Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
BMC Med ; 13: 169, 2015 Jul 27.
Article in English | MEDLINE | ID: mdl-26212559

ABSTRACT

BACKGROUND: The introduction of modern troponin assays has facilitated diagnosis of acute myocardial infarction due to improved sensitivity with corresponding loss of specificity. Atrial fibrillation (AF) is associated with elevated levels of troponin. The aim of the present study was to evaluate the diagnostic performance of troponin I in patients with suspected acute coronary syndrome and chronic AF. METHODS: Contemporary sensitive troponin I was assayed in a derivation cohort of 90 patients with suspected acute coronary syndrome and chronic AF to establish diagnostic cut-offs. These thresholds were validated in an independent cohort of 314 patients with suspected myocardial infarction and AF upon presentation. Additionally, changes in troponin I concentration within 3 hours were used. RESULTS: In the derivation cohort, optimized thresholds with respect to a rule-out strategy with high sensitivity and a rule-in strategy with high specificity were established. In the validation cohort, application of the rule-out cut-off led to a negative predictive value of 97 %. The rule-in cut-off was associated with a positive predictive value of 88 % compared with 71 % if using the 99th percentile cut-off. In patients with troponin I levels above the specificity-optimized threshold, additional use of the 3-hour change in absolute/relative concentration resulted in a further improved positive predictive value of 96 %/100 %. CONCLUSIONS: Troponin I concentration and the 3-hour change in its concentration provide valid diagnostic information in patients with suspected myocardial infarction and chronic AF. With regard to AF-associated elevation of troponin levels, application of diagnostic cut-offs other than the 99th percentile might be beneficial.


Subject(s)
Atrial Fibrillation/complications , Myocardial Infarction/blood , Myocardial Infarction/diagnosis , Troponin I/blood , Aged , Biomarkers/blood , Chest Pain/etiology , Female , Humans , Male , Middle Aged , Myocardial Infarction/etiology , Predictive Value of Tests , Reference Values
2.
PLoS One ; 11(5): e0154724, 2016.
Article in English | MEDLINE | ID: mdl-27148734

ABSTRACT

BACKGROUND: Common ECG criteria such as ST-segment changes are of limited value in patients with suspected acute myocardial infarction (AMI) and bundle branch block or wide QRS complex. A large proportion of these patients do not suffer from an AMI, whereas those with ST-elevation myocardial infarction (STEMI) equivalent AMI benefit from an aggressive treatment. Aim of the present study was to evaluate the diagnostic information of cardiac troponin I (cTnI) in hemodynamically stable patients with wide QRS complex and suspected AMI. METHODS: In 417 out of 1818 patients presenting consecutively between 01/2007 and 12/2008 in a prospective multicenter observational study with suspected AMI a prolonged QRS duration was observed. Of these, n = 117 showed significant obstructive coronary artery disease (CAD) used as diagnostic outcome variable. cTnI was determined at admission. RESULTS: Patients with significant CAD had higher cTnI levels compared to individuals without (median 250ng/L vs. 11ng/L; p<0.01). To identify patients needing a coronary intervention, cTnI yielded an area under the receiver operator characteristics curve of 0.849. Optimized cut-offs with respect to a sensitivity driven rule-out and specificity driven rule-in strategy were established (40ng/L/96ng/L). Application of the specificity optimized cut-off value led to a positive predictive value of 71% compared to 59% if using the 99th percentile cut-off. The sensitivity optimized cut-off value was associated with a negative predictive value of 93% compared to 89% provided by application of the 99th percentile threshold. CONCLUSION: cTnI determined in hemodynamically stable patients with suspected AMI and wide QRS complex using optimized diagnostic thresholds improves rule-in and rule-out with respect to presence of a significant obstructive CAD.


Subject(s)
Coronary Stenosis/diagnosis , Myocardial Infarction/complications , Troponin I/blood , Aged , Algorithms , Biomarkers/blood , Coronary Stenosis/complications , Electrocardiography , Female , Humans , Male , Middle Aged , Myocardial Infarction/physiopathology , Patient Admission , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL