Circulation ; 149(1): e1-e156, 2024 01 02.
Article in English | MEDLINE | ID: mdl-38033089

ABSTRACT

AIM: The "2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation" provides recommendations to guide clinicians in the treatment of patients with atrial fibrillation. METHODS: A comprehensive literature search was conducted from May 12, 2022, to November 3, 2022, encompassing studies, reviews, and other evidence conducted on human subjects that were published in English from PubMed, EMBASE, the Cochrane Library, the Agency for Healthcare Research and Quality, and other selected databases relevant to this guideline. Additional relevant studies, published through November 2022, during the guideline writing process, were also considered by the writing committee and added to the evidence tables, where appropriate. STRUCTURE: Atrial fibrillation is the most sustained common arrhythmia, and its incidence and prevalence are increasing in the United States and globally. Recommendations from the "2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation" and the "2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation" have been updated with new evidence to guide clinicians. In addition, new recommendations addressing atrial fibrillation and thromboembolic risk assessment, anticoagulation, left atrial appendage occlusion, atrial fibrillation catheter or surgical ablation, and risk factor modification and atrial fibrillation prevention have been developed.


Subject(s)
Atrial Fibrillation , Cardiology , Thromboembolism , Humans , American Heart Association , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Risk Factors , United States/epidemiology
2.
Eur Heart J ; 45(14): 1241-1251, 2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38426911

ABSTRACT

BACKGROUND AND AIMS: Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. METHODS: All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine-Gray competing risk models. RESULTS: 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6-64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%-5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36-.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%-6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). CONCLUSIONS: Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.


Subject(s)
Arrhythmias, Cardiac , Pacemaker, Artificial , Humans , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/etiology , Treatment Outcome , Equipment Design , Pacemaker, Artificial/adverse effects , Registries , Cardiac Pacing, Artificial/adverse effects
3.
Lancet ; 402(10396): 118-128, 2023 07 08.
Article in English | MEDLINE | ID: mdl-37331368

ABSTRACT

BACKGROUND: Etripamil is a fast-acting, intranasally administered calcium-channel blocker in development for on-demand therapy outside a health-care setting for paroxysmal supraventricular tachycardia. We aimed to evaluate the efficacy and safety of etripamil 70 mg nasal spray using a symptom-prompted, repeat-dose regimen for acute conversion of atrioventricular-nodal-dependent paroxysmal supraventricular tachycardia to sinus rhythm within 30 min. METHODS: RAPID was a multicentre, randomised, placebo-controlled, event-driven trial, conducted at 160 sites in North America and Europe as part 2 of the NODE-301 study. Eligible patients were aged at least 18 years and had a history of paroxysmal supraventricular tachycardia with sustained, symptomatic episodes (≥20 min) as documented by electrocardiogram. Patients were administered two test doses of intranasal etripamil (each 70 mg, 10 min apart) during sinus rhythm; those who tolerated the test doses were randomly assigned (1:1) using an interactive response technology system to receive either etripamil or placebo. Prompted by symptoms of paroxysmal supraventricular tachycardia, patients self-administered a first dose of intranasal 70 mg etripamil or placebo and, if symptoms persisted beyond 10 min, a repeat dose. Continuously recorded electrocardiographic data were adjudicated, by individuals masked to patient assignment, for the primary endpoint of time to conversion of paroxysmal supraventricular tachycardia to sinus rhythm for at least 30 s within 30 min after the first dose, which was measured in all patients who administered blinded study drug for a confirmed atrioventricular-nodal-dependent event. Safety outcomes were assessed in all patients who self-administered blinded study drug for an episode of perceived paroxysmal supraventricular tachycardia. This trial is registered at ClinicalTrials.gov, NCT03464019, and is complete. FINDINGS: Between Oct 13, 2020, and July 20, 2022, among 692 patients randomly assigned, 184 (99 from the etripamil group and 85 from the placebo group) self-administered study drug for atrioventricular-nodal-dependent paroxysmal supraventricular tachycardia, with diagnosis and timing confirmed. Kaplan-Meier estimates of conversion rates by 30 min were 64% (63/99) with etripamil and 31% (26/85) with placebo (hazard ratio 2·62; 95% CI 1·66-4·15; p<0·0001). Median time to conversion was 17·2 min (95% CI 13·4-26·5) with the etripamil regimen versus 53·5 min (38·7-87·3) with placebo. Prespecified sensitivity analyses of the primary assessment were conducted to test robustness, yielding supporting results. Treatment-emergent adverse events occurred in 68 (50%) of 99 patients treated with etripamil and 12 (11%) of 85 patients in the placebo group, most of which were located at the administration site and were mild or moderate, and all of which were transient and resolved without intervention. Adverse events occurring in at least 5% of patients treated with etripamil were nasal discomfort (23%), nasal congestion (13%), and rhinorrhea (9%). No serious etripamil-related adverse events or deaths were reported. INTERPRETATION: Using a symptom-prompted, self-administered, initial and optional-repeat-dosing regimen, intranasal etripamil was well tolerated, safe, and superior to placebo for the rapid conversion of atrioventricular-nodal-dependent paroxysmal supraventricular tachycardia to sinus rhythm. This approach could empower patients to treat paroxysmal supraventricular tachycardia themselves outside of a health-care setting, and has the potential to reduce the need for additional medical interventions, such as intravenous medications given in an acute-care setting. FUNDING: Milestone Pharmaceuticals.


Subject(s)
Tachycardia, Paroxysmal , Tachycardia, Supraventricular , Tachycardia, Ventricular , Humans , Adolescent , Adult , Tachycardia, Supraventricular/drug therapy , Tachycardia, Paroxysmal/drug therapy , Benzoates/therapeutic use , Double-Blind Method
4.
Am Heart J ; 270: 103-116, 2024 04.
Article in English | MEDLINE | ID: mdl-38307365

ABSTRACT

BACKGROUND: The finding of unexpected variations in treatment benefits by geographic region in international clinical trials raises complex questions about the interpretation and generalizability of trial findings. We observed such geographical variations in outcome and in the effectiveness of atrial fibrillation (AF) ablation versus drug therapy in the Catheter Ablation vs Antiarrhythmic Drug Therapy for Atrial Fibrillation (CABANA) trial. This paper describes these differences and investigates potential causes. METHODS: The examination of treatment effects by geographic region was a prespecified analysis. CABANA enrolled patients from 10 countries, with 1,285 patients at 85 North American (NA) sites and 919 at 41 non-NA sites. The primary endpoint was a composite of death, disabling stroke, serious bleeding, or cardiac arrest. Death and first atrial fibrillation recurrence were secondary endpoints. RESULTS: At least 1 primary endpoint event occurred in 157 patients (12.2%) from NA and 33 (3.6%) from non-NA sites over a median 54.9 and 40.5 months of follow-up, respectively (NA/non-NA adjusted hazard ratio (HR) 2.18, 95% confidence interval (CI) 1.48-3.21, P < .001). In NA patients, 78 events occurred in the ablation and 79 in the drug arm, (HR 0.91, 95% CI 0.66, 1.24) while 11 and 22 events occurred in non-NA patients (HR 0.51, 95% CI 0.25,1.05, interaction P = .154). Death occurred in 53 ablation and 51 drug therapy patients in the NA group (HR 0.96, 95% CI 0.65,1.42) and in 5 ablation and 16 drug therapy patients in the non-NA group (HR 0.32, 95% CI 0.12,0.86, interaction P = .044). Adjusting for baseline regional differences or prognostic risk variables did not account for the regional differences in treatment effects. Atrial fibrillation recurrence was reduced by ablation in both regions (NA: HR 0.54, 95% CI 0.46, 0.63; non-NA: HR 0.44, 95% CI 0.30, 0.64, interaction P = .322). CONCLUSIONS: In CABANA, primary outcome events occurred significantly more often in the NA group but assignment to ablation significantly reduced all-cause mortality in the non-NA group only. These differences were not explained by regional variations in procedure effectiveness, safety, or patient characteristics. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0091150; https://clinicaltrials.gov/study/NCT00911508.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Arrest , Stroke , Humans , Atrial Fibrillation/drug therapy , Atrial Fibrillation/surgery , Anti-Arrhythmia Agents/therapeutic use , Stroke/etiology , Stroke/complications , Hemorrhage/etiology , Heart Arrest/etiology , Catheter Ablation/methods , Treatment Outcome , Recurrence
5.
J Cardiovasc Electrophysiol ; 35(5): 950-964, 2024 May.
Article in English | MEDLINE | ID: mdl-38477184

ABSTRACT

INTRODUCTION: Peak frequency (PF) mapping is a novel method that may identify critical portions of myocardial substrate supporting reentry. The aim of this study was to describe and evaluate PF mapping combined with omnipolar voltage mapping in the identification of critical isthmuses of left atrial (LA) atypical flutters. METHODS AND RESULTS: LA omnipolar voltage and PF maps were generated in flutter using the Advisor HD-Grid catheter (Abbott) and EnSite Precision Mapping System (Abbott) in 12 patients. Normal voltage was defined as ≥0.5 mV, low-voltage as 0.1-0.5 mV, and scar as <0.1 mV. PF distributions were compared with ANOVA and post hoc Tukey analyses. The 1 cm radius from arrhythmia termination was compared to global myocardium with unpaired t-testing. The mean age was 65.8 ± 9.7 years and 50% of patients were female. Overall, 34 312 points were analyzed. Atypical flutters most frequently involved the mitral isthmus (58%) or anterior wall (25%). Mean PF varied significantly by myocardial voltage: normal (335.5 ± 115.0 Hz), low (274.6 ± 144.0 Hz), and scar (71.6 ± 140.5 Hz) (p < .0001 for all pairwise comparisons). All termination sites resided in low-voltage regions containing intermediate or high PF. Overall, mean voltage in the 1 cm radius from termination was significantly lower than the remaining myocardium (0.58 vs. 0.95 mV, p < .0001) and PF was significantly higher (326.4 vs. 245.1 Hz, p < .0001). CONCLUSION: Low-voltage, high-PF areas may be critical targets during catheter ablation of atypical atrial flutter.


Subject(s)
Action Potentials , Atrial Flutter , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Predictive Value of Tests , Humans , Atrial Flutter/physiopathology , Atrial Flutter/diagnosis , Atrial Flutter/surgery , Female , Male , Aged , Middle Aged , Heart Rate
6.
Article in English | MEDLINE | ID: mdl-39039649

ABSTRACT

INTRODUCTION: The impact of mRNA-based coronavirus disease-2019 (COVID-19) vaccines on atrial arrhythmias (AA) and ventricular arrhythmias incidence is unknown. METHODS: BIOTRONIK Home Monitoring data and Medicare Claims data were utilized to identify individuals implanted with a cardiac implantable electronic device (CIED) between 2010 and 2020 who received one or more doses of COVID-19 vaccine in 2021. The burden of AA (%) in the 3 months postvaccination was compared to those noted in the preceding 3 months using the Wilcoxon signed rank test. Sub-analyses comparing the effects of the influenza vaccine against the COVID-19 vaccine were also evaluated for individuals who received the influenza vaccine in 2020. A 1:1 propensity score match comparison between COVID-19 vaccine and non-vaccinated patients was also performed. RESULTS: First and second doses of the COVID-19 vaccine were administered to 7757 and 6579 individuals with a CIED (age 76.2 ± 9.0 years, 49% males), respectively. While a small but statistically significant increase in the burden of AA was noted in the 3 months postvaccination compared to the preceding 3 months after the first dose of the COVID-19 vaccine (0.43 ± 9.04%, p = .028) a similar rise in AA was found following the influenza vaccine and for matched patients who did not receive the COVID-19 vaccine. No significant difference in device therapies was seen pre- and postvaccination. CONCLUSIONS: Though we report a small but significant increase in the number of CIED-detected AAs following vaccination for COVID-19 over a 3-month window, we believe these results correlate more with time and the progressive nature of AF rather than the vaccine itself. While these data should not dissuade from the use of these vaccines, increased vigilance and prompt treatment of AF is required for high-risk groups, specifically males over 70 years of age, following vaccination.

7.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38587017

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Latin America , Treatment Outcome , Catheters , Asia , Catheter Ablation/adverse effects , Catheter Ablation/methods
8.
Circulation ; 146(7): 535-547, 2022 08 16.
Article in English | MEDLINE | ID: mdl-35726631

ABSTRACT

BACKGROUND: In the CABANA trial (Catheter Ablation vs Antiarrhythmic Drug Therapy for Atrial Fibrillation), catheter ablation did not significantly reduce the primary end point of death, disabling stroke, serious bleeding, or cardiac arrest compared with drug therapy by intention-to-treat, but did improve the quality of life and freedom from atrial fibrillation recurrence. In the heart failure subgroup, ablation improved both survival and quality of life. Cost-effectiveness was a prespecified CABANA secondary end point. METHODS: Medical resource use data were collected for all CABANA patients (N=2204). Costs for hospital-based care were assigned using prospectively collected bills from US patients (n=1171); physician and medication costs were assigned using the Medicare Fee Schedule and National Average Drug Acquisition Costs, respectively. Extrapolated life expectancies were estimated using age-based survival models. Quality-of-life adjustments were based on EQ-5D-based utilities measured during the trial. The primary outcome was the incremental cost-effectiveness ratio, comparing ablation with drug therapy on the basis of intention-to-treat, and assessed from the US health care sector perspective. RESULTS: Costs in the first 3 months averaged $20 794±SD 1069 higher with ablation compared with drug therapy. The cumulative within-trial 5-year cost difference was $19 245 (95% CI, $11 360-$27 170) and the lifetime mean cost difference was $15 516 (95% CI, -$2963 to $35,512) higher with ablation than with drug therapy. The drug therapy arm accrued an average of 12.5 life-years (LYs) and 10.7 quality-adjusted life-years (QALYs). For the ablation arm, the corresponding estimates were 12.6 LYs and 11.0 QALYs. The incremental cost-effectiveness ratio was $57 893 per QALY gained, with 75% of bootstrap replications yielding an incremental cost-effectiveness ratio <$100 000 per QALY gained. With no quality-of-life/utility adjustments, the incremental cost-effectiveness ratio was $183 318 per LY gained. CONCLUSIONS: Catheter ablation of atrial fibrillation was economically attractive compared with drug therapy in the CABANA Trial overall at present benchmarks for health care value in the United States on the basis of projected incremental QALYs but not LYs alone.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Aged , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/drug therapy , Atrial Fibrillation/surgery , Cost-Benefit Analysis , Humans , Medicare , Quality of Life , Quality-Adjusted Life Years , United States
9.
Circulation ; 145(12): 906-915, 2022 03 22.
Article in English | MEDLINE | ID: mdl-35135308

ABSTRACT

BACKGROUND: We aimed to assess the prevalence of ischemic brain lesions detected by magnetic resonance imaging and their association with cognitive function 3 months after first-time ablation using continuous oral anticoagulation in patients with paroxysmal atrial fibrillation (AF). METHODS: We performed a prespecified analysis of the AXAFA-AFNET 5 trial (Anticoagulation Using the Direct Factor Xa Inhibitor Apixaban During Atrial Fibrillation Catheter Ablation: Comparison to Vitamin K Antagonist Therapy), which randomized 674 patients with AF 1:1 to uninterrupted apixaban or vitamin K antagonist therapy before first-time ablation. Brain magnetic resonance imaging using fluid-attenuated inversion recovery and high-resolution diffusion-weighted imaging was obtained within 3 to 48 hours after AF ablation in all eligible patients enrolled in 25 study centers in Europe and the United States. Patients underwent cognitive assessment 3 to 6 weeks before ablation and 3 months after ablation using the Montreal Cognitive Assessment (MoCA). RESULTS: In 84 (26.1%) of 321 patients with analyzable magnetic resonance imaging, high-resolution diffusion-weighted imaging detected at least 1 acute brain lesion, including 44 (27.2%) patients treated with apixaban and 40 (24.8%) patients treated with vitamin K antagonist (P=0.675). Median MoCA score was similar in patients with or without acute brain lesions at 3 months after ablation (28 [interquartile range (IQR), 26-29] versus 28 [IQR, 26-29]; P=0.948). Cerebral chronic white matter damage (defined as Wahlund score ≥4 points) detected by fluid-attenuated inversion recovery was present in 130 (40.5%) patients and associated with lower median MoCA scores before ablation (27 [IQR, 24-28] versus 27 [IQR, 25-29]; P=0.026) and 3 months after ablation (27 [IQR, 25-29] versus 28 [IQR, 26-29]; P=0.011). This association was no longer significant when adjusted for age and sex. Age was associated with lower MoCA scores before ablation (relative risk, 1.02 per 10 years [95% CI, 1.01-1.03]) and 3 months after ablation (relative risk, 1.02 per 10 years [95% CI, 1.01-1.03]). CONCLUSIONS: Chronic white matter damage as well as acute ischemic lesions detected by brain magnetic resonance imaging were found frequently after first-time ablation for paroxysmal AF using uninterrupted oral anticoagulation. Acute ischemic brain lesions detected by high-resolution diffusion-weighted imaging were not associated with cognitive function at 3 months after ablation. Lower MoCA scores before and after ablation were associated only with older age, highlighting the safety of AF ablation on uninterrupted oral anticoagulation. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02227550.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Anticoagulants/therapeutic use , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/drug therapy , Atrial Fibrillation/surgery , Brain/diagnostic imaging , Catheter Ablation/adverse effects , Cognition , Humans , Magnetic Resonance Imaging , Treatment Outcome , Vitamin K
10.
Circulation ; 145(4): 242-255, 2022 01 25.
Article in English | MEDLINE | ID: mdl-34985309

