-echo multi-slice spoiled gradient echo sequence at 3 T and cyclical gas delivery. ICA was applied to each echo within a thoracic mask. The ICA component relating to the oxygen-enhancement signal was automatically identified using correlation analysis. The oxygen-enhancement component was reconstructed, and the percentage signal enhancement (PSE) was calculated. The lung PSE of current smokers was compared with nonsmokers; scan-rescan repeatability, ICA pipeline repeatability, and reproducibility between two vendors were assessed. RESULTS: ICA successfully extracted a consistent oxygen-enhancement component for all participants. Lung tissue and oxygenated blood displayed the opposite oxygen-induced signal enhancements. A significant difference in PSE was observed between the lungs of current smokers and nonsmokers. The scan-rescan repeatability and the ICA pipeline repeatability were good. CONCLUSION: The developed pipeline demonstrated sensitivity to the signal enhancements of the lung tissue and oxygenated blood at 3 T. The difference in lung PSE between current smokers and nonsmokers indicates a likely sensitivity to lung function alterations that may be seen in mild pathology, supporting future use of our methods in patient studies.


Subject(s)
Lung , Oxygen , Humans , Reproducibility of Results , Lung/diagnostic imaging , Magnetic Resonance Imaging/methods
4.
Magn Reson Med ; 91(5): 1803-1821, 2024 May.
Article in English | MEDLINE | ID: mdl-38115695

ABSTRACT

PURPOSE: K trans $$ {K}^{\mathrm{trans}} $$ has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for K trans $$ {K}^{\mathrm{trans}} $$ quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging-Dynamic Contrast-Enhanced (OSIPI-DCE) challenge was designed to benchmark methods to better help the efforts to standardize K trans $$ {K}^{\mathrm{trans}} $$ measurement. METHODS: A framework was created to evaluate K trans $$ {K}^{\mathrm{trans}} $$ values produced by DCE-MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for K trans $$ {K}^{\mathrm{trans}} $$ quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' K trans $$ {K}^{\mathrm{trans}} $$ values, the applied software, and a standard operating procedure. These were evaluated using the proposed OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score defined with accuracy, repeatability, and reproducibility components. RESULTS: Across the 10 received submissions, the OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0-1 = lowest-highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in K trans $$ {K}^{\mathrm{trans}} $$ analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility. CONCLUSIONS: This study reports results from the OSIPI-DCE challenge and highlights the high inter-software variability within K trans $$ {K}^{\mathrm{trans}} $$ estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real-world clinical setting, many of these tools may perform differently with different benchmarking methodology.


Subject(s)
Contrast Media , Magnetic Resonance Imaging , Humans , Reproducibility of Results , Magnetic Resonance Imaging/methods , Software , Algorithms
5.
NMR Biomed ; : e5239, 2024 Aug 25.
Article in English | MEDLINE | ID: mdl-39183451

ABSTRACT

Sensitivity analysis enables the identification of influential parameters and the optimisation of model composition. Such methods have not previously been applied systematically to models describing hyperpolarised 129Xe gas exchange in the lung. Here, we evaluate the current 129Xe gas exchange models to assess their precision for identifying alterations in pulmonary vascular function and lung microstructure. We assess sensitivity using established univariate methods and scatter plots for parameter interactions. We apply them to the model described by Patz et al and the Model of Xenon Exchange (MOXE), examining their ability to measure: i) importance (rank), ii) temporal dependence and iii) interaction effects of each parameter across healthy and diseased ranges. The univariate methods and scatter plot analyses demonstrate consistently similar results for the importance of parameters common to both models evaluated. Alveolar surface area to volume ratio is identified as the parameter to which model signals are most sensitive. The alveolar-capillary barrier thickness is identified as a low-sensitivity parameter for the MOXE model. An acquisition window of at least 200 ms effectively demonstrates model sensitivity to most parameters. Scatter plots reveal interaction effects in both models, impacting output variability and sensitivity. Our sensitivity analysis ranks the parameters within the model described by Patz et al and within the MOXE model. The MOXE model shows low sensitivity to alveolar-capillary barrier thickness, highlighting the need for designing acquisition protocols optimised for the measurement of this parameter. The presence of parameter interaction effects highlights the requirement for care in interpreting model outputs.

6.
Biol Lett ; 20(10): 20240489, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39378984

ABSTRACT

In eukaryotes, gamete size difference between the two sexes (anisogamy) evolved from gametes of equal size in both mating types (isogamy). The gamete dynamics (GD) model for anisogamy evolution combines gamete limitation and competition and predicts that if gametes of both mating types can develop parthenogenetically (i.e. without fusing with the opposite mating type), large isogamy can evolve under gamete-limited conditions. Ulvophycean marine green algae that have been claimed to exhibit various gametic systems from isogamy to anisogamy are important models for testing such theories. However, in most previous papers, whether a species is isogamous or anisogamous has not been examined statistically. Caution is necessary regarding claims of slight anisogamy because of gamete size variation. We reveal (i) that the gametic system of Struvea okamurae is large isogamy using a generalized linear mixed model, which accounted for the variation of gamete size among individual gametophytes, and (ii) that gametes of this alga can actually develop parthenogenetically, contrary to a previous report. Its habitat environments and protracted duration of gamete release suggest that this alga might experience gamete-limited conditions. Struvea okamurae seems to produce large parthenogenetic isogametes following GD model predictions, as an adaptation to deep waters.


Subject(s)
Biological Evolution , Models, Biological , Parthenogenesis , Germ Cells, Plant/physiology , Chlorophyta/physiology , Reproduction/physiology
7.
Magn Reson Med ; 90(1): 34-50, 2023 07.
Article in English | MEDLINE | ID: mdl-36892973

ABSTRACT

PURPOSE: To evaluate potential modeling paradigms and the impact of relaxation time effects on human blood-brain barrier (BBB) water exchange measurements using FEXI (BBB-FEXI), and to quantify the accuracy, precision, and repeatability of BBB-FEXI exchange rate estimates at 3 T $$ \mathrm{T} $$ . METHODS: Three modeling paradigms were evaluated: (i) the apparent exchange rate (AXR) model; (ii) a two-compartment model ( 2 CM $$ 2\mathrm{CM} $$ ) explicitly representing intra- and extravascular signal components, and (iii) a two-compartment model additionally accounting for finite compartmental T 1 $$ {\mathrm{T}}_1 $$ and T 2 $$ {\mathrm{T}}_2 $$ relaxation times ( 2 CM r $$ 2{\mathrm{CM}}_r $$ ). Each model had three free parameters. Simulations quantified biases introduced by the assumption of infinite relaxation times in the AXR and 2 CM $$ 2\mathrm{CM} $$ models, as well as the accuracy and precision of all three models. The scan-rescan repeatability of all paradigms was quantified for the first time in vivo in 10 healthy volunteers (age range 23-52 years; five female). RESULTS: The assumption of infinite relaxation times yielded exchange rate errors in simulations up to 42%/14% in the AXR/ 2 CM $$ 2\mathrm{CM} $$ models, respectively. Accuracy was highest in the compartmental models; precision was best in the AXR model. Scan-rescan repeatability in vivo was good for all models, with negligible bias and repeatability coefficients in grey matter of RC AXR = 0 . 43 $$ {\mathrm{RC}}_{\mathrm{AXR}}=0.43 $$ s - 1 $$ {\mathrm{s}}^{-1} $$ , RC 2 CM = 0 . 51 $$ {\mathrm{RC}}_{2\mathrm{CM}}=0.51 $$ s - 1 $$ {\mathrm{s}}^{-1} $$ , and RC 2 CM r = 0 . 61 $$ {\mathrm{RC}}_{2{\mathrm{CM}}_r}=0.61 $$ s - 1 $$ {\mathrm{s}}^{-1} $$ . CONCLUSION: Compartmental modelling of BBB-FEXI signals can provide accurate and repeatable measurements of BBB water exchange; however, relaxation time and partial volume effects may cause model-dependent biases.


Subject(s)
Blood-Brain Barrier , Water , Humans , Female , Young Adult , Adult , Middle Aged , Blood-Brain Barrier/diagnostic imaging , Algorithms , Computer Simulation , Magnetic Resonance Imaging
8.
Magn Reson Med ; 90(1): 150-165, 2023 07.
Article in English | MEDLINE | ID: mdl-36941736

ABSTRACT

PURPOSE: Tensor-valued diffusion encoding can probe more specific features of tissue microstructure than what is available by conventional diffusion weighting. In this work, we investigate the technical feasibility of tensor-valued diffusion encoding at high b-values with q-space trajectory imaging (QTI) analysis, in the human heart in vivo. METHODS: Ten healthy volunteers were scanned on a 3T scanner. We designed time-optimal gradient waveforms for tensor-valued diffusion encoding (linear and planar) with second-order motion compensation. Data were analyzed with QTI. Normal values and repeatability were investigated for the mean diffusivity (MD), fractional anisotropy (FA), microscopic FA (µFA), isotropic, anisotropic and total mean kurtosis (MKi, MKa, and MKt), and orientation coherence (Cc ). A phantom, consisting of two fiber blocks at adjustable angles, was used to evaluate sensitivity of parameters to orientation dispersion and diffusion time. RESULTS: QTI data in the left ventricular myocardium were MD = 1.62 ± 0.07 µm2 /ms, FA = 0.31 ± 0.03, µFA = 0.43 ± 0.07, MKa = 0.20 ± 0.07, MKi = 0.13 ± 0.03, MKt = 0.33 ± 0.09, and Cc  = 0.56 ± 0.22 (mean ± SD across subjects). Phantom experiments showed that FA depends on orientation dispersion, whereas µFA was insensitive to this effect. CONCLUSION: We demonstrated the first tensor-valued diffusion encoding and QTI analysis in the heart in vivo, along with first measurements of myocardial µFA, MKi, MKa, and Cc . The methodology is technically feasible and provides promising novel biomarkers for myocardial tissue characterization.


Subject(s)
Diffusion Tensor Imaging , Heart , Humans , Diffusion Tensor Imaging/methods , Heart/diagnostic imaging , Diffusion Magnetic Resonance Imaging , Myocardium , Heart Ventricles , Anisotropy
9.
NMR Biomed ; 36(11): e5009, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37666494

ABSTRACT

A technique for quantifying regional blood-brain barrier (BBB) water exchange rates using contrast-enhanced arterial spin labelling (CE-ASL) is presented and evaluated in simulations and in vivo. The two-compartment ASL model describes the water exchange rate from blood to tissue, k b , but to estimate k b in practice it is necessary to separate the intra- and extravascular signals. This is challenging in standard ASL data owing to the small difference in T 1 values. Here, a gadolinium-based contrast agent is used to increase this T 1 difference and enable the signal components to be disentangled. The optimal post-contrast blood T 1 ( T 1 , b post ) at 3 T was determined in a sensitivity analysis, and the accuracy and precision of the method quantified using Monte Carlo simulations. Proof-of-concept data were acquired in six healthy volunteers (five female, age range 24-46 years). The sensitivity analysis identified the optimal T 1 , b post at 3 T as 0.8 s. Simulations showed that k b could be estimated in individual cortical regions with a relative error ϵ < 1 % and coefficient of variation CoV = 30 %; however, a high dependence on blood T 1 was also observed. In volunteer data, mean parameter values in grey matter were: arterial transit time t A = 1 . 15 ± 0 . 49 s, cerebral blood flow f = 58 . 0 ± 14 . 3 mL blood/min/100 mL tissue and water exchange rate k b = 2 . 32 ± 2 . 49 s-1 . CE-ASL can provide regional BBB water exchange rate estimates; however, the clinical utility of the technique is dependent on the achievable accuracy of measured T 1 values.


Subject(s)
Blood-Brain Barrier , Brain , Humans , Female , Young Adult , Adult , Middle Aged , Blood-Brain Barrier/diagnostic imaging , Brain/physiology , Water , Magnetic Resonance Imaging/methods , Gray Matter , Spin Labels , Cerebrovascular Circulation/physiology
10.
Biol Lett ; 19(9): 20230352, 2023 09.
Article in English | MEDLINE | ID: mdl-37752851

ABSTRACT

In eukaryotes, a fundamental phenomenon underlying sexual selection is the evolution of gamete size dimorphism between the sexes (anisogamy) from an ancestral gametic system with gametes of the same size in both mating types (isogamy). The nuclear-cytoplasmic conflict hypothesis has been one of the major theoretical hypotheses for the evolution of anisogamy. It proposes that anisogamy evolved as an adaptation for preventing nuclear-cytoplasmic conflict by minimizing male gamete size to inherit organelles uniparentally. In ulvophycean green algae, biparental inheritance of organelles is observed in isogamous species, as the hypothesis assumes. So we tested the hypothesis by examining whether cytoplasmic inheritance is biparental in Monostroma angicava, a slightly anisogamous ulvophycean that produces large male gametes. We tracked the fates of mitochondria in intraspecific crosses with PCR-RFLP markers. We confirmed that mitochondria are maternally inherited. However, paternal mitochondria enter the zygote, where their DNA can be detected for over 14 days. This indicates that uniparental inheritance is enforced by eliminating paternal mitochondrial DNA in the zygote, rather than by decreasing male gamete size to the minimum. Thus, uniparental cytoplasmic inheritance is achieved by an entirely different mechanism, and is unlikely to drive the evolution of anisogamy in ulvophyceans.


Subject(s)
DNA, Mitochondrial , Mitochondria , Male , Humans , DNA, Mitochondrial/genetics , Inheritance Patterns , Polymerase Chain Reaction , Fertilization
11.
Neuroimage ; 242: 118445, 2021 11 15.
Article in English | MEDLINE | ID: mdl-34375753

ABSTRACT

Microscopic diffusion anisotropy imaging using diffusion-weighted MRI and multidimensional diffusion encoding is a promising method for quantifying clinically and scientifically relevant microstructural properties of neural tissue. Several methods for estimating microscopic fractional anisotropy (µFA), a normalized measure of microscopic diffusion anisotropy, have been introduced but the differences between the methods have received little attention thus far. In this study, the accuracy and precision of µFA estimation using q-space trajectory encoding and different signal models were assessed using imaging experiments and simulations. Three healthy volunteers and a microfibre phantom were imaged with five non-zero b-values and gradient waveforms encoding linear and spherical b-tensors. Since the ground-truth µFA was unknown in the imaging experiments, Monte Carlo random walk simulations were performed using axon-mimicking fibres for which the ground truth was known. Furthermore, parameter bias due to time-dependent diffusion was quantified by repeating the simulations with tuned waveforms, which have similar power spectra, and with triple diffusion encoding, which, unlike q-space trajectory encoding, is not based on the assumption of time-independent diffusion. The truncated cumulant expansion of the powder-averaged signal, gamma-distributed diffusivities assumption, and q-space trajectory imaging, a generalization of the truncated cumulant expansion to individual signals, were used to estimate µFA. The gamma-distributed diffusivities assumption consistently resulted in greater µFA values than the second order cumulant expansion, 0.1 greater when averaged over the whole brain. In the simulations, the generalized cumulant expansion provided the most accurate estimates. Importantly, although time-dependent diffusion caused significant overestimation of µFA using all the studied methods, the simulations suggest that the resulting bias in µFA is less than 0.1 in human white matter.


