1.
Radiology ; 311(2): e231741, 2024 05.
Article in English | MEDLINE | ID: mdl-38771176

ABSTRACT

Performing CT in children comes with unique challenges such as greater degrees of patient motion, smaller and densely packed anatomy, and potential risks of radiation exposure. The technical advancements of photon-counting detector (PCD) CT enable decreased radiation dose and noise, as well as increased spatial and contrast resolution across all ages, compared with conventional energy-integrating detector CT. It is therefore valuable to review the relevant technical aspects and principles specific to protocol development on the new PCD CT platform to realize the potential benefits for this population. The purpose of this article, based on multi-institutional clinical and research experience from pediatric radiologists and medical physicists, is to provide protocol guidance for use of PCD CT in the imaging of pediatric patients.


Subject(s)
Photons , Radiation Dosage , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Child , Infant , Pediatrics/methods , Child, Preschool , Practice Guidelines as Topic
2.
Article in English | MEDLINE | ID: mdl-38626754

ABSTRACT

OBJECTIVE: Different methods can be used to condition imaging systems for clinical use. The purpose of this study was to assess how these methods complement one another in evaluating a system for clinical integration of an emerging technology, photon-counting computed tomography (PCCT), for thoracic imaging. METHODS: Four methods were used to assess a clinical PCCT system (NAEOTOM Alpha; Siemens Healthineers, Forchheim, Germany) across 3 reconstruction kernels (Br40f, Br48f, and Br56f). First, a phantom evaluation was performed using a computed tomography quality control phantom to characterize noise magnitude, spatial resolution, and detectability. Second, clinical images acquired using conventional and PCCT systems were used for a multi-institutional reader study where readers from 2 institutions were asked to rank their preference of images. Third, the clinical images were assessed in terms of in vivo image quality characterization of global noise index and detectability. Fourth, a virtual imaging trial was conducted using a validated simulation platform (DukeSim) that models PCCT and a virtual patient model (XCAT) with embedded lung lesions imaged under differing conditions of respiratory phase and positional displacement. Using known ground truth of the patient model, images were evaluated for quantitative biomarkers of lung intensity histograms and lesion morphology metrics. RESULTS: For the physical phantom study, the Br56f kernel was shown to have the highest resolution despite having the highest noise and lowest detectability. Readers across both institutions preferred the Br56f kernel (71% first rank) with a high interclass correlation (0.990). In vivo assessments found superior detectability for PCCT compared with conventional computed tomography but higher noise and reduced detectability with increased kernel sharpness. For the virtual imaging trial, Br40f was shown to have the best performance for histogram measures, whereas Br56f was shown to have the most precise and accurate morphology metrics. CONCLUSION: The 4 evaluation methods each have their strengths and limitations and bring complementary insight to the evaluation of PCCT. Although no method offers a complete answer, concordant findings between methods offer affirmatory confidence in a decision, whereas discordant ones offer insight for added perspective. Aggregating our findings, we concluded the Br56f kernel best for high-resolution tasks and Br40f for contrast-dependent tasks.

3.
Eur Radiol ; 33(12): 8745-8753, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37382617

ABSTRACT

OBJECTIVES: To determine whether image reconstruction with a higher matrix size improves image quality for lower extremity CTA studies. METHODS: Raw data from 50 consecutive lower extremity CTA studies acquired on two MDCT scanners (SOMATOM Flash, Force) in patients evaluated for peripheral arterial disease (PAD) were retrospectively collected and reconstructed with standard (512 × 512) and higher resolution (768 × 768, 1024 × 1024) matrix sizes. Five blinded readers reviewed representative transverse images in randomized order (150 total). Readers graded image quality (0 (worst)-100 (best)) for vascular wall definition, image noise, and confidence in stenosis grading. Ten patients' stenosis scores on CTA images were compared to invasive angiography. Scores were compared using mixed effects linear regression. RESULTS: Reconstructions with 1024 × 1024 matrix were ranked significantly better for wall definition (mean score 72, 95% CI = 61-84), noise (74, CI = 59-88), and confidence (70, CI = 59-80) compared to 512 × 512 (wall = 65, CI = 53 × 77; noise = 67, CI = 52 × 81; confidence = 62, CI = 52 × 73; p = 0.003, p = 0.01, and p = 0.004, respectively). Compared to 512 × 512, the 768 × 768 and 1024 × 1024 matrix improved image quality in the tibial arteries (wall = 51 vs 57 and 59, p < 0.05; noise = 65 vs 69 and 68, p = 0.06; confidence = 48 vs 57 and 55, p < 0.05) to a greater degree than the femoral-popliteal arteries (wall = 78 vs 78 and 85; noise = 81 vs 81 and 84; confidence = 76 vs 77 and 81, all p > 0.05), though for the 10 patients with angiography accuracy of stenosis grading was not significantly different. Inter-reader agreement was moderate (rho = 0.5). CONCLUSION: Higher matrix reconstructions of 768 × 768 and 1024 × 1024 improved image quality and may enable more confident assessment of PAD. CLINICAL RELEVANCE STATEMENT: Higher matrix reconstructions of the vessels in the lower extremities can improve perceived image quality and reader confidence in making diagnostic decisions based on CTA imaging. KEY POINTS: • Higher than standard matrix sizes improve perceived image quality of the arteries in the lower extremities. • Image noise is not perceived as increased even at a matrix size of 1024 × 1024 pixels. • Gains from higher matrix reconstructions are higher in smaller, more distal tibial and peroneal vessels than in femoropopliteal vessels.


Subject(s)
Arteries , Peripheral Arterial Disease , Humans , Constriction, Pathologic , Retrospective Studies , Lower Extremity/diagnostic imaging , Lower Extremity/blood supply , Computed Tomography Angiography/methods , Peripheral Arterial Disease/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods
4.
J Comput Assist Tomogr ; 46(1): 64-70, 2022.
Article in English | MEDLINE | ID: mdl-35099138

ABSTRACT

OBJECTIVE: The aim of the study was to compare effects of a 100-kilovoltage (kVp) tin filtration (Sn100kVp) with Advanced Modeled Iterative Reconstruction (ADMIRE) protocol to an automated kVp selection and filtered back projection (FBP) protocol on radiation dose and image quality of in noncontrast-enhanced pediatric chest computed tomography (CT). METHODS: This retrospective study included 55 children (12 ± 6 years) undergoing baseline imaging using automated kVp selection with FBP on a second-generation dual-source CT scanner and follow-up CT using Sn100kVp with ADMIRE on a third-generation dual-source CT scanner. The volume CT dose index, dose length product, size-specific dose estimate, and milliamperage were compared. Image quality was calculated using signal-to-noise ratio and subjectively evaluated by 2 radiologists. RESULTS: Mean volume CT dose index, dose length product, and size-specific dose estimate were lower for the Sn100kVp protocol with ADMIRE (0.83 ± 0.18 mGy, 21.9 ± 7.5 mGy × cm, 1.28 ± 0.24 mGy) compared with the automated kVp protocol with FBP (2.17 ± 1.10 mGy, 65.1 ± 41.1 mGy × cm, 3.25 ± 1.44 mGy, P < 0.001), whereas milliamperage was and subjective image quality were higher for Sn100kVp (P < 0.001). CONCLUSIONS: A Sn100kVp protocol with ADMIRE lowers dose while maintaining image quality in noncontrast-enhanced pediatric chest CT.


Subject(s)
Lung/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Thoracic/methods , Tomography, X-Ray Computed/methods , Adolescent , Algorithms , Child , Child, Preschool , Humans , Lung Transplantation , Radiation Dosage , Retrospective Studies , Tin
5.
Acta Radiol ; 63(6): 828-838, 2022 Jun.
Article in English | MEDLINE | ID: mdl-33878931

ABSTRACT

BACKGROUND: The value of dual-energy computed tomography (DECT)-based radiomics in renal lesions is unknown. PURPOSE: To develop DECT-based radiomic models and assess their incremental values in comparison to conventional measurements for differentiating enhancing from non-enhancing small renal lesions. MATERIAL AND METHODS: A total of 349 patients with 519 small renal lesions (390 non-enhancing, 129 enhancing) who underwent contrast-enhanced nephrographic phase DECT examinations between June 2013 and January 2020 on multiple DECT platforms were retrospectively recruited. Cohort A included all lesions, while cohort B included Bosniak II-IV and solid enhancing renal lesions. Radiomic models were built with features selected by the least absolute shrinkage and selection operator regression (LASSO). ROC analyses were performed to compare the diagnostic accuracy among conventional and radiomic models for predicting enhancing renal lesions. RESULTS: The individual iodine concentration (IC), normalized IC, mean attenuation on 75-keV images, radiomic model of iodine images, 75-keV images and a combined model integrating all the above-mentioned features all demonstrated high AUCs for predicting renal lesion enhancement in cohort A (AUCs = 0.934-0.979) as well as in the test dataset (AUCs = 0.892-0.962) of cohort B (P values with Bonferroni correction >0.003). The AUC (0.864) of mean attenuation on 75-keV images was significantly lower than those of other models (all P values ≤0.001) except the radiomic model of 75-keV images (P = 0.038) in the training dataset of cohort B. CONCLUSION: No incremental value was found by adding radiomic and machine learning analyses to iodine images for differentiating enhancing from non-enhancing renal lesions.


Subject(s)
Iodine , Tomography, X-Ray Computed , Humans , Kidney/diagnostic imaging , ROC Curve , Retrospective Studies , Tomography, X-Ray Computed/methods
6.
Pediatr Radiol ; 51(11): 2000-2008, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34244847

ABSTRACT

BACKGROUND: Widespread adoption of dual-energy computed tomography (DECT) requires evidence it does not cause higher radiation dose than conventional single-energy CT (SECT). While a few publications involving pediatric patients exist, most have focused on small cohorts. Hence, there is still a need for studies that ascertain what radiation doses are expected in larger populations that include representative ranges of patient sizes and ages. OBJECTIVE: To compare radiation dose and image quality of DECT and SECT abdominopelvic examinations in children as a function of patient size. MATERIALS AND METHODS: This retrospective study included 860 children (age range: 12.3±5.3 years) who underwent contrast-enhanced abdominopelvic exams on second-generation dual-source CT in a five-year period. Two groups, SECT and DECT, consisting of 430 children each, were matched by 5 effective diameters. Volume CT dose index (CTDIvol) and size-specific dose estimate (SSDE) were analyzed as a function of effective diameter. Objective image quality was compared between the groups. RESULTS: DECT SSDEs were lower across all effective patient diameters compared with SECT (mean: 8.5±1.8 mGv vs. 9.3±2.0 mGv, respectively, P≤0.001). DECT CTDIvol was lower compared to SECT (mean: 5.6±2.4 mGv vs. 6.1±2.7 mGv, respectively, P≤0.001) except in the smallest diameter group (<15 cm) where it was comparable to SECT (P=0.065). Objective image quality versus effective diameter between the two CT groups was comparable (P>0.05). CONCLUSION: In children, regardless of effective diameter, contrast-enhanced abdominopelvic DECT can be performed with a similar or lower dose and similar image quality compared with SECT examinations.


Subject(s)
Cone-Beam Computed Tomography , Tomography, X-Ray Computed , Adolescent , Child , Diagnostic Tests, Routine , Humans , Radiation Dosage , Retrospective Studies
7.
Radiology ; 291(2): 286-297, 2019 05.
Article in English | MEDLINE | ID: mdl-30912717

ABSTRACT

Dual-energy CT enables the simultaneous acquisition of CT images at two different x-ray energy spectra. By acquiring high- and low-energy spectral data, dual-energy CT can provide unique qualitative and quantitative information about tissue composition, allowing differentiation of multiple materials including iodinated contrast agents. The two dual-energy CT postprocessing techniques that best exploit the advantages of dual-energy CT in children are the material-decomposition images (which include virtual nonenhanced, iodine, perfused lung blood volume, lung vessel, automated bone removal, and renal stone characterization images) and virtual monoenergetic images. Clinical applications include assessment of the arterial system, lung perfusion, neoplasm, bowel diseases, renal calculi, tumor response to treatment, and metal implants. Of importance, the radiation exposure level of dual-energy CT is equivalent to or less than that of conventional single-energy CT. In this review, the authors discuss the basic principles of the dual-energy CT technologies and postprocessing techniques and review current clinical applications in the pediatric chest and abdomen.


Subject(s)
Algorithms , Radiography, Dual-Energy Scanned Projection , Tomography, X-Ray Computed , Adolescent , Child , Child, Preschool , Female , Humans , Infant , Male , Radiography, Abdominal , Radiography, Thoracic
8.
Radiology ; 293(3): 583-591, 2019 12.
Article in English | MEDLINE | ID: mdl-31573400

ABSTRACT

Background Results of recent phantom studies show that variation in CT acquisition parameters and reconstruction techniques may make radiomic features largely nonreproduceable and of limited use for prognostic clinical studies. Purpose To investigate the effect of CT radiation dose and reconstruction settings on the reproducibility of radiomic features, as well as to identify correction factors for mitigating these sources of variability. Materials and Methods This was a secondary analysis of a prospective study of metastatic liver lesions in patients who underwent staging with single-energy dual-source contrast material-enhanced staging CT between September 2011 and April 2012. Technique parameters were altered, resulting in 28 CT data sets per patient that included different dose levels, section thicknesses, kernels, and reconstruction algorithm settings. By using a training data set (n = 76), reproducible intensity, shape, and texture radiomic features (reproducibility threshold, R2 ≥ 0.95) were selected and correction factors were calculated by using a linear model to convert each radiomic feature to its estimated value in a reference technique. By using a test data set (n = 75), the reproducibility of hierarchical clustering based on 106 radiomic features measured with different CT techniques was assessed. Results Data in 78 patients (mean age, 60 years ± 10; 33 women) with 151 liver lesions were included. The percentage of radiomic features deemed reproducible for any variation of the different technical parameters was 11% (12 of 106). Of all technical parameters, reconstructed section thickness had the largest impact on the reproducibility of radiomic features (12.3% [13 of 106]) if only one technical parameter was changed while all other technical parameters were kept constant. The results of the hierarchical cluster analysis showed improved clustering reproducibility when reproducible radiomic features with dedicated correction factors were used (ρ = 0.39-0.71 vs ρ = 0.14-0.47). Conclusion Most radiomic features are highly affected by CT acquisition and reconstruction settings, to the point of being nonreproducible. Selecting reproducible radiomic features along with study-specific correction factors offers improved clustering reproducibility. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Sosna in this issue.


Subject(s)
Liver Neoplasms/diagnostic imaging , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Tomography, X-Ray Computed , Algorithms , Contrast Media , Female , Humans , Liver Neoplasms/pathology , Male , Middle Aged , Neoplasm Staging , Prospective Studies , Reproducibility of Results
9.
AJR Am J Roentgenol ; 212(2): 366-376, 2019 02.
Article in English | MEDLINE | ID: mdl-30667306

ABSTRACT

OBJECTIVE: The purpose of this study was to determine whether a single, uniform normalized iodine threshold reduces variability and enables reliable differentiation between vascular and nonvascular renal lesions independent of the dual-energy CT (DECT) platform used. MATERIALS AND METHODS: In this retrospective, HIPAA-compliant, institutional review board-approved study, 247 patients (156 men, 91 women; mean age ± SD, 67 ± 12 years old) with 263 renal lesions (193 nonvascular, 70 vascular) underwent unenhanced single-energy and contrast-enhanced DECT scans. One hundred and six nonvascular and 38 vascular lesions were scanned on two dual-source DECT (dsDECT) scanners, and 87 nonvascular and 32 vascular lesions were scanned on two rapid-kilovoltage-switching single-source DECT (rsDECT) scanners. Optimal absolute and normalized (to aorta) lesion iodine thresholds were determined for each platform type and for the entire cohort combined. RESULTS: Mean optimal absolute discriminant thresholds were 1.3 mg I/mL (95% CI, 1.2-1.9 mg I/mL), 1.6 mg I/mL (95% CI, 0.9-1.5 mg I/mL), and 1.5 mg I/mL (95% CI, 1.4-1.7 mg I/mL) for dsDECT, rsDECT, and combined cohorts, respectively. Optimal normalized discriminant thresholds were 0.3 mg I/mL (95% CI, 0.2-0.4 mg I/mL) for both the dsDECT and rsDECT cohorts, and 0.3 mg I/mL (0.3-0.4 mg I/mL) for the combined cohort. The AUC, sensitivity, and specificity for the combined optimal normalized discriminant threshold of 0.3 mg I/mL was 0.96 (95% CI, 0.92-1.00), 0.93 (0.84-0.97), and 0.95 (0.91-0.98), respectively. Normalization resulted in decreased variability and better lesion separation (effect size, 1.77 vs 1.69, p < 0.0001). CONCLUSION: The optimal absolute discriminant threshold for evaluating renal lesions varies depending on the type of DECT platform, though this difference is not statistically significant. Variation can be reduced with a better separation of vascular and nonvascular lesions by normalizing iodine quantification to the aorta.


Subject(s)
Kidney Neoplasms/blood supply , Kidney Neoplasms/diagnostic imaging , Radiography, Dual-Energy Scanned Projection , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Diagnosis, Differential , Female , Humans , Iodine/analysis , Kidney Neoplasms/chemistry , Male , Middle Aged , Retrospective Studies , Young Adult
10.
Radiology ; 287(3): 874-883, 2018 06.
Article in English | MEDLINE | ID: mdl-29470937

ABSTRACT

Purpose To investigate the relationship between energy level of virtual monoenergetic (VM) imaging and sensitivity in the detection of minimally enhancing renal lesions. Materials and Methods Phantoms simulating unenhanced and contrast material-enhanced renal parenchyma were equipped with inserts containing different concentrations of iodine (range, 0-1.15 mg iodine per milliliter). A total of 180 patients (117 men; mean age, 65.2 years ± 13.0 [standard deviation]) with 194 (62 solid, 132 cystic) renal lesions larger than 10 mm in diameter underwent unenhanced single-energy CT and contrast-enhanced dual-energy CT. VM imaging data sets were created for 70, 80, 90, and 100 keV. Renal lesions were measured, and enhancement was calculated. Area under the receiver operating characteristic curve (AUC) for renal lesion characterization was determined by using the DeLong method. Results The AUC was highest at 70 keV and decreased as energy increased toward 100 keV. AUC in the phantom decreased from 98% (95% confidence interval [CI]: 95, 100) at 70 keV to 88% (95% CI: 79, 96) at 100 keV (P = .004). AUC in patients decreased from 96% (95% CI: 94, 98) at 70 keV to 79% (95% CI: 71, 86) at 100 keV (P = .001). In patients with an enhancement threshold of 15 HU, sensitivity in the detection of solid renal lesions decreased between from 91% (49 of 62 [95% CI: 78, 97]) at 70 keV to 48% (33 of 62 [95% CI: 25, 71]) at 100 keV (P < .05), with no change in specificity (93% [120 of 132 {95% CI: 87, 97}] at 70 keV, 97% [125 of 132 {95% CI: 92, 99}] at 100 keV). Conclusion There is a reduction in diagnostic accuracy for renal lesion characterization with increasing VM imaging energy. The 70-keV setting may provide an optimal trade-off between sensitivity and specificity. © RSNA, 2018 Online supplemental material is available for this article.


Subject(s)
Contrast Media , Image Processing, Computer-Assisted/methods , Kidney Neoplasms/diagnostic imaging , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Aged , Female , Humans , Iodine , Kidney/diagnostic imaging , Male , Phantoms, Imaging , Radiography, Dual-Energy Scanned Projection , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity
11.
AJR Am J Roentgenol ; 211(3): 635-640, 2018 09.
Article in English | MEDLINE | ID: mdl-29949420

ABSTRACT

OBJECTIVE: The purpose of this study is to evaluate the potential of an automated kilo-voltage selection software for the reduction of lens dose in pediatric CT scans. MATERIALS AND METHODS: Two metal oxide semiconductor field effect transistor (MOSFET) detectors measured the lens dose in two anthropomorphic 1- and 5-year-old phantoms. These phantoms were scanned using a clinical pediatric brain protocol at 120 kVp as a control with the MDCT scanner. Scans were then repeated using automated kilovoltage software. The automated kilovoltage was set to operate at tube potentials of 120, 110, and 100 kVp. Dose savings were compared with the average lens dose of both eyes between automated kilovoltage and the control setting. Image quality was studied by contrast-to-noise ratios (CNRs) for each setting. RESULTS: The mean (± SD) lens dose from the routine brain scan without automated kilovoltage was 0.92 ± 0.03 cGy and 0.81 ± 0.03 cGy for the 1- and 5-year-old phantoms, respectively. Use of the automated kilovoltage software at 120 kVp, 110 kVp, and 100 kVp resulted in dose reductions of 9.8%, 17.4%, and 19.6%, respectively, for the 1-year-old phantom and 1.2%, 8.6%, and 17.3%, respectively, for the 5-year-old phantom. The CNR for all automated kilovoltage scans was within 11% of the control scans for the 1-year-old and within 6% for the 5-year-old phantom. CONCLUSION: Our results show that automated kilovoltage software is effective for reducing the radiation dose to the lens of the eye in pediatric patients. Furthermore, the image quality by CNR remained acceptable within 11% of the baseline for all kilovoltage settings used.


Subject(s)
Brain/diagnostic imaging , Radiation Dosage , Software , Tomography, X-Ray Computed , Child, Preschool , Humans , Image Processing, Computer-Assisted , Infant , Phantoms, Imaging
12.
AJR Am J Roentgenol ; 210(5): W205-W217, 2018 May.
Article in English | MEDLINE | ID: mdl-29547057

ABSTRACT

OBJECTIVE: The purpose of this study was to determine in vitro and in vivo the optimal threshold for renal lesion vascularity at low-energy (40-60 keV) virtual monoenergetic imaging. MATERIALS AND METHODS: A rod simulating unenhanced renal parenchymal attenuation (35 HU) was fitted with a syringe containing water. Three iodinated solutions (0.38, 0.57, and 0.76 mg I/mL) were inserted into another rod that simulated enhanced renal parenchyma (180 HU). Rods were inserted into cylindric phantoms of three different body sizes and scanned with single- and dual-energy MDCT. In addition, 102 patients (32 men, 70 women; mean age, 66.8 ± 12.9 [SD] years) with 112 renal lesions (67 nonvascular, 45 vascular) measuring 1.1-8.9 cm underwent single-energy unenhanced and contrast-enhanced dual-energy CT. Optimal threshold attenuation values that differentiated vascular from nonvascular lesions at 40-60 keV were determined. RESULTS: Mean optimal threshold values were 30.2 ± 3.6 (standard error), 20.9 ± 1.3, and 16.1 ± 1.0 HU in the phantom, and 35.9 ± 3.6, 25.4 ± 1.8, and 17.8 ± 1.8 HU in the patients at 40, 50, and 60 keV. Sensitivity and specificity for the thresholds did not change significantly between low-energy and 70-keV virtual monoenergetic imaging (sensitivity, 87-98%; specificity, 90-91%). The AUC from 40 to 70 keV was 0.96 (95% CI, 0.93-0.99) to 0.98 (95% CI, 0.95-1.00). CONCLUSION: Low-energy virtual monoenergetic imaging at energy-specific optimized attenuation thresholds can be used for reliable characterization of renal lesions.


Subject(s)
Kidney Neoplasms/blood supply , Kidney Neoplasms/diagnostic imaging , Multidetector Computed Tomography/methods , Aged , Contrast Media , Female , Humans , Iodine , Kidney/diagnostic imaging , Male , Phantoms, Imaging , Radiographic Image Interpretation, Computer-Assisted , Sensitivity and Specificity , Signal-To-Noise Ratio
13.
AJR Am J Roentgenol ; 211(3): 571-579, 2018 09.
Article in English | MEDLINE | ID: mdl-30040464

ABSTRACT

OBJECTIVE: The objective of this study is to determine whether single-phase contrast-enhanced dual-energy CT (DECT) material attenuation analysis improves the characterization of small (< 2.0 cm) incidental indeterminate hypoattenuating hepatic lesions, compared with conventional single-energy CT evaluation. MATERIALS AND METHODS: This retrospective study involved 55 patients (24 men and 31 women; mean [± SD] age, 63.9 ± 15.3 years) with 77 incidental hypoattenuating hepatic lesions (59 benign and 18 malignant lesions) measuring 0.5-2.0 cm who underwent single-phase contrast-enhanced DECT of the abdomen for pain. For each lesion, attenuation measurements were obtained using blended 120-kVp-equivalent images and contrast map images. DECT material attenuation images were used for iodine quantification. Optimal lesion attenuation and iodine concentration threshold values that best distinguished benign lesions from malignant lesions were generated using smooth bootstrapping. The diagnostic accuracy of the optimized thresholds was compared using the Wilcox rank sum test. RESULTS: The optimal mean (± standard error) attenuation threshold values that best differentiated benign and malignant lesions were 50.2 ± 5.2 HU and 11.5 ± 2.0 HU when blended 120-kVp and contrast map images, respectively, were used. The iodine concentration (expressed as milligrams of iodine per milliliter) differed significantly (p < 0.0001) between benign lesions (0.6 ± 0.4 mg I/mL) and malignant lesions (1.7 ± 0.4 mg I/mL). The optimal iodine concentration that best distinguished between benign and malignant lesions was 1.2 ± 0.1 mg I/mL. The sensitivity, specificity, and AUC value were highest for iodine concentration (0.94, 0.93, and 0.97, respectively), compared with blended images (0.89, 0.70, and 0.81, respectively) and contrast map images (0.94, 0.64, 0.77, respectively). CONCLUSION: Iodine quantification performed using single-phase contrast-enhanced DECT material attenuation images improves the characterization of small (< 2 cm) incidental indeterminate hypoattenuating hepatic lesions, compared with conventional attenuation measurements.


Subject(s)
Contrast Media , Iopamidol , Liver Neoplasms/diagnostic imaging , Tomography, X-Ray Computed , Adult , Aged , Aged, 80 and over , Female , Humans , Incidental Findings , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies , Sensitivity and Specificity
14.
Radiology ; 283(2): 526-537, 2017 05.
Article in English | MEDLINE | ID: mdl-27935766

ABSTRACT

Purpose To develop, in a phantom environment, a method to obtain multidetector computed tomographic (CT) data sets at multiple radiation exposure levels within the same patient and to validate its use for potential dose reduction by using different image reconstruction algorithms for the detection of liver metastases. Materials and Methods The American College of Radiology CT accreditation phantom was scanned by using a dual-source multidetector CT platform. By adjusting the radiation output of each tube, data sets at six radiation exposure levels (100%, 75%, 50%, 37.5%, 25%, and 12.5%) were reconstructed from two consecutive dual-source single-energy (DSSE) acquisitions, as well as a conventional single-source acquisition. A prospective, HIPAA-compliant, institutional review board-approved study was performed by using the same DSSE strategy in 19 patients who underwent multidetector CT of the liver for metastatic colorectal cancer. All images were reconstructed by using conventional weighted filtered back projection (FBP) and sinogram-affirmed iterative reconstruction with strength level of 3 (SAFIRE-3). Objective image quality metrics were compared in the phantom experiment by using multiple linear regression analysis. Generalized linear mixed-effects models were used to analyze image quality metrics and diagnostic performance for lesion detection by readers. Results The phantom experiment showed comparable image quality between DSSE and conventional single-source acquisition. In the patient study, the mean size-specific dose estimates for the six radiation exposure levels were 13.0, 9.8, 5.8, 4.4, 3.2, and 1.4 mGy. For each radiation exposure level, readers' perception of image quality and lesion conspicuity was consistently ranked superior with SAFIRE-3 when compared with FBP (P ≤ .05 for all comparisons). Reduction of up to 62.5% in radiation exposure by using SAFIRE-3 yielded similar reader rankings of image quality and lesion conspicuity when compared with routine-dose FBP. Conclusion A method was developed and validated to synthesize multidetector CT data sets at multiple radiation exposure levels within the same patient. This technique may provide a foundation for future clinical trials aimed at estimating potential radiation dose reduction by using iterative reconstructions. © RSNA, 2016 Online supplemental material is available for this article.


Subject(s)
Liver Neoplasms/diagnostic imaging , Liver Neoplasms/secondary , Multidetector Computed Tomography/instrumentation , Phantoms, Imaging , Radiation Exposure/analysis , Radiometry/instrumentation , Adult , Aged , Female , Humans , Male , Middle Aged , Multidetector Computed Tomography/methods , Patient-Centered Care/methods , Radiation Dosage , Radiation Exposure/prevention & control , Radiation Protection/methods , Radiography, Dual-Energy Scanned Projection/instrumentation , Radiography, Dual-Energy Scanned Projection/methods , Radiometry/methods , Reproducibility of Results , Sensitivity and Specificity
15.
J Comput Assist Tomogr ; 41(1): 39-47, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27560021

ABSTRACT

PURPOSE: To investigate the impact of a second-generation noise-optimized monoenergetic algorithm on selection of the optimal energy level, image quality, and effect of patient body habitus for dual-energy multidetector computed tomography of the pancreas. MATERIALS AND METHODS: Fifty-nine patients (38 men, 21 women) underwent dual-energy multidetector computed tomography (80/Sn140 kV) in the pancreatic parenchymal phase. Image data sets, at energy levels ranging from 40 to 80 keV (in 5-keV increments), were reconstructed using first-generation and second-generation noise-optimized monoenergetic algorithm. Noise, pancreatic contrast-to-noise ratio (CNRpancreas), and CNR with a noise constraint (CNRNC) were calculated and compared among the different reconstructed data sets. Qualitative assessment of image quality was performed by 3 readers. RESULTS: For all energy levels below 70 keV, noise was significantly lower (P ≤ 0.05) and CNRpancreas significantly higher (P < 0.001), with the second-generation monoenergetic algorithm. Furthermore, the second-generation algorithm was less susceptible to variability related to patient body habitus in the selection of the optimal energy level. The maximal CNRpancreas occurred at 40 keV in 98% (58 of 59) of patients with the second-generation monoenergetic algorithm. However, the CNRNC and readers' image quality scores showed that, even with a second-generation monoenergetic algorithm, higher reconstructed energy levels (60-65 keV) represented the optimal energy level. CONCLUSIONS: Second-generation noise-optimized monoenergetic algorithm can improve the image quality of lower-energy monoenergetic images of the pancreas, while decreasing the variability related to patient body habitus in selection of the optimal energy level.


Subject(s)
Algorithms , Body Size , Pancreatic Neoplasms/diagnostic imaging , Radiation Exposure/prevention & control , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Humans , Middle Aged , Pancreatic Neoplasms/physiopathology , Radiation Dosage , Radiation Exposure/analysis , Radiation Protection/methods , Radiographic Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity , Signal-To-Noise Ratio
16.
AJR Am J Roentgenol ; 206(6): 1222-32, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27058192

ABSTRACT

OBJECTIVE: The purpose of this study is to investigate whether the reduction in noise using a second-generation monoenergetic algorithm can improve the conspicuity of hypervascular liver tumors on dual-energy CT (DECT) images of the liver. MATERIALS AND METHODS: An anthropomorphic liver phantom in three body sizes and iodine-containing inserts simulating hypervascular lesions was imaged with DECT and single-energy CT at various energy levels (80-140 kV). In addition, a retrospective clinical study was performed in 31 patients with 66 hypervascular liver tumors who underwent DECT during the late hepatic arterial phase. Datasets at energy levels ranging from 40 to 80 keV were reconstructed using first- and second-generation monoenergetic algorithms. Noise, tumor-to-liver contrast-to-noise ratio (CNR), and CNR with a noise constraint (CNRNC) set with a maximum noise increase of 50% were calculated and compared among the different reconstructed datasets. RESULTS: The maximum CNR for the second-generation monoenergetic algorithm, which was attained at 40 keV in both phantom and clinical datasets, was statistically significantly higher than the maximum CNR for the first-generation monoenergetic algorithm (p < 0.001) or single-energy CT acquisitions across a wide range of kilovoltage values. With the second-generation monoenergetic algorithm, the optimal CNRNC occurred at 55 keV, corresponding to lower energy levels compared with first-generation algorithm (predominantly at 70 keV). Patient body size did not substantially affect the selection of the optimal energy level to attain maximal CNR and CNRNC using the second-generation monoenergetic algorithm. CONCLUSION: A noise-optimized second-generation monoenergetic algorithm significantly improves the conspicuity of hypervascular liver tumors.


Subject(s)
Algorithms , Carcinoma/diagnostic imaging , Image Processing, Computer-Assisted , Liver Neoplasms/diagnostic imaging , Radiography, Dual-Energy Scanned Projection , Tomography, X-Ray Computed , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Phantoms, Imaging , Retrospective Studies , Signal-To-Noise Ratio , Young Adult
17.
Radiology ; 275(3): 735-45, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25751228

ABSTRACT

PURPOSE: To assess the effect of radiation dose reduction on low-contrast detectability by using an advanced modeled iterative reconstruction (ADMIRE; Siemens Healthcare, Forchheim, Germany) algorithm in a contrast-detail phantom with a third-generation dual-source multidetector computed tomography (CT) scanner. MATERIALS AND METHODS: A proprietary phantom with a range of low-contrast cylindrical objects, representing five contrast levels (range, 5-20 HU) and three sizes (range, 2-6 mm) was fabricated with a three-dimensional printer and imaged with a third-generation dual-source CT scanner at various radiation dose index levels (range, 0.74-5.8 mGy). Image data sets were reconstructed by using different section thicknesses (range, 0.6-5.0 mm) and reconstruction algorithms (filtered back projection [FBP] and ADMIRE with a strength range of three to five). Eleven independent readers blinded to technique and reconstruction method assessed all data sets in two reading sessions by measuring detection accuracy with a two-alternative forced choice approach (first session) and by scoring the total number of visible object groups (second session). Dose reduction potentials based on both reading sessions were estimated. Results between FBP and ADMIRE were compared by using both paired t tests and analysis of variance tests at the 95% significance level. RESULTS: During the first session, detection accuracy increased with increasing contrast, size, and dose index (diagnostic accuracy range, 50%-87%; interobserver variability, ±7%). When compared with FBP, ADMIRE improved detection accuracy by 5.2% on average across the investigated variables (P < .001). During the second session, a significantly increased number of visible objects was noted with increasing radiation dose index, section thickness, and ADMIRE strength over FBP (up to 80% more visible objects, P < .001). Radiation dose reduction potential ranged from 56% to 60% and from 4% to 80% during the two sessions, respectively. CONCLUSION: Low-contrast detectability performance increased with increasing object size, object contrast, dose index, section thickness, and ADMIRE strength. Compared with FBP, ADMIRE allows a substantial radiation dose reduction while preserving low-contrast detectability. Online supplemental material is available for this article.


Subject(s)
Algorithms , Contrast Media , Image Processing, Computer-Assisted , Multidetector Computed Tomography/instrumentation , Radiation Dosage , Equipment Design , Models, Theoretical , Phantoms, Imaging
18.
AJR Am J Roentgenol ; 205(4): 834-9, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26397333

ABSTRACT

OBJECTIVE: The purpose of this study was to investigate, both in a phantom experiment and a within-patient clinical study the relationships among radiation dose, image noise, pitch, and body size in MDCT angiography of the thoracoabdominal aorta, with the use of high-pitch dual-source and standard-pitch single-source acquisitions. MATERIALS AND METHODS: A proprietary tapered phantom consisting of four ultrahigh-molecular-weight polyethylene cylinders was used to mimic the body size ranges (small, medium, large, and extra large) of patients in the United States. The phantom was imaged using both standard-pitch (0.8) and various high-pitch (range, 2.0-3.2 [in increments of 0.4]) settings. Standard-pitch and high-pitch acquisitions were also performed in 45 patients (27 men, 18 women; mean age, 67.6 years). RESULTS: At standard pitch, the volume CT dose index (CTDIvol) increased with phantom size, in a logistic sigmoid relationship. At high-pitch settings, the CTDIvol increased gradually in relation to phantom size, up to a threshold (denoted by tCTDI[pitch] ≈ 48.3-7.5 pitch), which linearly decreased (R(2) = 0.99) with pitch (maximum CTDIvol output at pitch [maxCTDI(pitch)] ≈ 18.9-3.9 pitch). A linear decrease in the size-specific dose estimate (SSDE) was observed beyond phantom size thresholds (tSSDE[pitch] ≈ 47.6-8.6 pitch) linearly decreasing (R(2) = 0.98) with pitch (maximum SSDE output at pitch [maxSSDE(pitch)] ≈ 15.5-1.3 pitch). Image noise was statistically significantly lower at standard pitch than at high-pitch settings (p = 0.01). In patients, statistically significant differences were noted between standard and high-pitch settings in the mean CTDIvol(10.8 ± 2.6 and 8.3 ± 0.7 mGy, respectively), SSDE (11.3 ± 2.1 and 8.8 ± 1.5 mGy, respectively), and noise (9.7 ± 2.2 and 14 ± 4.2, respectively) (p < .0001, for all comparisons). CONCLUSION: Lower radiation dose levels achieved with the use of a high-pitch technique reflect limitations in tube output occurring for medium to large body sizes, with an associated exponential increase in noise. The standard- and high-pitch techniques yield similar radiation dose levels for small body sizes.


Subject(s)
Aorta/radiation effects , Aortography/methods , Multidetector Computed Tomography/methods , Radiation Dosage , Aged , Body Size , Female , Humans , Male , Phantoms, Imaging , Retrospective Studies
19.
Neuroradiology ; 57(6): 639-44, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25779098

ABSTRACT

INTRODUCTION: Cerebrospinal fluid shunts are primarily used for the treatment of hydrocephalus. Shunt complications may necessitate multiple non-contrast head CT scans resulting in potentially high levels of radiation dose starting at an early age. A new head CT protocol using automatic exposure control and automated tube potential selection has been implemented at our institution to reduce radiation exposure. The purpose of this study was to evaluate the reduction in radiation dose achieved by this protocol compared with a protocol with fixed parameters. METHODS: A retrospective sample of 60 non-contrast head CT scans assessing for cerebrospinal fluid shunt malfunction was identified, 30 of which were performed with each protocol. The radiation doses of the two protocols were compared using the volume CT dose index and dose length product. The diagnostic acceptability and quality of each scan were evaluated by three independent readers. RESULTS: The new protocol lowered the average volume CT dose index from 15.2 to 9.2 mGy representing a 39 % reduction (P < 0.01; 95 % CI 35-44 %) and lowered the dose length product from 259.5 to 151.2 mGy/cm representing a 42 % reduction (P < 0.01; 95 % CI 34-50 %). The new protocol produced diagnostically acceptable scans with comparable image quality to the fixed parameter protocol. CONCLUSION: A pediatric shunt non-contrast head CT protocol using automatic exposure control and automated tube potential selection reduced patient radiation dose compared with a fixed parameter protocol while producing diagnostic images of comparable quality.


Subject(s)
Cerebrospinal Fluid Shunts , Hydrocephalus/diagnostic imaging , Hydrocephalus/therapy , Radiation Dosage , Radiation Exposure/prevention & control , Tomography, X-Ray Computed/methods , Adolescent , Adult , Child , Child, Preschool , Clinical Protocols , Equipment Failure , Female , Humans , Infant , Male , Retrospective Studies , Young Adult
20.
Radiology ; 273(3): 813-20, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25162309

ABSTRACT

PURPOSE: To investigate whether dual-energy multidetector row computed tomographic (CT) imaging with iodine quantification is able to distinguish between clear cell and papillary renal cell carcinoma ( RCC renal cell carcinoma ) subtypes. MATERIALS AND METHODS: In this retrospective, HIPAA-compliant, institutional review board-approved study, 88 patients (57 men, 31 women) with diagnosis of either clear cell or papillary RCC renal cell carcinoma at pathologic analysis, who underwent contrast material-enhanced dual-energy nephrographic phase study between December 2007 and June 2013, were included. Five readers, blinded to pathologic diagnosis, independently evaluated all cases by determining the lesion iodine concentration on color-coded iodine maps. The receiving operating characteristic curve analysis was adopted to estimate the optimal threshold for discriminating between clear cell and papillary RCC renal cell carcinoma , and results were validated by using a leave-one-out cross-validation. Interobserver agreement was assessed by using an intraclass correlation coefficient. The correlation between tumor iodine concentration and tumor grade was investigated. RESULTS: A tumor iodine concentration of 0.9 mg/mL represented the optimal threshold to discriminate between clear cell and papillary RCC renal cell carcinoma , and it yielded the following: sensitivity, 98.2% (987 of 1005 [95% confidence interval: 97.7%, 98.7%]); specificity, 86.3% (272 of 315 [95% confidence interval: 85.0%, 87.7%]); positive predictive value, 95.8% (987 of 1030 [95% confidence interval: 95.0%, 96.6%]); negative predictive value, 93.7% (272 of 290 [95% confidence interval: 92.8%, 94.7%]); overall accuracy of 95.3% (1259 of 1320 [95% confidence interval: 94.6%, 96.2%]), with an area under the curve of 0.923 (95% confidence interval: 0.913, 0.933). An excellent agreement was found among the five readers in measured tumor iodine concentration (intraclass correlation coefficient, 0.9990 [95% confidence interval: 0. 9987, 0.9993). A significant correlation was found between tumor iodine concentration and tumor grade for both clear cell (τ = 0.85; P < .001) and papillary RCC renal cell carcinoma (τ = 0.53; P < .001). CONCLUSION: Dual-energy multidetector CT with iodine quantification can be used to distinguish between clear cell and papillary RCC renal cell carcinoma , and it provides insights regarding the tumor grade.


Subject(s)
Carcinoma, Papillary/diagnostic imaging , Carcinoma, Renal Cell/diagnostic imaging , Kidney Neoplasms/diagnostic imaging , Multidetector Computed Tomography , Adult , Aged , Aged, 80 and over , Carcinoma, Papillary/pathology , Carcinoma, Papillary/surgery , Carcinoma, Renal Cell/pathology , Carcinoma, Renal Cell/surgery , Contrast Media , Diagnosis, Differential , Female , Humans , Iopamidol/analogs & derivatives , Kidney Neoplasms/pathology , Kidney Neoplasms/surgery , Male , Middle Aged , Nephrectomy , Retrospective Studies