Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 26
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Appl Microbiol Biotechnol ; 108(1): 74, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38194146

ABSTRACT

Donor human milk (DHM) provides myriad nutritional and immunological benefits for preterm and low birthweight infants. However, pasteurization leaves DHM devoid of potentially beneficial milk microbiota. In the present study, we performed milk microbiome transplantation from freshly collected mother's own milk (MOM) into pasteurized DHM. Small volumes of MOM (5%, 10%, or 30% v/v) were inoculated into pasteurized DHM and incubated at 37 °C for up to 8 h. Further, we compared microbiome recolonization in UV-C-treated and Holder-pasteurized DHM, as UV-C treatment has been shown to conserve important biochemical components of DHM that are lost during Holder pasteurization. Bacterial culture and viability-coupled metataxonomic sequencing were employed to assess the effectiveness of milk microbiome transplantation. Growth of transplanted MOM bacteria occurred rapidly in recolonized DHM samples; however, a greater level of growth was observed in Holder-pasteurized DHM compared to UV-C-treated DHM, potentially due to the conserved antimicrobial properties in UV-C-treated DHM. Viability-coupled metataxonomic analysis demonstrated similarity between recolonized DHM samples and fresh MOM samples, suggesting that the milk microbiome can be successfully transplanted into pasteurized DHM. These results highlight the potential of MOM microbiota transplantation to restore the microbial composition of UV-C-treated and Holder-pasteurized DHM and enhance the nutritional and immunological benefits of DHM for preterm and vulnerable infants. KEY POINTS: • Mother's own milk microbiome can be successfully transplanted into donor human milk. • Recolonization is equally successful in UV-C-treated and Holder-pasteurized milk. • Recolonization time should be restricted due to rapid bacterial growth.


Subject(s)
Microbiota , Milk, Human , Infant , Infant, Newborn , Female , Humans , Mothers , Pasteurization , Plant Leaves
2.
Curr Opin Clin Nutr Metab Care ; 25(3): 188-194, 2022 05 01.
Article in English | MEDLINE | ID: mdl-35142722

ABSTRACT

PURPOSE OF REVIEW: The coronavirus disease 2019 (COVID-19) pandemic has changed the birthing and postnatal experience of women. This review highlights how policy changes have affected pregnant and breastfeeding women, the evidence for continued breastfeeding and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccines, and how the pandemic's unexpected consequences have affected these women's wellbeing. Additionally, we postulate the future of lactation and perinatal support as the pandemic continues. RECENT FINDINGS: Women who have given birth during the pandemic have had restricted access to postnatal care. Although pregnant and breastfeeding women who contract SARS-CoV-2 are more vulnerable to poor health outcomes than their nonpregnant counterparts, they are also at higher risk of mental health difficulties, with limited access to support. Continued breastfeeding may be protective to the infant, offering passive immunity against SARS-CoV-2, and vaccination against COVID-19 is safe and effective for pregnant and lactating women. Innovative and adaptable lactation care, including holistic perinatal, mental health, and social support services, both digital and in-person, will help mothers continue breastfeeding during future outbreaks. SUMMARY: Continued breastfeeding and vaccination may confer protection to the infant against SARS-CoV-2 infection. New mothers should not be isolated in future pandemics. Prioritizing lactation and perinatal care, including in-person services, remains paramount to optimizing breastfeeding during COVID-19.


Subject(s)
COVID-19 , Breast Feeding , COVID-19/epidemiology , COVID-19/prevention & control , Female , Humans , Infant , Lactation , Pandemics/prevention & control , Pregnancy , SARS-CoV-2
3.
Eur J Pediatr ; 181(10): 3753-3766, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35976413

ABSTRACT

The COVID-19 pandemic has impacted new mothers' wellbeing and breastfeeding experience. Women have experienced changes in birth and postnatal care and restricted access to their support network. It is unclear how these impacts may have changed over time with shifting rates of infection and policies restricting movement and access to services in Australia and New Zealand. This study investigated the longitudinal effect of the COVID-19 pandemic on breastfeeding and maternal wellbeing in Australia and New Zealand. Mothers (n = 246) completed an online survey every 4 weeks for 6 months that examined feeding methods, maternal mental wellbeing, worries, challenges, and positive experiences during the pandemic. Mothers maintained high full breastfeeding rates at 4 months (81%) which decreased to 37% at 6 months. Perceived low milk supply contributed to the earlier cessation of full breastfeeding. Poor infant sleep was associated with stress, perinatal anxiety, mental wellbeing, and breastfeeding status. Although mothers initially reported that lockdowns helped with family bonding and less pressure, prolonged lockdowns appeared to have adverse effects on access to social networks and extended family support.    Conclusion: The results highlight the changing dynamic of the pandemic and the need for adaptable perinatal services which allow mothers access to in-person services and their support network even in lockdowns. Similarly, access to continuous education and clinical care remains critical for women experiencing concerns about their milk supply, infant sleep, and their own wellbeing. What is Known: • The COVID-19 pandemic and lockdown restrictions have significantly affected perinatal mental health, disrupted maternal services, and subsequent breastfeeding. What is New: • In Australia and New Zealand, breastfeeding women experienced challenges to their mental wellbeing, sleep, and breastfeeding, which was likely exacerbated over time by the pandemic. Lockdowns, while initially beneficial for some families, became detrimental to maternal support and wellbeing.


Subject(s)
Breast Feeding , COVID-19 , COVID-19/epidemiology , Communicable Disease Control , Female , Humans , Infant , Mothers , New Zealand/epidemiology , Pandemics , Pregnancy
4.
BMC Pregnancy Childbirth ; 22(1): 350, 2022 Apr 22.
Article in English | MEDLINE | ID: mdl-35459144

ABSTRACT

BACKGROUND: Gestational diabetes mellitus (GDM) is major pregnancy complication that is associated with short- and long-term consequences for both mother and infant, including increased risk of diabetes later in life. A longer breastfeeding duration has been associated with a reduced risk of diabetes, however, women with GDM are less likely to exclusively breastfeed and have shorter breastfeeding duration. While the timing of breastfeeding initiation and milk removal frequency affects subsequent breastfeeding outcomes, little is known about early infant feeding practices and milk production in women with GDM. This case series offers detailed prospective breastfeeding initiation data, as well as the first report of objective measures of milk production in women with GDM. CASE PRESENTATION: In this case series, we present the early infant feeding practices of eight women with GDM that gave birth at term gestation. Women recorded the timing of initiation of breastfeeding and secretory activation, as well as their breastfeeding, expression and formula feeding frequencies on postpartum days 1, 7 and 21. Measurement of 24 h milk production volume was performed at 3 weeks postpartum using the test weight method. We observed a delayed first breastfeed (> 1 h) in 6 (75%) cases, formula use in hospital in 5 (63%) cases and delayed secretory activation in 3 (38%) cases. At 3 weeks postpartum, 2 cases had measured milk productions that were insufficient to sustain adequate infant weight gain. CONCLUSIONS: Our data suggest that despite early and frequent milk removal, women with GDM are at greater risk of delayed secretory activation and low milk supply. Cohort studies that consider co-morbidities such as obesity are needed to determine the lactation outcomes of women with GDM.


Subject(s)
Diabetes, Gestational , Breast Feeding , Female , Humans , Infant , Milk, Human , Mothers , Pregnancy , Prospective Studies
5.
Adv Neonatal Care ; 22(6): 571-577, 2022 Dec 01.
Article in English | MEDLINE | ID: mdl-34743110

ABSTRACT

BACKGROUND: Preterm infants have shorter breastfeeding duration than that of term infants. Details of postdischarge feeding methods and difficulties are needed to inform the care of preterm breastfeeding dyads. PURPOSE: To describe postdischarge breastfeeding characteristics of mother-preterm infant dyads up to 12 weeks corrected gestational age (CGA). METHODS: A prospective observational study of preterm dyads (birth 24-33 weeks' gestation) that fed their mother's own milk (MOM) at discharge from a neonatal unit in Perth, Western Australia. Feeding method and frequency, breastfeeding duration, difficulties, and nipple shield use were recorded at 2, 6, and 12 weeks CGA. RESULTS: Data were obtained for 49 mothers (singleton infant n = 39, twins n = 10). At 12 weeks CGA, 59% fed any MOM with 47% exclusively fed MOM and 31% fully breastfed. Nipple shield use reduced from 42% at 2 weeks CGA to 11% at 12 weeks CGA. Compared with mothers who exclusively fed MOM at discharge (n = 41) those who fed both MOM and infant formula (n = 8) were more likely to wean before 12 weeks CGA ( P < .001). Weaning occurred before 2 weeks CGA in 12/19 (63%), with low milk supply the most frequently cited reason. IMPLICATIONS FOR PRACTICE: Most mothers with a full milk supply at discharge successfully transition to predominant breastfeeding. Frequent milk removal needs to be prioritized throughout the preterm infant's hospital stay. IMPLICATIONS FOR RESEARCH: Examination of facilitators and barriers to early and continued frequent milk removal across the postpartum period is required to identify strategies to optimize lactation after preterm birth.


Subject(s)
Breast Feeding , Premature Birth , Infant , Female , Infant, Newborn , Humans , Breast Feeding/methods , Infant, Premature , Gestational Age , Follow-Up Studies , Aftercare , Patient Discharge , Milk, Human , Mothers , Intensive Care Units, Neonatal
6.
Int J Mol Sci ; 22(16)2021 Aug 13.
Article in English | MEDLINE | ID: mdl-34445437

ABSTRACT

Human milk (HM) contains a wide array of peptide hormones including leptin and adiponectin, which are involved in the regulation of infant growth and development. These essential hormones might play an important role in the regulation of metabolic reprogramming of the new-born infant. However, HM hormone studies are sparse and heterogeneous in regard to the study design, sample collection, preparation and analysis methods. This review discussed the limitations of HM hormone analysis highlighting the gaps in pre-analytical and analytical stages. The methods used to quantify HM metabolic hormones (leptin, adiponectin, ghrelin, insulin, obestatin, resistin and apelin) can be classified as immunoassay, immunosensor and chromatography. Immunoassay methods (ELISA and RIA) have been predominantly used in the measurement of these HM hormones. The relative validity parameters of HM hormones analysis are often overlooked in publications, despite the complexity and differences of HM matrix when compared to that of plasma and urine. Therefore, appropriate reports of validation parameters of methodology and instrumentation are crucial for accurate measurements and therefore better understanding of the HM metabolic hormones and their influences on infant outcomes.


Subject(s)
Milk, Human/chemistry , Peptide Hormones/analysis , Biosensing Techniques , Chromatography , Female , Humans , Immunoassay
7.
Adv Neonatal Care ; 20(5): E93-E99, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32868595

ABSTRACT

BACKGROUND: Adequate human milk nutrition is critical for infant growth and neurodevelopment; however, low milk transfer volumes are common when establishing preterm breastfeeding. Despite clinical assessments of milk transfer volumes at the breast being inaccurate, measurement of feed volume via test weighing is rarely carried out either routinely or in cases where infant weight gain is inadequate. PURPOSE: To assess the accuracy of the Preterm Breastfeeding Assessment Tool (PBAT) in determining transfer volumes and examine factors associated with PBAT accuracy. METHODS: Pre/postfeed weights were performed using electronic scales and PBAT scores recorded for 1186 breastfeeds in 60 preterm infants born less than 33/40 and 33 to 39/40 postmenstrual age. Measured milk intake volumes were converted to percent prescribed feed volume and compared with PBAT estimates of milk transfer. RESULTS: The PBAT is accurate in identifying when no milk is transferred at the breast but not in estimating transfer of half or the full prescribed volume (accuracy 26% and 47%, respectively). Wide ranges of transfer volumes (11-75 mL) were observed within and between infants, and for 20% of breastfeeds, no milk was transferred. Preterm Breastfeeding Assessment Tool accuracy decreased with each 1-week increase in birth gestation (odds ratio = 0.82; 95% confidence interval, 0.71-0.94; P = .004). IMPLICATIONS FOR PRACTICE: When establishing breastfeeding, test weighing facilitates adequate nutrition by guiding appropriate complementary feeding. For mothers breastfeeding several times per day in preparation for discharge home, test weighing may offer a useful tool for developing maternal confidence in assessing milk transfer. Preterm Breastfeeding Assessment Tool is inaccurate in assessing preterm infants' milk transfer volumes when breastfeeding. IMPLICATIONS FOR RESEARCH: While studies have typically focused on medically stable infants, test weighing offers a useful tool to examine breastfeeding efficacy and inform nutritional management of preterm infants with complications such as chronic lung and cardiac disease.


Subject(s)
Breast Feeding , Infant, Premature , Weight Gain/physiology , Body Weight , Female , Humans , Infant, Newborn , Infant, Premature/physiology , Male , Milk, Human/physiology , Surveys and Questionnaires , Western Australia
8.
Pediatr Res ; 83(4): 778-783, 2018 04.
Article in English | MEDLINE | ID: mdl-29166375

ABSTRACT

BackgroundPreterm infants' meals typically progress to higher volumes over time. Knowledge of gastric emptying (GE) responses to differing meal volumes may inform enteral feeding management. We examined the effect of meal volume and composition on preterm GE.MethodsForty infants were studied at 33.3±1.4 (29.7-35.6) weeks postmenstrual age when fully enteral fed (target 150 ml/kg/day). Intraindividual comparisons of GE were made for paired meals of 100% and 75% prescribed volume and identical composition of mother's own milk (n=21) and pasteurized donor human milk (n=19). Serial stomach ultrasound images were used to calculate gastric residual volumes (GRVs) and remaining meal proportions (% meal).ResultsGE was faster in the early postprandial period and slowed over time (P<0.001). Reduced volume meals had slower GE rates and lower GRV (P<0.001). Serial postprandial % meal was similar between reduced and full volume meals (P=0.41). Higher milk casein concentration was associated with slower GE (P=0.04). Complete gastric emptying (GRV=0 ml) was more common in infants fed at 3 h intervals compared with those fed every 2 h (P=0.002).ConclusionEarly postprandial GE is more rapid for larger meal volumes. Stable preterm infants may tolerate feeding of a 3 h meal volume at shorter intervals.


Subject(s)
Enteral Nutrition/methods , Gastric Emptying , Milk, Human , Portion Size , Animals , Cattle , Child Nutrition Sciences , Eating , Female , Humans , Infant , Infant, Newborn , Infant, Premature , Linear Models , Male , Meals , Postprandial Period , Stomach/diagnostic imaging , Ultrasonography , Western Australia , Whey Proteins/metabolism
9.
J Pediatr Gastroenterol Nutr ; 60(2): 264-71, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25313848

ABSTRACT

OBJECTIVES: The aim of the present study was to determine whether specific biochemical and energy concentrations influence gastric emptying of unfortified and fortified mother's own milk (MOM) in stable preterm infants, and whether gastric emptying differs between feeds of unfortified MOM and feeds fortified with S-26 or FM 85 human milk fortifier (HMF) when infants are fed the same volume under similar conditions. Influences of infant gestation, age, and weight, and feed characteristics were also explored. METHODS: Stomach volumes of 25 paired unfortified and fortified MOM feeds were monitored prefeed and postfeed delivery and at 30-minute intervals thereafter. For each feed, MOM samples were analyzed to determine concentrations of total protein, casein, whey, carbohydrate, lactose, fat, and energy. Fortified feed compositions were calculated by adding fortifier biochemical and energy concentrations to unfortified MOM concentrations. Ultrasound images were used to calculate infant stomach volumes. Statistical comparisons were made of paired stomach volume measurements. RESULTS: Higher feed concentrations of casein were associated with faster gastric emptying during feed delivery (P = 0.007). When compared with unfortified MOM, S-26 fortified feeds emptied similarly, whereas FM 85 fortified feeds emptied more slowly both during feed delivery and during the postprandial period (P = 0.002, <0.001, respectively). Gastric emptying was slower for 2-hourly feeds compared with that for 3-hourly feeds (P = 0.003) and in supine position compared with that in prone (P = 0.001). CONCLUSIONS: Breast milk composition influences gastric emptying in stable preterm infants, with feeds of higher casein concentration emptying faster during feeding than otherwise equivalent feeds, and FM 85 fortified MOM emptying more slowly than unfortified MOM.


Subject(s)
Food, Fortified , Gastric Emptying , Infant, Premature/physiology , Milk, Human/chemistry , Stomach/anatomy & histology , Caseins/analysis , Caseins/pharmacology , Eating/physiology , Enteral Nutrition , Female , Gastric Emptying/drug effects , Gestational Age , Humans , Infant , Infant, Newborn , Male , Organ Size , Postprandial Period , Prone Position/physiology , Stomach/diagnostic imaging , Supine Position/physiology , Time Factors , Ultrasonography
10.
J Pediatr Gastroenterol Nutr ; 61(1): 125-9, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25729886

ABSTRACT

We evaluated the effects of fortification and composition on gastric emptying and curding in un/fortified pairs of mother's own milk (MOM, n = 17) and pasteurized donor human milk (PDHM, n = 15) in preterm infants. Retained meal proportions (%) and curding were determined from sonography. Immediate and subsequent postprandial % were higher for PDHM (23%, P = 0.026; 15%, P = 0.006) and fortified meals (31.5%; 8.8%, both P < 0.001), whereas higher casein, whey, and lactose concentrations were associated with lower immediate postprandial % (all P < 0.006). Curding did not affect emptying. Influences of fortification, pasteurization, and differing breast milk compositions are small and unlikely implicated in preterm feeding intolerance.


Subject(s)
Food, Fortified , Gastric Emptying , Infant Nutritional Physiological Phenomena , Infant, Premature , Milk, Human , Pasteurization , Caseins/administration & dosage , Female , Gestational Age , Humans , Infant , Infant, Newborn , Lactose/administration & dosage , Male , Mothers , Whey/administration & dosage
11.
BMC Pregnancy Childbirth ; 15: 155, 2015 Jul 26.
Article in English | MEDLINE | ID: mdl-26210318

ABSTRACT

BACKGROUND: Nipple pain is associated with early cessation of breastfeeding and may be caused by high intra-oral vacuum. However identification of high intra-oral vacuum is typically restricted to the research setting. This is the first reported case of an infant with high intra-oral vacuum that was clinically identified through a specific pattern of nipple trauma associated with nipple shield use. Knowledge of clinical signs associated with high intra-oral vacuum may facilitate early recognition of this unusual breastfeeding challenge. CASE PRESENTATION: The mother of an exclusively breastfed 3 month old infant had severe bilateral nipple pain with minimal trauma that persisted from birth. The nipples were not misshapen immediately after breastfeeding and adjustments to infant attachment at the breast did not attenuate the pain. Examination of the infant's oral anatomy was unremarkable with no ankyloglossia present. Microbiological cultures of nipple swabs and breast milk were negative for bacterial and fungal growth, and prescribed antimicrobial treatments did not reduce the nipple pain. Mild blanching and erythema of the nipples were occasionally observed, and were not consistent with nipple vasospasm. Nipple shields were used regularly as they modified the pain, although this resulted in blisters that corresponded with the nipple shield holes. Measurement of infant intra-oral vacuum during breastfeeding confirmed intra-oral vacuum up to 307 % higher than reference values. Breastfeeding gradually became less painful, and after 6 months was completely comfortable. CONCLUSIONS: High intra-oral vacuum is difficult to assess in the clinical setting and is likely an under-reported cause of early weaning that is not well understood. This original case report highlights high intra-oral vacuum as at differential diagnosis to be considered by health professionals when evaluating mothers experiencing strong nipple pain during the initiation of breastfeeding. A clinical screening tool is needed to enable prompt identification of these infants.


Subject(s)
Breast Feeding/adverse effects , Nipples/injuries , Protective Devices/adverse effects , Sucking Behavior , Adult , Breast Feeding/instrumentation , Female , Humans , Infant , Vacuum
12.
J Pediatr Gastroenterol Nutr ; 59(2): 254-63, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24709830

ABSTRACT

OBJECTIVES: The aim of the present study was to determine whether serial gastric volumes and intragastric curding are repeatable within individual preterm infants when given sequential feeds of the same volume and composition. Infant and feeding characteristics that may influence differences in measured gastric volumes, echogenicity, and intragastric curding were also explored. METHODS: Ultrasound images were used to calculate gastric volumes and to rate echogenicity and intragastric curding for 20 infants. A total of 29 paired feeds of the same volume and composition were monitored prefeed and postfeed and at 30-minute intervals thereafter. Statistical comparisons of paired gastric volume measurements and agreement between echogenicity and curding ratings were made for each time point. Analyses of factors that influence discrepancies between volume measurements and between curding ratings were performed. RESULTS: Paired gastric volume measurements were repeatable (intraclass correlation coefficient [ICC] = 0.971, 0.938 < ICC < 0.987). Most (75%) discrepancies were <2 mL and increased over time, although volume differences were small. Overall moderate levels of consistency were observed for ratings of echogenicity (κ = 0.44), and curd presence (κ ≤ 0.65), density (κ = 0.41), and volume (κ = 0.47). Gastric emptying during feed delivery is influenced with infant positioning, fortification of breast milk, and feeding frequency. CONCLUSIONS: For preterm infants serial gastric volumes are repeatable and ratings of intragastric echogenicity and curding are moderately consistent when fed milk of the same volume and composition. Ultrasound has the potential to further explore factors that influence gastric emptying in the preterm infant.


Subject(s)
Gastric Emptying , Infant, Premature , Monitoring, Physiologic/methods , Stomach/diagnostic imaging , Humans , Infant , Infant Formula , Infant, Newborn , Milk, Human , Ultrasonography
13.
Adv Nutr ; 15(1): 100129, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37832920

ABSTRACT

Low milk supply (LMS) poses a significant challenge to exclusive and continued breastfeeding, affecting ∼10% to 15% of mothers. Milk production is intricately regulated by both endocrine and autocrine control mechanisms, with estrogens and progesterone playing pivotal roles in this process. In addition to endogenously produced hormones, external substances capable of interfering with normal hormonal actions, including phytoestrogens, mycoestrogens, synthetic estrogens, and hormonal contraceptives, can influence milk production. The effects of these extrinsic hormones on milk production may vary based on maternal body mass index. This comprehensive review examines the multifaceted causes of LMS, focusing on the involvement of estrogens, progesterone, and related external factors in milk production. Furthermore, it investigates the interplay between hormonal factors and obesity, aiming to elucidate the endocrine mechanisms underlying obesity-associated LMS. Insights from this review provide valuable perspectives for developing interventions to improve milk production and address the challenges associated with LMS.


Subject(s)
Estrogens , Progesterone , Female , Humans , Animals , Progesterone/pharmacology , Estrogens/pharmacology , Milk , Lactation , Obesity
14.
Children (Basel) ; 11(6)2024 May 28.
Article in English | MEDLINE | ID: mdl-38929234

ABSTRACT

The effects of preterm birth, neonatal morbidities and environmental influences on infant sleep development is an important yet under-researched topic, with little known about normative sleep for infants born sick or preterm. The aim of this prospective, observational longitudinal study was to evaluate maternal perceptions and degree of bother with infant sleep behaviours and feeding outcomes across the first 9 months after discharge for sick/preterm infants cared for in the neonatal intensive care unit (NICU) and for healthy term-born infants. This paper reports outcomes for the sick/preterm cohort (I = 94) that were recruited from two NICUs in Perth, Western Australia. Total bother scores were on average 20.2% higher at 9 months than at two weeks post-discharge (p < 0.001). Increased night waking frequency, evening settling duration and crying duration were all positively associated with total bother scores. Maternal confidence scores were negatively associated with maternal bother scores; with each unit increase in confidence, maternal bother decreased by 8.5% (p < 0.001). Covariates such as birth gestation, breastfeeding status and multiple births were not associated with maternal bother. Families may benefit from additional support when experiencing increased night waking frequency and crying and settling durations in the first 9 months after discharge from NICU.

15.
Article in English | MEDLINE | ID: mdl-38541296

ABSTRACT

Breastfeeding exclusivity and duration rates are lower after caesarean birth, yet the factors contributing to these are not well understood. This mixed-methods study used an anonymous online questionnaire to examine the facilitators and barriers to establishing breastfeeding as identified by Australian women after a caesarean birth. Quantitative data were reported using descriptive statistics, and multivariable models were used to determine the factors associated with breastfeeding outcomes including the timing of breastfeeding initiation, birth experience, and commercial infant formula use. Qualitative data were analysed using an inductive thematic analysis. Data were obtained for N = 961 women, of which <50% reported skin-to-skin contact during breastfeeding initiation. The barriers to breastfeeding included aspects of clinical care and reduced mobility, while unrushed care, partner support, and physical help with picking up the baby were helpful. Following a non-elective caesarean birth, women had half the odds of early breastfeeding initiation (OR = 0.50; 95% CI: 0.36, 0.68; p ≤ 0.001) and 10 times the odds to report a negative birth experience (OR = 10.2; 95% CI: 6.88, 15.43; p < 0.001). Commercial milk formula use was higher in primiparous women (OR = 2.16; 95% CI: 1.60, 2.91; p < 0.001) and in those that birthed in a private hospital (OR = 1.67; 95% CI: 1.25, 2.32; p = 0.001). Pain and reduced mobility, as well as conflicting and rushed care, negatively impacted breastfeeding after a caesarean birth, while delayed breastfeeding initiation, higher pain ratings, and negative birth experiences were more common for women that birthed by non-elective caesarean. This study adds valuable insights into the physical, emotional, and clinical care needs of women in establishing breastfeeding after a surgical birth. Clinical staffing and care should be modified to include full access to partner support to meet the specific needs of breastfeeding women after a caesarean birth.


Subject(s)
Breast Feeding , Cesarean Section , Pregnancy , Infant , Female , Humans , Australia , Cognition , Pain
16.
Nutrients ; 16(3)2024 Jan 23.
Article in English | MEDLINE | ID: mdl-38337616

ABSTRACT

Limited attention is given to the efficacy of protocols for the estimation of infant intake of milk components when investigating their impact on infant outcomes. We compared the actual measured intake of human milk components with estimations derived from 15 protocols to determine the most reliable approach for estimating intake of HM leptin, adiponectin, insulin, glucose, and total lipid. Twenty mothers who were 3-5 months postpartum completed a 24 h milk profile study with pre-/post-feed milk samples collection. The true infant intake (control group) based on 24 h milk intake (MI) was compared to estimated infant intakes using concentrations from five sampling protocols that were multiplied by one of true infant MI, considered mean MI (800 mL), or global mean MI (766 mL). The mean measured concentrations of six samples (three sets of pre- and post-feed samples, from morning (06:00-09:00), afternoon (13:00-16:00), and evening (19:00-22:00)) multiplied by the true infant MI, mean considered MI, and global mean MI produced the most accurate estimates of infant intake of these components. Therefore, in the absence of 24 h measurements and sampling, a sampling protocol comprising three sets of pre-/post-feed samples provides the most reliable infant intake estimates of HM leptin, adiponectin, insulin, glucose, and total lipid.


Subject(s)
Leptin , Milk, Human , Infant , Female , Humans , Insulin , Adiponectin , Glucose , Breast Feeding , Body Mass Index , Lipids
17.
J Pediatr Gastroenterol Nutr ; 57(6): 741-9, 2013 Dec.
Article in English | MEDLINE | ID: mdl-23969536

ABSTRACT

OBJECTIVES: The aim of this study was to validate 4 sonographic methods of estimating stomach volume for the purpose of monitoring changes in gastric volume over time and to describe the echogenic characteristics of milk feeds. METHODS: Twenty-four infants were monitored during a single intragastric tube feed, with 2 ultrasound images of the entire stomach and an image of the antral cross-sectional area (ACSA) before, during, and after the feed. Raw measurements, 3 stomach volume calculations, and ACSA were tested for intra- and interrater agreement. Calculated stomach volumes and ACSA were compared with delivered feed volumes, and characteristics of stomach image echogenicity graded at each time point. RESULTS: Spheroid calculation of stomach volume was the most reliable and valid measure of stomach volume. Fortified breast milk feeds were more echogenic than unfortified breast milk feeds. Residual stomach volumes (median 2.12 mL, range 0.59-9.27 mL) were identified in 18 of 24 infants. CONCLUSIONS: Direct ultrasound stomach measurement (spheroid) will provide a useful research tool and a potential clinical tool for assessing gastric emptying and feeding intolerance in preterm infants.


Subject(s)
Enteral Nutrition , Gastric Emptying , Infant, Premature , Milk, Human , Monitoring, Physiologic/methods , Stomach/diagnostic imaging , Animals , Food, Fortified , Humans , Infant , Infant, Newborn , Milk , Monitoring, Physiologic/standards , Pyloric Antrum/diagnostic imaging , Reproducibility of Results , Ultrasonography
18.
Nutrients ; 15(17)2023 Aug 25.
Article in English | MEDLINE | ID: mdl-37686759

ABSTRACT

There is an inadequate understanding of the daily variations in hormones and macronutrients in human milk (HM), and sample collection protocols vary considerably from study to study. To investigate changes in these milk components across 24 h, 22 lactating women collected small milk samples before and after each breastfeed or expression from each breast. Test weighing was used to determine the volume of HM consumed in each feed. The concentrations of leptin, adiponectin, insulin, fat, and glucose were measured, and the intakes were calculated. A linear mixed model was fitted to assess within-feed and circadian variation in HM feed volume and concentration, and intakes of several components. The average infant intake of HM was 879 g/24 h. Significantly higher pre-feed concentrations were found for adiponectin and glucose and lower post-feed concentrations were found for insulin and fat. Significant circadian rhythms were displayed for leptin, adiponectin, insulin, glucose (both concentration and intake), fat concentration, and milk volume. These findings demonstrate the necessity for setting up standardised and rigorous sampling procedures that consider both within-feed and circadian variations in HM components to gain a more precise understanding of the impacts of these components on infant health, growth and development.


Subject(s)
Leptin , Milk, Human , Infant , Humans , Female , Adiponectin , Lactation , Insulin , Nutrients , Glucose
19.
Nutrients ; 15(10)2023 May 18.
Article in English | MEDLINE | ID: mdl-37242254

ABSTRACT

Human milk provides all of the elements necessary for infant growth and development. Previous studies have reported associations between breastfeeding and a reduced risk of developing obesity and late-onset metabolic disorders; however, the underlying mechanisms are poorly understood. Recently, intakes of human milk components have been associated with infant body composition, which is likely partially implicated in the reduced risk of developing childhood obesity among breastfed infants. In this systematic review, we searched electronic bibliographic databases for studies that explored relationships between the 24 h intakes of human milk macronutrients and bioactive components and infant body composition and/or growth parameters. Of 13 eligible studies, 10 assessed relationships of infant body composition and growth outcomes with human milk macronutrients, while 8 studies assessed relationships with human milk bioactive components. Significant time-dependent relationships with infant anthropometrics and body composition were found for intakes and no relationships for concentrations of several human milk components, such as lactose, total protein, and human milk oligosaccharides, suggesting that measuring concentrations of human milk components without quantifying the intake by the infant may provide a limited understanding. Future studies investigating the effect of human milk components on infant growth and body composition outcomes should consider measuring the actual intake of components and employ standardised methods for measuring milk intake.


Subject(s)
Breast Feeding , Pediatric Obesity , Child , Female , Infant , Humans , Milk, Human , Body Composition , Infant Nutritional Physiological Phenomena
20.
Life (Basel) ; 12(4)2022 Mar 28.
Article in English | MEDLINE | ID: mdl-35454985

ABSTRACT

We investigated associations between intakes of human milk (HM) components (macronutrients and biologically active molecules) and regional fat depots development in healthy term infants (n = 20) across the first year of lactation. Infant limb (mid-arm and mid-thigh) lean and fat areas were assessed by ultrasound imaging at 2, 5, 9 and 12 months of age. Concentrations of HM total protein, whey protein, casein, adiponectin, leptin, lysozyme, lactoferrin, secretory IGA, total carbohydrates, lactose, HM oligosaccharides (total HMO, calculated) and infant 24-h milk intake were measured, and infant calculated daily intakes (CDI) of HM components were determined. This pilot study shows higher 24-h milk intake was associated with a larger mid-arm fat area (p = 0.024), higher breastfeeding frequency was associated with larger mid-arm (p = 0.008) and mid-thigh (p < 0.001) fat areas. Lysozyme (p = 0.001) and HMO CDI (p = 0.004) were time-dependently associated with the mid-arm fat area. Intakes of HM components and breastfeeding parameters may modulate infant limb fat depots development during the first year of age and potentially promote favorable developmental programming of infant body composition; however, further studies are needed to confirm these findings.

SELECTION OF CITATIONS
SEARCH DETAIL