Subject(s)
Anisotropy , Brain/diagnostic imaging , Diffusion Tensor Imaging/instrumentation , Adult , Female , Humans , Image Processing, Computer-Assisted/instrumentation , Male , Monte Carlo Method , Phantoms, Imaging , White Matter/diagnostic imaging
12.
Am Nat ; 197(2): E40-E54, 2021 02.
Article in English | MEDLINE | ID: mdl-33523790

ABSTRACT

AbstractParasitic worms with complex life cycles have several developmental stages, with each stage creating opportunities to infect additional host species. Using a data set for 973 species of trophically transmitted acanthocephalans, cestodes, and nematodes, we confirmed that worms with longer life cycles (i.e., more successive hosts) infect a greater diversity of host species and taxa (after controlling for study effort). Generalism at the stage level was highest for middle life stages, the second and third intermediate hosts of long life cycles. By simulating life cycles in real food webs, we found that middle stages had more potential host species to infect, suggesting that opportunity constrains generalism. However, parasites usually infected fewer host species than expected from simulated cycles, suggesting that generalism has costs. There was no trade-off in generalism from one stage to the next, but worms spent less time growing and developing in stages where they infected more taxonomically diverse hosts. Our results demonstrate that life-cycle complexity favors high generalism and that host use across life stages is determined by both ecological opportunity and life-history trade-offs.


Subject(s)
Acanthocephala/physiology , Cestoda/physiology , Host Specificity , Host-Parasite Interactions , Nematoda/physiology , Animals , Food Chain , Life Cycle Stages
13.
Am Nat ; 198(3): 360-378, 2021 09.
Article in English | MEDLINE | ID: mdl-34403316

ABSTRACT

AbstractThe two sexes are defined by the sizes of the gametes they produce, anisogamy being the state with two differing gamete sizes (hence, females and males). The origin of this divergence has received much research interest, both theoretically and empirically. The gamete dynamics (GD) theory is a widely accepted theoretical explanation for anisogamy, and green algae have been an important empirical testing ground for the theory. However, some green and brown algae produce parthenogenetic gametes (gametes that can develop without fusing with another gamete), in contrast to an assumption in GD theory that unfused gametes do not develop. Here, we construct a GD model accounting for parthenogenetic gametes. We find that under conditions of panmixia and highly efficient fertilization (i.e., conditions of classical GD models from 1972 onward), the results remain largely unaltered by parthenogametes. However, under gamete-limited conditions anisogamy evolves less easily in the new model, and a novel result emerges: whereas previous models typically predict the evolution of either anisogamy or small isogamy, the current model shows that large isogamy can evolve when parthenogenetic gametes evolve under conditions of inefficient fertilization. Our analyses uncover unexplored complications relating to sex ratios under this relatively uncharted gametic system. We discuss limitations these complications impose on our models and suggest avenues for future research. We compare model results to algae with parthenogenetic gametes in nature.


Subject(s)
Biological Evolution , Chlorophyta , Germ Cells , Reproduction , Sex
14.
Magn Reson Med ; 86(3): 1314-1329, 2021 09.
Article in English | MEDLINE | ID: mdl-33780045

ABSTRACT

PURPOSE: We sought to determine the degree to which oxygen extraction fraction (OEF) estimated using quantitative susceptibility mapping (QSM) depends on two critical acquisition parameters that have a significant impact on acquisition time: voxel size and final echo time. METHODS: Four healthy volunteers were imaged using a range of isotropic voxel sizes and final echo times. The 0.7 mm data were downsampled at different stages of QSM processing by a factor of 2 (to 1.4 mm), 3 (2.1 mm), or 4 (2.8 mm) to determine the impact of voxel size on each analysis step. OEF was estimated from 11 veins of varying diameter. Inter- and intra-session repeatability were estimated for the optimal protocol by repeat scanning in 10 participants. RESULTS: Final echo time was found to have no significant effect on OEF. The effect of voxel size was significant, with larger voxel sizes underestimating OEF, depending on the proximity of the vein to the superficial surface of the brain and on vein diameter. The last analysis step of estimating vein OEF values from susceptibility images had the largest dependency on voxel size. Inter-session coefficients of variation on OEF estimates of between 5.2% and 8.7% are reported, depending on the vein. CONCLUSION: QSM acquisition times can be minimized by reducing the final echo time but an isotropic voxel size no larger than 1 mm is needed to accurately estimate OEF in most medium/large veins in the brain. Such acquisitions can be achieved in under 4 min.


Subject(s)
Brain Mapping , Oxygen , Brain/diagnostic imaging , Cerebrovascular Circulation , Humans , Magnetic Resonance Imaging , Oxygen Consumption
15.
Magn Reson Med ; 86(4): 1829-1844, 2021 10.
Article in English | MEDLINE | ID: mdl-33973674

ABSTRACT

PURPOSE: We introduce a novel, generalized tracer kinetic model selection framework to quantify microvascular characteristics of liver and tumor tissue in gadoxetate-enhanced dynamic contrast-enhanced MRI (DCE-MRI). METHODS: Our framework includes a hierarchy of nested models, from which physiological parameters are derived in 2 regimes, corresponding to the active transport and free diffusion of gadoxetate. We use simulations to show the sensitivity of model selection and parameter estimation to temporal resolution, time-series duration, and noise. We apply the framework in 8 healthy volunteers (time-series duration up to 24 minutes) and 10 patients with hepatocellular carcinoma (6 minutes). RESULTS: The active transport regime is preferred in 98.6% of voxels in volunteers, 82.1% of patients' non-tumorous liver, and 32.2% of tumor voxels. Interpatient variations correspond to known co-morbidities. Simulations suggest both datasets have sufficient temporal resolution and signal-to-noise ratio, while patient data would be improved by using a time-series duration of at least 12 minutes. CONCLUSIONS: In patient data, gadoxetate exhibits different kinetics: (a) between liver and tumor regions and (b) within regions due to liver disease and/or tumor heterogeneity. Our generalized framework selects a physiological interpretation at each voxel, without preselecting a model for each region or duplicating time-consuming optimizations for models with identical functional forms.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Carcinoma, Hepatocellular/diagnostic imaging , Contrast Media , Gadolinium DTPA , Humans , Liver/diagnostic imaging , Liver Neoplasms/diagnostic imaging , Magnetic Resonance Imaging
16.
Magn Reson Med ; 86(3): 1514-1530, 2021 09.
Article in English | MEDLINE | ID: mdl-33960501

ABSTRACT

PURPOSE: Recent advances in diffusion-weighted MRI provide "restricted diffusion signal fraction" and restricting pore size estimates. Materials based on co-electrospun oriented hollow cylinders have been introduced to provide validation for such methods. This study extends this work, exploring accuracy and repeatability using an extended acquisition on a 300 mT/m gradient human MRI scanner, in substrates closely mimicking tissue, that is, non-circular cross-sections, intra-voxel fiber crossing, intra-voxel distributions of pore-sizes, and smaller pore-sizes overall. METHODS: In a single-blind experiment, diffusion-weighted data were collected from a biomimetic phantom on a 3T Connectom system using multiple gradient directions/diffusion times. Repeated scans established short-term and long-term repeatability. The total scan time (54 min) matched similar protocols used in human studies. The number of distinct fiber populations was estimated using spherical deconvolution, and median pore size estimated through the combination of CHARMED and AxCaliber3D framework. Diffusion-based estimates were compared with measurements derived from scanning electron microscopy. RESULTS: The phantom contained substrates with different orientations, fiber configurations, and pore size distributions. Irrespective of one or two populations within the voxel, the pore-size estimates (~5 µm) and orientation-estimates showed excellent agreement with the median values of pore-size derived from scanning electron microscope and phantom configuration. Measurement repeatability depended on substrate complexity, with lower values seen in samples containing crossing-fibers. Sample-level repeatability was found to be good. CONCLUSION: While no phantom mimics tissue completely, this study takes a step closer to validating diffusion microstructure measurements for use in vivo by demonstrating the ability to quantify microgeometry in relatively complex configurations.


