Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
Appl Opt ; 62(16): E119-E124, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37706908

ABSTRACT

Fiber Bragg grating (FBG) sensors have been widely applied for structural health monitoring applications. In some applications, remote bonding of the optical fiber is applied, where ultrasonic waves are coupled from the structure to the optical fiber and propagated along the fiber to the FBG sensor. The distance that this signal can propagate along the optical fiber without decaying below a threshold value can be critical to the area of the structure that can be monitored per sensor. In this paper, we develop a method to measure the acoustic mode attenuation of fiber waveguides based on laser Doppler vibrometry (LDV) that is independent of the fiber type. In order to validate the method, we compare attenuation measurements on single-mode optical fibers using both the LDV and FBG sensor methods. Once the method is validated, experimental measurements of different coated and uncoated optical fibers are performed to quantify the role of the fiber diameter on the attenuation coefficient. As the radius of the waveguide decreases, the signal attenuation increases exponentially.

2.
Appl Opt ; 62(16): OFS1, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37706914

ABSTRACT

This special issue contains a collection of papers on optical fiber sensors that were originally presented and published in a more succinct form in conjunction with the 27th International Conference on Optical Fiber Sensors (OFS) held in Alexandria, Virginia, United States, from 29th August to 2nd September, 2022.

3.
Sensors (Basel) ; 22(11)2022 May 30.
Article in English | MEDLINE | ID: mdl-35684783

ABSTRACT

Optical fibers were previously demonstrated to propagate and detect acoustic modes that were converted from Lamb waves for structural health-monitoring applications; typically, a fiber Bragg grating sensor in the optical fiber is used to detect acoustic modes. Acoustic modes can transfer from one fiber to another through a simple adhesive bond coupler, preserving the waveform of the acoustic mode. This paper experimentally investigates the coherence of acoustic waves through the adhesive coupler, using a fiber ring resonator (FRR) configuration. This configuration was chosen because the wave coupled to the second fiber interferes with the original wave after it encircles the fiber ring. We performed this experiment using different geometries of optical fibers in the ring, including a standard single-mode optical fiber, a hollow silica capillary tube, and a large-diameter multi-mode fiber. The results demonstrate that the acoustic wave, when transferring through an adhesive coupler, interferes coherently even when the main and ring fibers are of different types. Finally, we demonstrate that the FRR can be applied for sensing applications by measuring the mode attenuations in the ring due to a changing external environment (water-level sensing) and measuring the optical-path length change in the ring (temperature sensing).

4.
Sensors (Basel) ; 22(21)2022 Nov 02.
Article in English | MEDLINE | ID: mdl-36366123

ABSTRACT

This paper demonstrates that a graded-index (GRIN) phononic lens, combined with a channel waveguide, can focus anti-symmetric Lamb waves for extraction by a detector with strong directional sensitivity. Guided ultrasonic wave inspection is commonly applied for structural health monitoring applications; however, obtaining sufficient signal amplitude is a challenge. In addition, fiber Bragg grating (FBG) sensors have strong directional sensitivity. We fabricate the GRIN structure, followed by a channel waveguide starting at the focal point, using a commercial 3D printer and mount it on a thin aluminum plate. We characterize the focusing of the A0 mode Lamb wave in the plate, traveling across the GRIN lens using 3D laser Doppler vibrometry. We also measure the extraction of focused energy using an FBG sensor, examining the optimal sensor bond location and bond length in the channel of the waveguide for maximum signal extraction. The measured amplification of the ultrasound signal is compared to theoretical predictions. The results demonstrate that significant amplification of the waveform is achieved and that selecting the location of the FBG sensor in the channel is critical to optimizing the amplification.

5.
Sensors (Basel) ; 22(16)2022 Aug 11.
Article in English | MEDLINE | ID: mdl-36015760

ABSTRACT

Structural health monitoring (SHM) systems may allow a reduction in maintenance costs and extend the lifetime of the structure. As a result, they are of interest to the research community. Ideally, the SHM methods should be low cost, while being able to detect and localize small levels of damage reliably and accurately. The fiber Bragg grating (FBG) sensors are light in weight, insensitive to electric and magnetic fields, and can be embedded. The edge filtering configuration for transduction allows the use of FBG for guided wave (GW) sensing. This sensitivity may be further enhanced through their application in the remote bonded configuration. This paper provides a proof-of-concept for the use of remotely bonded FBG for damage localization. In order to improve the computational efficiency, a particle swarm optimization (PSO) based algorithm is developed. The PSO allows a significant improvement in the computation time which makes it better suited for real-time damage localization. The proposed objective function is based on the exponential elliptical approach. First, the suitability of the PSO for damage localization is shown. Then the performance of the chosen objective function is compared with the brute-force algorithm as well as other objective functions found in the literature. The methodology is employed on a simple aluminum plate. The results indicate that indeed the objective function along with the PSO is suitable for damage localization. Also as the objective function is developed taking into consideration the specific challenges with the use of FBG sensors, performs better than the other objective functions as well as the brute force algorithm.

6.
Sensors (Basel) ; 22(20)2022 Oct 20.
Article in English | MEDLINE | ID: mdl-36298350

ABSTRACT

We applied a polarization filter array and high-speed camera to the imaging of biological tissues during large, dynamic deformations at 7000 frames per second. The results are compared to previous measurements of similar specimens using a rotating polarizer imaging system. The polarization filter eliminates motion blur and temporal bias from the reconstructed collagen fiber alignment angle and retardation images. The polarization imaging configuration dose pose additional challenges due to the need for calibration of the polarization filter array for a given sample in the same lighting conditions as during the measurement.


Subject(s)
Lighting , Skin , Motion , Calibration , Collagen
7.
Appl Opt ; 60(36): 11042-11049, 2021 Dec 20.
Article in English | MEDLINE | ID: mdl-35201092

ABSTRACT

In this study, we investigate coupling of acoustic guided waves from different types of input fibers, through a bonded coupler, to an optical fiber. These acoustic waves can then be detected with conventional fiber Bragg gratings (FBGs). The input waves are measured using a high-resolution 3D laser Doppler vibrometer, and the output waves in the optical fiber are measured using an FBG. We demonstrate that the wave coupling between two waveguides varies with the cross-sectional area and the modulus of elasticity of the fibers.

8.
Sensors (Basel) ; 21(21)2021 Nov 04.
Article in English | MEDLINE | ID: mdl-34770651

ABSTRACT

Guided waves (GW) and acoustic emission (AE) -based structural health monitoring (SHM) have widespread applications in structures, as the monitoring of an entire structure is possible with a limited number of sensors. Optical fiber-based sensors offer several advantages, such as their low weight, small size, ability to be embedded, and immunity to electro-magnetic interference. Therefore, they have long been regarded as an ideal sensing solution for SHM. In this review, the different optical fiber technologies used for ultrasonic sensing are discussed in detail. Special attention has been given to the new developments in the use of FBG sensors for ultrasonic measurements, as they are the most promising and widely used of the sensors. The paper highlights the physics of the wave coupling to the optical fiber and explains the different phenomena such as directional sensitivity and directional coupling of the wave. Applications of the different sensors in real SHM applications have also been discussed. Finally, the review identifies the encouraging trends and future areas where the field is expected to develop.


Subject(s)
Optical Fibers , Ultrasonics , Fiber Optic Technology
9.
Appl Opt ; 56(25): 7262-7268, 2017 Sep 01.
Article in English | MEDLINE | ID: mdl-29047989

ABSTRACT

Fiber Bragg grating (FBG) sensors are typically spot-bonded onto the surface of a structure to detect ultrasonic waves in laboratory demonstrations. However, to protect the rest of the optical fiber from any environmental damage during real applications, bonding the entire length of fiber, called continuous bonding, is commonly done. In this paper, we investigate the impact of continuously bonding FBGs on the measured Lamb wave signal. In theory, the ultrasonic wave signal can bi-directionally transfer between the optical fiber and the plate at any adhered location, which could potentially produce output signal distortion for the continuous bonding case. Therefore, an experiment is performed to investigate the plate-to-fiber and fiber-to-plate signal transfer, from which the signal coupling coefficient of each case is theoretically estimated based on the experimental data. We demonstrate that the two coupling coefficients are comparable, with the plate-to-fiber case approximately 19% larger than the fiber-to-plate case. Finally, the signal waveform and arrival time of the output FBG responses are compared between the continuous and spot bonding cases. The results indicate that the resulting Lamb wave signal output is only that directly detected at the FBG location; however, a slight difference in signal waveform is observed between the two bonding configurations. This paper demonstrates the practicality of using continuously bonded FBGs for ultrasonic wave detection in structural health monitoring (SHM) applications.

10.
Appl Opt ; 55(21): 5564-9, 2016 Jul 20.
Article in English | MEDLINE | ID: mdl-27463905

ABSTRACT

Networks of fiber Bragg grating (FBG) sensors can serve as structural health monitoring systems for large-scale structures based on the collection of ultrasonic waves. The demodulation of structural Lamb waves using FBG sensors requires a high signal-to-noise ratio because the Lamb waves are of low amplitudes. This paper compares the signal transfer amplitudes between two adhesive mounting configurations for an FBG to detect Lamb waves propagating in an aluminum plate: a directly bonded FBG and a remotely bonded FBG. In the directly bonded FBG case, the Lamb waves create in-plane and out-of-plane displacements, which are transferred through the adhesive bond and detected by the FBG sensor. In the remotely bonded FBG case, the Lamb waves are converted into longitudinal and flexural traveling waves in the optical fiber at the adhesive bond, which propagate through the optical fiber and are detected by the FBG sensor. A theoretical prediction of overall signal attenuation also is performed, which is the combination of material attenuation in the plate and optical fiber and attenuation due to wave spreading in the plate. The experimental results demonstrate that remote bonding of the FBG significantly increases the signal amplitude measured by the FBG.

11.
Appl Opt ; 55(25): 7179-85, 2016 Sep 01.
Article in English | MEDLINE | ID: mdl-27607299

ABSTRACT

The development and validation of a high-speed, full-spectrum measurement technique is described for fiber Bragg grating (FBG) sensors. A FBG is surface-mounted to a split-Hopkinson tensile bar specimen to induce high strain rates. The high strain gradients and large strains that indicate material failure are analyzed under high strain rates up to 500 s-1. The FBG is interrogated using a high-speed full-spectrum solid-state interrogator with a repetition rate of 100 kHz. The captured deformed spectra are analyzed for strain gradients using a default interior point algorithm in combination with the modified transfer matrix approach. This paper shows that by using high-speed full-spectrum interrogation of an FBG and the modified transfer matrix method, highly localized strain gradients and discontinuities can be measured without a direct line of sight.

12.
Adv Mater ; 35(22): e2211286, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36796104

ABSTRACT

Acting like thermal resistances, ferroelectric domain walls can be manipulated to realize dynamic modulation of thermal conductivity (k), which is essential for developing novel phononic circuits. Despite the interest, little attention has been paid to achieving room-temperature thermal modulation in bulk materials due to challenges in obtaining a high thermal conductivity switching ratio (khigh /klow ), particularly in commercially viable materials. Here, room-temperature thermal modulation in 2.5 mm-thick Pb(Mg1/3 Nb2/3 )O3 -xPbTiO3 (PMN-xPT) single crystals is demonstrated. With the use of advanced poling conditions, assisted by the systematic study on composition and orientation dependence of PMN-xPT, a range of thermal conductivity switching ratios with a maximum of ≈1.27 is observed. Simultaneous measurements of piezoelectric coefficient (d33 ) to characterize the poling state, domain wall density using polarized light microscopy (PLM), and birefringence change using quantitative PLM reveal that compared to the unpoled state, the domain wall density at intermediate poling states (0< d33

13.
Bioengineering (Basel) ; 10(5)2023 May 17.
Article in English | MEDLINE | ID: mdl-37237672

ABSTRACT

The vocal folds (VFs) are constantly exposed to mechanical stimulation leading to changes in biomechanical properties, structure, and composition. The development of long-term strategies for VF treatment depends on the characterization of related cells, biomaterials, or engineered tissues in a controlled mechanical environment. Our aim was to design, develop, and characterize a scalable and high-throughput platform that mimics the mechanical microenvironment of the VFs in vitro. The platform consists of a 24-well plate fitted with a flexible membrane atop a waveguide equipped with piezoelectric speakers which allows for cells to be exposed to various phonatory stimuli. The displacements of the flexible membrane were characterized via Laser Doppler Vibrometry (LDV). Human VF fibroblasts and mesenchymal stem cells were seeded, exposed to various vibratory regimes, and the expression of pro-fibrotic and pro-inflammatory genes was analyzed. Compared to current bioreactor designs, the platform developed in this study can incorporate commercial assay formats ranging from 6- to 96-well plates which represents a significant improvement in scalability. This platform is modular and allows for tunable frequency regimes.

14.
J Control Release ; 359: 287-301, 2023 07.
Article in English | MEDLINE | ID: mdl-37301267

ABSTRACT

Although nebulizers have been developed for delivery of small molecules in human patients, no tunable device has been purpose-built for targeted delivery of modern large molecule and temperature-sensitive therapeutics to mice. Mice are used most of all species in biomedical research and have the highest number of induced models for human-relevant diseases and transgene models. Regulatory approval of large molecule therapeutics, including antibody therapies and modified RNA highlight the need for quantifiable dose delivery in mice to model human delivery, proof-of-concept studies, efficacy, and dose-response. To this end, we developed and characterized a tunable nebulization system composed of an ultrasonic transducer equipped with a mesh nebulizer fitted with a silicone restrictor plate modification to control the nebulization rate. We have identified the elements of design that influence the most critical factors to targeted delivery to the deep lungs of BALB/c mice. By comparing an in silico model of the mouse lung with experimental data, we were able to optimize and confirm the targeted delivery of over 99% of the initial volume to the deep portions of the mouse lung. The resulting nebulizer system provides targeted lung delivery efficiency far exceeding conventional nebulizers preventing waste of expensive biologics and large molecules during proof-of-concept and pre-clinical experiments involving mice. (Word Count =207).


Subject(s)
Lung , Nebulizers and Vaporizers , Humans , Animals , Mice , Aerosols , Administration, Inhalation , Drug Delivery Systems/methods , Equipment Design
15.
Appl Opt ; 51(28): 6886-95, 2012 Oct 01.
Article in English | MEDLINE | ID: mdl-23033107

ABSTRACT

We demonstrate a polymer waveguide, Fabry-Perot interferometer strain sensor fabricated through a self-writing process in a photopolymerizable resin bath between two silica optical fibers. The measurable strain range is extended through sensor self-repair and strain measurements are demonstrated up to 150% applied tensile strain. The sensor fabrication and repair is performed in the ultraviolet wavelength range, while the sensor interrogation is performed in the near-infrared wavelength range. A hybrid sensor is fabricated by splicing a short segment of multimode optical fiber to the input single-mode optical fiber. The hybrid sensor provides the high quality of waveguide fabrication previously demonstrated through self-writing between multimode optical fibers with the high fringe visibility of single-mode propagation. The peak frequency shift of the reflected spectrum Fabry-Perot sensor is extremely linear with applied strain for the hybrid sensor, with a sensitivity of 2.3×10(-3) per nanometer per percent strain. The calibrated peak frequency shift with applied strain is the same for both the original sensor and the repaired sensor; therefore, the fact that the sensor has self-repaired does not need to be known. Additionally, this calibration is the same between multiple sensor fabrications. In contrast to a conventional air gap Fabry-Perot cavity sensor, no decrease in the fringe visibility is observed over the measurable strain range.

16.
Math Biosci ; 327: 108411, 2020 09.
Article in English | MEDLINE | ID: mdl-32623027

ABSTRACT

Tendon-to-bone insertion provides a gradual transition from soft tendon to hard bone tissue, functioning to alleviate stress concentrations at the junction of these tissues. Such macroscopic mechanical properties are achieved due to the internal structure in which collagen fibers and mineralization levels are key ingredients. We develop a structural-based model of tendon-to-bone insertion incorporating such details as fiber preferred orientation, fiber directional dispersion, mineralization level, and their inhomogeneous spatial distribution. A python script is developed to alter the tapered tendon-bone transition zone and to provide spatial grading of material properties, which may be rather complex as experiments suggest. A simple linear interpolation between tendon and bone material properties is first used to describe the graded property within the insertion region. Stress distributions are obtained and compared for spatially graded and various piece-wise materials properties. It is observed that spatial grading results in more smooth stress distributions and significantly reduces maximum stresses. The geometry of the tissue model is optimized by minimizing the peak stress to mimic in-vivo tissue remodeling. The in-silico elastic models constructed in this work are verified and modified by comparing to our in-situ biaxial mechanical testing results, thereby serving as translational tools for accurately predicting the material behavior of the tendon-to-bone insertions. This model will be useful for understanding how tendon-to-bone insertion develops during tissue remodeling, as well as for developing orthopedic implants.


Subject(s)
Bone and Bones/anatomy & histology , Bone and Bones/physiology , Models, Biological , Tendons/anatomy & histology , Tendons/physiology , Animals , Anisotropy , Biomechanical Phenomena , Collagen/physiology , Collagen/ultrastructure , Computer Simulation , Female , Finite Element Analysis , Mathematical Concepts , Models, Anatomic , Nonlinear Dynamics , Stress, Mechanical , Swine , Tensile Strength
17.
Math Biosci ; 308: 1-7, 2019 02.
Article in English | MEDLINE | ID: mdl-30537481

ABSTRACT

Tendon-to-bone insertion tissues may be considered as functionally-graded connective tissues, providing a gradual transition from soft tendon to hard bone tissue, and functioning to alleviate stress concentrations at the junction of these tissues. The tendon-to-bone insertion tissues demonstrate pronounced viscoelastic behavior, like many other biological tissues, and are designed by the nature to alleviate stress at physiological load rates and strains states. In this paper we present experimental data showing that under biaxial tension tendon-to-bone insertion demonstrates rate-dependent behavior and that stress-strain curves for the in-plane components of stress and strain become less steep when strain rate is increased, contrary to a typical viscoelastic behavior, where the opposite trend is observed. Such behavior may indicate the existence of a protective viscoelastic mechanism reducing stress and strain during a sudden increase in mechanical loading, known to exist in some biological tissues. The main purpose of the paper is to show that such viscoelastic stress reduction indeed possible and is thermodynamically consistent. We, therefore, propose an anisotropic viscoelasticity model for finite strain. We identify the range of parameters for this model which yield negative viscoelastic contribution into in-plane stress under biaxial state of strain and simultaneously satisfy requirements of thermodynamics. We also find optimal parameters maximizing the observed protective viscoelastic effect for this particular state of strain. This model will be useful for testing and describing viscoelastic materials and for developing interfaces for dissimilar materials, considering rate effect and multiaxial loadings.


Subject(s)
Bone and Bones , Models, Biological , Stress, Mechanical , Tendons , Anisotropy , Elasticity , Thermodynamics , Viscosity
18.
Pediatrics ; 142(5)2018 11.
Article in English | MEDLINE | ID: mdl-30282783

ABSTRACT

BACKGROUND AND OBJECTIVES: The prevalence of mental health problems among adolescents in the United States is a major public health concern. However, the uptake of mental health treatment is low. Integrating behavioral health into primary care is 1 research-informed strategy to increase engagement in treatment. Facilitators of and barriers to implementation of integrated behavioral health in a pediatric primary care setting are not well delineated. METHODS: We examined the effectiveness of 2 mental health quality improvement strategies: an electronic referral and a social work follow-up protocol. We analyzed the following measures: uptake rate of first mental health appointments, overall use of mental health appointments, and first and overall mental health appointment show rate. RESULTS: Overall use rate improved after implementation of electronic referral, with 13 consecutive points above the median. First appointment show rates improved with a special cause run occurring after adding social work students to the mental health quality improvement team. First appointment show rate improved from a monthly average of 51% (November 2014 to March 2016) to 78% (April 2016 to December 2016). Use rate improved initially with increased efforts in assisting patients with scheduling; show rate improved more slowly after an emphasis on scheduling patients exhibiting treatment readiness. CONCLUSIONS: Findings suggest that a number of facilitators can increase the effective use of mental health services in an integrated adolescent clinical setting. These include an electronic referral through a shared electronic health record, multidisciplinary collaboration, and care management by social workers equipped with a variety of clinical and care coordination skills.


Subject(s)
Health Services Accessibility/standards , Mental Health Services/standards , Patient Acceptance of Health Care/statistics & numerical data , Quality Improvement/statistics & numerical data , Adolescent , Adult , Appointments and Schedules , Child , Humans , Referral and Consultation/standards , Social Work/standards , Young Adult
19.
J Biomed Opt ; 23(11): 1-11, 2018 11.
Article in English | MEDLINE | ID: mdl-30392198

ABSTRACT

A high-speed polarization imaging instrument is demonstrated to be capable of measuring the collagen fiber alignment orientation and alignment strength during high-displacement rate dynamic loading at acquisition rates up to 10 kHz. The implementation of a high-speed rotating quarter wave plate and high-speed camera in the imaging system allows a minimum measurement acquisition time of 6 ms. Sliced tendon-to-bone insertion samples are loaded using a modified drop tower with an average maximum displacement rate of 1.25 m / s, and imaged using a high-speed polarization imaging instrument. The generated collagen fiber alignment angle and strength maps indicate the localized deformation and fiber realignment in tendon-to-bone samples during dynamic loading. The results demonstrate a viable experimental method to monitor collagen fiber realignment in biological tissue under high-displacement rate dynamic loading.


Subject(s)
Bone and Bones/diagnostic imaging , Collagen/chemistry , Image Processing, Computer-Assisted/methods , Microscopy, Polarization/methods , Tendons/diagnostic imaging , Algorithms , Animals , Equipment Design , Forelimb/diagnostic imaging , Microscopy, Polarization/instrumentation , Swine
20.
Bioinspir Biomim ; 13(5): 056013, 2018 08 02.
Article in English | MEDLINE | ID: mdl-30024386

ABSTRACT

This paper looks to the natural world for solutions to many of the challenges associated with the design of fixed-wing cross-domain vehicles. One example is the common murre, a seabird that flies from nesting locations to feeding areas, dives underwater to catch prey and returns. This hunting expedition provides an outline of a possible mission for a cross-domain vehicle. While the challenges of cross-domain vehicles are many, the focus of this paper was on buoyancy management and propulsion. Potential solutions to each challenge, inspired by multiple animals that cross between aerial and underwater domains, are investigated. From these solutions, three design concepts are considered, a quadrotor/fixed-wing hybrid, a vertical takeoff and landing (VTOL) tailsitter aircraft, and a waterjet-assisted takeoff vehicle. A comparison was made between the capability of each concept to complete two missions based on the common murres' hunting expedition. As a result of this comparison, the VTOL tailsitter design was selected for further study. In-depth design was conducted and a prototype vehicle was built. The completed vehicle prototype successfully conducted submerged operation as well as four air flights. Flights consisted of egress from water, flight in air, ingress into water in each flight, and water locomotion. A total of 11 min, 23 s of flight time was recorded as well as underwater swims down to 12 ft (3.7 m) below the surface.


Subject(s)
Birds/physiology , Equipment Design/methods , Flight, Animal/physiology , Wings, Animal/physiology , Animals , Diving/physiology , Locomotion/physiology , Swimming/physiology , Water/physiology
SELECTION OF CITATIONS
SEARCH DETAIL