ABSTRACT
BACKGROUND: The use of low-titer group O whole blood is increasing. To reduce wastage, unused units can be converted to packed red blood cells. Supernatant is currently discarded post-conversion; however, it could be a valuable transfusable product. The aim of this study was to evaluate supernatant prepared from late-storage low-titer group O whole blood being converted to red blood cells, hypothesizing it will have higher hemostatic activity compared to fresh never-frozen liquid plasma. METHODS: Low-titer group O whole blood supernatant (n = 12) prepared on storage day 15 was tested on days 15, 21, and 26 and liquid plasma (n = 12) on 3, 15, 21, and 26. Same-day assays included cell counts, rotational thromboelastometry, and thrombin generation. Centrifuged plasma from units was banked for microparticle characterization, conventional coagulation, clot structure, hemoglobin, and additional thrombin generation assays. RESULTS: Low-titer group O whole blood supernatant contained more residual platelets and microparticles compared to liquid plasma. At day 15, low-titer group O whole blood supernatant elicited a faster intrinsic clotting time compared to liquid plasma (257 ± 41 vs. 299 ± 36 s, P = 0.044), and increased clot firmness (49 ± 9 vs. 28 ± 5 mm, P < 0.0001). Low-titer group O whole blood supernatant showed more significant thrombin generation compared to liquid plasma (day 15 endogenous thrombin potential 1,071 ± 315 vs. 285 ± 221 nM·min, P < 0.0001). Flow cytometry demonstrated low-titer group O whole blood supernatant contained significantly more phosphatidylserine and CD41+ microparticles. However, thrombin generation in isolated plasma suggested residual platelets in low-titer group O whole blood supernatant were a greater contributor than microparticles. Additionally, low-titer group O whole blood supernatant and liquid plasma showed no difference in clot structure, despite higher CD61+ microparticle presence. CONCLUSIONS: Plasma supernatant produced from late-storage low-titer group O whole blood shows comparable, if not enhanced, in vitro hemostatic efficacy to liquid plasma.
Subject(s)
Hemostatics , Thrombin , Thrombin/analysis , Hemostasis , Blood Coagulation , Blood Platelets , ThrombelastographyABSTRACT
BACKGROUND: Platelet (PLT) product transfusion is a life-saving therapy for actively bleeding patients. There is an urgent need to maintain PLT function and extend shelf life to improve outcomes in these patients. Cold-stored PLT (CS-PLT) maintain hemostatic potential better than room temperature-stored PLT (RT-PLT). However, whether function in long-term CS-PLT is maintained under physiological flow regimes and/or determined by cold-induced metabolic changes is unknown. OBJECTIVES: This study aimed to (i) compare the function of RT-PLT and CS-PLT under physiological flow conditions, (ii) determine whether CS-PLT maintain function after 3 weeks of storage, and (iii) identify metabolic pathways associated with the CS-PLT lesion. METHODS: We performed phenotypic and functional assessments of RT- and CS-PLT (22 °C and 4 °C storage, respectively; N = 10 unique donors) at storage days 0, 5, and/or 21 via metabolomics, flow cytometry, aggregation, thrombin generation, viscoelastic testing, and a microfluidic assay to measure primary hemostatic function. RESULTS: Day 21 4 °C PLT formed an occlusive thrombus under arterial shear at a similar rate to day 5 22 °C PLT. Day 21 4 °C PLTs had enhanced thrombin generation capacity compared with day 0 PLT and maintained functionality comparable to day RT-PLT across all assays performed. Key metrics from microfluidic assessment, flow cytometry, thrombin generation, and aggregation were associated with 4 °C storage, and metabolites involved in taurine and purine metabolism significantly correlated with these metrics. Taurine supplementation of PLT during storage improved hemostatic function under flow. CONCLUSION: CS-PLT stored for 3 weeks maintain hemostatic activity, and storage-induced phenotype and function are associated with taurine and purine metabolism.
Subject(s)
Hemostatics , Humans , Thrombin/metabolism , Blood Preservation , Blood Platelets/metabolism , Purines/metabolismABSTRACT
Trauma is the leading cause of death in individuals up to 45 years of age. Alterations in platelet function are a critical component of trauma-induced coagulopathy (TIC), yet these changes and the potential resulting dysfunction is incompletely understood. The lack of clinical assays available to explore platelet function in this patient population has hindered detailed understanding of the role of platelets in TIC. The objective of this study was to assess trauma patient ex vivo flow-dependent platelet hemostatic capacity in a microfluidic model. We hypothesized that trauma patients would have flow-regime dependent alterations in platelet function. Blood was collected from trauma patients with level I activations (N = 34) within 60 min of hospital arrival, as well as healthy volunteer controls (N = 10). Samples were perfused through a microfluidic model of injury at venous and arterial shear rates, and a subset of experiments were performed after incubation with fluorescent anti-CD41 to quantify platelets. Complete blood counts were performed as well as plasma-based assays to quantify coagulation times, fibrinogen, and von Willebrand factor (VWF). Exploratory correlation analyses were employed to identify relationships with microfluidic hemostatic parameters. Trauma patients had increased microfluidic bleeding times compared to healthy controls. While trauma patient samples were able to deposit a substantial amount of clot in the model injury site, the platelet contribution to microfluidic hemostasis was attenuated. Trauma patients had largely normal hematology and plasma-based coagulation times, yet had elevated D-Dimer and VWF. Venous microfluidic bleeding time negatively correlated with VWF, D-Dimer, and mean platelet volume (MPV), while arterial microfluidic bleeding time positively correlated with oxygenation. Arterial clot growth rate negatively correlated with red cell count, and positively with mean corpuscular volume (MCV). We observed changes in clot composition in trauma patient samples reflected by significantly diminished platelet contribution, which resulted in reduced hemostatic function in a microfluidic model of vessel injury. We observed a reduction in platelet clot contribution under both venous and arterial flow ex vivo in trauma patient samples. While our population was heterogenous and had relatively mild injury severity, microfluidic hemostatic parameters correlated with different patient-specific data depending on the flow setting, indicating potentially differential mechanistic pathways contributing to platelet hemostatic capacity in the context of TIC. These data were generated with the goal of identifying key features of platelet dysfunction in bleeding trauma patients under conditions of flow and to determine if these features correlate with clinically available metrics, thus providing preliminary surrogate markers of physiological platelet dysfunction to be further studied across larger cohorts. Future studies will continue to explore those relationships and further define mechanisms of TIC and their relationship with patient outcomes.