Subject(s)
Biomimetics , Diffusion Magnetic Resonance Imaging , Brain , Humans , Microscopy, Electron, Scanning , Phantoms, Imaging , Single-Blind Method
17.
Magn Reson Med ; 86(4): 1888-1903, 2021 10.
Article in English | MEDLINE | ID: mdl-34002894

ABSTRACT

PURPOSE: Dynamic contrast-enhanced (DCE) -MRI with Patlak model analysis is increasingly used to quantify low-level blood-brain barrier (BBB) leakage in studies of pathophysiology. We aimed to investigate systematic errors due to physiological, experimental, and modeling factors influencing quantification of the permeability-surface area product PS and blood plasma volume vp , and to propose modifications to reduce the errors so that subtle differences in BBB permeability can be accurately measured. METHODS: Simulations were performed to predict the effects of potential sources of systematic error on conventional PS and vp quantification: restricted BBB water exchange, reduced cerebral blood flow, arterial input function (AIF) delay and B1+ error. The impact of targeted modifications to the acquisition and processing were evaluated, including: assumption of fast versus no BBB water exchange, bolus versus slow injection of contrast agent, exclusion of early data from model fitting and B1+ correction. The optimal protocol was applied in a cohort of recent mild ischaemic stroke patients. RESULTS: Simulation results demonstrated substantial systematic errors due to the factors investigated (absolute PS error ≤ 4.48 × 10-4 min-1 ). However, these were reduced (≤0.56 × 10-4 min-1 ) by applying modifications to the acquisition and processing pipeline. Processing modifications also had substantial effects on in-vivo normal-appearing white matter PS estimation (absolute change ≤ 0.45 × 10-4 min-1 ). CONCLUSION: Measuring subtle BBB leakage with DCE-MRI presents unique challenges and is affected by several confounds that should be considered when acquiring or interpreting such data. The evaluated modifications should improve accuracy in studies of neurodegenerative diseases involving subtle BBB breakdown.


Subject(s)
Brain Ischemia , Stroke , Blood-Brain Barrier/diagnostic imaging , Contrast Media , Humans , Magnetic Resonance Imaging
18.
NMR Biomed ; 34(7): e4510, 2021 07.
Article in English | MEDLINE | ID: mdl-33723901

ABSTRACT

The effects of Alzheimer's disease (AD) and ageing on blood-brain barrier (BBB) breakdown are investigated in TgF344-AD and wild-type rats aged 13, 18 and 21 months. Permeability surface area products of the BBB to water (PSw ) and gadolinium-based contrast agent (PSg ) were measured in grey matter using multiflip angle multiecho dynamic contrast-enhanced MRI. At 13 months of age, there was no significant difference in PSw between TgF344-AD and wild-types (p = 0.82). Between 13 and 18 months, PSw increased in TgF344-AD rats (p = 0.027), but not in wild-types (p = 0.99), leading to significantly higher PSw in TgF344-AD rats at 18 months, as previously reported (p = 0.012). Between 18 and 21 months, PSw values increased in wild-types (p = 0.050), but not in TgF344-AD rats (p = 0.50). These results indicate that BBB water permeability is affected by both AD pathology and ageing, but that changes occur earlier in the presence of AD pathology. There were no significant genotype or ageing effects on PSg (p > 0.05). In conclusion, we detected increases in BBB water permeability with age in TgF344-AD and wild-type rats, and found that changes occurred at an earlier age in rats with AD pathology.


Subject(s)
Aging/pathology , Alzheimer Disease/pathology , Blood-Brain Barrier/pathology , Water , Animals , Female , Hippocampus/metabolism , Male , Models, Biological , Permeability , Rats, Inbred F344 , Rats, Transgenic
19.
BMC Cancer ; 21(1): 354, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-33794823

ABSTRACT

BACKGROUND: Patients with metastatic colorectal cancer are treated with cytotoxic chemotherapy supplemented by molecularly targeted therapies. There is a critical need to define biomarkers that can optimise the use of these therapies to maximise efficacy and avoid unnecessary toxicity. However, it is important to first define the changes in potential biomarkers following cytotoxic chemotherapy alone. This study reports the impact of standard cytotoxic chemotherapy across a range of circulating and imaging biomarkers. METHODS: A single-centre, prospective, biomarker-driven study. Eligible patients included those diagnosed with colorectal cancer with liver metastases that were planned to receive first line oxaliplatin plus 5-fluorouracil or capecitabine. Patients underwent paired blood sampling and magnetic resonance imaging (MRI), and biomarkers were associated with progression-free survival (PFS) and overall survival (OS). RESULTS: Twenty patients were recruited to the study. Data showed that chemotherapy significantly reduced the number of circulating tumour cells as well as the circulating concentrations of Ang1, Ang2, VEGF-A, VEGF-C and VEGF-D from pre-treatment to cycle 2 day 2. The changes in circulating concentrations were not associated with PFS or OS. On average, the MRI perfusion/permeability parameter, Ktrans, increased in response to cytotoxic chemotherapy from pre-treatment to cycle 2 day 2 and this increase was associated with worse OS (HR 1.099, 95%CI 1.01-1.20, p = 0.025). CONCLUSIONS: In patients diagnosed with colorectal cancer with liver metastases, treatment with standard chemotherapy changes cell- and protein-based biomarkers, although these changes are not associated with survival outcomes. In contrast, the imaging biomarker, Ktrans, offers promise to direct molecularly targeted therapies such as anti-angiogenic agents.


Subject(s)
Biomarkers, Tumor/metabolism , Capecitabine/therapeutic use , Fluorouracil/therapeutic use , Oxaliplatin/therapeutic use , Aged , Capecitabine/pharmacology , Female , Fluorouracil/pharmacology , Humans , Male , Neoplasm Metastasis , Oxaliplatin/pharmacology , Prospective Studies
20.
Eur Radiol ; 31(8): 5746-5758, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33591383

ABSTRACT

OBJECTIVES: Evaluate test-retest repeatability, ability to discriminate between osteoarthritic and healthy participants, and sensitivity to change over 6 months, of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) biomarkers in knee OA. METHODS: Fourteen individuals aged 40-60 with mild-moderate knee OA and 6 age-matched healthy volunteers (HV) underwent DCE-MRI at 3 T at baseline, 1 month and 6 months. Voxelwise pharmacokinetic modelling of dynamic data was used to calculate DCE-MRI biomarkers including Ktrans and IAUC60. Median DCE-MRI biomarker values were extracted for each participant at each study visit. Synovial segmentation was performed using both manual and semiautomatic methods with calculation of an additional biomarker, the volume of enhancing pannus (VEP). Test-retest repeatability was assessed using intraclass correlation coefficients (ICC). Smallest detectable differences (SDDs) were calculated from test-retest data. Discrimination between OA and HV was assessed via calculation of between-group standardised mean differences (SMD). Responsiveness was assessed via the number of OA participants with changes greater than the SDD at 6 months. RESULTS: Ktrans demonstrated the best test-retest repeatability (Ktrans/IAUC60/VEP ICCs 0.90/0.84/0.40, SDDs as % of OA mean 33/71/76%), discrimination between OA and HV (SMDs 0.94/0.54/0.50) and responsiveness (5/1/1 out of 12 OA participants with 6-month change > SDD) when compared to IAUC60 and VEP. Biomarkers derived from semiautomatic segmentation outperformed those derived from manual segmentation across all domains. CONCLUSIONS: Ktrans demonstrated the best repeatability, discrimination and sensitivity to change suggesting that it is the optimal DCE-MRI biomarker for use in experimental medicine studies. KEY POINTS: • Dynamic contrast-enhanced MRI (DCE-MRI) provides quantitative measures of synovitis in knee osteoarthritis which may permit early assessment of efficacy in experimental medicine studies. • This prospective observational study compared DCE-MRI biomarkers across domains relevant to experimental medicine: test-retest repeatability, discriminative validity and sensitivity to change. • The DCE-MRI biomarker Ktrans demonstrated the best performance across all three domains, suggesting that it is the optimal biomarker for use in future interventional studies.


Subject(s)
Osteoarthritis, Knee , Synovitis , Contrast Media , Humans , Infant , Knee Joint , Magnetic Resonance Imaging , Osteoarthritis, Knee/diagnostic imaging , Prospective Studies , Synovitis/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL