1.
J Am Pharm Assoc (2003) ; 54(1): 45-8, 2014.
Article in English | MEDLINE | ID: mdl-24257695

ABSTRACT

OBJECTIVE To confirm the anticipated image quality and absence of adverse reactions in patients undergoing clinical practice cerebrospinal fluid (CSF) leak imaging procedures using technetium Tc-99m pyrophosphate (PYP). METHODS Following the recent discontinuation of preservative-free calcium trisodium diethylene triamine pentaacetic acid kits, PYP was selected as a suitable alternative for CSF leak imaging procedures. Procedures were established for its preparation and dispensing, paying special attention to safety considerations, and its use in clinical practice was implemented. Medical records, including images, were reviewed for the first 15 patients undergoing clinical practice CSF imaging procedures using Tc-99m PYP to confirm anticipated image quality and absence of adverse effects. RESULTS Review of CSF leak imaging procedures using Tc-99m PYP in 15 patients showed images to be of uniformly high quality. The vast majority of injected radiopharmaceutical remained in the CSF throughout the duration of the imaging procedure, allowing visualization of CSF leaks. Only a small amount of Tc-99m PYP diffused into the blood with resultant uptake on the skeleton and excretion into the urine, which did not interfere with image interpretation. No adverse reactions were noted in any of the patients. CONCLUSION With proper attention to safety considerations, Tc-99m PYP is a safe and effective alternative for performing CSF leak imaging procedures.


Subject(s)
Cerebrospinal Fluid Rhinorrhea/diagnostic imaging , Cerebrospinal Fluid Rhinorrhea/diagnosis , Diagnostic Imaging/methods , Radiopharmaceuticals/administration & dosage , Technetium Tc 99m Pyrophosphate/administration & dosage , Adult , Aged , Aged, 80 and over , Cerebrospinal Fluid Leak , Female , Humans , Male , Middle Aged , Radionuclide Imaging , Young Adult
2.
J Am Pharm Assoc (2003) ; 53(1): 58-60, 2013.
Article in English | MEDLINE | ID: mdl-23636157

ABSTRACT

OBJECTIVE: To evaluate the self-sealing capacity of vial stoppers in two common radiopharmaceuticals after more than 10 needle punctures. METHODS: Assessment of self-sealing capacity was performed according to the self-sealing capacity test described in United States Pharmacopeial Convention (USP) General Chapter <381>. Groups of 10 vials of technetium (Tc)-99m sulfur colloid and Tc-99m tetrofosmin were tested for maintenance of self-sealing capacity following 10 punctures with 22-, 20-, and 18-gauge needles. Each vial was sequentially retested after additional sets of 10 punctures until failure of self-sealing capacity or until a total of 100 punctures, whichever came first. RESULTS: The median number of needle punctures with maintenance of self-sealing ability before failure for 22-, 20-, and 18-gauge needles was >100 (range all >100), >100 (all >100), and 60 (30-90), respectively, for sulfur colloid and >100 (all >100), >100 (50 to >100), and 50 (20-70), respectively, for tetrofosmin. Incidentally, coring particles were observed frequently in vials after many punctures with 18-gauge needles, but infrequently with 20-gauge and rarely with 22-gauge needles. CONCLUSION: Vial stoppers in two radiopharmaceutical products demonstrated robust self-sealing capacity, substantially exceeding the USP standard of 10 punctures with a 21-gauge needle. Coring particles were frequently observed after many punctures when using larger-bore needles but rarely when using smaller-bore needles. Under conditions commonly used, failure of self-sealing capacity and generation of coring particles are not anticipated to be problems encountered when puncturing vial stoppers of these two products substantially more than 10 times.


Subject(s)
Drug Packaging/standards , Needles , Rubber/chemistry , Organophosphorus Compounds/analysis , Organotechnetium Compounds/analysis , Pharmacopoeias as Topic , Radiopharmaceuticals/analysis , Technetium Tc 99m Sulfur Colloid/analysis , United States
3.
J Am Pharm Assoc (2003) ; 51(3): 359-62, 2011.
Article in English | MEDLINE | ID: mdl-21555286

ABSTRACT

OBJECTIVE: To evaluate alternative methods for radiochemical purity testing of indium (In)-111 capromab pendetide after the discontinuation of instant thin-layer chromatography silica gel (ITLC-SG) strips. DESIGN: Descriptive experimental study. SETTING: United States in 2009. PARTICIPANTS: Not applicable. INTERVENTION: Paper chromatography using Whatman 3MM strips, paper chromatography using Whatman 31ET strips, and mini-column chromatography using silica Sep-Pak cartridges were evaluated in the radiochemical purity testing of 13 consecutive vials of In-111 capromab pendetide prepared for clinical patient imaging procedures. These methods also were evaluated by testing seven aliquots of In-111 capromab pendetide that had been spiked with 5% to 15% In-111 pentetate (diethylene triamine pentaacetic acid). MAIN OUTCOME MEASURES: Correlation coefficients, radiochemical purity values for each method compared with ITLC-SG, and procedure times. RESULTS: Correlation coefficients of 0.988, 0.996, and 0.979 were found for ITLC-SG compared with Whatman 3MM, Whatman 31ET, and silica Sep-Pak, respectively. Compared with ITLC-SG, mean (±SD) radiochemical purity values differed by -0.8 ± 0.8 (range -2.5 to 0.4) for Whatman 3MM, -0.8 ± 0.6 (-2.3 to 0) for Whatman 31ET, and -0.5 ± 1.2 (-3.6 to 0.7) for silica Sep-Pak. The approximate time required to develop the chromatography strip or elute the mini-column was 3, 14, 5, and 6 minutes for ITLC-SG, Whatman 3MM, Whatman 31ET, and silica Sep-Pak, respectively. CONCLUSION: All three methods evaluated were acceptable alternatives to ITLC-SG for radiochemical purity testing of In-111 capromab pendetide. Based on its slightly higher correlation to ITLC-SG, slightly tighter SD and range, and slightly shorter development time, Whatman 31ET is preferred in our facility.


Subject(s)
Antibodies, Monoclonal/chemistry , Chromatography/methods , Indium Radioisotopes/chemistry , Chromatography, Paper/methods , Chromatography, Thin Layer/methods , Humans , Indicators and Reagents/chemistry , Time Factors
4.
J Am Pharm Assoc (2003) ; 50(3): 419-23, 2010.
Article in English | MEDLINE | ID: mdl-20452919

ABSTRACT

OBJECTIVES: To elucidate radiopharmaceutical considerations for using technetium Tc-99m albumin aggregated (Tc-99m MAA) in lung transplant patients and to establish an appropriate routine dose and preparation procedure. SETTING: Tertiary care academic hospital during May 2007 to May 2009. PRACTICE DESCRIPTION: Nuclear pharmacist working in nuclear medicine department. PRACTICE INNOVATION: Radiopharmaceutical considerations deemed important for the use of Tc-99m MAA in lung transplant patients included radioactivity dose, particulate dose, rate of the radiolabeling reaction (preparation time), and final radiochemical purity. Evaluation of our initial 12-month experience, published literature, and professional practice guidelines provided the basis for establishing an appropriate dose and preparation procedure of Tc-99m MAA for use in lung transplant patients. MAIN OUTCOME MEASURES: Radiochemical purity at typical incubation times and image quality in subsequent lung transplant patients imaged during the next 12 months. RESULTS: Based on considerations of radioactivity dose, particulate dose, rate of the radiolabeling reaction (preparation time), and final radiochemical purity, a routine dose consisting of 3 mCi (111 MBq) and 100,000 particles of Tc-99m MAA for planar perfusion lung imaging of adult lung transplant patients was established as reasonable and appropriate. MAA kits were prepared with a more reasonable amount of Tc-99m and yielded high radiochemical purity values in typical incubation times. Images have continued to be of high diagnostic quality. CONCLUSION: Tc-99m MAA used for lung transplant imaging can be readily prepared with high radiochemical purity to provide a dose of 3 mCi (111 GBq)/100,000 particles, which provides images of high diagnostic quality.


Subject(s)
Lung Transplantation/diagnostic imaging , Radiopharmaceuticals , Technetium Tc 99m Aggregated Albumin , Academic Medical Centers , Drug Compounding , Humans , Radiation Dosage , Radionuclide Imaging
5.
J Am Pharm Assoc (2003) ; 48(3): 413-6, 2008.
Article in English | MEDLINE | ID: mdl-18595828

ABSTRACT

OBJECTIVE: To review special safety considerations in the preparation of technetium 99m (Tc-99m) diethylenetriaminepentaacetic acid (DTPA; generic name, pentetate) for cerebrospinal fluid (CSF)-related imaging procedures. DATA SOURCES: Review of practices and results at one institution supplemented with findings and recommendations from the literature. Literature searches were conducted via Medline/PubMed using the following terms: Tc-99m DTPA/pentetate, CSF, cisternography, intrathecal, and adverse reactions. The author's own files were also searched for articles (e.g., in newsletters) not indexed by Medline/PubMed. STUDY SELECTION: Articles considered appropriate for review included all human research studies, reviews, case reports, abstracts, and letters published in English on Tc-99m DTPA use in CSF-related imaging procedures, especially with regard to safety or adverse reactions. DATA EXTRACTION: All information related to safety precautions and adverse reactions associated with Tc-99m DTPA injected intrathecally or otherwise used for CSF-related imaging procedures were considered. DATA SYNTHESIS: 18 years' experience in one institution was reviewed with the added perspective of literature findings and recommendations. CONCLUSION: With proper attention to safety considerations, Tc-99m DTPA can be safely used in CSF-related imaging procedures.


Subject(s)
Cerebrospinal Fluid/diagnostic imaging , Radiopharmaceuticals/adverse effects , Technetium Tc 99m Pentetate/adverse effects , Drug Compounding/methods , Drug Contamination/prevention & control , Endotoxins , Humans , Injections, Spinal , Radiography , Radiopharmaceuticals/standards , Technetium Tc 99m Pentetate/standards
6.
Appl Radiat Isot ; 66(2): 252-60, 2008 Feb.
Article in English | MEDLINE | ID: mdl-17933545

ABSTRACT

A blind performance test was conducted to evaluate dose-calibrator measurements at nuclear pharmacies in the United States (US). Two test-sample geometries were chosen to represent those used for measurements of 90Y-ibritumomab tiuxetan (ZEVALIN). The radioactivity concentration of test-samples was verified by the US National Institute of Standards and Technology. Forty-five results were reported by 10 participants. Eighty percent of reported values were within the US Pharmacopoeia content standard (+/-10%) for 90Y-ZEVALIN. All results were within US Nuclear Regulatory Commission conformance limits (+/-20%) for defining therapeutic misadministrations.


Subject(s)
Antibodies, Monoclonal/analysis , Radiopharmaceuticals/analysis , Yttrium Radioisotopes/analysis , Ambulatory Care Facilities/standards , Antibodies, Monoclonal/therapeutic use , Humans , Neoplasms/radiotherapy , Nuclear Medicine/standards , Pharmacies/standards , Pilot Projects , Quality Control , Radioimmunotherapy , Radiometry/methods , Radiometry/standards , Radiopharmaceuticals/standards , Radiopharmaceuticals/therapeutic use , Radiotherapy Dosage , Reference Standards , United States , Yttrium Radioisotopes/standards , Yttrium Radioisotopes/therapeutic use
7.
J Nucl Med Technol ; 45(2): 111-113, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28408704

ABSTRACT

Since the early 2000s, the method of evaluating pulmonary embolism has shifted from 99mTc-macroaggregated albumin (MAA) perfusion lung scans to CT angiography. 99mTc-MAA continues to be applied for patients with contraindications to CT angiography and for other uses. A reduced number of 99mTc-MAA particles is administered to patients with pulmonary hypertension or other risk factors. This study assessed the changing patterns of 99mTc-MAA use between 2000 and 2015 at a single institution by comparing snapshots of the procedures performed in those two years. Methods: Records for all patients receiving 99mTc-MAA in 2000 and 2015 were reviewed, making note of the type of imaging procedure, whether there was any contraindication to CT angiography, and whether a reduced number of 99mTc-MAA particles was administered. Results: In 2000, 99mTc-MAA was used for 489 lung scans for pulmonary embolism, 2 for peritoneovenous shunts, and 1 for a cardiac shunt. Of the lung scan patients, 46 (9%) had pulmonary hypertension. A reduced number of particles was administered to the pulmonary hypertension and cardiac shunt patients (47/492, or 9%). In 2015, 99mTc-MAA was used for 263 lung scans for pulmonary embolism, 33 for presurgical planning, 33 for patients with a lung transplant, 16 for pulmonary artery stenosis, 5 to determine hepatic artery microsphere eligibility, and 1 for a peritoneovenous shunt. Of the lung scans for pulmonary embolism, 256 of the 263 patients (97%) had a contraindication to CT angiography or a nondiagnostic CT angiogram, including 99 (38%) with pulmonary hypertension. A reduced number of particles was administered to the pulmonary hypertension patients, presurgical patients, and lung-transplant patients (165/351, or 47%). Conclusion: Comparing 2015 with 2000, lung scans for pulmonary embolism decreased 46%, from 489 to 263, apparently because of a shift to CT angiography, whereas other uses rose from 3 to 88. Administration of a reduced number of particles rose significantly from 9% to 47% of 99mTc-MAA doses. Although the total number of 99mTc-MAA doses dropped 29%, from 492 to 351, 99mTc-MAA remains an important radiopharmaceutical for both pulmonary embolism and other uses.


Subject(s)
Angiography/statistics & numerical data , Technetium Tc 99m Aggregated Albumin , Tomography, X-Ray Computed/statistics & numerical data , Humans , Lung/blood supply , Lung/diagnostic imaging , Pulmonary Embolism/diagnostic imaging
8.
J Nucl Med ; 46(1): 67-74, 2005 Jan.
Article in English | MEDLINE | ID: mdl-15632036

ABSTRACT

UNLABELLED: This study investigated the use of a corn oil emulsion as an inexpensive alternative to sincalide in the scintigraphic diagnosis of chronic acalculous cholecystitis (CAC). METHODS: Thirty patients with abdominal or right upper quadrant pain underwent (99m)Tc-disofenin hepatobiliary imaging for 60 min. After gallbladder filling, 30 mL of corn oil emulsion were administered orally to all patients followed by dynamic imaging for an additional 60 min in all patients and for 90 min in 26 patients. Gallbladder emptying kinetics were determined with gallbladder ejection fractions calculated at 30, 60, and 90 min. The results were compared with histopathologic or clinical follow-up data. RESULTS: Corn oil emulsion was found to be palatable and free of side effects in all patients. Seven of the 30 patients had histopathologic evidence of CAC, whereas the remaining 23 did not have evidence of gallbladder disease based on clinical follow-up. The 30-, 60-, and 90-min gallbladder ejection fractions were determined to be 25% +/- 22% (mean +/- SD), 47% +/- 28%, and 62% +/- 29%, respectively. Receiver-operating-characteristic analysis showed that the 60-min gallbladder ejection fraction best distinguished between CAC and non-gallbladder disease with an area under the curve of 0.963. A 60-min gallbladder ejection fraction of < or = 20% had 100% sensitivity, 96% specificity, 88% positive predictive value, 100% negative predictive value, and 97% overall accuracy for the diagnosis of CAC. CONCLUSION: Standardized corn oil emulsion appears to be an adequate and well-tolerated gallbladder stimulant. Based on receiver-operating-characteristic analysis, a 60-min gallbladder ejection fraction of < or = 20% using this simple cholecystagogue results in high diagnostic accuracy for CAC.


Subject(s)
Acalculous Cholecystitis/diagnostic imaging , Cholagogues and Choleretics , Corn Oil , Technetium Tc 99m Disofenin , Adolescent , Adult , Child , Chronic Disease , Emulsions , Female , Humans , Male , Middle Aged , Radioisotope Dilution Technique , Radionuclide Imaging , Radiopharmaceuticals , Reproducibility of Results , Sensitivity and Specificity
9.
J Nucl Med Technol ; 33(4): 232-3, 2005 Dec.
Article in English | MEDLINE | ID: mdl-16322124

ABSTRACT

OBJECTIVE: The recommended method for radiochemical purity testing of 99mTc-mertiatide involves the use of a C-18 solid-phase mini-column cartridge. The mertiatide package insert states that the solvents should be "pushed through the cartridge slowly," but a flow rate is not specified. The mini-column cartridge instruction sheet recommends flow rates of 5-10 and 2-10 mL/min for conditioning and for elution, respectively, of the cartridge. The purpose of this study was to evaluate the effect of different flow rates on determining the radiochemical purity of 99mTc-mertiatide. METHODS: Radiochemical purity was tested on 10 consecutive vials of 99mTc-mertiatide prepared for routine clinical use and on 4 vials of 99mTc-mertiatide spiked with 6%-15% free pertechnetate using 3 different flow rates: slow drip (5 mL/min for conditioning and 2 mL/min for elution), fast drip (10 mL/min for conditioning and 10 mL/min for elution), and very fast drip (about 15-20 mL/min for conditioning and about 15-20 mL/min for elution). An infusion pump was used to provide constant flow rates for the first 2 conditions, whereas manual handling, reflecting real-life practice, was used for the third condition. RESULTS: All 3 flow rates yielded essentially identical radiochemical purities for each vial tested (agreement was always within 0.3% for a given vial). The elapsed times for mini-column conditioning, loading, and elution were approximately 15, 5, and 3 min for the slow drip, fast drip, and very fast drip, respectively. CONCLUSION: Faster flow rates for mini-column testing of 99mTc-mertiatide save time (and correspondingly reduce radiation exposure to the worker) without adversely affecting the results of radiochemical purity determinations.


Subject(s)
Chromatography, Liquid/methods , Drug Evaluation, Preclinical/methods , Quality Assurance, Health Care/methods , Technetium Tc 99m Mertiatide/analysis , Chromatography, Liquid/instrumentation , Chromatography, Liquid/standards , Drug Evaluation, Preclinical/instrumentation , Drug Evaluation, Preclinical/standards , Flow Injection Analysis/methods , Quality Assurance, Health Care/standards , Radiopharmaceuticals/analysis , Radiopharmaceuticals/standards , Reproducibility of Results , Sensitivity and Specificity , Solvents/chemistry , Technetium Tc 99m Mertiatide/standards
10.
J Nucl Med Technol ; 43(2): 117-21, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25857418

ABSTRACT

UNLABELLED: During times of sincalide shortage, a fatty meal can be used to stimulate gallbladder contraction during hepatobiliary scintigraphy. However, if a patient has an abnormal gallbladder ejection fraction (GBEF), is the cause chronic cholecystitis or is it inadequate cholecystokinin stimulation due to poor gastric emptying? Hence, during the 2014 sincalide shortage, simultaneous liquid gastric emptying using (99m)Tc-sulfur colloid along with corn oil emulsion was initiated as routine practice in patients evaluated for GBEF. The objective of this study was to retrospectively assess the time course of gastric emptying in these patients, especially with regard to whether delayed gastric emptying may be a factor in some patients with a poor GBEF. METHODS: My institution's clinical imaging procedure during the 2014 sincalide shortage consisted of routine (99m)Tc-mebrofenin hepatobiliary scintigraphy followed by corn oil emulsion and (99m)Tc-sulfur colloid orally. Dynamic imaging with regions of interest encompassing the gallbladder and the stomach allowed determination of GBEF and gastric emptying. For this study, the imaging records for 53 consecutive patients undergoing this clinical procedure were reviewed. The time for half gastric emptying, along with percentage gastric emptying at the end of imaging, was evaluated in relationship to GBEF. RESULTS: Seventeen patients had a normal GBEF (74% ± 14%) and satisfactory gastric emptying (31 ± 21 min for half emptying, 75% ± 14% emptying at end of imaging); 17 patients had a normal GBEF (77% ± 17%) despite unsatisfactory gastric emptying (only 30% ± 14% emptying at end of imaging); 5 patients had an abnormal GBEF (19% ± 9%) and satisfactory gastric emptying (26 ± 19 min for half emptying, 82% ± 14% emptying at end of imaging), supporting a diagnosis of chronic cholecystitis; 11 patients had an abnormal GBEF (26% ± 9%) but also unsatisfactory gastric emptying (only 26% ± 13% emptying at end of imaging), which did offer additional support for a diagnosis of chronic cholecystitis; and 3 patients had a borderline GBEF (40% ± 2%) with satisfactory gastric emptying (59% ± 6% emptying at end of imaging). CONCLUSION: Simultaneous liquid gastric emptying can provide additional information in the interpretation of GBEF when a fatty meal is used as an oral cholecystagogue, especially to help differentiate chronic cholecystitis from inadequate cholecystokinin stimulation due to poor gastric emptying.


Subject(s)
Biliary Tract/diagnostic imaging , Corn Oil/pharmacology , Gallbladder Emptying/drug effects , Gallbladder/drug effects , Gallbladder/physiology , Gastric Emptying , Liver/diagnostic imaging , Administration, Oral , Bile/metabolism , Corn Oil/administration & dosage , Gallbladder/metabolism , Gastric Emptying/drug effects , Humans , Muscle Contraction/drug effects , Radionuclide Imaging , Retrospective Studies , Time Factors
11.
Health Phys ; 108(5): 520-37, 2015 May.
Article in English | MEDLINE | ID: mdl-25811150

ABSTRACT

To reconstruct reliable nuclear medicine-related occupational radiation doses or doses received as patients from radiopharmaceuticals over the last five decades, the authors assessed which radiopharmaceuticals were used in different time periods, their relative frequency of use, and typical values of the administered activity. This paper presents data on the changing patterns of clinical use of radiopharmaceuticals and documents the range of activity administered to adult patients undergoing diagnostic nuclear medicine procedures in the U.S. between 1960 and 2010. Data are presented for 15 diagnostic imaging procedures that include thyroid scan and thyroid uptake; brain scan; brain blood flow; lung perfusion and ventilation; bone, liver, hepatobiliary, bone marrow, pancreas, and kidney scans; cardiac imaging procedures; tumor localization studies; localization of gastrointestinal bleeding; and non-imaging studies of blood volume and iron metabolism. Data on the relative use of radiopharmaceuticals were collected using key informant interviews and comprehensive literature reviews of typical administered activities of these diagnostic nuclear medicine studies. Responses of key informants on relative use of radiopharmaceuticals are in agreement with published literature. Results of this study will be used for retrospective reconstruction of occupational and personal medical radiation doses from diagnostic radiopharmaceuticals to members of the U.S. radiologic technologists' cohort and in reconstructing radiation doses from occupational or patient radiation exposures to other U.S. workers or patient populations.


Subject(s)
Nuclear Medicine , Radiopharmaceuticals , Bone and Bones/diagnostic imaging , Brain/diagnostic imaging , Cerebrovascular Circulation , Humans , Liver/diagnostic imaging , Neoplasms/diagnostic imaging , Pulmonary Circulation , Radionuclide Imaging , Thyroid Gland/diagnostic imaging , Time Factors , United States
12.
Cancer Biother Radiopharm ; 18(4): 581-8, 2003 Aug.
Article in English | MEDLINE | ID: mdl-14503953

ABSTRACT

The purpose of this study was to determine whether there is evidence for hepatocellular radiation injury following treatment with (90)Y-SMT487 ((90)Y-DOTA-tyr3-octreotide, OctreoTher(TM)) in patients with extensive liver metastases from neuroendocrine tumors. Patients reported in this study participated in a Phase II trial of efficacy and safety of (90)Y-SMT487. The trial design called for three treatment cycles of 120 mCi each (4400 MBq) of (90)Y-SMT487. (111)In-pentetreotide SPECT images were used to determine the extent of liver metastases. Serum AST, ALT, and alkaline phosphatase levels were obtained at baseline and following each cycle of therapy. Least squares fit was applied to the serial liver enzyme measurements in patients with extensive liver metastases. Post-therapy liver enzyme measurements were also evaluated using WHO common toxicity criteria. Repeated-measures ANOVA and paired t-test were applied to the serial enzyme measures. There were 21 subjects. Fifteen of these had hepatic metastases with 12 demonstrating extensive (defined as 25% or more) liver involvement. In only 4 of these 15 did any of the three enzyme levels increase in WHO toxicity grade from baseline to final follow-up. We conclude that patients with diffuse SSTR positive hepatic metastases can be treated with a cumulative administered activity of 360 mCi (90)Y-SMT487 with only a small chance of developing mild acute or subacute hepatic radiation injury.


Subject(s)
Liver Neoplasms/radiotherapy , Liver/radiation effects , Octreotide/analogs & derivatives , Octreotide/therapeutic use , Receptors, Somatostatin/metabolism , Somatostatin/analogs & derivatives , Yttrium Radioisotopes/therapeutic use , Alanine Transaminase/blood , Alkaline Phosphatase/blood , Analysis of Variance , Aspartate Aminotransferases/blood , Carcinoma, Neuroendocrine/pathology , Clinical Protocols , Disease Progression , Humans , Liver/diagnostic imaging , Liver/pathology , Liver Neoplasms/metabolism , Liver Neoplasms/secondary , Octreotide/adverse effects , Octreotide/metabolism , Radiopharmaceuticals/adverse effects , Radiopharmaceuticals/metabolism , Radiopharmaceuticals/therapeutic use , Tomography, Emission-Computed, Single-Photon , Yttrium Radioisotopes/adverse effects , Yttrium Radioisotopes/metabolism
13.
Cancer Biother Radiopharm ; 19(1): 35-41, 2004 Feb.
Article in English | MEDLINE | ID: mdl-15068609

ABSTRACT

Y-90-DOTA-Phe1-Tyr3-Octreotide (90Y-SMT 487, OctreoTher) has shown potential for effectively treating patients with neuroendocrine tumors. The dose-limiting organ for this agent is the kidney. The purpose of this work is to assess the effectiveness of a commercially available amino acid solution on reducing renal uptake of 90Y-SMT 487 and determine the safety profile of this solution. Subjects with In-111 pentetreotide positive tumors and normal creatinine levels were treated with 3 cycles of 90Y-SMT 487, 120 mCi/cycle, at 6-9 week intervals. During each treatment two liters of an amino acid solution containing arginine and lysine (Aminosyn II 7%, Abbott Laboratories, Abbott Park, IL) were infused IV over 4 hours. Adverse events were recorded. To assess the effect of Aminosyn II on renal uptake of 90Y-SMT 487, a subgroup of subjects underwent bremsstrahlung imaging 24 hours following infusion. Kidney to liver (K/L) count density ratios were generated from the baseline In-111 pentetreotide images (performed without amino acid infusion) and the 90Y bremsstrahlung images. Follow-up creatinine levels were obtained. Thirty-seven subjects received a total of 89 90Y-SMT 487 treatments. The number of amino-acid infusions associated with one or more episodes of emesis was 53 (62%). During 13 (15%) of these infusions, the Aminosyn II rate had to be reduced because of severe nausea and vomiting. Symptomatic flushing occurred during 16 (18%) of the infusions. One subject experienced a near syncopal event shortly after completing the infusion. Creatinine levels remained normal in 34 of 36 subjects during a mean follow-up period of 9.8 months. Fourteen subjects underwent bremsstrahlung imaging following infusion of 90Y-SMT 487. Kidney uptake appeared to decrease with administration of the amino acid solution in 13 of 14 subjects. For the 28 individual kidneys, the mean percent decrease in the Kidney/Liver uptake ratio with the amino acid solution was found to be 32%. We conclude that 2 L of Aminosyn II 7% infused over 4 hours appears to notably reduce renal uptake of 90Y-SMT 487. Aminosyn is generally well tolerated, particularly at lower infusion rates with occasional moderate to severe nausea and vomiting at higher rates.


Subject(s)
Amino Acids/administration & dosage , Amino Acids/pharmacology , Kidney/drug effects , Octreotide/analogs & derivatives , Octreotide/administration & dosage , Octreotide/therapeutic use , Yttrium Radioisotopes/administration & dosage , Yttrium Radioisotopes/therapeutic use , Adult , Aged , Arginine/administration & dosage , Arginine/pharmacology , Carcinoid Tumor/metabolism , Carcinoid Tumor/radiotherapy , Female , Humans , Infusions, Intravenous , Kidney/metabolism , Lung Neoplasms/metabolism , Lung Neoplasms/radiotherapy , Lysine/administration & dosage , Lysine/pharmacology , Male , Meningioma/metabolism , Meningioma/radiotherapy , Middle Aged , Octreotide/adverse effects , Octreotide/pharmacokinetics , Pancreatic Neoplasms/metabolism , Pancreatic Neoplasms/radiotherapy , Radiopharmaceuticals/administration & dosage , Radiopharmaceuticals/adverse effects , Radiopharmaceuticals/pharmacokinetics , Radiopharmaceuticals/therapeutic use , Yttrium Radioisotopes/adverse effects , Yttrium Radioisotopes/pharmacokinetics
14.
J Nucl Med Technol ; 42(4): 289-91, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25168252

ABSTRACT

UNLABELLED: In response to U.S. Pharmacopeia general chapter <797> standards, a clean room was constructed for our in-house radiopharmacy. Previously, most patient doses were prepared as needed just before injection. Currently, to minimize repeated entries into the clean room, most patient doses are prepared in batches; that is, early morning and noontime preparation of doses to be injected at various times throughout the morning and the afternoon, respectively. Because these patient doses may be prepared well before injection time, radioactive decay necessitates higher amounts of radioactivity to be handled for patient dose preparation. Hence, absorbed radiation doses to staff, all of whom rotate into the radiopharmacy clean room in addition to their regular patient-related activities, were retrospectively evaluated. METHODS: Monthly dosimetry reports for body (chest badge) and extremities (finger ring) were retrospectively reviewed for each staff member for 12 mo before and 12 mo after implementation of the radiopharmacy clean room. Monthly data were evaluated for average and SD, and 12-mo groups were evaluated using a paired t test. Data for the second 12-mo period were also normalized to the same number of patient doses to account for an increase in procedure volume and were reevaluated. RESULTS: Before the radiopharmacy clean room had been implemented, average monthly absorbed radiation doses to body and extremities were 23 ± 15 mrem (0.23 ± 0.15 mSv) and 93 ± 59 mrem (0.93 ± 0.59 mSv), respectively. After the clean room had been implemented, average monthly absorbed radiation doses increased to 32 ± 16 mrem (0.32 ± 0.16 mSv) (P < 0.001) and 121 ± 89 mrem (1.21 ± 0.89 mSv) (P = 0.0015), respectively. When normalized for procedure volume, average monthly absorbed radiation doses after implementation of the clean room were still higher, at 29 ± 15 mrem (0.29 ± 0.15 mSv) (P = 0.001) and 110 ± 80 mrem (1.10 ± 0.80 mSv) (P = 0.039), respectively. CONCLUSION: After implementation of a radiopharmacy clean room, absorbed radiation doses to body and extremities increased by 26% and 18%, respectively, even after normalizing for procedure volume. Because absorbed radiation doses from other activities, such as patient dose administration and patient imaging, are assumed to remain relatively constant, these increases in absorbed radiation doses to staff are attributed to changes in work flow after implementation of the radiopharmacy clean room.


Subject(s)
Environment, Controlled , Occupational Exposure/analysis , Pharmacies , Radiation Dosage , Humans , Radiation Protection , Radiometry , Retrospective Studies