ABSTRACT

BACKGROUND: Direct oral anticoagulants (DOACs) are preferred over warfarin for stroke prevention in atrial fibrillation. Meta-analyses using individual patient data offer substantial advantages over study-level data. METHODS: We used individual patient data from the COMBINE AF (A Collaboration Between Multiple Institutions to Better Investigate Non-Vitamin K Antagonist Oral Anticoagulant Use in Atrial Fibrillation) database, which includes all patients randomized in the 4 pivotal trials of DOACs versus warfarin in atrial fibrillation (RE-LY [Randomized Evaluation of Long-Term Anticoagulation Therapy], ROCKET AF [Rivaroxaban Once Daily Oral Direct Factor Xa Inhibition Compared With Vitamin K Antagonism for Prevention of Stroke and Embolism Trial in Atrial Fibrillation], ARISTOTLE [Apixaban for Reduction in Stroke and Other Thromboembolic Events in Atrial Fibrillation], and ENGAGE AF-TIMI 48 [Effective Anticoagulation With Factor Xa Next Generation in Atrial Fibrillation-Thrombolysis in Myocardial Infarction 48]), to perform network meta-analyses using a stratified Cox model with random effects comparing standard-dose DOAC, lower-dose DOAC, and warfarin. Hazard ratios (HRs [95% CIs]) were calculated for efficacy and safety outcomes. Covariate-by-treatment interaction was estimated for categorical covariates and for age as a continuous covariate, stratified by sex. RESULTS: A total of 71 683 patients were included (29 362 on standard-dose DOAC, 13 049 on lower-dose DOAC, and 29 272 on warfarin). Compared with warfarin, standard-dose DOACs were associated with a significantly lower hazard of stroke or systemic embolism (883/29 312 [3.01%] versus 1080/29 229 [3.69%]; HR, 0.81 [95% CI, 0.74-0.89]), death (2276/29 312 [7.76%] versus 2460/29 229 [8.42%]; HR, 0.92 [95% CI, 0.87-0.97]), and intracranial bleeding (184/29 270 [0.63%] versus 409/29 187 [1.40%]; HR, 0.45 [95% CI, 0.37-0.56]), but no statistically different hazard of major bleeding (1479/29 270 [5.05%] versus 1733/29 187 [5.94%]; HR, 0.86 [95% CI, 0.74-1.01]), whereas lower-dose DOACs were associated with no statistically different hazard of stroke or systemic embolism (531/13 049 [3.96%] versus 1080/29 229 [3.69%]; HR, 1.06 [95% CI, 0.95-1.19]) but a lower hazard of intracranial bleeding (55/12 985 [0.42%] versus 409/29 187 [1.40%]; HR, 0.28 [95% CI, 0.21-0.37]), death (1082/13 049 [8.29%] versus 2460/29 229 [8.42%]; HR, 0.90 [95% CI, 0.83-0.97]), and major bleeding (564/12 985 [4.34%] versus 1733/29 187 [5.94%]; HR, 0.63 [95% CI, 0.45-0.88]). Treatment effects for standard- and lower-dose DOACs versus warfarin were consistent across age and sex for stroke or systemic embolism and death, whereas standard-dose DOACs were favored in patients with no history of vitamin K antagonist use (P=0.01) and lower creatinine clearance (P=0.09). For major bleeding, standard-dose DOACs were favored in patients with lower body weight (P=0.02). In the continuous covariate analysis, younger patients derived greater benefits from standard-dose (interaction P=0.02) and lower-dose DOACs (interaction P=0.01) versus warfarin. CONCLUSIONS: Compared with warfarin, DOACs have more favorable efficacy and safety profiles among patients with atrial fibrillation.


Subject(s)
Anticoagulants/therapeutic use , Warfarin/therapeutic use , Administration, Oral , Age Factors , Aged , Anticoagulants/pharmacology , Female , Humans , Male , Network Meta-Analysis , Randomized Controlled Trials as Topic , Risk Factors , Sex Factors , Warfarin/pharmacology
11.
Stroke ; 54(4): 983-991, 2023 04.
Article in English | MEDLINE | ID: mdl-36729390

ABSTRACT

BACKGROUND: Carotid stenosis is thought to be the primary risk factor for central retinal artery occlusion (CRAO); however, it is not known whether atrial fibrillation (AF)-a cardiac arrhythmia that underlies over 25% of cerebral ischemic strokes-predisposes patients to CRAO. METHODS: A retrospective, observational, cohort study was performed using data from the State Inpatient Databases and State Emergency Department Databases from New York (2006-2015), California (2003-2011), and Florida (2005-2015) to determine the association between AF and CRAO. The primary exposure was hospital-documented AF. The primary end point was hospital-documented CRAO, defined as having an International Classification of Diseases, Ninth Revision, Clinical Modification, code 362.31 in the primary diagnosis position. Cause-specific hazard models were used to model CRAO-free survival among patients according to hospital-documented AF status. RESULTS: Of 39 834 885 patients included in the study, 2 723 842 (median age, 72.7 years; 48.5% women) had AF documented during the exposure window. The median follow-up duration was 6 years and 1 month. Patients with AF were older, more likely to be of non-Hispanic White race/ethnicity, and had a higher burden of cardiovascular comorbidities compared with patients without AF. The cumulative incidence of CRAO determined prospectively after exclusions was 8.69 per 100 000 at risk in those with AF and 2.39 per 100 000 at risk in those without AF over the study period. Before adjustment, AF was associated with higher risk of CRAO (hazard ratio, 2.55 [95% CI, 2.15-3.03]). However, after adjustment for demographics, state, and cardiovascular comorbidities, there was an inverse association between AF and risk of CRAO (adjusted hazard ratio, 0.72 [95% CI, 0.60-0.87]). These findings were robust in our prespecified sensitivity analyses. By contrast, positive control outcomes of embolic and ischemic stroke showed an expected strong relationship between AF and risk of stroke. CONCLUSIONS: We found an inverse association between AF and CRAO in a large, representative study of hospitalized patients; however, this cohort did not ascertain AF or CRAO occurring outside of hospital or emergency department settings.


Subject(s)
Atrial Fibrillation , Retinal Artery Occlusion , Stroke , Aged , Female , Humans , Male , Atrial Fibrillation/complications , Cohort Studies , Hospitals , Incidence , Retinal Artery Occlusion/diagnosis , Retrospective Studies , Risk Factors , Stroke/epidemiology
12.
Lancet ; 399(10333): 1383-1390, 2022 04 09.
Article in English | MEDLINE | ID: mdl-35385695

ABSTRACT

BACKGROUND: Direct-acting oral anticoagulant use for stroke prevention in atrial fibrillation is limited by bleeding concerns. Asundexian, a novel, oral small molecule activated coagulation factor XIa (FXIa) inhibitor, might reduce thrombosis with minimal effect on haemostasis. We aimed to determine the optimal dose of asundexian and to compare the incidence of bleeding with that of apixaban in patients with atrial fibrillation. METHODS: In this randomised, double-blind, phase 2 dose-finding study, we compared asundexian 20 mg or 50 mg once daily with apixaban 5 mg twice daily in patients aged 45 years or older with atrial fibrillation, a CHA2DS2-VASc score of at least 2 if male or at least 3 if female, and increased bleeding risk. The study was conducted at 93 sites in 14 countries, including 12 European countries, Canada, and Japan. Participants were randomly assigned (1:1:1) to a treatment group using an interactive web response system, with randomisation stratified by whether patients were receiving a direct-acting oral anticoagulant before the study start. Masking was achieved using a double-dummy design, with participants receiving both the assigned treatment and a placebo that resembled the non-assigned treatment. The primary endpoint was the composite of major or clinically relevant non-major bleeding according to International Society on Thrombosis and Haemostasis criteria, assessed in all patients who took at least one dose of study medication. This trial is registered with ClinicalTrials.gov, NCT04218266, and EudraCT, 2019-002365-35. FINDINGS: Between Jan 30, 2020, and June 21, 2021, 862 patients were enrolled. 755 patients were randomly assigned to treatment. Two patients (assigned to asundexian 20 mg) never took any study medication, resulting in 753 patients being included in the analysis (249 received asundexian 20 mg, 254 received asundexian 50 g, and 250 received apixaban). The mean age of participants was 73·7 years (SD 8·3), 309 (41%) were women, 216 (29%) had chronic kidney disease, and mean CHA2DS2-VASc score was 3·9 (1·3). Asundexian 20 mg resulted in 81% inhibition of FXIa activity at trough concentrations and 90% inhibition at peak concentrations; asundexian 50 mg resulted in 92% inhibition at trough concentrations and 94% inhibition at peak concentrations. Ratios of incidence proportions for the primary endpoint were 0·50 (90% CI 0·14-1·68) for asundexian 20 mg (three events), 0·16 (0·01-0·99) for asundexian 50 mg (one event), and 0·33 (0·09-0·97) for pooled asundexian (four events) versus apixaban (six events). The rate of any adverse event occurring was similar in the three treatment groups: 118 (47%) with asundexian 20 mg, 120 (47%) with asundexian 50 mg, and 122 (49%) with apixaban. INTERPRETATION: The FXIa inhibitor asundexian at doses of 20 mg and 50 mg once daily resulted in lower rates of bleeding compared with standard dosing of apixaban, with near-complete in-vivo FXIa inhibition, in patients with atrial fibrillation. FUNDING: Bayer.


Subject(s)
Anticoagulants , Atrial Fibrillation , Factor Xa Inhibitors , Aged , Anticoagulants/adverse effects , Atrial Fibrillation/drug therapy , Double-Blind Method , Factor Xa Inhibitors/adverse effects , Female , Hemorrhage/chemically induced , Humans , Male , Pyrazoles/adverse effects , Pyridones/adverse effects , Treatment Outcome
13.
J Cardiovasc Electrophysiol ; 34(4): 823-830, 2023 04.
Article in English | MEDLINE | ID: mdl-36738152

ABSTRACT

INTRODUCTION: Although atrial fibrillation (AF) ablation has become increasingly safer, rehospitalization and emergency department (ED) evaluations can occur in the postablation period. Better understanding of the frequency, causes, and predictors for hospitalization and ED evaluation after ablation are needed, particularly as same-day discharge programs expand. METHODS: The Optum Clinformatics database was used to define rates, causes, and predictors of hospital and ED care after AF ablation performed between January 2016 and May 2019. Primary outcomes were all-cause hospital and ED care within 30 days of discharge. Independent predictors of all-cause ED and hospital admissions care were determined via logistic regression. RESULTS: Of the 18 848 patients in this study, the mean age was 67.5 ± 10 years, 37.9% were female, and the mean CHA2 DS2 -VASc score was 3.27 ± 1.84. Within 30 days of AF ablation, 1440 of 18 848 patients (7.6%) required hospital care of which 15% had >1 admission; 7.9% required ED care of which 28.6% had >1 ED visit. The most common reasons for hospital admission (which occurred on average 12.3 days after discharge) were supraventricular tachycardia (SVT) or AF (33.2%), heart failure (12.7%), and infection (12.2%). The most common reasons for ED care were SVT/AF (15.0%), noncardiac chest pain (13.3%), and noninfectious respiratory illness (12.2%). Age, female sex, ablation in an inpatient setting, and co-morbidities were associated with increased risk of rehospitalization. Age, female sex, patient comorbidities, and non-use of direct oral anticoagulation were associated with increased risk of ED visit. CONCLUSION: Approximately 7%-8% of patients require unplanned hospitalization or ED care after AF ablation, most commonly due to SVT/AF. Predictors of unscheduled care include patient age, sex, and several patient comorbidities. This study can inform quality improvement initiatives by identifying common causes for unscheduled care.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Tachycardia, Paroxysmal , Tachycardia, Supraventricular , Humans , Female , Middle Aged , Aged , Male , Atrial Fibrillation/surgery , Tachycardia, Supraventricular/surgery , Emergency Service, Hospital , Catheter Ablation/adverse effects , Tachycardia, Paroxysmal/surgery , Hospitals
14.
J Cardiovasc Electrophysiol ; 34(4): 1015-1023, 2023 04.
Article in English | MEDLINE | ID: mdl-36807378

ABSTRACT

INTRODUCTION: The Micra Coverage with Evidence Development (CED) Study is a novel comparative analysis of Micra (leadless VVI) and transvenous single-chamber ventricular pacemakers (transvenous VVI) using administrative claims data. To compare chronic complications, device reinterventions, heart failure hospitalizations, and all-cause mortality after 3 years of follow-up. METHODS: US Medicare claims data linked to manufacturer device registration information were used to identify Medicare beneficiaries with a de novo implant of either a Micra VR leadless VVI or transvenous VVI pacemaker from March 9, 2017 to December 31, 2018. Unadjusted and propensity score overlap-weight adjusted Fine-Gray competing risk models were used to compare outcomes at 3 years. RESULTS: Leadless VVI patients (N = 6219) had a 32% lower rate of chronic complications and a 41% lower rate of reintervention compared with transvenous VVI patients (N = 10 212) (chronic complication hazard ratio [HR] 0.68; 95% confidence interval [CI], 0.59-0.78; reintervention HR 0.59; 95% CI 0.44-0.78). Infections rates were significantly lower among patients with a leadless VVI (<0.2% vs. 0.7%, p < .0001). Patients with a leadless VVI also had slightly lower rates of heart failure hospitalization (HR 0.90; 95% CI 0.84-0.97). There was no difference in the adjusted 3-year all-cause mortality rate (HR 0.97; 95% CI, 0.92-1.03). CONCLUSION: This nationwide comparative evaluation of leadless VVI versus transvenous VVI de novo pacemaker implants demonstrated that the leadless group had significantly fewer complications, reinterventions, heart failure hospitalizations, and infections than the transvenous group at 3 years, confirming that the previously reported shorter-term advantages associated with leadless pacing persist and continue to accrue in the medium-to-long-term.


Subject(s)
Heart Failure , Pacemaker, Artificial , Humans , Aged , United States , Follow-Up Studies , Equipment Design , Medicare , Pacemaker, Artificial/adverse effects , Heart Failure/etiology
15.
J Cardiovasc Electrophysiol ; 34(7): 1552-1560, 2023 07.
Article in English | MEDLINE | ID: mdl-37293826

ABSTRACT

INTRODUCTION: Accurate localization of septal outflow tract premature ventricular contractions (PVCs) is often difficult due to frequent mid-myocardial or protected origin. Compared with traditional activation mapping, CARTO Ripple mapping provides visualization of all captured electrogram data without assignment of a specific local activation time and thus may enhance PVC localization. METHODS: Electroanatomic maps for consecutive catheter ablation procedures for septal outflow tract PVCs (July 2018-December 2020) were analyzed. For each PVC, we identified the earliest local activation point (EA), defined by the point of maximal -dV/dt in a simultaneously recorded unipolar electrogram, and the earliest Ripple signal (ERS), defined as the earliest point at which three grouped simultaneous Ripple bars appeared in late diastole. Immediate success was defined as full suppression of the clinical PVC. RESULTS: Fifty-seven unique PVCs in 55 procedures were included. When ERS and EA were in the same chamber (RV, LV, or CS), the odds ratio for the successful procedure was 13.1 (95% confidence interval [CI] 2.2-79.9, p = .005). Discordance between sites was associated with a higher likelihood of needing multi-site ablation (odds ratio [OR] 7.9 [1.4-4.6; p = .020]). Median EA-ERS distance in successful versus unsuccessful cases was 4.6 mm (interquartile range 2.9-8.5) versus 12.5 mm (7.8-18.5); (p = .020). CONCLUSION: Greater EA-ERS concordance was associated with higher odds of single-site PVC suppression and successful septal outflow tract PVC ablation. Visualization of complex signals via automated Ripple mapping may offer rapid localization information complementary to local activation mapping for PVCs of mid-myocardial origin.


Subject(s)
Catheter Ablation , Ventricular Premature Complexes , Humans , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/surgery , Ventricular Premature Complexes/complications , Treatment Outcome , Catheter Ablation/adverse effects , Catheter Ablation/methods , Catheters
16.
J Cardiovasc Electrophysiol ; 34(1): 197-206, 2023 01.
Article in English | MEDLINE | ID: mdl-36317470

ABSTRACT

INTRODUCTION: Micra atrioventricular (AV) provides leadless atrioventricular synchronous pacing by sensing atrial contraction (A4 signal). Real-world operation and reliability of AV synchrony (AVS) assessment using device data have not been described. The purposes of this study were to (1) assess the correlation between AVS and atrial mechanical sensed-ventricular pacing (AM-VP) percentages in patients with permanent high-degree AV block and (2) report on the real-world effectiveness of Micra AV. METHODS: The correlation between ECG-determined AVS in-clinic and device-collected %AM-VP was assessed using data from 40 patients with high-degree AV block enrolled in the Micra Atrial tRacking using a Ventricular AccELerometer (MARVEL) 2 study. A retrospective analysis to assess continuously-sampled %AM-VP since last session, device programming, and electrical parameters was performed using Micra AV transmissions from the Medtronic CareLink database. Patients with transmissions ≥180 days postimplant were included. RESULTS: Among the 40 MARVEL 2 AV block patients with a median %VP of 99.7%, AVS was highly correlated with AM-VP (median AVS 87.1%, median AM-VP 79.1%; R2 = 0.764, p < .001). The CareLink cohort included 4384 patients programmed to VDD mode. The mean A4 amplitude was 2.3 ± 1.8 m/s2 at implant and 2.3 ± 1.6 m/s2 at 28 weeks. In patients with %VP >90% (n = 1662), the median %AM-VP was 74.7%. For the full cohort, median %VP was 65.6% and median projected battery longevity was 10.5 years. CONCLUSION: In patients with a high pacing burden, %AM-VP provides a reasonable estimation of AVS. The first large real-world analysis of Micra AV patients with >90% VP showed stable atrial sensing over time with a median %AM-VP, a correlate of AVS, of 74.7%.


Subject(s)
Atrial Fibrillation , Atrioventricular Block , Pacemaker, Artificial , Humans , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Retrospective Studies , Reproducibility of Results , Cardiac Pacing, Artificial
17.
J Cardiovasc Electrophysiol ; 34(11): 2233-2242, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37702140

ABSTRACT

BACKGROUND: Traditional transvenous pacemakers are associated with worsening tricuspid valve function due to lead-related leaflet impingement, as well as ventricular dysfunction related to electromechanical dyssynchrony from chronic right ventricular (RV) pacing. The association of leadless pacing with ventricular and valvular function has not been well established. We aimed to assess the association of leadless pacemaker placement with changes in valvular regurgitation and ventricular function. METHODS AND RESULTS: Echocardiographic features before and after leadless pacemaker implant were analyzed in consecutive patients who received a leadless pacemaker with pre- and postprocedure echocardiography at Duke University Hospital between November 2014 and November 2019. Valvular regurgitation was graded ordinally from 0 (none) to 3 (severe). Among 54 patients, the mean age was mean age was 70.1 ± 14.3 years, 24 (44%) were women, and the most frequent primary pacing indication was complete heart block in 24 (44%). The median RV pacing burden was 45.4 (interquartile range [IQR] 3.5-97.0). On echocardiogram performed 8.9 months (IQR 4.5-14.5) after implant, there was no change in the average severity of tricuspid regurgitation (mean change 0.07 ± 1.15, p = .64) from pre-procedure echocardiogram. We observed a decrease in the average left ventricular ejection fraction (LVEF) (52.3 ± 9.3 to 47.9 ± 12.1, p = .0019) and tricuspid annular plane systolic excursion (TAPSE) (1.8 ± 0.6 to 1.6 ± 0.4, p = .0437). Thirteen patients (24%) had absolute drop in LVEF of ≥10%. CONCLUSION: We did not observe short term worsening valvular function in patients with leadless pacemakers. However, consistent with the pathophysiologic impact of RV pacing, leadless pacing was associated with a reduction in biventricular function.


Subject(s)
Pacemaker, Artificial , Tricuspid Valve Insufficiency , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Ventricular Function, Left , Stroke Volume , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/therapy , Echocardiography , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods
18.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37490349

ABSTRACT

AIMS: After an ischaemic stroke, atrial fibrillation (AF) detection allows for improved secondary prevention strategies. This study aimed to compare AF detection and oral anticoagulant (OAC) initiation in patients with an insertable cardiac monitor (ICM) vs. external cardiac monitor (ECM) after ischaemic stroke. METHODS AND RESULTS: Medicare Fee-for-Service (FFS) insurance claims and Abbott Labs device registration data were used to identify patients hospitalized with an ischaemic stroke in 2017-2019 who received an ICM or ECM within 3 months. Patients with continuous Medicare FFS insurance and prescription drug enrolment in the prior year were included. Patients with prior AF, atrial flutter, cardiac devices, or OAC were excluded. Insertable cardiac monitor and ECM patients were propensity score matched 1:4 on demographics, comorbidities, and stroke hospitalization characteristics. The outcomes of interest were AF detection and OAC initiation evaluated with Kaplan-Meier and Cox proportional hazard regression analyses. A total of 5702 Medicare beneficiaries (ICM, n = 444; ECM, n = 5258) met inclusion criteria. The matched cohort consisted of 2210 Medicare beneficiaries (ICM, n = 442; ECM, n = 1768) with 53% female, mean age 75 years, and mean CHA2DS2-VASc score 4.6 (1.6). Insertable cardiac monitor use was associated with a higher probability of AF detection [(hazard ratio (HR) 2.88, 95% confidence interval (CI) (2.31, 3.59)] and OAC initiation [HR 2.91, CI (2.28, 3.72)] compared to patients monitored only with ECM. CONCLUSION: Patients with an ischaemic stroke monitored with an ICM were almost three times more likely to be diagnosed with AF and to be prescribed OAC compared to patients who received ECM only.


Subject(s)
Atrial Fibrillation , Brain Ischemia , Ischemic Stroke , Stroke , Humans , Female , Aged , United States/epidemiology , Male , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Stroke/diagnosis , Stroke/epidemiology , Stroke/etiology , Brain Ischemia/diagnosis , Brain Ischemia/epidemiology , Brain Ischemia/prevention & control , Medicare , Anticoagulants/adverse effects , Prescriptions
19.
Europace ; 25(6)2023 06 02.
Article in English | MEDLINE | ID: mdl-37354453

ABSTRACT

AIMS: Atrial fibrillation (AF) is the most common sustained arrhythmia encountered in clinical practice. Episodes may stop spontaneously (paroxysmal AF); may terminate only via intervention (persistent AF); or may persist indefinitely (permanent AF) (see European and American guidelines, referenced below, for more precise definitions). Recently, there has been renewed interest in an approach to terminate AF acutely referred to as 'pill-in-the-pocket' (PITP). The PITP is recognized in both the US and European guidelines as an effective option using an oral antiarrhythmic drug for acute conversion of acute/recent-onset AF. However, how PITP is currently used has not been systematically evaluated. METHODS AND RESULTS: The recently published Antiarrhythmic Interventions for Managing Atrial Fibrillation (AIM-AF) survey included questions regarding current PITP usage, stratified by US vs. European countries surveyed, by representative countries within Europe, and by cardiologists vs. electrophysiologists. This manuscript presents the data from this planned sub-study. Our survey revealed that clinicians in both the USA and Europe consider PITP in about a quarter of their patients, mostly for recent-onset AF with minimal or no structural heart disease (guideline appropriate). However, significant deviations exist. See the Graphical abstract for a summary of the data. CONCLUSION: Our findings highlight the frequent use of PITP and the need for further physician education about appropriate and optimal use of this strategy.


Subject(s)
Anti-Arrhythmia Agents , Atrial Fibrillation , Humans , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Atrial Fibrillation/epidemiology , Europe
20.
Europace ; 25(12)2023 12 06.
Article in English | MEDLINE | ID: mdl-37897713

ABSTRACT

AIMS: Left atrial catheter ablation is well established in patients with symptomatic atrial fibrillation (AF) but associated with risk of embolism to the brain. The present analysis aims to assess the impact of diffusion-weighted imaging (DWI) slice thickness on the rate of magnetic resonance imaging (MRI)-detected ischaemic brain lesions after ablation. METHODS AND RESULTS: AXAFA-AFNET 5 trial (NCT02227550) participants underwent MRI using high-resolution (hr) DWI (slice thickness: 2.5-3 mm) and standard DWI (slice thickness: 5-6 mm) within 3-48 h after ablation. In 321 patients with analysable brain MRI (mean age 64 years, 33% female, median CHA2DS2-VASc 2), hrDWI detected at least one acute brain lesion in 84 (26.2%) patients and standard DWI in 60 (18.7%; P < 0.01) patients. High-resolution diffusion-weighted imaging detected more lesions compared to standard DWI (165 vs. 104; P < 0.01). The degree of agreement for lesion confirmation using hrDWI vs. standard DWI was substantial (κ = 0769). Comparing the proportion of DWI-detected lesions, lesion distribution, and total lesion volume per patient, there was no difference in the cohort of participants undergoing MRI at 1.5 T (n = 52) vs. 3 T (n = 269). CONCLUSION: The pre-specified AXAFA-AFNET 5 sub-analysis revealed significantly increased rates of MRI-detected acute brain lesions using hrDWI instead of standard DWI in AF patients undergoing ablation. In comparison to DWI slice thickness, MRI field strength had a no significant impact in the trial. Comparing the varying rates of ablation-related MRI-detected brain lesions across previous studies has to consider these technical parameters. Future studies should use hrDWI, as feasibility was demonstrated in the multicentre AXAFA-AFNET 5 trial.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Female , Middle Aged , Male , Magnetic Resonance Imaging/methods , Diffusion Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects